My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (131)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (131)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:02:20 PM
Creation date
2/25/2025 9:49:12 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Berglund Construction Company
Building Plans - Permit #
2887
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 1 4 <br />17 <br />Ci <br />F:_ <br />0 <br />M <br />A <br />U <br />SC 2C <br />10,734 SF <br />CLEAN SUPPLY <br />'OILET <br />P� <br />LO <br />CORRIDOR <br />J� <br />ni <br />ui <br />ui IIII <br />ui <br />ui <br />III OFFIC E <br />SES STATION <br />!u <br />ni <br />ui <br />oil <br />OEEIC E <br />S\ <br />O— — — --_ <br />O /HOLDING <br />D O <br />O <br /><5> <br />NURSE STATION <br />O <br />1 <br />ni <br />I(M—) MENS LOCKER <br />III FC] <br />2 <br />SC 2G <br />RESTRICTED CORRIDOR <br />NURSE STATION <br />AREA OF WORK <br />of <br />TOT <br />ELEVATOR'LOBBY FE v <br />O <br />O FEx - <br />FE I <br />-------� <br />0 <br />O_-______ -_ ___ ___- ®I-C] <br />O <br />OFFICE MEETING/ EDU. ai�CORRIDOR11/�N) <br />'71 <br />ELEVATOR LOBBY <br />OH <br />O O O O <br />O O <br />OI------------ <br />N <br />SMOKE COMPARTMENT LIFE SAFETY PLAN - LEVEL 2 <br />1 SCALE: 1/8" = V-0" <br /><S> <br />LIFE SAFETY LEGEND <br />F E <br />FIRE EXTINGUISHER <br />F E C <br />FIRE EXTINGUISHER CABINET <br />OSMOKE <br />DETECTOR <br />EXIT LIGHT <br />EXIT LIGHT W/ DIRECTIONAL ARROW <br />© <br />FIRE ALARM CHIME <br />• <br />FIRE ALARM MANUAL PULL STATION <br />© <br />FIRE ALARM STROBE <br />CR <br />CARD READER <br />44 <br />EXIT ARROW / CLEAR WIDTH <br />ETD <br />EXIT TRAVEL DISTANCE <br />CPT <br />COMMON PATH OF TRAVEL <br />— — — — — <br />BASE SCOPE OF WORK <br />— - ®- <br />DEDUCT ALTERNATE SCOPE OF WORK <br />THE FOLLOWING REQUIREMENTS & REFERENCES NOTED ARE BASED UPON <br />a. FULLY SPRINKLED BUILDING, AND <br />b. EXISTING HEALTHCARE OCCUPANCY - 2009 NFPA 101, FLORIDA SPECIFIC EDITION <br />c. 2007 NFPA 80 <br />LIMITS OF SUITES <br />(NFPA 101 PAR 19-2.5.7) <br />ALL CORRIDOR WALLS ARE TO BE SMOKE TIGHT. <br />GASKETING OF DOORS SHOULD NOT BE NECESSARY <br />(NFPA 101 PAR A.8.4.3.4) (NFPA 101 PAR 19.3.6.3.1) <br />SMOKE RESISTANT CORRIDORS WITH PARTITIONS EXTENDED TO DECK ABOVE <br />® (NFPA <br />101 Par 19.3.6.3.1) <br />■ <br />a. 20 MINUTE RATED 1314" SOLID CORE WOOD DOOR, FRAME AND WINDOWS <br />(19.3.6.3.1) <br />® <br />b. POSITIVE LATCHING REQUIRED <br />(A19.3.6.3.5(1)) <br />® <br />® <br />c. NON RATED PROTECTIVE PLATE ON DOORS, UNLIMITED IN HEIGHT, ARE PERMITTED (19.3.6.3.12) <br />d. DOOR CLOSER NOT REQUIRED <br />(193.6.3.11) <br />® <br />e. MAX 1l8"GAP AT HINGE, IATCH&TOPON PULL SIDE OFSINGLE DOORS AND AT <br />® <br />MEETING EDGES OF PAIR OF DOORS <br />(NFPA806.3.1.7) <br />■ <br />f. Mg. 1" UNDERCUT FROM BTM OF DOOR TO FINISH FLOOR <br />(19.3.6.3.4) <br />■ <br />® <br />9. PERIMETER WALLS OF AREAS OPEN TO CORRIDOR CONSTRUCTED TO MATCH <br />® <br />CORRIDOR PARTfTDNS AND CEILING <br />(8.4.2) <br />h. FIRE OR SMOKE DAMPERS NOT REQUIRED <br />(19.3.7.4) <br />_ <br />ONE HOUR FIRE WALL ASSEMBLY (NFPA 101 Par 8.3.4.2) <br />® <br />a. 314 HOUR RATED DOOR & FRAME <br />(TABLE 8.3.4.2) <br />b. SELF CLOSING OR AUTOMATIC CLOSING REQUIRED <br />(8.3.3.3) <br />■_ <br />c. POSfTNE LATCHING REQUIRED <br />(19.3S.3.5) <br />■ <br />J. NON RATED PROTECTIVE PLATE UP TO 4T <br />(19.3.2.1.4) <br />® <br />e. MAX 15"GAP AT HINGE, LATCH B TOP ON PULL SIDE <br />(8.5.4.1& NFPA 806.3.1.7) <br />® <br />F. MAX 314"DOOR UNDERCUT <br />(NFPA804.8.4.1) <br />g. FIRE GLAZING SIZE LIMITED TO AREA TESTED <br />(NFPA 804.4.5) <br />h. FIRE DAMPERS REQUIRED <br />(8.3.5.6,1) <br />I. NO LOUVERS IN DOORS <br />(8.4.3.3) <br />TWO HOUR FIRE WALL ASSEMBLY (NFPA 101 Par 8.3.4.2) <br />• <br />a. 1112 HOUR RATED DOOR & FRAME <br />(TABLE 8.3.4.2) <br />■ <br />b. SELF CLOSING OR AUTOMATIC CLOSING REQUIRED <br />(8.3.3.3) <br />c. POSITIVE LATCHING REQUIRED <br />(19.3.6.3.5) <br />J. RATED PROTECTNE PLATE REQUIRED IF TOP OF PLATE IS GREATER <br />■ <br />THAN 48"ABOVE BOTTOM OF DOOR <br />(19.3.2.1.4) <br />e. MAXIS- GAP AT HINGE, LATCH& TOP ON PULL SIDE <br />(8.5.4.1& NFPA 806.3.1.7) <br />f. MAX 314"DOOR UNDERCUT <br />(NFPA804.8.4.1) <br />= <br />_ <br />g. FIRE GLAZING SIZE UNITED TO AREATESTED <br />(NFPA804.4.5) <br />h. 1 U2 HOUR FIRE DAMPER REQUIRED <br />(8S 5.6.1) <br />I. NO LOUVERS IN DOORS <br />(8.4.3.3) <br />ONE HOUR FIREISMOKE BARRIER WALL ASSEMBLY (NFPA 101, Par 19-3.7) <br />a. 20 MIN. RATED SOLID CORE WOOD DOOR OR STEEL DOOR & FRAME <br />(TABLE 8.3.42) <br />- <br />b. SELF CLOSING OR AUTOMATIC CLOSING REQUIRED <br />(19.3.7.8&8.5.4,4) <br />c. POSITIVE LATCHING NOT REQUIRED AT CROSS CORRIDOR DOORS <br />(19.3.7.8) <br />d. NON RATED PROTECTIVE PLATE UNLIMITED IN HEIGHT IS PERMITTED <br />(19.3.7.6.1) <br />e. MAX 118" GAP AT HINGE, LATCH & TOP ON PULL SIDE OF SINGLE DOORS <br />AND AT MEETING EDGES OF PAIR OF DOORS <br />(8.5.4.1& NFPA 806.3.1.7) <br />I.EXISTING ASTRAGALS SHALL REMAIN <br />g. MAX 314"DOOR UNDERCUT <br />(NFPA804.8.4.1) <br />h. FIRE GLAZING SIZE LIMITED TO AREA TESTED <br />(NFPA804A.5) <br />L FIREISMOKE DAMPER(S) REQUIRED <br />(8.5.5.2) <br />j. NO LOUVERS IN DOORS <br />(8.4.3.3) <br />KEY PLAN - LEVEL 2 O T <br />SCALE: N.T.S. TRUE PROJECT <br />NORTH NORTH <br />1/8" SCALE 8' 0 4' 8' 16' <br />301 E. Pine Street, Suite 350 <br />Orlando, Florida 32801 <br />407-893-5800 Fax 407-264-6624 <br />www.rsandh.com <br />FL Cart. Nos. AAC001886 * IB26000956 <br />5620 * LCC000210 * GB238 <br />PROJECT TITLE: <br />AdventHealth - ZEPHYRHILLS <br />OPERATING ROOMS 8 & 9 BUILD <br />OUT <br />r <br />� IIIII!! - a <br />PROJECT ADDRESS: <br />7050 GALL BLVD, <br />ZEPHYRHILLS, FL, 33541 <br />.�� OF Ft. <br />STY! • O <br />AR 99970 <br />sr�'RED• ARL� <br />I / way ` <br />SIGNATURE <br />DATE <br />REVISIONS <br />NO. DESCRIPTION DATE <br />2 ADDENDUM No. 1 07/12/2021 <br />1 AHCA & MISC. 1110812020 <br />DATE ISSUED: 12/11/2019 <br />REVIEWED BY: ML <br />DRAWN BY: TH <br />DESIGNED BY: MW <br />PROJECT NUMBER: <br />504-0253-000 <br />© 2019 RS&H, INC. <br />SHEET TITLE: <br />SMOKE <br />COMPARTMENT LIFE <br />SAFETY PLAN <br />SHEET ID: <br />BLDG. ID <br />Al 01 <br />PROJECT STATUS: <br />CONSTRUCTION <br />DOCUMENTS <br />Copyright © 2019. This drawing is an instrument of service and properly of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />3" SCALE <br />0 <br />3" <br />6" <br />1' <br />1 1/2" <br />SCALE <br />..m <br />0 <br />a <br />6" 1' 2' <br />Ir.L6ldNe��a.sac a.,. �oxzi.a-nu.�uv�xdW!!�{�eu J.e.osr, <br />3/8" SCALE 1 " 3' ' <br />1/4" SCALE 4' 0 2' 4' 8' <br />
The URL can be used to link to this page
Your browser does not support the video tag.