My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (129)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (129)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:36:20 PM
Creation date
2/25/2025 9:48:41 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Rodda Construction
Building Plans - Permit #
12953
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 u i i I I i L - <br />- I 1 L [I --- <br />TERMINAL SCHEDULE <br />( CONTRACTOR FURNISHED - CONTRACTOR INSTALLED) <br />ITEM <br />DESCRIPTION <br />FACILITY TO DETERMINE 112.5KVA, 480VAC, 3-PHASE, POWER SOURCE LOCATION FOR TEAL POWER CONDITIONER. <br />NEMA 1, 480VAC, THREE PHASE, 5-WIRE, FRONT OPERATED, CIRCUIT BREAKER ENCLOSURE WITH GROUND ACCESSORIES. <br />A <br />ENCLOSURE SHALL CONTAIN ONE 100AMP, 3-POLE, THERMAL MAGNETIC CIRCUIT BREAKER WITH SHUNT TRIP DEVICE. <br />FLUSH MOUNT IN WALL WHERE SHOWN. LOCATE TOP OF ENCLOSURE 6-0" A.F.F. <br />NOTE: EC SHALL ENSURE THAT LUGS ARE LARGE ENOUGH TO FACILITATE OVERSIZED INCOMING CABLES REQUIRED BY X-RAY <br />EQUIPMENT. REFER TO "INCOMING WIRE SIZE" NOTES. <br />B <br />4" x 2" SWITCH BOX. PROVIDE N.O./N.C. SWITCH WITH RED MUSHROOM HEAD AND AN "EMERGENCY OFF" NAME PLATE. <br />FLUSH MOUNT IN WALL WHERE SHOWN. LOCATE BOX CENTER LINE 6-0" A.F.F. EXACT NUMBER AND LOCATION TO BE <br />DETERMINED BY CUSTOMER. INSTALL ONLY IF REQUIRED BY PREVAILING CODE OR IF REQUESTED BY CUSTOMER <br />8" x 3" WIDE GROMMETED CABLE ACCESS HOLE IN BOTTOM OF WIRE TROUGH. LOCATE BOTTOM OF TROUGH 20" A.F.F. <br />D <br />CABLE ACCESS FOR THE IMAGING CABINET. REFER TO DETAIL ON SHEET E-6. <br />ENSURE THE WIRE TROUGH DIVIDERS ARE NOT DIRECTLY BEHIND CABLE ACCESS HOLE. <br />8" x 3" WIDE GROMMETED CABLE ACCESS HOLE ON TOP OF WIRE TROUGH. LOCATE TOP OF TROUGH 24" A.F.F. REFER TO <br />CDETAIL <br />ON SHEET E-6. CABLE ACCESS FOR THE FLAT PANEL MONITOR(S), MOUSE / KEYBOARD; X-RAY CONTROL CONSOLE; <br />OPTIONAL DVD BURNER. ENSURE THE WIRE TROUGH DIVIDERS ARE NOT DIRECTLY BEHIND CABLE ACCESS HOLE. <br />8" x 3" WIDE GROMMETED CABLE ACCESS HOLE IN BOTTOM OF WIRE TROUGH. LOCATE BOTTOM OF TROUGH 20" A.F.F. <br />ECABLE <br />ACCESS FOR THE X-RAY POWER SUPPLY CABINET. REFER TO DETAIL ON SHEET E-6. <br />ENSURE THE WIRE TROUGH DIVIDERS ARE NOT DIRECTLY BEHIND CABLE ACCESS HOLE. <br />12" x 12" x 4" DEEP JUNCTION BOX. SURFACE MOUNT ON WALL WHERE SHOWN. LOCATE BOTTOM OF JUNCTION BOX 2'-8" A.F.F. <br />E 1 <br />CONNECTION BOX FOR 480VAC, THREE PHASE POWER TO TEAL POWER CONDITIONER. <br />EC SHALL PROVIDE ONE 1 1/2 O SEALTITE AND ASSOCIATED CONNECTORS BETWEEN TEAL UNIT AND BOX E1. <br />OPEN END OF 5" O CHASE NIPPLE TERMINATED FLUSH WITH FINISHED FLOOR WHERE SHOWN. <br />GCABLE <br />ACCESS FOR THE FLOOR MOUNTED POSITIONER. <br />CHASE NIPPLE CONNECTED TO WIRE TROUGH LOCATED BELOW THE FINISHED FLOOR. <br />8" x 3" WIDE GROMMETED CABLE ACCESS HOLE IN BOTTOM OF WIRE TROUGH. LOCATE BOTTOM OF TROUGH 20" A.F.F. <br />JCABLE <br />ACCESS FOR THE ELECTRONICS RACK CABINET. REFER TO DETAIL ON SHEET E-6. <br />ENSURE THE WIRE TROUGH DIVIDERS ARE NOT DIRECTLY BEHIND CABLE ACCESS HOLE. <br />12" x 12" x 8" DEEP JUNCTION BOX. FLUSH MOUNT IN CEILING WHERE SHOWN. <br />mPROVIDE <br />ONE 2 1/2"0 CHASE NIPPLE / BUSHING CENTERED IN OVERSIZED REMOVABLE SPLIT COVERPLATE. <br />CABLE ACCESS FOR CEILING SUSPENDED MONITORS. REFER TO COVERPLATE DETAILS. <br />OPTIONAL DOOR ACTIVATED SWITCH. SQUARE-D CAT - CLASS 9007 TYPE AO (OR EQUAL). <br />N(TO <br />BE INSTALLED ONLY IF REQUIRED BY PREVAILING CODE OR IF REQUESTED BY CUSTOMER). <br />SWITCH SHALL BE LOCATED ON HINGE SIDE OF DOOR. <br />OPEN ENDS OF TWO 2-1/2" DIA. CHASE NIPPLES TERMINATED FLUSH WITH FINISHED FLOOR WHERE SHOWN. <br />T <br />CABLE ACCESS FOR THE PATIENT TABLE. <br />CHASE NIPPLES CONNECTED TO WIRE TROUGH LOCATED BELOW THE FINISHED FLOOR. <br />4" x 4" x 2" DEEP JUNCTION BOX FOR THE "X-RAY IN USE" WARNING SIGN. EXACT LOCATION TO BE DETERMINED BY <br />wOTHERS. <br />FLUSH MOUNT IN WALL OR CEILING. REQUIRES HOUSE POWER. <br />INSTALL. ONLY IF REQUIRED BY PREVAILING CODE OR IF REQUESTED BY CUSTOMER <br />JUNCTION BOX LOCATE ABOVE THE FINISHED CEILING WHERE SHOWN. SIZE DEPENDENT ON MODEL OF SURGICAL LIGHT <br />z <br />ORDERED. VERIFY SIZE WITH INSTALLERS. PROVIDE COVERPLATE WITH 6'4" LONG, 1/2" DIA. GREENFIELD. <br />CABLE ACCESS FOR SURGICAL LIGHT POWER. <br />MINIMUM 18" LONG COPPER GROUND BUS BAR. CONSULT WITH EQUIPMENT REPRESENTATIVE REGARDING EXACT SIZE AND <br />M G B <br />LOCATION. PROVIDE DRILLED AND TAPPED HOLES FOR GROUND WIRE ATTACHMENT. <br />REFER TO BLOCK DIAGRAMS. <br />NOTE: <br />REFERENCE TO "SEALTITE" BRAND MEANS REDUNDANT GROUND, PVC COATED, FLEXIBLE METAL CONDUIT. <br />NOTE: <br />THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR DIVIDING ALL JUNCTION BOXES AND CONNECTING TROUGHS TO <br />MEET LOCAL AND FLORIDA AHCA REQUIREMENTS. <br />COVERPLATE DETAILS <br />ALL FLUSH MOUNTED DEVICES SHALL HAVE OVERSIZED COVERPLATES. <br />REMOVABLE SPLIT COVERPLATE <br />2 1/2" 0 CHASE NIPPLE / BUSHING <br />14" <br />L 12" <br />(E1, M) <br />COVERPLATE <br />FACILITY: <br />Florida Hospital <br />Zephyrhills, FL <br />(NOT TO SCALE) <br />-WRAWN BY: <br />Dave Mosei <br />DATE: <br />01.30.2012 <br />FILE NAME: <br />FHZ122011 <br />SCALE: <br />1 /4" = 1' <br />SHEET: <br />
The URL can be used to link to this page
Your browser does not support the video tag.