gURESRY <br />O <br />m <br />DEMOLITION LEGEND <br />SYMBOL <br />DESCRIPTION <br />EXISTING TO REMAIN <br />EXISTING TO BE REMOVED <br />DEMO TO THIS POINT <br />D <br />0 0 <br />)R ` / i ` / I \ ELEV. <br />LOBBY <br />1 , ! <br />' COMPUTER <br />' ROOM I CATH LAB #3---- <br />012 IE <br />LI I i T. 1 <br />' OFFICE <br />' 004 <br />I <br />it I I I <br />OFFICE <br />I i L� \ \ TV <br />���-----�L------_-��---_-b <br />■ I <br />i I I IQ CONTROL <br />PS <br />I I I ROOM /. <br />006 i ( M 008 <br />P I - I' I I I' W <br />U. <br />CORRIDOR <br />SECOND FLOOR SYSTEMS PLAN - DEMOLITION <br />fill 11 1 1 <br />0' 2' 4' 8' 16' 24' <br />O KEY NOTES: <br />1. CONTRACTOR SHALL RELOCATE EXISTING FIRE ALARM DEVICE. REFER TO NEW CONSTRUCTION <br />PLAN FOR NEW LOCATION. <br />2. CONTRACTOR SHALL RELOCATE EXISTING AUTOMATIC DOOR OPENER. REFER TO NEW CONSTRUCTION <br />PLAN FOR NEW LOCATION. <br />3. CONTRACTOR SHALL RELOCATE EXISTING PAGING SYSTEM SPEAKER. REFER TO NEW CONSTRUCTION <br />PLAN FOR NEW LOCATION. <br />LIMIT OF DEMOLITION <br />DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL FIXTURES, DEVICES, PANELBOARDS AND <br />CONNECTIONS TO EXISTING ELECTRICAL EQUIPMENT IN THIS AREA UNLESS OTHERWISE NOTED <br />HERE OR ON OTHER DRAWINGS. REFER TO ELECTRICAL SPECIFICATION SECTION 16010 FOR OTHER <br />REQUIREMENTS. ALL EXISTING RACEWAYS PASSING THROUGH THIS AREA FEEDING OTHER AREAS <br />SHALL REMAIN INTACT AND OPERATIONAL. ALL OTHER RACEWAYS SHALL BE REMOVED. <br />TEMPORARILY REMOVE EXIT SIGNAGE AND RE -DIRECT OTHER EXIT SIGNS PER THE ARCHITECTURAL <br />LIFE SAFETY PLAN FOR APPROPRIATE EGRESS DURING CONSTRUCTION PERIOD. REPLACE EXIT <br />SIGNS PER THE FINAL ARCHITECTURAL LIFE SAFETY PLAN PRIOR TO FINAL INSPECTION. <br />IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO REMOVE AND REINSTALL ANY <br />LIGHT FIXTURES OR CEILING MOUNTED DEVICES THAT NEED TO BE TEMPORARILY REMOVED DUE <br />TO THE RENOVATION OF ANY MECHANICAL OR ELECTRICAL SYSTEMS. THE CONTRACTOR SHALL <br />VERIFY ALL AREAS OF POTENTIAL RE -WORK PRIOR TO BID. <br />CONTRACTOR SHALL MAINTAIN EXISTING FIRE ALARM SYSTEM WITHIN AREA OF DEMOLITION <br />THROUGHOUT CONSTRUCTION PERIOD. PROVIDE SMOKE DETECTOR COVERS DURING WORK <br />HOURS AND REMOVE SMOKE DETECTOR COVERS OUTSIDE OF WORK HOURS. <br />THE ELECTRICAL CONTRACTOR SHALL PROVIDE POWER TO THE NEGATIVE AIR MACHINE UTILIZED <br />DURING THE DEMOLITION AND NEW CONSTRUCTION PHASES FROM THE EQUIPMENT SYSTEM OF <br />THE ESSENTIAL SYSTEM. <br />O <br />NEW CONSTRUCTION LEGEND <br />SYMBOL <br />DESCRIPTION <br />EXISTING TO REMAIN <br />NEW CONSTRUCTION <br />CONNECT TO EXIST. AT THIS POINT <br />II ff <br />O 1= <br />IURESRY <br />SECOND FLOOR SYSTEMS PLAN - NEW CONSTRUCTION <br />1'1'I 1 I 1 1 <br />0' 2' 4' 8' 16' 24' <br />O KEY NOTES: <br />1. NEW LOCATIONS OF EXISTING FIRE ALARM DEVICES. SMOKE DETECTORS SHALL BE LOCATED WITHIN 5' ON BOTH SIDES <br />OF DOUBLE DOORS. RECONNECT ALL DEVICES AND CERTIFY AS REQUIRED. <br />2. NEW LOCATION OF EXISTING AUTOMATIC DOOR OPENER. CONNECT NEW ACCESS CONTROL HARDWARE AS INDICATED. <br />3. NEW LOCATION OF EXISTING PAGING SYSTEM SPEAKER. MAINTAIN EXISTING CONNECTION TO HOSPITAL PAGING SYSTEM. <br />4. NEW PAGING SYSTEM SPEAKER TO BE CONNECTED TO HOSPITAL PAGING SYSTEM. <br />5. NEW NURSECALL SYSTEM DEVICES SHALL BE CONNECTED TO DUKANE PROCARE 6000 SYSTEM LOCATED IN CVICU. <br />6. CONTRACTOR SHALL VERIFY DESIRED NUMBER OF DATA/VOICE CONNECTIONS WITH OWNER. TYPICAL. <br />ML <br />iO E-�w�•k,Cy <br />SUBMITTED PLAN(S) HAVE BEEN RI <br />BY ZEPHYRHELLS FIRE MARSHAL'S <br />Reviewer. <br />BU LDING SHALL `'OM -PLY VVT7h <br />ALL APPLICABLE BUILD -IN& <br />ELECTRICA% T'i.UMB G AND <br />MECH.t W 110 t 0lMs <br />m <br />H <br />U <br />Project No. 08009.00 <br />E4. 1 <br />02008 BH/PA Architects, Inc. <br />