My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3187 Fallstone Way
Zephyrhills
>
Building Department
>
Building Plans
>
3187 Fallstone Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:03:40 AM
Creation date
2/19/2025 2:20:51 PM
Metadata
Fields
Template:
Building Plans
Street #
3187
Location
Fallstone Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DOOR JAMB (REFER 1x4 1/2" DRYWALL <br />DOOR JAMB (REFER 1x4 <br />1/2" DRYWALL <br />r <br />DOOR JAMB REFER <br />TO PRODUCT <br />1x4 <br />1/2" DRYWALL <br />TO PRODUCT <br />P.T. <br />TO PRODUCT <br />APPROVAL FOR CONN. <br />_f— <br />APPROVAL FOR CONN. <br />APPROVAL FOR CONN. <br />1x4 <br />I" 1 X 4 <br />l.- FURRING <br />3-1/4" LONG X 3/16"0 <br />❑ <br />L FURRING <br />3/16"0 X 3" LONG <br />TAPCONS <br />FURRING <br />(2) ROWS 3/16" x 3-1/2" <br />TAPCON. INTO <br />STAGGERED @ 16° <br />TAPCON 16" O.C. & 4" <br />2Xg <br />BLOCK@ SPACING „ <br />1 <br />DETAIL <br />1x8 <br />O.C. 2-ROWS INTO <br />P.T. <br />FROM EACH END w/ MIN. <br />2" EDGE DIST. ATTACH <br />1X8 <br />PER MANUFACTURE <br />MASONRY THROUGH 1 _ 1 /211 <br />DETAIL <br />1x8 w/ (2) ROWS 8d NALS <br />�� <br />3 DETAIL <br />1x4 P.T. & 1x8 P.T. <br />STAGGERED @ 12" O.C. <br />3/16" x 3 -112" <br />1x4 P.T. <br />DOOR JAMB (REFER <br />TAPCON @ 16" <br />TO PRODUCT <br />O.C. & 4" FROM <br />DOOR JAMB (REFER <br />APPROVAL FOR CONN. <br />1x4 <br />1/2" DRYWALL <br />DOOR JAMB (REFER <br />EACH END W/ MIN. <br />TO PRODUCT <br />TO PRODUCT <br />2" EDGE DIST. <br />APPROVAL FOR CONN. <br />2x8 P.T. w/ (2) ROWS 3/16" <br />APPROVAL FOR CONN. <br />2 ROWS 3/16" x 3-1/2° <br />O <br />❑ <br />x 3-1/2" TAPCON @ 16" <br />O.C. & 4" FROM EACH <br />1x4 <br />❑ <br />TAPCON @ 16" O.C. & <br />END w/ MIN. 2" EDGE DIST. <br />FURRIN( <br />4" FROM EACH END w/ <br />2x8 P.T. <br />ATTACH SECOND PLY w/ <br />2x P.T. AS REQ'D <br />MIN. 2" EDGE DIST. <br />(2) ROWS 10dx3" <br />2x8 <br />O.. nCTA II <br />0 1 1AI1 n=A II <br />STAGGERED @ 12" O.C. <br />1_1 /d" f)FTAII <br />BUILDOUT @ OVER SIZE DOOR -WINDOW ROUGH OPENINGS <br />SCALE: N.T.S. <br />1/4" MAX <br />fi SOLID BLKG. AT TOP BTWN. <br />ARCH BLKG. & BUCK —� <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />EMBEDMENT INTO BILK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45A DIAGONAL (4) 10d NAILS INTO <br />BRACE(S) 7/16" OSB 2 x 8 BRACE/ BLKG. <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />INSTALL WDW. SCREW ANCHOR ---'PP 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />INTO ARCH BLKG. PER ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 <br />INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU —� <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL J <br />SCALE: N.T.S. SS <br />2 x 8 BUCK - CONNECT TO BLOCK <br />WITH <br />1/4" x 31/4" TAPCON (1 1/4" MIN. <br />/4" MAX EMBEDMENT INTO K.) <br />2'-0" <br />BLOCK HEADER <br />SOLID BLKG. AT TOP BTWN. ARCH <br />1 X 4 FURRING <br />BLKG. & BUCK <br />8d NAILS @ 8" O.C. AT BUCK <br />2 x 8 VERT. W/ (2)10d <br />NAILS AT EA. END <br />PROVIDE 2 x 8 DIAG. BRACE BTWN". <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />LEAVE A CUT OUT IN O.S.B. ON T <br />2 x 8 VERT. BRACE(S) <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />BUILT UP PLWD. BUCK - <br />SCRIBE (NOTCH) BACKSIDE <br />7/16" OSB ARCH PANEL <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />INSTALL WDW, SCREW <br />ANCHOR INTO ARCH BLKG. <br />BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL <br />THRU OSB INTO 2 x 8 <br />PER INSTALLATION DETAILS <br />B-B <br />ARCH DETAIL rK <br />SCALE: N.T.S.. SS <br />SECTION <br />2'-0"q 78- A -A <br />1/4" x 3 1/4" TAPCONS <br />-LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />�--- 2 x 8 45 DIAAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3)10d NAILS <br />AT EA. END <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />SECTION <br />B-B <br />8" <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK - (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />EQUAL 4' MAX. RAD. <br />PROPER INSTALLATION MAX. 8" <br />FILL SOLID <br />BOTH CELLS <br />#5 REBj <br />(TYP,) <br />STD. 90' <br />HOOK (1 <br />±5" <br />NOTCH WEB AT <br />FIRST 2 COURSI <br />CAPACITY = 805 # FOR 1 STRAP <br />= 1610 # FOR 2 STRAPS <br />1 PLY PRE-ENGINEERED TRUSS <br />SIMPSON HM9KT w/ (4)1/4"x1 112" SDS <br />SCREWS & (5)1/4" x 2 1/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 wl (16)16d <br />SINKERS AND (7)1/4"x2 1/4" TITEN = 2150 #) <br />BOND BEAM OR CAST IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4'YV WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />12 <br />JACK TRUSS PROVIDED BY SEE <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />(5) 12d NAILS SIMPSON <br />2X6 TO 2X4 H2.5A w/ (10) <br />8d NAILS <br />NOTE: <br />SHED ROOF ENDS TO BE <br />GABLE ONLY, CORNERS <br />SHALL NOT BE FRAMED AS <br />HIP. <br />DESIGNED ONLY FOR THE <br />INSTALLATION OF SHINGLE <br />AND METAL ROOF FINISH <br />I <br />GLASS BLOCK INSTALLATION NOTES <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) SET LOWER COURSE OF BLOCK, MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />ANCHOR <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />1/4" EXPANSION BOLT (2 <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />9 ga. PANEL <br />PER ANCHOR) <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />(EVERY OTHER <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) <br />EXPANSION STRIP <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />SEALANT <br />• PRESS PANEL REINFORCING INTO PLACE. <br />6" MIN. LAP SPLICE W/ <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />REINFORCING PANEL <br />SMOOTH. DO NO FURROW. <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />6" MI LAP <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE NOTE: <br />REMAIN FREE OF MORTAR. <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR 2x4 <br />#2 SYP @ 24" O.C. <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH -J <br />IF TRUSSES USED) W/ (2) #6 X 4Y;t' WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2)1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY L <br />SCALE: 3/4" = 1'-0" SS <br />#5 CONT. TOP & MID <br />11 <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />W.W.M. AT PERIMETER <br />WHERE THIS CONDITION <br />OCCURS <br />WITH MIN. 3 COVER 6'-0" <br />D <br />m <br />GRADE <br />• <br />CV D <br />Cl) ` z <br />N •D <br />• <br />O D <br />(2) #5 REBAR. (1-STORY) <br />16" MIN, (1-STORY) (3) #5 REBAR. (2-STORY) <br />20" MIN. (2-STORY) WITH MIN. 3" COVER EA. WAY <br />Of <br />SECTION AT DEEP MONO FOUNDATION <br />REV. 07.28.21 <br />SCALE: 3/4" = V-0" <br />FILLED CELL PER <br />FOUNDATION PLAN <br />UNACCEPTABLE INSTALLTION <br />♦♦♦♦ <br />DO NOT DO THIS ♦♦♦♦ <br />2"x BOT. PLATE W/ (2) 10d @ 6" O.C. <br />ATTACHED WALL SHEATHING TO <br />♦♦ #5 REBAR (TYP) ♦♦ <br />♦♦ <br />3/4" PLYWOOD DECKING GLUED <br />2X BOTTOM PLATE W/ 8d @ 4" <br />,R ♦♦ <br />AND NAILED W/ 8d COMMON @ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />O.C., 2 ROWS STAGGERED <br />♦ <br />♦♦ �� 4STD. 90° HOOK (TYP.) <br />2x BAND JOIST W/ FACE NAIL 10d <br />♦♦ ..i�♦1 " <br />@TOP 8 BTTM CHORD, AND (8) <br />YP.) ♦♦ ♦♦ <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />♦'♦ <br />♦♦♦ <br />JOIST TYPICAL <br />SIMPSON HGAM1OKTA @ 12" O.C. <br />+2e NOTCHI tv. @ FIRST COURSE <br />♦♦♦♦ <br />w/ (4) 1/41 1/2" SIDS SCREWS <br />♦ ♦ <br />♦♦♦♦♦ <br />INTO BAND JOIST & (4) 1/4"x2 3/4" <br />fHE <br />TITEN INTO K.O. BLOCK <br />S ♦♦♦♦♦ <br />FILLED CELL INSTALLATION rH <br />RETROFIT FOR MISSING <br />EMBEDDED STRAP <br />SCALE: N.T.S. <br />SS <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. <br />SEE ARCH PLAN AND <br />PRE-ENG TRUSS DESIGN <br />SEE NOTE 1 BELOW <br />2x SUB FASCIA <br />ALUM DRIP EDGE <br />BRG W�ALLTYPE -r--- j ALUM FASCIA <br />PER PLAN I I 1-3/4" TRIM PAINTED <br />L F CHANNE, I <br />SS NAIL w/ 5/16" HEAD <br />FASTENED PER I DIA. @ 24" O.C. <br />NOTE 2 BELOW I Y I CONT VENTED OR SOLID SOFFIT <br />CONT 2x4 NAILED TO 2x BLOCKING NAILED TO TOP <br />BLOCKING w/ 2-12d NAILS (**) CHORD EVERY OTHER TRUSS <br />w/ 3-12d NAILS, TYP. (**) <br />1. G.C./ BUILDER TO VERIFY/PROVIDE SOFFIT MATERIAL SPAN CAPACITIES BASED <br />ON THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING <br />LISTED IN THE DESIGN CRITERIA ON SHEET SN. <br />2. FOR SOFFIT ATTACHMENT AT WALL (PER ALPHA ALUM. INC. FL# 16544 R5 FL <br />PRODUCT APPROVAL) F CHANNEL FASTENED TO: <br />- CMU w/ T NAIL .097" DIA. @ 24" O.C. w/ 5/8" MIN. EMBEDMENT <br />- WOOD w/ (3) 16 GA. 3/4"xl/4" CROWN STAPLES @ 24" MAX. O.C. IN DIAMOND <br />PATTERN <br />SUB FASCIA w/ 16 GA. 3/4"x1/4" CROWN STAPLE @ EACH GROOVE - - <br />STRUCTURAL SOFFIT <br />SF01 SCALE: 3/4" = V-0" (**) FOR ALUMINUM SOFFITS WITH SPANS <br />REV. 09.23.2021 > V-4", INSTALL MID SPAN BLOCKING PER <br />THE SOFFIT FL PA INSTALLATION CRITERIA <br />*REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.* <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />?X OV TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />ERyq * DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />+ + CFNGTy (2)10d NAILS @ 8" O.C. <br />+ + TO TRUSS TOP CHORD <br />+ + PLYWOOD SHEATHING <br />BLOCKING AS <br />'RUSS + REQUIRED TO <br />+ SUPPORT SOFFIT <br />2X4 SYP 16, . <br />EACH TRUSS <br />CONNECTOR •� • <br />SEE LINTEL <br />SCHED. <br />11 <br />PRECAST LINTEL <br />I , If JUG' SEE ELEVATION ' <br />w FOR OVER HANG <br />(MAX. 4'-0") <br />SECTION @ ROOF EXTENSION M <br />SCALE: 3/4" = V-0" SS <br />SIMPSON HTT4 w/ (18)10d x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8" DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON "SET" <br />EPDXY MIN. 6" EMBEDMENT 8 <br />3" MIN. EDGE DISTANCE <br />RETROFIT FOR MIS <br />MSTAM STRAP <br />SCALE: 31� - r <br />CFF CI-IFFT m Awn <br />' FILL 1st4 COURSES <br />SOLID W/GROUT <br />FOR OVERHANGS BETWEEN OVER 1 112" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. • " a <br />OVERHANG4,. <br />a <br />RETROFIT WALL OVERHANG DETAIL (NTS) <br />FOR OVERHANGS BETWEEN 3/4" TO 1 112" <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. <br />1 r-0" 51 <br />-01 <br />1 <br />INISH F <br />• <br />° <br />#5 BAR <br />► 10" <br />D " <br />CENTERED W/ <br />► .:' • • . . +► <br />IN TOP <br />o <br />► <br />•' <br />KNOCKOUT / <br />N <br />:; <br />• <br />CHAIR BLOCK <br />MONO FOOTING <br />SIZE AND REINF. PER PLAN <br />•. - <br />AND SECTION DETAILS <br />CLEAN FILL <br />.► •• <br />DIRT <br />Z <br />•- • <br />STANDARD <br />4 <br />� <br />9� HOOK <br />N <br />#5 BAR IN <br />FILLED CELL, <br />-. •. <br />�• <br />. -,, , -. , <br />r r •.� r <br />. r j r •, r r •, <br />h�,. <br />�... <br />STEMWALL FOOTING <br />SIZE AND <br />MONO TO STEMWALL <br />FOOTING <br />REINF. <br />AND STEMWALL <br />SECTIONN DDETAETAILS <br />SCALE: 3/4" = V-0" <br />OTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJEC <br />ONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6' EMBEDDED INTO <br />EXISTING FOOTING <br />DRILL 3/4"4" MIN. HOLE <br />SET BAR IN EPDXY <br />SAW CUT <br />EXISTING FOOTING A SECTION <br />III1 SCALE: N.T.S. <br />RETROFIT FILLED CELL DETAIL <br />SCALE: N.T.S. <br />N <br />0 <br />N <br />r <br />•i <br />00 <br />CM <br />�` <br />3 <br />r <br />< <br />C. <br />C� <br />�r, IIII j? <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />rn <br />a <br />g M8 <br />�♦ <br />N <br />0 <br />fA <br />531^rZL <br />M :3:k <br />Q <br />.a <br />C 2 LL w <br />13 <br />CoU_ u- Q. <br />Z <br />v a <br />IIY <br />$ 9 G <br />Ch <br />LLW <br />N Z Q <br />ZN <br />O U U <br />W <br />❑ ❑ <br />CD <br />z <br />- o <br />z00 <br />I n <br />Q <br />N <br />z <br />� <br />cD e <br />.0 <br />o <br />N <br />.) <br />U � <br />c <br />Q N <br />016— <br />o <br />cmo <br />Q <br />ILL_ <br />cd Cl- <br />E- 3 <br />z n <br />r ly <br />z0 <br />M <br />Zcl <br />O E <br />D <br />N <br />as i <br />Q <br />n <br />W <br />a <br />t <br />mo <br />Z <br />xZ <br />U <br />W'p <br />CD <br />o <br />�LL <br />w <br />s <br />�4 <br />r <br />O <br />'^ <br />a <br />T <br />o120 <br />> d. <br />a� <br />rn <br />N <br />0 <br />r <br />C'V <br />Ll7 <br />CO00 <br />`- V <br />I� <br />m <br />O <br />co <br />'- <br />C <br />CN <br />N <br />Ln <br />N <br />rn <br />+-+ O <br />=3 <br />cL� <br />Q 00 <br />E <br />E <br />O <br />0 <br />Z <br />E O <br />t/) <br />N <br />a <br />E <br />U _j <br />¢ p <br />JOB <br />NO: 22-08433-08426 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SS <br />
The URL can be used to link to this page
Your browser does not support the video tag.