Laserfiche WebLink
y <br />N <br />&TT <br />0 <br />IN <br />M O <br />00 <br />ZE <br />I. <br />EXISTING PANELBOARD SCHEDULE <br />PLAN <br />MARK <br />BRANCHES <br />MAINS <br />MINIMUM <br />BREAKER <br />AIC - SYM <br />MOUNTING <br />AND <br />REMARKS <br />NO. <br />POLE <br />AMP <br />CIRCUITS <br />SIZE <br />POLE <br />MAIN <br />VOLT <br />1AHP <br />(NORMAL) <br />12 <br />1 <br />20 <br />IN USE <br />225 <br />AMP <br />3P <br />+ <br />SN <br />+ <br />GRND <br />MLO <br />277/480 <br />35,000 AIC <br />SURFACE MOUNTED PANEL, USE SPARE BREAKERS AVAILABLE <br />IN PANELBOARD FOR NEW CIRCUITS. IF REQUIRED PROVIDE <br />20A/1P BREAKERS USING SPACES. ALSO IF EXISTING CAPACITY <br />BECOMES AVAILABLE FROM DEMOLITION WORK THE RE - USE <br />THESE CIRCUITS AFTER LOAD READINGS. <br />1 <br />1 3 <br />30 <br />IN USE <br />2 <br />3 <br />20 <br />IN USE <br />21 <br />1 <br />20 <br />SPARES & SPACES AVAILABLE <br />1 HCB <br />(CRITICAL) <br />4 <br />1 <br />20 <br />IN USE <br />225 <br />AMP <br />3P <br />+ <br />SN <br />+ <br />GRND <br />MLO <br />277/480 <br />35,000 AIC <br />SURFACE MOUNTED PANEL, USE SPARE BREAKERS AVAILABLE <br />IN PANELBOARD FOR NEW CIRCUITS. IF REQUIRED PROVIDE <br />20A/1P BREAKERS USING SPACES. ALSO IF EXISTING CAPACITY <br />BECOMES AVAILABLE FROM DEMOLITION WORK THE RE - USE <br />THESE CIRCUITS AFTER LOAD READINGS. <br />38 <br />1 <br />20 <br />SPARES & SPACES AVAILABLE <br />1 BLP <br />(NORMAL) <br />2-SECTION <br />22 <br />1 <br />20 <br />IN USE <br />225 <br />AMP <br />3P <br />+ <br />SN <br />+ <br />GRND <br />150A <br />3P <br />MAIN <br />BRKR <br />120/208 <br />10,000 AIC <br />SURFACE MOUNTED PANEL, USE SPARE BREAKERS AVAILABLE <br />IN PANELBOARD FOR NEW CIRCUITS. IF REQUIRED PROVIDE <br />20A/1P BREAKERS USING SPACES. ALSO IF EXISTING CAPACITY <br />BECOMES AVAILABLE FROM DEMOLITION WORK THE RE - USE <br />THESE CIRCUITS AFTER LOAD READINGS. <br />62 <br />1 <br />20 <br />SPARES & SPACES AVAILABLE <br />1 BLCB <br />(CRITICAL) <br />2-SECTION <br />27 <br />1 <br />20 <br />IN USE <br />225 <br />AMP <br />3P <br />+ <br />SN <br />+ <br />GRND <br />150A <br />3P <br />MAIN <br />BRKR <br />120/208 <br />10,000 AIC <br />SURFACE MOUNTED PANEL, USE SPARE BREAKERS AVAILABLE <br />IN PANELBOARD FOR NEW CIRCUITS. IF REQUIRED PROVIDE <br />20A/1P BREAKERS USING SPACES. ALSO IF EXISTING CAPACITY <br />BECOMES AVAILABLE FROM DEMOLITION WORK THE RE - USE <br />THESE CIRCUITS AFTER LOAD READINGS. <br />57 <br />1 <br />20 <br />SPARES & SPACES AVAILABLE <br />1 HLS <br />(LIFE <br />SAFETY) <br />12 <br />1 <br />20 <br />IN USE <br />225 <br />AMP <br />3P <br />+ <br />SN <br />+ <br />GRND <br />MLO <br />277/480 <br />18,000 AIC <br />SURFACE MOUNTED PANEL, USE SPARE BREAKERS AVAILABLE <br />IN PANELBOARD FOR NEW CIRCUITS. IF REQUIRED PROVIDE <br />20A/1P BREAKERS USING SPACES. ALSO IF EXISTING CAPACITY <br />BECOMES AVAILABLE FROM DEMOLITION WORK THE RE - USE <br />THESE CIRCUITS AFTER LOAD READINGS. <br />1 <br />3 <br />45 <br />XFMR T-30 IN USE <br />27 <br />1 <br />20 <br />SPARES &SPACES AVAILABLE <br />1 LLS <br />(LIFE <br />SAFETY) <br />11 <br />1 <br />20 <br />IN USE <br />100 <br />AMP <br />3P <br />+ <br />SN <br />+ <br />GRND <br />100A <br />3P <br />MAIN <br />BRKR <br />120/208 <br />10,000 AIC <br />SURFACE MOUNTED PANEL, USE SPARE BREAKERS AVAILABLE <br />IN PANELBOARD FOR NEW CIRCUITS. IF REQUIRED PROVIDE <br />20A/1P BREAKERS USING SPACES. ALSO IF EXISTING CAPACITY <br />BECOMES AVAILABLE FROM DEMOLITION WORK THE RE - USE <br />THESE CIRCUITS AFTER LOAD READINGS. <br />31 <br />1 <br />20 <br />SPARES & SPACES AVAILABLE <br />TO GENERATOR <br />ELEC. CLOSET <br />I <br />i <br />1BLP <br />C <br />T-45 <br />1BHP <br />T-45 <br />--------------- <br />1BLCB <br />�a <br />a <br />0 <br />I� <br />�1-#2 GRND. �1-#2 GRND. <br />I <br />342 & 146 4-#1 & 1-#3 <br />GRND, IN 1�"C. I GRND., IN 1Y2"C. <br />3 SETS 4-350 MCM & 142/0 GRND., IN 3-3"C. <br />0 40OA13P 80OA13P <br />v 40OA13P 800A13P <br />r, <br />120OA13P <br />MSB I I GDP <br />FROM UTILITY XFMR GEN. DISTRIBUTION (800/ <br />277/480 VOLT, 30 <br />7,412 SCA <br />65,000 AIC <br />SWBD 4000A <br />277/480 VOLT, 30 <br />56,891 SCA <br />65,000 AIC <br />ATS-CB (800A <br />480 VOLT, 30 <br />50,015 SCA <br />65,000 AIC <br />1LLS <br />M <br />1 HLS < <br />SCHEDULES OF LIGHTING EQUIPMENT & LAMPS <br />FIX. <br />TYPE <br />MANUFACTURER <br />CATALOG <br />NUMBER <br />LAMPS <br />TYPE OF FIXTURE <br />MOUNTING <br />NOTES <br />INCAND. <br />FLUOR. <br />MISC. <br />REC <br />SUR <br />SUS <br />FA <br />EXISTING <br />(37) EXISTING 2x4 LIGHTS <br />FB <br />LIGHTOLIER <br />SPS2GFSVI317-277- <br />3-F17 <br />2x2 LENS TROFFER <br />X <br />277V. <br />03 <br />T-8 <br />FC <br />LIGHTOLIER <br />11 13TCUl 102T26U <br />(2)-26WQT <br />6Y4" LOW PROFILE <br />X <br />277V. <br />DOWNLIGHT <br />XA <br />LIGHTOLIER <br />LLNURW <br />LED <br />SINGLE FACE W/ NO ARROW <br />X <br />277V. <br />XB <br />LIGHTOLIER <br />LLNURW <br />LED <br />SINGLE FACE W/ ARROW <br />X <br />277V. <br />ELEC. CLOSET #106 <br />I <br />I <br />I <br />I <br />I <br />I <br />1 <br />441 & 1 44 <br />GRND., IN 1Y2"C. <br />I <br />— — — — — — — — — — I <br />4-#3/0 & 1�2 3�t4 & 1�I 8 <br />GRND, IN 2"C. <br />GRND., IN 1%"C. <br />4-500 MCM & 142 F <br />GRND., IN 4"C. <br />I <br />I <br />ATS-LS 400A <br />480 VOLT, 3Q1 I ^ ^ ^ <br />N N 4 SCA 1 200A/3P 70A13P 125A13P <br />L L 65,000 AIC <br />E E 1 <br />1HLSDP 1HCBDP <br />I <br />GRND HOSP. <br />4-500 MCM & 142 1 <br />(�GRND.,IN4"C.— — — — — — — ----- -- <br />T-30 <br />(t1-#4 GRND. <br />3 SETS 4-350 MCM & 14% GRND., IN 3-3"C. LIFE SAFETY DISTRIBUTION <br />277/480 VOLT, 30 <br />15,963 SCA <br />65,000 AIC <br />EXISTING ELECTRICAL RISER DIAGRAM <br />NO SCALE <br />1HCBI I1AHP <br />4-#2 & 146 <br />GRND., IN 1 Y4"C. <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />NORMAL DISTRIBUTION <br />277/480 VOLT, 30 <br />41,874 SCA 1 <br />65,000 AIC <br />I L^ ^� <br />125A13P 125A13P <br />L1-- -- <br />70A13P <br />1HNDP <br />-----------------I <br />4 SETS 4-400 MCM & <br />144/0 GRND., IN 4-3"C. <br />CRITICAL DISTRIBUTION <br />277/480 VOLT, 30 <br />33,800 SCA <br />65,000 AIC <br />design <br />GRN <br />Heery International Inc. <br />4700 Millenia Boulevard, <br />Suite 550, <br />Orlando, Florida 32839 <br />407.992.6300 <br />EB 0005176 <br />Seal: <br />\01►wcI l <br />i <br />* ; No 49493 , <br />700 STATE OF 1',IR7 <br />11oNa i i\\)Z- 1 Z <br />JONATHAN R. CANDOR - PE #49493 <br />Project No. <br />12036.00 <br />E3. <br />I <br />1 02012 BH/PK Architects <br />$DATE$ $TIME$ $FILEA$ <br />