1000 GENERAL NOTES: <br />1. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH PROJECT SPECIFICATIONS <br />AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. <br />CONSULT THESE DRAWINGS FOR OPENINGS, DEPRESSIONS, EQUIPMENT WEIGHTS AND <br />LOCATIONS, EMBEDDED ITEMS AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. <br />2. DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. ANY DISCREPANCIES <br />SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD BEFORE PROCEEDING <br />WITH THE AFFECTED PART OF THE WORK. <br />3. NO STRUCTURAL MEMBER OR COMPONENT SHALL BE CUT, NOTCHED, OR OTHERWISE ALTERED <br />UNLESS APPROVED IN WRITING BY THE ENGINEER OF RECORD. THE CONTRACTOR SHALL <br />BE RESPONSIBLE FOR ANY AND ALL COSTS INCURRED BY THE ENGINEER OF RECORD FOR <br />REVIEW OF ANY SUCH DEVIATIONS. <br />4. DO NOT SCALE DRAWINGS. <br />5. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING <br />IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION <br />PROCEDURES AND SEQUENCE TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS <br />DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, <br />TEMPORARY BRACING, GUYS OR TIE -DOWNS. <br />6. DETAILS LABELED "TYPICAL DETAILS" ON THE DRAWINGS SHALL APPLY TO ALL <br />SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE <br />SPECIFICALLY DETAILED. THE APPLICABILITY OF THE DETAIL TO ITS LOCATION ON <br />THE DRAWINGS CAN BE DETERMINED BY THE TITLE OF DETAIL. SUCH DETAILS SHALL <br />APPLY WHETHER OR NOT THEY ARE REFERENCED AT EACH LOCATION. QUESTIONS <br />REGARDING APPLICABILITY OF TYPICAL DETAILS SHALL BE DETERMINED BY THE <br />ENGINEER OF RECORD. <br />7. THE GENERAL CONTRACTOR SHALL COMPARE THE ARCHITECTURAL, MECHANICAL, <br />ELECTRICAL, PLUMBING, CIVIL AND STRUCTURAL DRAWINGS AND REPORT ANY <br />DISCREPANCIES BETWEEN EACH SET OF DRAWINGS AND WITHIN EACH SET OF DRAWINGS TO <br />THE ARCHITECT AND ENGINEER OF RECORD PRIOR TO THE FABRICATION AND <br />INSTALLATION OF ANY STRUCTURAL MEMBERS. <br />8. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED <br />STRUCTURE, AND DO NOT INDICATE THE METHOD OR MEANS OF CONSTRUCTION. THE <br />CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY <br />RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, PROCEDURES, TECHNIQUES, <br />SEQUENCE AND SAFETY. THE ENGINEER DOES NOT HAVE CONTROL OR CHARGE OF, AND <br />SHALL NOT BE RESPONSIBLE FOR, CONSTRUCTION MEANS, METHODS, TECHNIQUES, <br />SEQUENCES, OR PROCEDURES, FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION <br />WITH THE WORK, FOR THE ACTS OR OMISSION OF THE CONTRACTOR, SUBCONTRACTOR OR <br />ANY OTHER PERSONS PERFORMING ANY OF THE WORK, OR FOR THE FAILURE OF ANY OF <br />THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. <br />9. THE STRUCTURAL ENGINEER'S OBLIGATIONS TO REVIEW SHOP DRAWINGS AND OTHER <br />SUBMITTALS AND TO RETURN THEM IN A TIMELY MANNER ARE CONDITIONED UPON THE <br />PRIOR REVIEW AND APPROVAL OF THE SHOP DRAWINGS OR SUBMITTALS BY THE <br />CONTRACTOR AS REQUIRED IN THE CONSTRUCTION CONTRACT AND THE CONTRACTOR'S <br />SUBMITTAL OF THE SHOP DRAWINGS AND OTHER SUBMITTALS IN ACCORDANCE WITH A <br />WRITTEN SCHEDULE DISTRIBUTED IN ADVANCE TO THE ENGINEER IDENTIFYING THE DATES <br />FOR THE SUBMITTAL OF THE VARIOUS SHOP DRAWINGS AND SUBMITTALS. <br />10. PERIODIC SITE OBSERVATION BY FIELD REPRESENTATIVES OF TLC ENGINEERING FOR <br />ARCHITECTURE IS SOLELY FOR THE PURPOSE OF DETERMINING IF THE WORK OF THE <br />CONTRACTOR IS PROCEEDING IN GENERAL ACCORDANCE WITH THE STRUCTURAL CONTRACT <br />DOCUMENTS. THIS LIMITED SITE OBSERVATION SHALL NOT BE CONSTRUED AS <br />EXHAUSTIVE OR CONTINUOUS TO CHECK THE QUALITY OR QUANTITY OF THE WORK. <br />11. ALL STRUCTURES REQUIRE PERIODIC MAINTENANCE TO EXCEED LIFESPAN AND TO ENSURE <br />STRUCTURAL INTEGRITY FROM EXPOSURE TO THE ENVIRONMENT. A PLANNED PROGRAM OF <br />MAINTENANCE SHALL BE ESTABLISHED BY THE OWNER. THIS PROGRAM SHALL INCLUDE <br />ITEMS SUCH AS, BUT NOT LIMITED TO, PAINTING OF STRUCTURAL STEEL, PROTECTIVE <br />COATINGS FOR CONCRETE, SEALANTS, CAULKED JOINTS, EXPANSION JOINTS, CONTROL <br />JOINTS, SPALLS AND CRACKS IN CONCRETE, AND PRESSURE WASHING OF EXPOSED <br />STRUCTURAL ELEMENTS EXPOSED TO SALT ENVIRONMENT OR OTHER HARSH CHEMICALS. <br />12. STRUCTURAL ENGINEER OF RECORD IS NOT RESPONSIBLE FOR THE DESIGN OF STEEL <br />STAIRS, HANDRAILS, CURTAIN WALLIWINDOW WALL SYSTEMS, COLD -FORMED FRAMING, OR <br />OTHER SYSTEMS NOT SHOWN IN THE STRUCTURAL DOCUMENTS. SUCH SYSTEMS SHALL BE <br />DESIGNED, FURNISHED, AND INSTALLED AS REQUIRED BY OTHER PORTIONS OF THE <br />CONTRACT DOCUMENTS. <br />13. IN THE PROFESSIONAL OPINION OF TLC ENGINEERING FOR ARCHITECTURE, INC. THE <br />STRUCTURAL CONTRACT DOCUMENTS FOR THIS PROJECT HAVE BEEN PREPARED IN <br />ACCORDANCE WITH THE DESIGN CRITERIA AS SET FORTH IN THE FLORIDA BUILDING <br />CODE. <br />14. NO PROVISIONS HAVE BEEN MADE FOR VERTICAL OR HORIZONTAL EXPANSION. <br />15. FINISH FIRST FLOOR ELEVATION OF 0"-0" IS USED AS A REFERENCE ELEVATION. <br />SEE CIVIL DRAWINGS FOR ACTUAL ELEVATION. <br />16. THE USE OF REPRODUCTIONS OF THESE CONTRACT DOCUMENTS AND USE OF CAD FILES BY <br />ANY CONTRACTOR, SUBCONTRACTOR, ERECTOR, FABRICATOR OR MATERIAL SUPPLIER IN <br />LIEU OF PREPARATION OF SHOP DRAWINGS SIGNIFY HIS ACCEPTANCE OF ALL <br />INFORMATION SHOWN HEREON AS CORRECT, AND OBLIGATES HIMSELF TO ANY JOB <br />EXPENSE, REAL OR IMPLIED, ARISING DUE TO ANY ERRORS THAT MAY OCCUR HEREON. <br />1060 DESIGN LOADS: <br />1. THE STRUCTURAL SYSTEM FOR THIS BUILDING HAS BEEN DESIGNED IN ACCORDANCE WITH <br />THE FLORIDA BUILDING CODE, 2014 EDITION. <br />2. THE FOLLOWING SUPERIMPOSED LOADINGS HAVE BEEN UTILIZED: <br />2.1 DEAD LOADS <br />ROOF 20 PSF <br />CEILING 5 PSF <br />MECHANICAL 5 PSF <br />FINISHES 5 PSF <br />2.2 LIVE LOADS <br />ROOF <br />FLOOR <br />20 PSF <br />100 PSF <br />2.3 WIND: PER 2014 BUILDING CODE, SECTION 16 and ASCE 7-10 <br />Vult = 146 MPH (3 SEC. GUST) REGION <br />Vasd = 113 MPH <br />RISK CATEGORY IV <br />EXPOSURE = B <br />1330 SHOP DRAWING REVIEW: <br />1. SHOP DRAWINGS SHALL ADEQUATELY DEPICT THE STRUCTURAL ELEMENTS AND CONNECTIONS <br />SHOWN ON THE CONTRACT DOCUMENTS. SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL <br />COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL <br />BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY COMPLIANCE WITH THE <br />CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. <br />REVIEW OF SUBMITTALS AND SHOP DRAWINGS DOES NOT RELIEVE THE CONTRACTOR OF <br />FULL RESPONSIBILITY FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION <br />OF THE SHOP DRAWINGS. <br />2. SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR AND MARKED "APPROVED" PRIOR <br />TO SUBMITTAL TO THE ARCHITECT/ENGINEER. NON -CONFORMING DRAWINGS SUBMITTALS <br />WILL BE RETURNED WITHOUT REVIEW. <br />3. SHOP DRAWING SUBMITTALS SHALL INCLUDE ONE GOOD QUALITY REPRODUCIBLE AND THREE <br />SETS OF BLUEPRINTS. ONE SET OF PRINTS WILL BE RETAINED BY THE ENGINEER OF <br />RECORD, ONE BY THE ARCHITECT, ONE BY THE LOCAL BUILDING DEPARTMENT (WHERE <br />REQUIRED) AND THE CONTRACTOR SHALL MAKE PRINTS FROM THE REPRODUCIBLE AS <br />REQUIRED FOR DISTRIBUTION. <br />4. THE CONTRACT DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS UNLESS OTHERWISE <br />SPECIFIED IN WRITING BY THE ENGINEER OF RECORD. <br />5. CHANGES AND ADDITIONS MADE ON RE -SUBMITTALS SHALL BE CLEARLY FLAGGED AND <br />NOTED. THE PURPOSE OF THE RE -SUBMITTALS SHALL BE CLEARLY NOTED ON THE LETTER <br />OF TRANSMITTAL. ARCHITECT/ENGINEER OF RECORD REVIEW WILL BE LIMITED TO THOSE <br />ITEMS CAUSING THE RE -SUBMITTAL. CONTRACTOR IS RESPONSIBLE FOR COSTS CAUSED <br />BY MULTIPLE RE -SUBMITTALS (MORE THAN ONE) AT ARCHITECT/ENGINEERS' CURRENT <br />3302 CONCRETE: <br />1. SHALL BE PER AN APPROVED MIX DESIGN PROPORTIONED TO ACHIEVE A STRENGTH AT 28 <br />DAYS AS LISTED BELOW WITH A PLASTIC AND WORKABLE MIX: <br />LOCATION STRENGTH SLUMP MAX AGGREGATE WCM RATIO (MAX) <br />FOUNDATIONS 4000 PSI 4-6" 3/4" 0.48 <br />SLABS ON GRADE 4000 PSI 4-6" 3/4" 0.48 <br />2. CONCRETE SHALL BE PLACED AND CURED ACCORDING TO ACI STANDARDS AND <br />SPECIFICATIONS. <br />3. WHERE SPECIFIED CONCRETE STRENGTH OF COLUMN IS GREATER THAN THE SPECIFIED <br />SLAB CONCRETE STRENGTH, HIGHER STRENGTH CONCRETE SHALL BE PUDDLED AT THE <br />COLUMN. THE STRENGTH OF PUDDLED CONCRETE SHALL BE AT LEAST 0.72 TIMES THE <br />STRENGTH OF COLUMN CONCRETE PER ACI 318, 10.15. <br />4. SUBMIT PROPOSED MIX DESIGN WITH RECENT FIELD CYLINDER OR LAB TESTS FOR REVIEW <br />PRIOR TO USE. MIX SHALL BE UNIQUELY IDENTIFIED BY MIX NUMBER OR OTHER <br />POSITIVE IDENTIFICATION. MIX SHALL MEET THE REQUIREMENTS OF ASTM C33 FOR <br />COARSE AGGREGATE. <br />5. CONCRETE SHALL COMPLY WITH THE REQUIREMENTS OF ASTM STANDARD C94 FOR <br />MEASURING, MIXING, TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME STAMPED <br />WHEN CONCRETE IS BATCHED. <br />6. THE MAXIMUM TIME ALLOWED FROM THE TIME THE MIXING WATER IS ADDED UNTIL IT IS <br />DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED ONE AND ONE HALF (1-1/2) <br />HOURS. IF FOR ANY REASON THERE IS A LONGER DELAY THAN THAT STATED ABOVE, THE <br />CONCRETE SHALL BE DISCARDED. IT SHALL BE THE RESPONSIBILITY OF THE TESTING <br />LAB TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY <br />NONCOMPLIANCE WITH THE ABOVE. <br />7. SLABS SHALL BE CURED USING A DISSIPATING CURING COMPOUND MEETING ASTM <br />STANDARD C309 TYPE 1-CLASS D AND SHALL HAVE A FUGITIVE DYE. THE COMPOUND <br />SHALL BE PLACED AS SOON AS THE FINISHING IS COMPLETED OR AS SOON AS THE WATER <br />HAS LEFT THE UNFINISHED CONCRETE. SCUFFED OR BROKEN AREAS IN THE CURING <br />MEMBRANE SHALL BE RECOATED DAILY. <br />8. CALCIUM CHLORIDES SHALL NOT BE UTILIZED; OTHER ADMIXTURES MAY BE USED ONLY <br />WITH THE APPROVAL OF THE ENGINEER. <br />9. CONCRETE MIX DESIGNS SHALL INCLUDE A WRITTEN DESCRIPTION INDICATING WHERE <br />EACH PARTICULAR MIX IS TO BE PLACED WITHIN THE STRUCTURE. <br />10. PEA ROCK PUMP MIX USE IS LIMITED TO VERTICAL ELEMENT POURS AND BEAM POURS <br />LESS THAN 60 LINEAR FEET PER POUR. <br />11. CONCRETE DESIGN MIX SUBMITTALS SHALL INCLUDE TESTED, STATISTICAL BACK-UP DATA <br />AS PER CHAPTER 5 OF ACI 318. <br />12. WATER/CEMENT RATIO FOR CONCRETE AT EXTERIOR BALCONIES SHALL NOT EXCEED 0.40 <br />BY WEIGHT. <br />13. WHEN WATER -BASED ADHESIVE ARE BEING USED ON CONCRETE SURFACES THE CONTRACTOR <br />SHALL VERIFY THAT THE WATER CONTENT OF THE CONCRETE IS WITHIN THE ALLOWABLE <br />RANGE BEFORE INSTALLATION <br />5120 STRUCTURAL STEEL: <br />1. STEEL WORK SHALL BE NEW AND CONFORM TO THE AISC SPECIFICATION FOR STRUCTURAL <br />STEEL BUILDINGS. - ALLOWABLE STRESS DESIGN AND LOAD AND RESISTANCE FACTOR <br />DESIGN. <br />2. MATERIAL SHALL CONFORM TO THE FOLLOWING, EXCEPT AS NOTED: <br />WIDE FLANGE SHAPES ASTM A992 (Fy=50 KSI) <br />ANGLES, CHANNELS AND PLATES ASTM A36 (Fy=36 KSI) <br />RECTANGULAR HSS ASTM A500, GRADE B (Fy=46 KSI) <br />HIGH STRENGTH BOLTS ASTM A325 <br />THREADED RODS ASTM A36 (Fy=36 KSI) <br />HEAVY HEX NUTS ASTM A563 <br />HARDENED STEEL WASHERS ASTM F436 <br />DIRECT TENSION INDICATORS ASTM F959, TYPE 325 <br />ANCHOR RODS ASTM F1554 GR. 36 (Fy=36 KSI) <br />HEADED STUD ANCHORS ASTM A108 (Fy=50 KSI) <br />TWIST -OFF TENSION CONTROL BOLTS ASTM F1852 <br />3. CONNECTIONS: <br />A. BOLTS SHALL BE HIGH -STRENGTH, BEARING TYPE. TIGHTEN BY AN AISC APPROVED <br />METHOD. <br />B. WELDING ELECTRODES SHALL BE PER AWS D1.1. RETURN FILLET WELDS FOR <br />FRAMED CONNECTIONS 1/2" AT EACH END. <br />C. FIELD CONNECTIONS SHALL BE MADE WITH 3/4" BOLTS, EXCEPT AS NOTED <br />OTHERWISE. <br />D. DESIGN BEAM CONNECTIONS TO DEVELOP THE REACTIONS SHOWN. IF NOT SHOWN, <br />DESIGN CONNECTIONS TO DEVELOP THE REACTIONS DUE TO THE MAXIMUM ALLOWABLE <br />UNIFORM LOAD FOR THE BEAM SIZE AND SPAN SHOWN, ASSUMING FULL LATERAL <br />SUPPORT PER AISC BEAM (ALLOWABLE UNIFORM LOAD) TABLE VALUE FOR THE <br />CORRESPONDING SPAN, U.N.O. <br />E. DESIGN DIAGONAL BRACING CONNECTIONS TO DEVELOP THE REACTIONS SHOWN. IF <br />REACTIONS ARE NOT SHOWN, DESIGN CONNECTIONS TO DEVELOP FULL TENSION <br />CAPACITY OF THE DIAGONAL BRACING MEMBER. <br />F. CALCULATIONS AND SHOP DRAWINGS FOR STRUCTURAL STEEL CONNECTIONS SHALL BE <br />SUBMITTED FOR APPROVAL PRIOR TO FABRICATION AND SHALL BE SIGNED AND <br />SEALED BY AN ENGINEER REGISTERED IN THE STATE IN WHICH THE PROJECT <br />RESIDES. <br />4. ALL STRUCTURAL STEEL EXPOSED TO EXTERIOR CONDITIONS SHALL BE HOT DIPPED <br />GALVANIZED PER ASTM A123 AND ALL FASTENERS AND HARDWARE SHALL BE HOT DIPPED <br />GALVANIZED PER ASTM A153. <br />5. GROUT UNDER BEARING. PLATES SHALL BE NON-METALLIC, NON -SHRINK TYPE WITH A <br />COMPRESSIVE STRENGTH OF AT LEAST 5,000 PSI IN 28 DAYS. <br />6. COMPOSITE FLOOR MEMBERS ARE DESIGNED TO BE UNSHORED UNLESS OTHERWISE NOTED. <br />THE WEIGHT OF THE WET CONCRETE WILL RESULT IN DEFLECTIONS OF THE SUPPORTING <br />STEEL DECK, BEAMS, AND GIRDERS. ALL OVERRUNS OF CONCRETE QUANTITIES ARE TO <br />BE ANTICIPATED AND INCLUDED IN THE CONTRACTOR'S BID. THE CONTRACTOR SHALL <br />COORDINATE EMBEDDED ITEMS REQUIRED FOR ARCHITECTURAL, STRUCTURAL, AND <br />MECHANICAL ELEMENTS. CONCRETE FLOORS UTILIZING UNSHORED CONSTRUCTION SHALL <br />BE SCREEDED LEVEL. <br />7. SIZE AND SPACING OF CONDUITS IN COMPOSITE SLABS SHALL COMPLY WITH THE <br />REQUIREMENTS OF ASCE 3-91 UNLESS NOTED OTHERWISE ON DRAWINGS. <br />8. LENGTH OF SHEAR STUD CONNECTIONS IN COMPOSITE SLABS SHALL EQUAL THE DEPTH <br />OF THE COMPOSITE DECK PLUS 1-1/2" (U.N.O.). <br />9. IT IS THE INTENTION OF THESE DESIGN DOCUMENTS TO DELEGATE THE DESIGN OF ALL <br />STRUCTURAL STEEL CONNECTIONS TO A QUALIFIED SPECIALTY PROFESSIONAL <br />ENGINEER, REGISTERED IN THE STATE OF FLORIDA. THIS REQUIREMENT EXTENDS TO <br />ALL CONNECTIONS, WITH THE EXCEPTION OF THOSE SPECIFICALLY FULLY DESIGNED IN <br />THE DESIGN DOCUMENTS. IT IS ANTICIPATED THAT PROSPECTIVE STRUCTURAL STEEL <br />FABRICATORS WILL PERFORM NECESSARY INVESTIGATION TO DETERMINE THE FULL <br />IMPACT OF CONNECTION CLEARANCE REQUIREMENTS, AS WELL AS THE POTENTIAL <br />NECESSARY INTRODUCTION OF DOUBLER PLATES, CONTINUITY PLATES, AND/OR WEB <br />FLANGE OR OTHER STIFFENERS PRIOR TO SUBMITTING ANY BID FOR THIS WORK. <br />10. PROVIDE SIGNED AND SEALED CALCULATIONS FOR ALL STRUCTURAL STEEL CONNECTION <br />DESIGN PREPARED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. <br />CALCULATIONS ARE TO BE SUBMITTED SIMULTANEOUSLY WITH CORRESPONDING SUBMITTAL. <br />11. HIGH STRENGTH BOLTS IN BEARING CONDITION SUPPORTING SIMPLE SPAN BEAMS NOT <br />SUBJECT TO AXIAL LOADS MAY BE INSTALLED TO "SNUG TIGHT" CONDITION IF <br />NORMAL, SHORT SLOTTED OR OVERSIZED HOLES ARE USED. THE ENGINEER OF RECORD <br />WILL BE THE ULTIMATE AUTHORITY IN THE USE OF "SNUG TIGHT" BOLTS. <br />12. APPLY FIREPROOFING TO STEEL STRUCTURE CALCULATING THE THICKNESS OF <br />FIREPROOFING BY COMPARING THE ACTUAL MEMBER SIZE TO THE MEMBER SIZE USED IN <br />THE DESIGNATED UL RATING AND ADJUSTING APPROPRIATELY. <br />STRUCTURAL ABBREVIATIONS <br />ABBREV <br />ABBREVIATION <br />ACI <br />AMERICAN CONCRETE INSTITUTE <br />ADD <br />ADDITIVE <br />ADDL <br />ADDITIONAL <br />AFF <br />ABOVE FINISHED FLOOR <br />AISC <br />AMERICAN INSTITUTE OF STEEL CONSTRUCTION <br />AISI <br />AMERICAN IRON AND STEEL INSTITUTE <br />ALT <br />ALTERNATE/ALTERNATIVE <br />ALUM <br />ALUMINUM <br />ARCH <br />ARCHITECTURE/ARCHITECTURAL <br />ASTM <br />AMERICAN SOCIETY OF TESTING MATERIALS <br />AWS <br />AMERICAN WELDING SOCIETY <br />B/ <br />BOTTOM OF <br />BCX <br />BOTTOM CHORD EXTENSION <br />BLDG <br />BUILDING <br />BLK <br />BLOCK <br />BM <br />BEAM <br />BOT <br />BOTTOM <br />BP <br />BASE PLATE/BEARING PLATE <br />BRG <br />BEARING <br />BTWN <br />BETWEEN <br />C <br />CHANNEL <br />CB <br />CONCRETE BEAM <br />CC <br />CONCRETE COLUMN <br />CF <br />CUBIC FEET (FOOT) <br />CIP <br />CAST IN PLACE <br />CJ <br />CONTRACTION JOINT <br />CL <br />CENTERLINE <br />CLR <br />CLEAR/CLEARANCE <br />CM <br />CONCRETE MASONRY <br />CMU <br />CONCRETE MASONRY UNIT <br />CO <br />COMPANY <br />COL <br />COLUMN <br />CONC <br />CONCRETE <br />CONT <br />CONTINUOUS <br />CONN <br />CONNECTION <br />CONST <br />CONSTRUCTION <br />COORD <br />COORDINATE <br />CSJ <br />CONSTRUCTION JOINT <br />CTR <br />CENTER <br />CTRD <br />CENTERED <br />CY <br />CUBIC YARD <br />DEPT <br />DEPARTMENT <br />DET <br />DETAIL <br />DIA <br />DIAMETER <br />DIAG <br />DIAGONAL <br />DIM <br />DIMENSION <br />DIST <br />DISTANCE <br />DL <br />DEAD LOAD <br />DN <br />DOWN <br />DWG <br />DRAWING <br />EA <br />EACH <br />EE <br />EACH END <br />EF <br />EACH FACE <br />EHPA <br />EMERGENCY HURRICANE PROTECTION AREA <br />EJ <br />EXPANSION JOINT <br />ELEC <br />ELECTRIC/ELECTRICAL <br />EL, ELEV <br />ELEVATION <br />ENGR <br />ENGINEER <br />EOD <br />EDGE OF DECK <br />FOR <br />ENGINEER OF RECORD <br />EQ SP <br />EQUAL SPACED <br />ES <br />EACH SIDE <br />EW <br />EACH WAY <br />EXIST <br />EXISTING <br />EXP <br />EXPANSION <br />EXT <br />EXTERIOR <br />F <br />FOUNDATION <br />FD <br />FLOOR DRAIN <br />FDN <br />FOUNDATION <br />FF <br />FINISHED FLOOR <br />FIN <br />FINISH <br />FIN GR <br />FINISH GRADE <br />FLR <br />FLOOR <br />FS <br />FAR SIDE <br />FT <br />FEET/FOOT <br />FTG <br />FOOTING <br />GA <br />GAGE/GAUGE <br />GALV <br />GALVANIZED <br />GB <br />GRADE BEAM <br />GC <br />GENERAL CONTRACTOR <br />GEN <br />GENERAL <br />GL <br />GRID LINE <br />GS <br />GALVANIZED STEEL <br />HD <br />HOT DIPPED <br />HDG <br />HOT DIPPED GALVANIZED <br />HORIZ <br />HORIZONTAL <br />HSA <br />HEADED STUD ANCHOR <br />HSS <br />HOLLOW STRUCTURAL SECTION <br />HT <br />HEIGHT <br />I MOMENT OF INERTIA <br />ID INSIDE DIAMETER <br />I.F. INSIDE FACE <br />IN. INCH <br />INT INTERIOR <br />JST <br />JOIST <br />JT <br />JOINT <br />K <br />KIP (1000 LB) <br />KLF <br />KIPS PER LINEAL FOOT <br />KSI <br />KIPS PER SQUARE INCH <br />KWY <br />KEYWAY <br />LB <br />POUND <br />LGTH <br />LENGTH <br />LL <br />LIVE LOAD <br />LLH <br />LONG LEG HORIZONTAL <br />LLV <br />LONG LEG VERTICAL <br />LONG. <br />LONGITUDINAL <br />LSL <br />LAMINATED STRAND LUMBER <br />LT WT <br />LIGHT WEIGHT <br />LVL <br />LAMINATED VENEER LUMBER <br />MATL <br />MATERIAL <br />MAX <br />MAXIMUM <br />MB <br />MASONRY BEAM <br />MC <br />MISCELLANEOUS CHANNEUMASONRY COLUMN <br />MECH <br />MECHANICAL <br />MET <br />METAL <br />MFR <br />MANUFACTURE/MANUFACTURER <br />MID <br />MIDDLE <br />MIN <br />MINIMUM <br />MISC <br />MISCELLANEOUS <br />MO <br />MASONRY OPENING <br />MPH <br />MILES PER HOUR <br />NGVD <br />NATIONAL GEODETIC VERTICAL DATUM <br />NIC <br />NOT IN CONTRACT <br />NO. <br />NUMBER <br />NS <br />NEAR SIDE <br />NTS <br />NOT TO SCALE <br />OC <br />ON CENTERS <br />OD <br />OUTSIDE DIAMETER <br />O.F. <br />OUTSIDE FACE <br />OPNG <br />OPENING <br />OPP <br />OPPOSITE <br />OSB <br />ORIENTED STRAND BOARD <br />P/C <br />PRECAST CONCRETE/PILE CAP <br />P/T <br />POST TENSIONED <br />PAR <br />PARALLEL <br />PCB <br />PRECAST CONCRETE BEAM <br />PCC <br />PRECAST CONCRETE COLUMN <br />PCF <br />POUNDS PER CUBIC FEET <br />PEMB <br />PRE-ENGINEERED METAL BUILDING <br />PEN <br />PENETRATION <br />P.J. <br />PANEL JOINT CENTERLINE <br />PL <br />PLATE <br />PLF <br />POUNDS PER LINEAR FOOT <br />PLMG <br />PLUMBING <br />PLY. <br />PLYWOOD <br />PREFAB <br />PREFABRICATED <br />PSF <br />POUNDS PER SQUARE FOOT <br />PSI <br />POUNDS PER SQUARE INCH <br />PSL <br />PARALLEL STRAND LUMBER <br />PT <br />PRESSURE TREATED <br />R/W <br />REINFORCED WITH <br />RD <br />ROOF DRAIN <br />REF <br />REFERENCE <br />REINF <br />REINFORCING <br />REQD <br />REQUIRED <br />REV <br />REVISION <br />RTU <br />ROOF TOP UNIT <br />SB <br />SOFFIT BEAM <br />SCHED <br />SCHEDULE <br />S.F. <br />SQUARE FEET <br />SF <br />STRIP FOUNDATION <br />SIM <br />SIMILAR <br />SPC <br />SPACE/SPACES <br />SPECS <br />SPECIFICATIONS <br />SQ <br />SQUARE <br />SS <br />STAINLESS STEEL <br />STD <br />STANDARD <br />STIFF <br />STIFFENER <br />STL <br />STEEL <br />STRUCT <br />STRUCTURAL <br />SYM <br />SYMMETRICAL <br />T/ <br />TOP OF <br />TB <br />TIE BEAM <br />T&B <br />TOP AND BOTTOM <br />TCX <br />TOP CHORD EXTENSION <br />TDS <br />TURN DOWN SLAB <br />TE <br />THICKENED EDGE <br />TEMP <br />TEMPERATURE <br />TENS <br />TENSION <br />THD <br />THREAD/THREADED <br />THK <br />THICK <br />TOL <br />TOLERANCE <br />TRANS <br />TRANSVERSE <br />TS <br />TUBE STEEL <br />T.S. <br />THICKENED SLAB <br />TWF <br />THICKENED WALL FOUNDATION <br />TYP <br />TYPICAL <br />UNO UNLESS NOTED OTHERWISE <br />VERT <br />VERTICAL <br />VOL <br />VOLUME <br />W <br />WIDE FLANGE SECTION <br />W/ <br />WITH <br />W/O <br />WITHOUT <br />WD <br />WOOD <br />WF <br />WALL FOOTING <br />WP <br />WATERPROOF <br />W.P. <br />WORKING POINT <br />WS <br />WELDED STUD <br />WT <br />WEIGHT/STRUCTURAL TEE SECTION <br />WWF <br />WELDED WIRE FABRIC <br />AT DESIGNATION <br /># <br />POUNDS / REBAR SIZE NUMBER <br />+/- <br />PLUS OR MINUS <br />L <br />ANGLE <br />C.L. <br />CENTER LINE <br />& <br />AND <br />Sx <br />SECTION MODULUS <br />Ix <br />MOMENT OF INERTIA <br />ENGINEERING <br />FOR ARCHITECTURE <br />500 N. Westshore Blvd., Ste. 435 <br />Tampa, Florida 33609 <br />PH: 813.281.8435 <br />Fax: 813.637.0013 <br />www.tic-engineers.com <br />COA 15 <br />© Copyright 2013 TLC Engineering for Architecture, Inc. <br />�t <br />L <br />LO <br />co <br />cM <br />LL <br />ce <br />NCL <br />4) <br />ICUICUN <br />.Q <br />^Q, <br />�nW// <br />m <br />0 <br />L.L <br />cc <br />CU <br />O <br />OI,,- <br />L <br />_0 <br />LL <br />Revisions: <br />No. Date Description <br />Seal <br />David Fusco, P.E. <br />Florida License #74504 <br />\�\\11111111/// <br />� F U C <br />\� �D S <br />�P' E O <br />*, <br />.7450 <br />STAT OF <br />i FCOR\OP• G� ` <br />Project No.: <br />715128 <br />Issue Date: <br />12/10/2015 <br />Drawn By: <br />RSZ <br />Approved By: <br />DAF <br />Scale: <br />3/32" = V-0" <br />Drawing Title: <br />STRUCTURAL <br />NOTES <br />AND ABBREVIATIONS <br />Drawing No.: <br />S 1.0 <br />THIS DRAWING IS BEING RELEASED FOR PERMIT <br />