N <br />8 <br />Is <br />0 <br />N <br />N <br />Go <br />DUCTWORK <br />® UP _X DN <br />SUPPLY DUCT (UP & DOWN) <br />® UP DN <br />EXHAUST DUCT (UP & DOWN) <br />UP L�y DN <br />RETURN AIR DUCT (UP & DOWN) <br />Y <br />CEILING DIFFUSERS/GRILLES (DOUBLE LINE) <br />+> <br />SIDE WALL REGISTER OR GRILLE (DOUBLE LINE) <br />1Ox8 <br />NEW DUCT - WIDTH x DEPTH (DOUBLE LINE) <br />1ox8 <br />NEW DUCT - WIDTH x DEPTH (SINGLE LINE) <br />EXISTING DUCT TO REMAIN (DOUBLE LINE) <br />t- - - - - - - - - - q <br />EXISTING DUCT TO REMAIN (SINGLE LINE) <br />m7=j�M <br />EXISTING DUCT TO BE REMOVED (DOUBLE LINE) <br />EXISTING DUCT TO BE REMOVED (SINGLE LINE) <br />FLEXIBLE DUCTWORK (INSULATED) <br />DUCT TRANSITION - CONCENTRIC (DOUBLE LINE) <br />DUCT TRANSITION - ECCENTRIC (DOUBLE LINE) <br />DUCT TRANSITION - RECT. TO RND (DOUBLE LINE) <br />MANUAL VOLUME DAMPER (DOUBLE LINE) <br />I <br />MANUAL VOLUME DAMPER (SINGLE LINE) <br />BACK DRAFT DAMPER <br />R <br />INCLINED RISE, IN DIRECTION OF AIR FLOW (DOUBLE LINE) <br />INCLINED DROP, IN DIRECTION OF AIR FLOW (DOUBLE LINE) <br />11J.D III <br />_ D _ <br />FLEXIBLE CONNECTION (DOUBLE LINE) <br />DUCT MOUNTED COIL/HEATER (DOUBLE LINE) <br />VANED ELBOW (PROVIDE ALL SQUARE OR RECTANGULAR <br />ELBOWS WITH TURNING VANES EVEN IF SYMBOL IS MISSING) <br />VANED RADIUS ELBOW (PROVIDE ALL SQUARE OR <br />RECTANGULAR ELBOWS WITH TURNING VANES EVEN IF <br />SYMBOL IS MISSING) <br />ACOUSTICALLY LINED DUCT <br />r <br />VANE TURN ELBOW & AIR SPLIT TYPE DUCT TAKE -OFF <br />(DOUBLE LINE) <br />AIR FLOW CFM <br />10 q <br />AIR DEVICE TYPE (EX = Existing) <br />6" <br />AIR DEVICE NECK SIZE <br />TO <br />THERMOSTAT / TEMPERATURE SENSOR <br />0 <br />HUMIDISTAT / HUMIDITY SENSOR <br />A AIR DEVICE TYPE (EX = Existing) <br />18> ----DOOR GRILLE (18" x12" U.O.N.) <br />AIR DEVICE SIZE <br />-LH <br />DOOR UNDERCUT (1" U.O.N.) <br />TO <br />EXHAUST FAN <br />AIR DEVICES <br />B 2-WAY AIR FLOW <br />® 4-WAY AIR FLOW <br />e 1-WAY AIR FLOW <br />® 3-WAY AIR FLOW <br />FLEX DUCT <br />0 - <br />100 <br />CFM = <br />6"0 <br />101 - <br />160 <br />CFM = <br />7"0 <br />161 - <br />200 <br />CFM = <br />8"0 <br />201 - <br />325 <br />CFM = <br />10"0 <br />326 - <br />400 <br />CFM = <br />12"0 <br />401 - <br />640 <br />CFM = <br />14"0 <br />641 - <br />700 <br />CFM = <br />16"0 <br />DRAWING SYMBOLS <br />1 SECTION NUMBER <br />2 3 DRAWING NUMBER WHERE DRAWN <br />DRAWING NUMBER WHERE CUT <br />`0 POINT OF DEMOLITION <br />POINT OF NEW CONNECTION <br />ll(>__► POINT OF INTERFACE BETWEEN <br />CONTRACTORS <br />® KEYED NOTES <br />MECHANICAL GENERAL NOTES <br />1. DUCT DIMENSIONS SHOWN ON THE DRAWINGS ARE CLEAR INSIDE AIR PASSAGE DIMENSIONS. <br />2. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 8'-0'. <br />3. INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS AND RECOMMENDATIONS. <br />4. CONTRACTOR TO PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND MECHANICAL EQUIPMENT AND MATERIALS. <br />5. MOUNT ALL SPACE THERMOSTATS AND/OR SENSORS 4 FEET ABOVE THE FLOOR, UNLESS OTHERWISE NOTED. <br />6. SEE ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS OF MECHANICAL EQUIPMENT. <br />7. UNLESS OTHERWISE NOTED, INSTALL ALL DUCTWORK AS HIGH AS POSSIBLE, TIGHT TO THE BOTTOM OF THE STRUCTURE. <br />COORDINATE ELEVATION AND LOCATION WITH RAIN LEADERS, WATER PIPING, PLUMBING VENTS, AND MAJOR ELECTRICAL <br />CONDUITS OR CABLE TRAY. <br />8. ALL WORK IS TO BE FREE OF DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE (1) YEAR FROM DATE OF <br />FINAL ACCEPTANCE. ALL DEFECTS WHICH DEVELOP OR ARE DISCOVERED WITHIN THIS PERIOD SHALL BE REPAIRED BY THE <br />CONTRACTOR TO THE SATISFACTION OF THE OWNER AT NO ADDITIONAL COST TO THE OWNER. <br />9. THE CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADES IN ORDER TO AVOID CONFLICTS. <br />10. SUPPORT DUCTS PER SMACNA. _ <br />nr r n dvn. Q <br />12. ROUTE ALL DUCTWORK, PIPING, ACCESSORIES AS NECESSARY TO AVOID BUILDING STRUCTURE, COMPONENTS AND 1 <br />LIGHTING. COORDINATE ANY TRANSITIONS MADE TO DUCTWORK WITH MAXIMUM FAN PRESSURE DROP REQUIREMENTS <br />FROM MANUFACTURER. ROUTE/SIZE ALL REFRIGERANT PIPING PER MANUFACTURER'S RECOMMENDATIONS. <br />13. ALL DIMENSIONS ARE APPROXIMATE. DO NOT SCALE DRAWINGS FOR CONSTRUCTION. <br />14. ALL FINISHED WORK SHALL BE FREE OF DEFECTS WITH EXISTING SURFACES MAINTAINED IN THE SAME CONDITION AS ORIGINAL. <br />15. ALL DEBRIS SHALL BE PROPERLY DISPOSED OF OFF SITE. <br />16. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FIRE RATING AND WEATHERPROOFING INTEGRITY OF ALL PIPING <br />AND DUCT PENETRATIONS. <br />17. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY SUPPORTING DEVICES FOR ALL ACCESSORIES <br />INCLUDED IN CONTRACT OR HEREIN SPECIFIED OR OTHERWISE. <br />18. THE WORK INDICATED ON THESE DRAWINGS IS GENERALLY DIAGRAMMATIC AND IS INTENDED TO CONVEY THE SCOPE OF <br />WORK AND INDICATE THE GENERAL ARRANGEMENT OF DUCTWORK AND EQUIPMENT, ETC. <br />19. THE ENGINEER HAS MADE AN EXTENSIVE EFFORT TO IDENTIFY ABOVE CEILING CONFLICTS. THE CONTRACTOR IS RESPONSIBLE <br />TO CHECK FIELD CONDITIONS PRIOR TO BIDDING AND REPORT ANY PROBLEMS/CONFLICTS TO THE ENGINEER WITHIN 2 DAYS <br />OF DISCOVERY. ANY CHANGES RESULTING FROM CONDITIONS ARISING IN THE FIELD WHICH WERE NOT BROUGHT TO THE <br />ENGINEER'S ATTENTION ARE TO BE MADE BY THIS CONTRACTOR WITH NO ADDITIONAL COST TO THE OWNER. <br />20. ALL ROOF ATTACHED EQUIPMENT AND APPURTENANCES INCLUDED IN THE SCOPE OF THIS PROJECT ARE REQUIRED TO BE <br />SECURED TO THE UNDERLYING BUILDING STRUCTURE. THE FASTENING SYSTEMS SHALL BE INSTALLED TO RESIST THE <br />WIND PRESSURES ON THE EQUIPMENT AS DETERMINED IN ACCORDANCE WITH THE CURRENT BUILDING CODE. <br />21. WAC WORK CONSISTS OF PROVIDING AIR CONDITIONING SYSTEMS FOR A COMPLETE OPERATING SYSTEM AS INDICATED ON <br />THE DRAWINGS. ALL WORK SHALL COMPLY WITH APPLICABLE CODES IN SPECIFICATIONS. IT IS THE INTENTION OF THE <br />CONTRACT DRAWINGS AND SPECIFICATION TO CALL FOR COMPLETE, FINISHED WORK, TESTED, AND READY FOR OPERATION. <br />ABBREVIA11ONS <br />AC <br />AIR CONDITIONING <br />EQUIP <br />EQUIPMENT <br />NIC <br />NOT IN CONTRACT <br />AD <br />ACCESS DOOR <br />EXIST <br />EXISTING <br />NO <br />NORMALLY OPEN <br />AFF <br />ABOVE FINISHED FLOOR <br />ESP <br />EXTERNAL STATIC PRESSURE <br />PD <br />PRESSURE DROP <br />AHU <br />AIR HANDLING UNIT <br />FCU <br />FAN COIL UNIT <br />PRESS <br />PRESSURE <br />AP <br />ACCESS PANEL <br />FD <br />FLOOR DRAIN <br />RA <br />RETURN AIR <br />BF <br />BELOW FINISHED FLOOR <br />FL <br />FLOOR <br />BHP <br />BRAKE HORSE POWER <br />FM <br />FACTORY MUTUAL <br />RG <br />REFRIGERANT <br />BOT <br />BOTTOM <br />FPI <br />FINS PER INCH <br />RLA <br />RUNNING LOAD AMPS <br />BTUH <br />BRITISH THERMAL UNIT <br />FPF <br />FINS PER FOOT <br />RPM <br />REVOLUTIONS PER MINUTE <br />RTU <br />ROOF TOP UNIT <br />PER HOUR <br />FPM <br />FEET PER MINUTE <br />SD <br />SMOKE DETECTOR <br />CC <br />COOLING COIL <br />GSD <br />FIRE/SMOKE DAMPER <br />CD <br />CONDENSATE DRAIN <br />NATURAL GAS <br />SA <br />SUPPLY AIR <br />CFM <br />CUBIC FEET PER MINUTE <br />GPH <br />GALLONS PER HOUR <br />SP <br />STATIC PRESSURE <br />CLG <br />CEILING <br />GPM <br />GALLONS PER MINUTE <br />STRICT <br />STRUCTURAL <br />CU <br />CONDENSING UNIT <br />H <br />HUMIDITY <br />SYS <br />SYSTEM <br />DB <br />DRY BULB <br />HC <br />HEATING COIL <br />T <br />TEMPERATURE <br />DG <br />DOOR GRILLE <br />HP <br />HORSE POWER <br />TSP <br />TOTAL STATIC PRESSURE <br />DP <br />DEW POINT <br />HVU <br />HEATING AND VENTILATING UNIT <br />TYP <br />TYPICAL <br />DX <br />DIRECT EXPANSION <br />KW <br />KILOWATT <br />UC <br />UNDERCUT <br />EA <br />EXHAUST AIR <br />LAT <br />LEAVING AIR TEMPERATURE <br />UG <br />UNDERGROUND <br />EAT <br />ENTERING AIR TEMPERATURE <br />LRA <br />LOCKED ROTOR AMPS <br />UL <br />UNDERWRITERS LABORATORY <br />EDH <br />ELECTRIC DUCT HEATER <br />LWT <br />LEAVING WATER TEMPERATURE <br />LION <br />UNLESS OTHERWISE NOTED <br />EER <br />ENERGY EFFICIENCY RATIO <br />MAX <br />MAXIMUM <br />W <br />UNIT VENTILATOR <br />VD <br />VOLUME DAMPER <br />EF <br />EXHAUST FAN <br />MIN <br />MINIMUM <br />WB <br />WET BULB <br />EL <br />ELEVATION <br />NC <br />NORMALLY CLOSED <br />PIPING <br />z-���f��/ff�f/f ,t PIPING TO BE REMOVED • rI <br />VALVE IN RISER <br />z-----------z EXISTING PIPING TO REMAIN 2 <br />DIRECTION OF FLOW <br />REFRIGERANT PIPING <br />REDUCER OR INCREASER <br />2 - z DOMESTIC WATER 9 <br />ECCENTRIC REDUCER <br />GATE VALVE r <br />TOP CONNECTION, 45 OR 90 DEG. <br />GLOBE VALVE x <br />' <br />BOTTOM CONNECTION, 45 OR 90 DEG. <br />CHECK VALVE r <br />, <br />z SIDE CONNEC1ON <br />--i¢F-z BALL VALVE <br />CAPPED OUTLET <br />r---���-� BUTTERFLY VALVE <br />PRESSURE REDUCING VALVE <br />DROP IN PIPING <br />SAFETY OR PRESSURE 2 0 <br />2 RISE IN PIPING <br />RELIEF VALVE <br />NOTE: <br />M EBE ARE STANDARD SYMBOLS AND CEIER& NOTES AND MAY NOT ALL APPEAR <br />ON TFE PROJECT MAMM HOWEVER ""' TFE SYMML APPEARS ON TM <br />PROJECT MAWIM Tm REM SHALL BE PROMM AND IhWMI ED. <br />SPECIFICATIONS <br />1.0 BASIC MATERIAL AND METHODS <br />1.1 SCOPE OF WORK <br />PROVIDE LABOR AND MATERIALS AS REQUIRED TO PROVIDE A FULLY FUNCTIONING AND COMPLETE SYSTEM AS INDICATED ON <br />DRAWINGS. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND <br />AEQUIPMENT. <br />FINAL LOCATIONS OF EQUIPMENT SHALL BE FIELD DETERMINED. ALL DISCREPANCIES ON DRAWINGS SHALL BE BROUGHT <br />TO THE ATTENTION OF THE ARCHITECT IN WRITING PRIOR TO SUBMISSION OF BIDS. <br />1.2 GENERAL REQUIREMENTS, SPECIAL CONDITIONS AND WARRANTY <br />A. ALL DIVISION 1 SPECIFICATIONS AND ARCHITECTURAL GENERAL AND SPECIAL CONDITIONS OUTLINED IN THE CONTRACT <br />DOCUMENTS APPLY TO MECHANICAL SYSTEMS. ADDITIONALLY, WORK SHIM COMPLY WITH THE 2014 FLORIDA BUILDING <br />CODE, ORDINANCES AND REGULATIONS OF THE LOCAL AUTHORITY HIVING JURISDICTION, NATIONAL FIRE PROTECTION <br />ASSOCIATION AND NATIONAL ELECTRICAL CODE. ADDITIONS, ALTERATION, REFURBISHING, RENOVATIONS TO AN <br />RECONSTRUCTION OF EXISTING HOSPITALS Stall BE IN COMPLIANCE WITH THE FOLLOWING CODES AND STANDARDS: <br />B. 2014 FLORIDA BUILDING CODE <br />C. WAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE, AMERICAN NATIONAL STANDARD/SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION (ANSI/SMACNA 006-2006) <br />D. 2014 FLORIDA FIRE PREVENTION CODE <br />E. HANDICAP ACCESSIBILITY STANDARDS IN CHAPTER 553, PART V, F.S.; <br />F. FEDERAL AMERICANS WITH DISABILITIES ACE; THE FOLLOWING NATIONAL ARE CODES OF THE NATIONAL FIRE PROTECTION <br />ASSOCIATION (NFPA) <br />1. CHAPTER 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE (2015 EDITION); <br />2. CHAPTER 37, INSTALLATION AND USE OF STATIONARY COMBUSTION ENGINES AND GAS TURBINES (2015 EDITION); <br />3. CHAPTER 50, BULK OXYGEN SYSTEMS AT CONSUMER SITES (2001 EDITION); <br />4. CHAPTER 70B, ELECTRICAL EQUIPMENT MAINTENANCE (2013 EDITION); <br />5. CHAPTER 70E, ELECTRICAL SAFETY REQUIREMENTS FOR EMPLOYEE WORKPLACES (2015 EDITION); <br />6. CHAPTER 77, STATIC ELECTRICITY (2014 EDITION); � <br />7. CHAPTER 99B, HYPOBARIC FACILITIES (2015 EDITION); <br />8. CHAPTER 110, STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS (2016 EDITION); <br />9. CHAPTER 170, STANDARD FOR FIRE SAFETY AND EMERGENCY SYMBOLS (2015 EDITION); <br />10. CHAPTER 262, STANDARD METHOD OF TEST FLAME TRAVEL AND SMOKE OF WIRES AND CABLES FOR USE IN AIR <br />HANDLING SPACES (2015 EDITION); <br />11. CHAPTER 498, RECOMMENDED PRACTICE FOR THE CLASSIFICATION 0 FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF <br />(CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS (2012 EDITION); <br />12. CHAPTER 600, STANDARD ON INDUSTRIAL FIRE BRIGADES (2015 EDITION); <br />13. CHAPTER 780, STANDARD FOR THE INSTALLATION OF LIGHTNING PROTECTION SYSTEMS (2014 EDITION); <br />14. CHAPTER 801, STANDARD FOR FIRE PROTECTION FOR FACILITIES HANDLING RADIOACTIVE MATERIALS (2014 EDITION); <br />15. CHAPTER 850, RECOMMENDED PRACTICE FOR FIRE PROTECTION FOR ELECTRIC GENERATING PLANTS AND HIGH <br />VOLTAGE DIRECT CURRENT CONVERTER STATIONS (2015 EDITION); <br />G. FIRE, SMOKE, AND RADIATION DAMPER INSTALLATION GUIDE FOR WAC SYSTEMS (1986), SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, INC. (SMACNA); < <br />H. LOCAL CODES WHICH SET MORE STRINGENT STANDARDS OR ADD ADDITIONAL REQUIREMENTS SHALL TAKE PRECEDENCE <br />> OVER THESE STANDARDS AND REQUIREMENTS AS SET FORTH IN THIS SECTION. CONTACT THE OFFICE OF PLANS AND <br />CONSTRUCTION WHEN CONFLICTS OCCUR. <br />I. ALL EQUIPMENT SHIM CARRY THE UNDERWRITER'S LABORATORIES (UL) OR ELECTRIC TESTING LABS (EL)SEAL WHERE <br />APPLICABLE. CONTRACTOR SHALL PROVIDE A ONE-YEAR PARTS AND LABOR WARRANTY ON ALL EQUIPMENT PROVIDED ON <br />THIS PROJECT. WARRANTY SHALL START ON THE DATE OF SUBSTANTIAL COMPLETION. CONTRACTOR SHALL PURCHASE <br />MANUFACTURER'S WARRANTY FOR ALL REFRIGERATION EQUIPMENT. <br />1.3 <br />UNLESS OTHERWISE NOTED, P CIS, WHERE NO SPECIFIC WEIGHTS OR GRADES ARE SPECIFIED <br />PROVIDE MATERIALS OF AN ACCEPTED STANDARD WEIG D GRADE ACCORDING TO CODE AND GOVERNING STANDARDS BY <br />ASHRAE, SMACNA, NFPA AND UL INSTALL ALL EQUIPMENT, PIPING, DUCTWORK AND CONTROLS IN ACCORDANCE WITH CODES, <br />GOVERNING STANDARDS, AND MANUFACTURER'S RECOMMENDATIONS. FIRE PERFORMANCE CHARACTERISTICS OF INSTALLED MATERIALS <br />SHALL BE RATED IN ACCORDANCE WITH ASTM E84. MAXIMUM SMOKE DEVELOPED RATING SHALL BE 50. SUPPLIED EQUIPMENT <br />SHALL BE AS SCHEDULED OR OWNER APPROVED EQUAL IN QUALITY AND PERFORMANCE. <br />1.4 COORDINATION <br />COORDINATE ALL WORK FOR PROPER LOCATION, POWER, AND UTILITY REQUIREMENTS. SCHEDULE INSTALLATIONS TO AVOID <br />CONFLICT AMONG TRADES. ADDITIONS TO THE CONTRACT FOR COORDINATION AMONG TRADES WILL NOT BE ALLOWED. <br />1.5 PENETRATIONS. CUTTING AND PATCHING <br />SEAL ALL PIPING AND DUCT PENETRATIONS OF WALLS IN ACCORDANCE WITH ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. <br />FLASH ALL ROOF AND WALL PENETRATIONS IN ACCORDANCE WITH ARCHITECTURAL DRAWINGS. PROVIDE FIRE DAMPERS AT ALL <br />RATED PENETRATIONS. <br />1.6 HANGERS AND SUPPORTS <br />PROVIDE HANGERS AND SUPPORTS FOR ALL PIPING, DUCTWORK AND EQUIPMENT IN ACCORDANCE WITH SMACNA, MSS, ASME <br />AND ASHRAE STANDARDS. SUPPORT ALL ITEMS FROM INTEGRAL BUILDING STRUCTURAL MEMBERS. DO NOT HANG ITEMS FROM <br />ROOF DECKING. <br />2.0 CONDENSATE PIPING <br />CONDENSATE PIPES SHALL BE SCH-40 PVC WITH SOLVENT WELDS, SUPPORTED TO BUILDING. PROVIDE CONDENSATE PUMPS IF <br />REQUIRED TO MAINTAIN A PITCH OF 1/8" PER FOOT. REFRIGERANT PIPING SHALL BE TYPE "L" COPPER PIPE. PIPING SHALL BE <br />INSULATED WITH 3/4" THICK ARMAFLEX INSULATION SUITABLE FOR RETURN AIR PLENUMS. ALL ROOF PIPING SHALL BE SECURED <br />TO THE DECK AND DRAIN PIPING CONNECTED INTO A ROOF DRAIN OR GUTTER. PROVIDE P-TRAPS AT UNIT. <br />3.0 SHEET METAL MATERIALS <br />A. SHEET METAL, GENERAL PROVIDE SHEET METAL IN THICKNESSES INDICATED, PACKAGED AND MARKED AS SPECIFIED IN ASTM <br />A 700. <br />B. GALVANIZED SHEET STEEL: LOCK -FORMING QUALITY, ASTM A 527, COATING DESIGNATION G 90. PROVIDE MILL PHOSPHATIZED <br />FINISH FOR EXPOSED SURFACES OF DUCTS EXPOSED TO VIEW. <br />C. REINFORCEMENT SHAPES AND PLATES: UNLESS OTHERWISE INDICATED, PROVIDE GALVANIZED STEEL REINFORCING WHERE <br />INSTALLED ON GALVANIZED SHEET METAL DUCTS. FOR ALUMINUM AND STAINLESS STEEL DUCTS PROVIDE REINFORCING OF <br />COMPATIBLE MATERIALS. <br />D. TIE RODS: GALVANIZED STEEL, 1/4-INCH MINIMUM DIAMETER FOR 36-INCH LENGTH OR LESS; 3/8-INCH MINIMUM DIAMETER <br />FOR LENGTHS LONGER THAN 36 INCHES. <br />3.01 SEALING MATERIALS <br />A JOINT AND SEAM SEALANT: LOW VOC, ONE -PART, NON -SAG, SOLVENT -RELEASE -CURING, POLYMERIZED BUM SEALANT <br />COMPLYING WITH FSTT-S-001657, TYPE I; FORMULATED WITH A MINIMUM OF 75% SOLIDS AND SQAMD RULE 1168. <br />IRON -GRIP 601 OR APPROVED EQUAL (75 G/L (LESS WATER) VOC CONTENT). <br />B. FLANGED JOINT MASTICS: ONE -PART, ACID -CURING, SILICONE ELASTOMERIC JOINT SEALANTS, COMPLYING WITH ASTM C <br />920, TYPE S. GRADE NS, CLASS 25, USE 0. <br />3.02 ARE -STOPPING <br />A. FIRE-RESISTANT SEALANT: PROVIDE ONE -PART ELASTOMERIC SEALANT FORMULATED FOR USE IN A THROUGH -PENETRATION <br />FIRE -STOP SYSTEM FOR FIWNG OPENINGS AROUND DUCT PENETRATIONS THROUGH WALLS AND FLOORS, HAVING <br />FIRE -RESISTANCE RATINGS INDICATED AS ESTABLISHED BY TESTING IDENTICAL ASSEMBLIES PER ASTM E 814 BY <br />UNDERWRITERS LABORATORY, INC. OR OTHER TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING <br />JURISDICTION. <br />B. PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE ONE OF THE FOLLOWING: <br />1. 'DOW CORNING FIRE STOP SEALANT"; DOW CORNING CORP. <br />2. "3M ARE BARRIER CAULK CP_25` ELECTRICAL PRODUCTS DIV./3M. <br />3. " RTV 7403"; GENERAL ELECTRIC CO. <br />4. "FYRE PUTTY"; STANDARD OIL ENGINEERED MATERIALS CO. <br />3.03 HANGERS AND SUPPORTS <br />A. BUILDING ATTACHMENTS: CONCRETE INSERTS, POWDER ACTUATED FASTENERS, OR STRUCTURAL STEEL FASTENERS <br />APPROPRIATE FOR BUILDING MATERIALS. DO NOT USE POWDER ACTUATED CONCRETE FASTENERS FOR LIGHTWEIGHT <br />AGGREGATE CONCRETES OR FOR SLABS LESS THAN 4 INCHES THICK. <br />B. HANGERS: GALVANIZED SHEET STEEL, OR ROUND, STEEL, THREADED ROD. <br />1. HANGERS INSTALLED IN CORROSIVE ATMOSPHERES: ELECTRO-GALVANIZED, ALL -THREAD ROD OR <br />HOT -DIPPED -GALVANIZED RODS WITH THREADS PAINTED AFTER INSTALLATION. <br />2. STRAPS AND ROD SIZES: CONFORM WITH TABLE 4_1 IN SMACNA WAC DUCT CONSTRUCTION STANDARDS, <br />1985 EDITION, FOR SHEET STEEL WIDTH AND GAGE AND STEEL ROD DIAMETERS. <br />C. DUCT ATTACHMENTS: SHEET METAL SCREWS, BLIND RIVETS, OR SELF_ TAPPING METAL SCREWS; COMPATIBLE WITH DUCT <br />MATERIALS. <br />D. TRAPEZE AND RISER SUPPORTS: STEEL SHAPES CONFORMING TO ASTM A 36. <br />1. WHERE GALVANIZED STEEL DUCTS ARE INSTALLED, PROVIDE HOT -DIPPED- GALVANIZED STEEL SHAPES AND PLATES. <br />MECHANICAL <br />M1.0 ABBREVIATIONS, LEGENDS AND GENERAL NOTES <br />M2.0 INFECTION CONTROL PLAN <br />M3.0 WAC 1 ST FLOOR PLAN - DEMOLITION <br />M4.0 WAC 1 ST FLOOR PLAN - NEW CONSTRUCTION <br />M4.1 WAC 2ND FLOOR PLAN - NEW CONSTRUCTION <br />PLAN - NEW CONSTRUCTION <br />M4.3 WAC MOBILE M <br />SCHEDULE & DETAILS <br />M5.1 AIR BALANCE TABLE <br />src:cF-IcnnoNs - CONTHUED <br />3.04 RECTANGULAR DUCT FABRICATION <br />A. GENERAL: EXCEPT AS OTHERWISE INDICATED, FABRICATE RECTANGULAR DUCTS WITH GALVANIZED SHEET STEEL, IN <br />ACCORDANCE WITH SMACNA 'HVAC DUCT CONSTRUCTION STANDARDS," TABLES 13 THROUGH 119, INCLUDING THEIR <br />ASSOCIATED DETAILS. CONFORM TO THE REQUIREMENTS IN THE REFERENCED STANDARD FOR METAL THICKNESS, <br />REINFORCING TYPES AND INTERVALS, TIE ROD APPLICATIONS, AND JOINT TYPES AND INTERVALS. <br />1. FABRICATE RECTANGULAR DUCTS IN LENGTHS APPROPRIATE TO REINFORCEMENT AND RIGIDITY CLASS REQUIRED <br />FOR PRESSURE CLASSIFICATION. <br />2. PROVIDE MATERIALS THAT ARE FREE FROM VISUAL IMPERFECTIONS SUCH AS PITTING, SEAM MARKS, ROLLER MARKS, <br />STAINS, AND DISCOLORATION& <br />B. FABRICATE KITCHEN HOOD EXHAUST DUCTS WITH 16_GAGE, CARBON STEEL SHEETS FOR CONCEALED DUCTS AND 18_GAGE <br />STAINLESS STEELS FOR EXPOSED DUCTS. WELD AND FLANGE SEAMS AND JOINTS LIQUID TIGHT. CONFORM TO NFPA <br />STANDARD 96. <br />C. FABRICATE DISHWASHER HOOD EXHAUST DUCTS WITH 18_GAGE STAINLESS STEELS. WELD AND FLANGE SEAMS AND JOINTS. <br />D. STATIC PRESSURE CLASSIFICATIONS: EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING <br />PRESSURE CLASSIFICATIONS: <br />1. SUPPLY DUCTS: 3 INCHES WATER GAGE. <br />2. RETURN DUCTS: 2 INCHES WATER GAGE, NEGATIVE PRESSURE. <br />3. EXHAUST DUCTS: 2 INCHES WATER GAGE, NEGATIVE PRESSURE. <br />E. CROSSBREAKING OR CROSS BEADING: CROSSBREAK OR BEAD DUCT SIDES THAT ARE 19 INCHES AND LARGER AND ARE <br />20 GAGE OR LESS, WITH MORE THAN 10 SQ. FT. OF UNBRACED PANEL AREA, AS INDICATED IN SMACNA -WAC DUCT <br />CONSTRUCTION STANDARD." <br />3.05 RECTANGULAR DUCT FITTINGS <br />A. FABRICATE ELBOWS, TRANSITIONS, OFFSETS, BRANCH CONNECTIONS, AND OTHER DUCT CONSTRUCTION IN ACCORDANCE <br />WITH SMACNA "HVAC METAL DUCT CONSTRUCTION STANDARD," 1985 EDITION, FIGURES 2_1 THROUGH 2_10. <br />3.1 FLEXIBLE DUCTS <br />A. GENERAL: COMPLY WITH UL 181, CLASS 1. <br />B. FLEXIBLE DUCTS - INSULATED: FACTORY -FABRICATED, INSULATED, ROUND DUCT, WITH AN OUTER JACKET ENCLOSING GLASS <br />FIBER (R-4.2, 1" THICK IN CONDITIONED AREAS, R-6.0, 1-1/2" THICK IN NON -CONDITIONED SPACES) INSULATION AROUND A <br />CONTINUOUS INNER LINER. DUCTING RATED FOR 3/4" NEGATIVE PRESSURE. <br />1. REINFORCEMENT: STEEL -WIRE HELIX ENCAPSULATED IN THE INNER LINER. <br />2. OUTER JACKET: GLASS -REINFORCED, SILVER MYLAR WITH A CONTINUOUS HANGING TAB, INTEGRAL FIBER GLASS <br />TAPE, AND NYLON HANGING CORD. <br />3. INNER LINER: POLYETHYLENE FILM. <br />3.2 FLEXIBLE CONNECTIONS <br />PROVIDE FLEXIBLE CONNECTIONS AT ALL EQUIPMENT CONNECTIONS. SHALL BE INSTALLED WITH A MINIMUM CLEARANCE <br />TO THE APPLIANCE AS SPECIFIED IN THE APPLIANCE'S INSTALLATION INSTRUCTIONS. <br />3.3 AIR DUCTS - EXHAUST AIR <br />SMACNA LOW PRESSURE CLASS GALVANIZED SHEET METAL DUCT SYSTEM WITH LOCK FORMING QUALITY. (SNAP -LOCK IS OK) <br />3.4 REINFORCEMENT <br />A. CHANNEL REINFORCEMENT: GALVANIZED -STEEL CHANNELS FABRICATED FROM ASTM A 527 AND HAVING G 60 OR G 90 <br />ZINC COATING WEIGHT. REFER TO FGDCS FOR CHANNEL SIZES AND SPACING. <br />B. TIE RODS REINFORCEMENT: 12-GAGE, GALVANIZED -STEEL WIRE, LENGTH TO SUIT TERMINATION METHOD. REFER TO FGDCS <br />FOR ROD SIZES AND SPACING. <br />C. REINFORCING ROD WASHERS: 2-1/2 INCHES SQUARE BY 0.028 INCHES THICK MINIMUM OR 0.020 INCHES THICK TO SUIT <br />TERMINATION METHOD, GALVANIZED -STEEL WASHER WITH TURNED EDGES. <br />D. INSTALL ANTI -SAG DEVICES IN DUCTS 48 INCHES WIDE AND LARGER. <br />E. FOR NEGATIVE PRESSURE DUCTS, FASTEN REINFORCING CHANNELS THROUGH DUCTS TO 2-INCH, BY 6-INCH, BY 20-GAGE <br />GALVANIZED -STEEL CUPS AT TRANSVERSE JOINTS AND 2-1/2-INCH-SQUARE GALVANIZED -STEEL WASHERS AT INTERMEDIATE <br />REINFORCEMENT. REFER TO SCHEDULES IN THE FGDCS FOR QUANTITIES. <br />3.5 CLOSURE <br />A. MATERIALS: SELECT ONE OF THE FOLLOWING CLOSURE MATERIALS AS RECOMMENDED BY THE FIBROUS GLASS DUCT <br />MANUFACTURER: <br />1. PRESSURE -SENSITIVE TAPE: A MINIMUM OF 2-1/2 INCHES WIDE, FIBER GLASS -REINFORCED, ALUMINUM FOIL TAPE <br />COMPLYING WITH UL STANDARD 181A, PART P, AND IMPRINTED WITH THE REQUIRED INFORMATION. <br />2. HEAT -ACTIVATED TAPE: A MINIMUM OF 2-1/2 INCHES WIDE, FIBER GLASS -REINFORCED, FOIL/SCRIM TAPE <br />COMPLYING WITH UL STANDARD 181A, PART H, AND IMPRINTED WITH THE REQUIRED INFORMATION. <br />3. MASTIC AND GLASS FABRIC: A MINIMUM OF 3 INCHES WIDE, GLASS FABRIC AND DUCT MANUFACTURER'S <br />RECOMMENDED MASTIC THAT COMPLIES WITH UL STANDARD 181. <br />3.6 HANGING AND SUPPORTING <br />A. INSTALL UPPER ATTACHMENTS TO STRUCTURES WITH AN ALLOWABLE LOAD NOT EXCEEDING 1/4 OF THE FAILURE (PROOF TEST) LO <br />B. INSTALL CONCRETE INSERT BEFORE PLACING CONCRETE. <br />C. INSTALL POWDER -ACTUATED CONCRETE FASTENERS AFTER CONCRETE IS PLACED AND COMPLETELY CURED. <br />D. DUCT ATTACHMENT: SUPPORT HORIZONTAL DUCTS WITH TRAPEZE -TYPE HANGERS. <br />E. HANGER: SUSPEND DUCT ATTACHMENT FROM BUILDING ATTACHMENT WITH 1 OF THE FOLLOWING HANGER TYPES: <br />1. GALVANIZED -SHEET METAL STRIP, A MINIMUM OF 22 GAGE BY I INCH WIDE. <br />2. GALVANIZED -STEEL ROD, 1/4 INCH DIAMETER, THREADED ITS ENTIRE LENGTH. <br />3. GALVANIZED -STEEL WIRE, 12 GAGE MINIMUM. <br />F. ATTACH HANGERS TO JOINT AND REINFORCEMENT CHANNELS THAT OCCUR WITHIN THE REQUIRED HANGER SPACING. ATTACH <br />HANGERS TO TRANSMIT LOAD TO THE SIDES AND BOTTOM CHANNELS AND NO MORE THAN 6 INCHES FROM SIDES OF DUCT. <br />G. SUPPORT EQUIPMENT AND METAL DUCT COMPONENTS AND ACCESSORIES INDEPENDENT FROM DUCT. <br />H. SUPPORT TERMINAL COMPONENTS SEPARATELY. <br />I. INSTALL SHEET -METAL SLEEVE TO SUPPORT DAMPERS. EXTEND SLEEVE FOR MOTORIZED DAMPERS TO SUPPORT OPERATOR. <br />4.0 AIR DEVICES <br />PROVIDE AIR DEVICES AS PER AIR DEVICE SCHEDULE. SUBSTITUTIONS MAY BE SUBMITTED FOR PRIOR APPROVAL <br />4.1 FLEXIBLE CONNECTIONS <br />PROVIDE FLEXIBLE CONNECTIONS AT ALL EQUIPMENT CONNECTIONS. SHALL BE INSTALLED WITH A MINIMUM CLEARANCE <br />TO THE APPLIANCE AS SPECIFIED IN THE APPLIANCE'S INSTALLATION INSTRUCTIONS. <br />4.2 INSULATIO <br />INSULATE ALL GALVANIZED STEEL SUPPLY AND RETURN AIR DUCTWORK. EXHAUST DUCTS SHALL NOT BE INSULATED, EXCEPT <br />INTERNALLY LINED WITH INSULATION 10 FEET OF DUCTWORK ATTACHED TO AND INCLUDING THE DISCHARGE PLENUMS AT EXHAUST <br />LOUVERS FOR NOISE CONSIDERATIONS. INSULATE OUTSIDE AIR INTAKE DUCTS TO OUTSIDE AIR OPENING. <br />DUCT WRAP SHALL BE SPECIFICALLY DESIGNED FOR WRAPPING HEATING AND AIR CONDITIONING DUCTWORK AND INCLUDE 2" OVERLAP <br />FACING TAB TO PROVIDE FOR CONTINUOUS VAPOR SEAL DUCT WRAP SHALL BE 2' THICK, 1.5 LB. DENSITY, FOIL_SCRIM_KRAFT <br />LAMINATED VAPOR BARRIER FACING, MINIMUM INSTALLED R_VALUE EQUAL TO 6.4, AND A MAXIMUM FLAME SPREAD/SMOKE <br />DEVELOPMENT RATING OF 25/50 PER ASTM E84. <br />INSULATE HVAC PLENUMS AND UNIT HOUSINGS NOT PRE -INSULATED AT FACTORY OR LINED WITH 2' THICK DUCT WRAP. <br />INSULATE ALL EXPOSED METAL SURFACES ON BACK OF CEILING DIFFUSERS WITH 1' THICK FIBERGLASS WITH VAPOR BARRIER. <br />5.0 TESTING, ADJUSTING AND BALANCING <br />TEST AND BALANCE SHALL BE PROVIDED BY A COMPANY SPECIALIZING IN THE TESTING AND BALANCING OF WAC <br />SYSTEMS AS SUBCONTRACTOR TO THE WAC CONTRACTOR, GENERAL CONTRACTOR, OR OWNER. THE TEST AND BALANCE <br />CONTRACTOR SHALL BE A MEMBER OF EITHER ASSOCIATED AIR BALANCE COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL <br />BALANCING BUREAU (NEBB). <br />6.0 SUBMITTALS <br />PROVIDE 6-SETS (IN BINDER) OF MANUFACTURERS DATA, ELECTRICAL DATA, DIMENSIONAL DATA AND CLEARANCES, CONNECTION DATA, <br />COLOR SAMPLES (IF REQUIRED) AND TEST DATA FOR A/C EQUIPMENT, CONTROLS, EXHAUST FANS AND DIFFUSER/GRILLES. <br />SHOP DRAWINGS AND 0&M MANUALS MUST BE SUBMITTED AND APPROVED PRIOR TO ORDERING EQUIPMENT. ENGINEER WILL REQUIRE <br />10 WORKING DAYS TO REVIEW DRAWINGS. <br />Project No. 15017.00 1 <br />M1,60 <br />1 <br />02015 BH/PK Architects, Inc. <br />$DATE$ $TIME$ $FILEA$ <br />