Laserfiche WebLink
VA <br />3 <br />4 <br />5 <br />01 <br />L <br />F. <br />a <br />0 <br />A <br />Cn <br />D <br />A <br />C) <br />7 8 g 10 11 12 <br />cvlOTinln QIMMAIA I V <br />j"*1%� DEMOLITION PLAN <br />SCALE: 1/4" = 1'-0" <br />N <br />EXISTING CONSTRUCTION <br />TO REMAIN <br />REMOVE EXISTING <br />CONSTRUCTION <br />TEMPORARY ICRA DUST <br />BARRIER. SEE PARTITION <br />DETAIL 5/A501. <br />BASE SCOPE OF WORK <br />DEDUCT ALTERNATE <br />/ SCOPE OF WORK <br />NOT IN SCOPE <br />F <br />NEGATIVE PRESSURE HEPA <br />H <br />FILTER MACHINE, SEE <br />L — J <br />MECHANICAL DRAWINGS <br />TEMPORARY EXIT SIGN <br />nFE FIRE EXTINGUISHER <br />1 D REMOVE PORTION OF EXISTING WALL AS REQUIRED <br />FOR DOOR AND FRAME INSTALLATION <br />REMOVE EXISTING DOOR, FRAME, AND HARDWARE <br />3D THIS DOOR SHALL SERVE AS THE MAIN <br />CONSTRUCTION ACCESS TO THE PROJECT AREA <br />DURING CONSTRUCTION. REMOVE EXISTING <br />DOOR & FRAME DURING LAST STAGE OF <br />CONSTRUCTION. SEE FLOOR PLAN FOR INFILL OF <br />OPENING. <br />CUT OPENING IN EXISTING STRUCTURAL METAL STUD <br />4D FRAMED EXTERIOR WALL W/ EIFS SYSTEM AS <br />REQUIRED FOR NEW DOOR & FRAME. SEE FLOOR PLAN <br />AND DOOR SCHEDULE SHEET A401 FOR DETAILS. <br />PREPARE EXISTING SLAB TO RECEIVE NEW FLOOR <br />5D FINISH AS SCHEDULED. <br />REMOVE EXISTING FLOOR FINISH & WALL BASE AND <br />6D PREPARE SLAB TO RECEIVE NEW FLOOR FINISH AS <br />SCHEDULED <br />DECOMMISION FIRE RATING - PARTITION TO REMAIN <br />SMOKE TIGHT. REMOVE STENCILING ABOVE <br />CEILING; SEE MECHANICAL DRAWINGS. <br />8D REMOVE EXISTING VIEW WINDOW & INFILL OPENING <br />IN EXISTING WALL. 2 <br />9D OMIT <br />0 TAPE SEAL DOOR TO PREVENT DUST ENTERING. <br />KEY PLAN - LEVEL 2 <br />SCALE: N.T.S. TRUE PROJECT <br />NORTH NORTH <br />i� <br />301 E. Pine Street, Suite 350 <br />Orlando, Florida 32801 <br />407-893-5800 Fax 407-264-6624 <br />www.rsandh.com <br />FL Cert. Nos. AAC001886 * IB26000956 <br />5620 * LCC000210 * GB238 <br />PROJECT TITLE: <br />AdventHealth - ZEPHYRHILLS <br />OPERATING ROOMS 8 & 9 BUILD <br />OUT <br />PROJECT ADDRESS: <br />7050 GALL BLVD, <br />ZEPHYRHILLS, FL, 33541 <br />AR 99970 <br />AFC•..... .,.�'�� <br />�SrFRED PRL� <br />-Mak, W <br />SIGNATURE <br />DATE <br />REVISIONS <br />NO, DESCRIPTION DATE <br />2 ADDENDUM No.1 07/12/2021 <br />1 AHCA & MISC. 1/08/2020 <br />DATE ISSUED: 12/11/2019 <br />REVIEWED BY: ML <br />DRAWN BY: TH <br />DESIGNED BY: MW <br />PROJECT NUMBER: <br />504-0253-000 <br />© 2019 RS&H, INC. <br />SHEET TITLE: <br />DEMOLITION PLAN <br />SHEET ID: <br />BLDG. ID <br />Al 02 <br />PROJECT STATUS: <br />CONSTRUCTION <br />DOCUMENTS <br />Copyright© 2019. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />FEC FIRE EXTINGUISHER CABINET <br />3" SCALE 0 3" 6" 1' 1 1/2" SCALE 0 6" 1' 2' <br />EEEMNENENNW <br />3/8" SCALE 1 " 3' ' <br />1/4" SCALE 4' 0 2' 4' 8' <br />1/8" SCALE 8' 0 4' 8' 16' <br />