My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36448-36468 Camp Fire Ter
Zephyrhills
>
Building Department
>
Building Plans
>
36448-36468 Camp Fire Ter
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:38:26 AM
Creation date
2/19/2025 2:22:26 PM
Metadata
Fields
Template:
Building Plans
Street #
36448-36468
Location
Camp Fire Ter
Contractor
Lennar Homes LLC
Building Plans - Permit #
Uknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'�'u L ju___ tij�'j jjljlj''!j"1r'Pj71-9H.11 111 111 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11 In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501 � 17. 1.1 through R4501 � 17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FfF <br />DUPLEX OUTLET ABOVE COUNTER <br />I /__� <br />F3-W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />FliiiF <br />HALF -SWITCHED DUPLEX OUTLET <br />I <br />111�_-v <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />T4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />MD <br />nr� <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />PH] <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />f F\11 <br />TELEVISION (OPTIONAL) <br />Fl:q 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />(D <br />THERMOSTAT <br />IM <br />ELECTRIC METER <br />NMI <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(9D <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />JIL <br />HANSON <br />BOX <br />3" VTR <br />JIL <br />OPT. <br />LAV <br />LAV <br />J- <br />--� — I I Li W/C <br />LAV SHOWER <br />TUB/ <br />W/C SHOWER <br />STUDOR <br />VEITTDBIL SINK <br />Lrj W/ DISP. <br />L�V I W/C <br />PLUMBING RISER <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS- <br />UNIT-C 1624 (1624) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1625 S.F. <br />4875 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10875 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />'T;�-50 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33935 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9574 <br />AIR CONDITIONER WATTS AT 100% <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 5200 <br />TOTAL: 31878 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />'v <br />�ETER MA N <br />1 0 �200 A P /—Serial Cable <br />NEMA <br />3R <br />Power Co. Feed 11 L #4 Solid COPPER Ground <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />C.O. <br />DB & GFI TO <br />BE ALIGNED <br />VERTICALLY <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT > <br />ROUGH -IN <br />FOR OPT. < <br />FAN/LIGHT WP <br />GFI <br />I -Tft <br />----- ff --- I <br />I <br />DINING <br />KI TCHEN <br />F — — — <br />r� r7l <br />TD-' Q <br />GFI <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br />t, >ROU <br />GH-IN\ <br />FOR OPT - <br />FAN/LIGHT <br />\o' '> <br />ME <br />NTRY <br />IGHT AS (0 <br />ER SPECS <br />a <br />LL <br />L_ <br />W <br />U- <br />0 0 <br />-4--Co ___ <br />,qF-L <br />MI "M <br />E <br />I <br />.1 UPSTAIRS F <br />AARON <br />a% <br />M4" <br />N' <br />LW. H <br />.F. <br />0 <br />IGARAGE <br />GARAGE <br />LIGHT AS <br />\�ER SPECS <br />GARAGE <br />\_6DOOR <br />GFI <br />r— — — — — — — — — — — — — — — — -- <br />_j <br />Z LU <br />10 Z <br />IP= < <br />I< <br />10 <br />0 < <br />I j 0 <br />Iy= <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL - UNIT-C 1624. <br />SCALE: X"=V-0" <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. 1, <br />2ND ELECTRICAL - UNIT-C 1624 <br />SCALE. Y4"=1'-O" <br />C' <br />L&� 0- <br />3: <br />5- <br />C14 <br />To the best of the Engineers knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />W <br />s, <br />C �4 CC <br />C <br />0 <br />a) 00 <br />Z — W *h - <br />u7 <br />r'_' 'Z ZR if L� <br />C14 0 o_ LLI <br />_j i, <br />LL 0 <br />LL. Z <br />0 <br />2 0, 5 :D <br />M 0 0 <br />> 0 <br />Lu <br />W <br />Co 04 Co < <br />0 <br />W <br />Z <br />LL <br />(1) <br />00 0 <br />0 <br />u) <br />CN U U) <br />< <br />F) <br />2 �Q <br />CD2_1 <br />iz- <br />V) <br />M <br />.12 <br />41 <br />1 0 <br />DL') <br />C. <br />V) <br />LLJ <br />Moak <br />E <br />8 <br />LL_ <br />0 <br />z 0 <br />F— M <br />CL <br />E <br />0 <br />CO <br />t <br />C: <br />Z <br />15 <br />W <br />nj <br /><� <br />C <br />.0 <br />> 00 <br />U <br />co <br />M <br />C14 <br />0 <br />C%4 <br />C-� <br />M <br />co <br />ILL <br />0-4 <br />LO <br />=3 <br />C*4 <br />Cr <br />E <br />60 <br />U) <br />co <br />00 <br />0 <br />U-) <br />C? c) <br />U—) <br />00 04 <br />(0 0 <br />C=) <br />Cn <br />< <br />04 <br />U-) <br />,6 <br />C-14 <br />I W <br />E <br />41 <br />C <br />CY) <br />LO <br />0 <br />cc <br />Z <br />:3 <br />E <br />C <br />E <br />0 0 <br />0 _j <br />'a M <br />< 0 1 <br />_j <br />)OB <br />NO: 23-05747-05752 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1 1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.