My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (128)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (128)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:32:33 PM
Creation date
2/25/2025 9:48:30 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Rodda Construction
Building Plans - Permit #
13681
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
y <br />Lm <br />RO <br />N <br />o, <br />o <br />N <br />ca <br />N <br />COMMUNICATIONS SYSTEMS: <br />OS <br />M <br />MUSIC SPEAKER <br />Q <br />STAFF PAGING SPEAKER WITH VOLUME CONTROL. <br />RP <br />Q. <br />HOSPITAL / PUBLIC PAGING SPEAKER <br />RY <br />OS <br />SPEAKER OUTLET RECESSED IN CEILING (UNLESS <br />NOTED OTHERWISE) -'S' INDICATES SURFACE <br />R <br />TYPE -'C' INDICATES SPEAKER CONCEALED ABOVE <br />CEILING -'P' INDICATES PROJ. HORN TYPE -'DF' <br />INDICATES DOUBLE FACE TYPE. <br />SPEAKER OUTLET RECESSED IN WALL (UNLESS <br />OTHERWISE NOTED) - MOUNTED +84" ABOVE FLOOR OR AS <br />NOTED -'S' INDICATES SURFACE TYPE. <br />TYPE -'P' INDICATES PROJECTION HORN <br />TYPE -'DF' INDICATES DOUBLE FACE TYPE. <br />VOLUME CONTROL - NUMERAL DESIGNATES <br />I <br />ASSOCIATED SPEAKERS. <br />O <br />MICROPHONE OUTLET - IN FLOOR BOX <br />MICROPHONE OUTLET - IN WALL <br />CLOCK OUTLET IN CEILING WITH PROGRAM <br />OR OTHER SYSTEM CLOCK AS SPECIFIED- <br />'DF' INDICATES DOUBLE FACE CLOCK <br />DIMENSION INDICATES DIAL SIZE. <br />CLOCK OUTLET IN WALL WITH PROGRAM <br />OR OTHER SYSTEM CLOCK AS SPECIFIED <br />'DF' INDICATES DOUBLE FACE CLOCK <br />DIMENSION INDICATES DIAL SIZE. <br />MOUNTED +84" ABOVE FLOOR OR AS NOTED. <br />COMBINATION CLOCK AND SPEAKER <br />�-� <br />OUTLETS IN COMMON BACK BOTH - WITH <br />CLOCK AND SPEAKER AS SPECIFIED. <br />MOUNTED +84" ABOVE FLOOR OR AS NOTED. <br />PROGRAM OR SIGNAL BELL - MOUNTED +84" ABOVE <br />FLOOR OR AS NOTED. <br />BUZZER - MOUNTED +84" ABOVE FLOOR OR AS NOTED. <br />TELEVISION CABLE SYSTEM OUTLET, <br />WITH REMOTE CONTROL STATION, IN WALL <br />AS NOTED. <br />TELEVISION ANTENNA SYSTEM OUTLET, <br />WITH REMOTE CONTROL STATION <br />MOUNTED IN CEILING. <br />TELEVISION ANTENNA SYSTEM OUTLET IN <br />WALL AT +18" ABOVE FLOOR OR AS NOTED. <br />�- <br />TELEVISION CAMERA OR VIDEO TAPE JACK. <br />CLOSED CIRCUIT TELEVISION OUTLET, <br />IN WALL AT +18" ABOVE FLOOR OR AS NOTED. <br />Q-O <br />TELEVISION ANTENNA SYSTEM IN CEILING. <br />ce <br />CLOSED CIRCUIT TELEVISION OUTLET, <br />IN CEILING <br />M FC <br />INTERCOM MASTER - DESK MOUNTED. <br />I C <br />INTERCOM MASTER - WALL MOUNTED 60" <br />M <br />ABOVE FLOOR OR AS NOTED. <br />IC <br />INTERCOM REMOTE UNIT - DESK MOUNTED. <br />IC <br />INTERCOM REMOTE UNIT - WALL MOUNTED <br />+60" ABOVE FLOOR OR AS NOTED. <br />TELEPHONE OUTLET - IN WALL +18" ABOVE <br />FLOOR OR AS NOTED. <br />TELEPHONE OUTLET - IN FLOOR BOX. <br />INFORMATION MANAGEMENT (IMO) WALL MOUNTED <br />+18" ABOVE FLOOR OR AS NOTED. <br />INFORMATION MANAGEMENT OUTLET (IMO) <br />IN FLOOR BOX. <br />INFORMATION MANAGEMENT (IMO) WALL MOUNTED <br />+18" ABOVE FLOOR OR AS NOTED. WIRE ALL <br />DEVICES WITH THIS SYMBOL. <br />PAY TELEPHONE OUTLET - IN WALL 48" ABOVE <br />FLOOR OR AS NOTED. <br />COMBINATION FLOOR BOX, W / DOUBLE DUPLEX <br />�(v)� P <br />RECEPTACLE - 20A 125V 2P. 3W. & IMO OUTLET <br />`�- <br />TO BE POURED IN PLACE. FSR'S #FL-500P <br />COMBINATION FLOOR BOX, W / DOUBLE DUPLEX <br />R <br />RECEPTACLE - 20A 125V 2P. 3W. & IMO OUTLET <br />TO BE USED IN RAISED FLOOR TILES. FSR'S #RFL-AV <br />JUNCTION BOX IN WALL 48" ABOVE FLOOR <br />Opp <br />TELEPHONE AND DATA EQUIPMENT CONNECTION <br />FOR POWER POLE. IN CEILING SPACE <br />COMMUNICATIONS SYMBOLS <br />NOTE: NOT ALL SYMBOLS SHOWN MAY BE REQUIRED FOR THIS PROJECT. <br />FIRE ALARM SYSTEMS: <br />FP FIREMAN'S PHONE <br />FCP FIRE ALARM CONTROL PANEL <br />FSA FIRE ALARM SYSTEM ANNUNCIATOR <br />FTR I FIRE ALARM TRANSPONDER / TRANSMITTER <br />ESR ELEVATOR STATUS RECALL <br />FAC FIRE ALARM COMMUNICATOR <br />HCP HALON CONTROL PANEL <br />F M 2 FM-200 PANEL <br />HVA HVAC / STAIR PRESSURIZATION CONTROL PANEL <br />❑F PULL STATION MOUNTED @ + 42" ABOVE FLOOR <br />FA SPEAKER - WALL MOUNTED @+ 80" ABOVE FLOOR <br />(1 . SPEAKER - CEILING MOUNTED <br />OS FS SPEAKER - STROBE CEILING MOUNTED <br />YY HORN WITH LIGHT AS ONE ASSEMBLY - WALL MOUNTED @ + 80" ABOVE FLOOR <br />04 <br />XX <br />YY <br />HORN WITH LIGHT AS ONE ASSEMBLY - CEILING MOUNT <br />XX <br />F�,O\ STROBE - WALL MOUNTED @ + 80" ABOVE FLOOR <br />YY <br />;o; STROBE - CEILING MOUNT <br />y XX - NO SUBSCRIPT - SET @ 1 WATT <br />1/4 - SET @ 1/4 WATT <br />1/2 - SET @ 1/2 WATT <br />2- SET @2WATT <br />YY - NO SUBSCRIPT -15 CANDELA RATED <br />30 - 30 CANDELA RATED <br />60 - 60 CANDELA RATED <br />95 - 95 CANDELA RATED <br />110 -110 CANDELA RATED <br />0 SMOKE DETECTOR (GENERIC) <br />SMOKE DETECTOR, SPECIFIC TYPES <br />ASD. AIR SAMPLER <br />BF. BELOW FLOOR <br />BR. BEAM RECEIVER <br />BT. BEAM TRANSMITTER <br />I. IONIZATION PRODUCES OF COMBUSTION DETECTOR <br />P. PHOTOELECTRIC PRODUCTS OF COMBUSTION DETECTOR <br />SMOKE DETECTOR IN DUCT <br />Z 0. OUTSIDE AIR DUCT <br />R. RETURN AIR DUCT <br />S. SUPPLY AIR DUCT <br />jO HEAT DETECTOR (GENERIC) <br />0 HEAT DETECTOR, SPECIFIC TYPES <br />R/F. COMBINATION RATE OF RISE <br />AND FIXED TEMPERATURE <br />R/C. RATE COMPENSATION <br />F. FIXED TEMPERATURE <br />R. RATE OF RISE ONLY <br />:�- LINE -TYPE DETECTOR ( HEAT -SENSITIVE CABLE) <br />T FIRE SERVICE OR EMERGENCY TELEPHONE STATION <br />TYPES OF FIRE SERVICE OR EMERGENCY TELEPHONE STATION <br />©_ A. ACCESSIBLE FIRE SERVICE OR EMERGENCY TELEPHONE STATION <br />J. JACK FOR FIRE SERVICE OR EMERGENCY TELEPHONE STATION <br />O AUTOMATIC DOOR RELEASE CONNECTION <br />OC MAGNETIC DOOR CONTACT. <br />OK CARD / KEY READER <br />C SMOKE DAMPER CONNECTION <br />© FAN SHUT -DOWN CONNECTION. <br />SPRINKLER FLOW SWITCH <br />VALVE WITH TAMPER PRESSURE SWITCH <br />P <br />VALVE WITH TAMPER SWITCH (SUPERVISORY) <br />i SPRINKLER PRESSURE SWITCH (ALARM) <br />PS AIR PRESSURE SWITCH ( ALARM ) <br />LPS LOW AIR PRESSURE SWITCH ( SUPERVISORY ) <br />DUCT SMOKE DETECTOR REMOTE TEST/RESET STATION. <br />R� REMOTE DETECTOR INDICATOR LIGHT <br />FIREMANS PHONE JACK +48" <br />F <br />CONDUIT & RACEWAYS: <br />EXPOSED CONDUIT OR SURFACE <br />RACEWAY'R' INDICATES RACEWAY <br />GENERAL NOTES: <br />CONDUIT CONCEALED IN WALL OR <br />CEILING CONSTRUCTION <br />1. <br />PREFORM WORK IN CONDORMANCE WITH THE NATIONAL ELECTRIC CODE AND ALL <br />APPLICABLE BUILDING CODES AS INTERPRETED BY THE LOCAL AUTHORITY HAVING <br />CONDUIT CONCEALED IN FLOOR <br />JURISDICTION. <br />CONSTRUCTION OR UNDERGROUND <br />2. <br />THE EXISTING CONDITIONS ARE SHOWN AS ACCURATELY AS FIELD CONDITIONS <br />MTV <br />SPECIAL SYSTEM WIRING TO CENTRAL <br />WOULD PERMIT. BIDDERS SHALL THOROUGHLY EXAMINE THE CONTRACT DOCUMENTS, <br />EQUIPMENT, PANEL, TERMINAL CABINET <br />VISIT THE SITE & VERIFY ALL EXISTING CONDITIONS. THE CONTRACTOR SHALL <br />OR NEXT DEVICE. <br />REPORT TO THE ARCHITECT/ENGINEERING FIRM, BEFORE SUBMITTING A BID, ANY <br />TD = TELEPHONE AND DATA <br />CONDITIONS WHICH MIGHT MAKE INSTALLATION OF REQUIRED EQUIPMENT A PROBLEM. <br />MT = EMPTY <br />NO CONSIDERATION OR ALLOWANCE WILL BE GRANTED FOR FAILURE TO INVESTIGATE <br />CP = MASTER CLOCK & PROGRAM SYSTEM <br />CONDITIONS OR MISUNDERSTANDINGS OF THE CONTRACTURAL REQUIREMENTS. <br />MC = MASTER CLOCK SYSTEM <br />IC = INTERCOM SYSTEM <br />3. <br />IT IS THE INTENT OF THESE DRAWINGS TO CALL FOR FINISHED WORK, TESTED & <br />TV = TELEVISION SYSTEM <br />READY FOR OPERATION. THE WORD "PROVIDE" MEANS "FURNISHED & INSTALL <br />TVC = TELEVISION REMOTE CONTROL <br />COMPLETE & READY FOR USE". <br />NC = NURSE CALL SYSTEM <br />P = PAGING SYSTEM <br />4. <br />SEAL ALL FLOOR & FIRE -RATED WALL PENETRATIONS WITH UL APPROVED <br />T = TELEPHONE SYSTEM <br />FIREPROOFING MATERIALS. <br />GF = CIRCUIT TO GROUND FAULT <br />CIRCUIT BREAKER <br />5. <br />MOUNTING HEIGHT GIVEN ON ELECTRICAL DRAWINGS ARE FOR BIDDING PURPOSES <br />EIL = EQUIPMENT INTERLOCK <br />ONLY. REFER TO ARCHITECTURAL ELEVATION DRAWINGS FOR MOUNTING HEIGHTS OF <br />MP = MUSIC / PAGING SYSTEM <br />ALL WIRING DEVICES & EQUIPMENT JUNCTION BOXES. WHERE DISCREPANCIES OCCUR <br />CPP = CENTRAL PAGE / PROGRAM SYSTEM <br />BETWEEN ELECTRICAL & ARCHITECTURAL DOCUMENTS, THE ARCHITECTURAL <br />STV = SECURITY TELEVISION SYSTEM <br />ELEVATIONS TAKE PRECEDENCE. <br />M = MUSIC SYSTEM <br />C = CAMERA <br />6. <br />FOR ACTUAL LOCATION OF RECESSED SPEAKERS AND SMOKE DETECTORS, SEE <br />DS = DOOR SECURITY <br />ARCHITECTURAL REFLECTED CEILING PLANS. <br />DIRECT BURIAL CABLE <br />7. <br />EACH "IMO" OUTLET SHALL HAVE ONE DOUBLE GANG BOX WITH SINGLE GANG <br />HOME RUN TO PANELBOARD-NUMBER OF <br />PLASTER RING AND ONE 1" CONDUIT TO NEAREST CORRIDOR CABLE TRAY SYSTEM. <br />ARROWS INDICATES NUMBER OF CIRCUITS <br />SELECTED OUTLETS MUST BE LOCATED ABOVE OR IN CASEWORK RESPECTIVELY. <br />CHECK ARCHITECTURAL ELEVATIONS, CASEWORK AND EQUIPMENT DRAWINGS. <br />EXPLOSION PROOF CONDUIT WITH <br />CONDUIT SEALS. <br />8. <br />COORDINATE THE LOCATION OF DUCT DETECTOR CONNECTIONS WITH MECHANICAL <br />DRAWINGS AND CONTRACTOR. <br />LAY IN WIREWAY DUCT, SIZE AS NOTED. <br />9. <br />COORDINATE THE LOCATION OF ALL IN -FLOOR POWER & COMBINATION BOXES <br />THAT ARE POURED IN -PLACE OR USED IN RAISED FLOORS WITH FURNITURE <br />CABLE TRAY, SIZE AS NOTED. <br />LAYOUTS & ARCHITECTURAL DETAILING OF COURTROOMS. <br />—fir <br />FEEDER DUCT -RATING AND NUMBER <br />OF CONDUCTORS AS NOTED. <br />PLUG IN DUCT -RATING AND NUMBER <br />OF CONDUCTORS AS NOTED. <br />PLUG IN STRIP TYPE RECEPTACLES OR <br />OTHER OUTLETS AS NOTED. <br />E <br />UNDER FLOOR DUCT -ELECTRICAL <br />T <br />UNDERFLOOR DUCT - TELEPHONE OR <br />OTHER LOW TENSION AS NOTED. <br />CONDUIT UP <br />CONDUIT DOWN <br />-� <br />-®-- <br />PULL BOX <br />GROUND <br />000a <br />BUS DUCT <br />POWER/COMMUNICATIONS LINEAR RACEWAY <br />MAPNET CIRCUIT <br />FLOOR DUCT <br />NOTES: <br />1. REFER TO PROJECT MANUAL AND/OR PROJECT <br />DRAWINGS FOR MOUNTING HEIGHTS. <br />2. UPPER CASE LETTERS'DD' AT DUPLEX <br />RECEPTACLE INDICATES DOUBLE DUPLEX <br />RECEPTACLE IN TWO GANG BOX. <br />3. LETTERS'WP' AT DEVICE OR EQUIPMENT <br />INDICATES NEMA 3R TYPE. <br />4. LETTERS'EX' AT DEVICE INDICATES EXISTING. <br />5. LETTERS "XP' AT DEVICE OR EQUIPMENT <br />INDICATES EXPLOSIONPROOF TYPE. <br />6. UPPER CASE LETTER 'W' AT TELEPHONE <br />OUTLET INDICATES WALL MOUNT. <br />7. PLUS (+) SIGN WITH DIMENSION AT <br />OUTLET INDICATES HEIGHT ABOVE <br />FINISHED FLOOR LINE OR HEIGHT <br />ABOVE FINISHED GRADE TO CENTER. <br />Project No. 12036.00 <br />ECOO 1 <br />02012 BH/PKArrbjM Inc. <br />$DATE$ $TIME$ $FILER$ <br />
The URL can be used to link to this page
Your browser does not support the video tag.