My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36507 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36507 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:48:43 AM
Creation date
2/19/2025 2:26:58 PM
Metadata
Fields
Template:
Building Plans
Street #
36507
Location
Well Hill Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
6543
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(2) SIMPSON MSTAM36 STRAPS w/ (7) 10d <br />NAILS & (4) 1/4" x 2 1/4" TITENS CENTEREC <br />ON FLOOR SYSTEM TO MASONRY WALL <br />BELOW. IF WOOD WALL IS BELOW USE (2) <br />SIMPSON MSTA36 STRAPS w/ (26) 10d <br />NAILS (G.C. TO INSURE SOLID BLOCKING <br />IS INSTALLED). <br />EXT. SHEATHING <br />FLUSH W/ TOP <br />OF MASONRY & 8d <br />NAILS T/B FLANGE <br />DS--\, <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />SEE SS FOR RETROFIT <br />CONNECTION IF MSTAM36 <br />SECTION CORNER CAN NOT BE INSTALLED <br />FRAMING ATTACHMENT 1 <br />N.T.S. <br />G.C. VERIFY INTERIOR <br />1/2" GYP. BOARD OR <br />EXTERIOR STRUCTURAL <br />SHEATHING (MIN. 7/16") <br />VERIFY W/ PLAN <br />SEE Q/S4 FOR SIMPSON SP4 w/ (6) 10d x 1 1/2" (USE SP6 FOR <br />JAMB STUD <br />O SIMPSON SP2 w/ (12) 10d NAILS <br />2x6 WALL, USE SP8 FOR 2x8 WALL)@ 24" O.C. <br />REQ'D TYP <br />O SIMPSON LSTA24 w/(18) 10d NAILS <br />T P. <br />2 - 2 x 4 SPF <br />@)SIMPSON CS16 w/ MIN. 12" END <br />q <br />TOP PLATES <br />LENGTH ON STUDS W/ (11) 10d <br />NAILS TO STUDS ABOVE & (11) 10d <br />NAILS TO STUDS BELOW. <br />2 x 4 #2 SPF STUDS <br />C <br />AT 16" O.C. U.N.O. <br />OD SIMPSON SP1 w/ (10) 10d NAILS <br />(2) 2x HEADER <br />G <br />SEE PLAN <br />�E 5/8" A.B. @ 24" O.C. AND 6" FROM <br />EACH END W/ 7" EMBEDMENT. IF <br />AT STEP DOWN LOCATION, MIN 7" <br />2 x SPF <br />EMBEDMENT PAST STEP. <br />BASE PLATE <br />PRE-ENGINEERED O SIMPSON SP4 w/ (6) 10d x 1 1/2" (USE <br />C <br />B H B <br />C <br />FLOOR SYSTEM <br />SP6 FOR 2x6 WALL, USE SP8 FOR 2x8 <br />EWALL OR BEAM WALL) AT EACH STUD AT HEADER / <br />JAMB CONDITION OR IF BUILT-UP <br />(2) - 2 x 4 SPF <br />STUDS ARE WIN WALL SYSTEM A.B. TO <br />TOP PLATES <br />BE SPACED W/IN 6" FROM OPENINGS <br />AND MULTIPLE STUD PACKS <br />LEJ <br />2 x 4 #2 SPF STUDS <br />B <br />O INTERIOR HEADER <br />AT 16" O.C. U.N.O. <br />(2) 2x HEADER <br />G <br />(1) 2x SILL PLATE W/ (2) 12dTOENAILS. <br />SEE PLAN <br />EXTERIOR HEADERS <br />E <br />F <br />TYP <br />F <br />F <br />(1) 2x SILL PLATE W/ (2) 12d TOENAILS. <br />2 x 4 P.T. <br />OPENING LARGER THAN 4 ft (2) 2x SILL PLATE <br />D <br />BASE PLATE <br />W/ SIMPSON LS30 w/ (6) 10d x 1 1/2" EACH SIDE <br />6" <br />SEE FOUND. PLAN FOR FTG. REQ. <br />O STUDS UNDER 2nd FLOOR HEADER ARE <br />NOT REQ'D TO HAVE CONNECTIONS. <br />ATTACH STUDS w/ (3) 12d TOENAILS T&B <br />2 STORY I NT. BEARING WALL <br />PROVIDE EXTERIOR SHEATHING <br />AND EXTERIOR <br />r5r5 <br />ATTACHED PER NAILING SCHEDULE <br />FOR EXTERIOR 2 STORY WALLS ONLY. <br />SHEATHING CAN STOP ONCE UNDER <br />SCALE: N.T.S. <br />LOWER ROOF. <br />SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE <br />FOLLOWED IF DOWN SET OR BOX HEADER IS USED <br />OTHERWISE DETAIL CAN BE IGNORED <br />SIMPSON LSTA30 w/ (22) 10d <br />SIMPSON SP4 w/ (6) 10d x 1 1/2" (USE SP6 FOR <br />NAILS BENT OVER TOP PLATE <br />2x6 WALL, USE SP8 FOR 2x8 WALL) @ 24" O.C. <br />THEN DOWN THE FACE OF <br />HEADER/ STUDS <br />(2) 2X SPF TOP PLATE <br />2x CRIPPLES @ 16" O.C. <br />(2) 2x HEADER SEE PLAN <br />W/ (2) 12d TOENAILS T/B <br />INTERIOR HEADER <br />(1) 2x SILL PLATE W/ (2) 12dTOENAILS. <br />(2) 10d TOENAILS AT EACH <br />EXTERIOR HEADERS <br />END OF SILL OPENING <br />(MAX.X. <br />(1) 2x SILL PLATE W/ (2) 12d TOENAILS. OPENING <br />WIDTH 4 FEET). OPENING <br />LARGER THAN 4 ft (2) 2x SILL PLATE W/ SIMPSON <br />IS GREATER THAN 4 FEET <br />LS30 w/ (6) 10d x 1 1/2" EACH SIDE <br />BUT NOT EXCEEDING 6 FEET, <br />A SIMPSON LS30 w/ (6) 10d x 1 <br />MIN (3) 2x #2 SPF STUDS @ END <br />1/2" IS TO BE INSTALLED AT <br />OF HEADER SEE Q/S4 FOR <br />EACH END <br />REQ'D JAMB INFO <br />2x CRIPPLE AT EACH <br />SIMPSON LSTA30 w/ (22) 10d NAILS <br />END OF OPENING <br />CENTERED <br />NAILED TO STUD PACK j <br />FLOOR DECK <br />W/ 10d NAILS @ 8"o.c. <br />' <br />FLOOR TRUSS/ I -JOIST SEE PLAN <br />SEE PLAN FOR BEAM <br />SIZE & CONNECTIONS <br />HEADER <br />CONN. <br />@ 2nd FLOOR <br />W/ HIGH <br />BM <br />9 <br />SCALE: N.T.S. <br />(2)- 12d <br />TOENAILS 2x4 <br />TO TRUSS TOP <br />GABLE END FLOOR <br />TRUSS SEE R/S6 FOR <br />CONNECTION INFO TO <br />MASONRY WALL <br />G) BELOW AND ALT. <br />BLOCKING INFO O <br />1. APPLY SUB <br />FLOOR <br />ADHESIVE TO <br />2x4 CONTACT <br />11�r� I SURFACE <br />O 2x4 #2 BLOCKING <br />NOTE: VERIFY WITH FLOOR <br />B 2x4 SIDE BRACE <br />FRAMING PLAN FOR I -JOIST <br />AT 48" O.C. <br />OR FLOOR TRUSS FOR <br />BETWEEN JOISTS <br />CORRECT BLOCKING <br />w/ (3) 12d EA. END <br />REQUIREMENTS <br />TO HORIZ. <br />BLOCKING <br />1-1/8" RIM BOARD <br />JOIST SEE PLAN <br />8d NAILS @ 3" O.C. <br />WALL SHEATHING <br />(2) 12d TOE NAILS TOP <br />TO RIM BOARD <br />& BOTT. CHORD <br />AJS BLOCKING PANEL @ 24" <br />O.C. (MAX) AND @ EACH <br />GABLE END RIM JOIST <br />END OF WALL UNDER <br />SEE R/S6 FOR <br />CORNERS <br />CONNECTION INFO TO <br />(2) - 10d TOE NAILS <br />MASONRY WALL <br />EACH SIDE <br />BLOCKING <br />DETAIL 2 <br />SCALE: N.T.S. <br />SEE SS FOR RETROFIT SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE <br />CONNECTION IF MSTAM36 FOLLOWED IF DOWN SET OR BOX HEADER IS USED <br />CAN NOT BE INSTALLED OTHERWISE DETAIL CAN BE IGNORED <br />SIMPSON SP4 w/ (6) 10d x 1 1/2" (USE SP6 FOR <br />(1) SIMPSON LSTA30 w/ (22) 10 <br />2x6 WALL, USE SP8 FOR 2x8 WALL) @ 24" O.C. <br />NAILS BENT OVER TOP PLATE <br />(2) - 2X SPF TOP PLATE <br />THEN DOWN THE FACE OF <br />HEADER/ STUDS <br />(2) 2x HEADER SEE PLAN <br />INTERIOR HEADER <br />(1) 2x SILL PLATE W/ (2) 12dTOENAILS. <br />MIN 3 2x #2 SPF STUDS <br />O @ <br />EXTERIOR HEADERS <br />END OF HEADER SEE Q/S4 FOR <br />(1) 2x SILL PLATE W/ (2) 12d TOENAILS. <br />REQ'D JAMB INFO <br />OPENING LARGER THAN 4 ft (2) 2x <br />SILL PLATE w/ SIMPSON LS30 w/ (6) <br />2x CRIPPLES @ 16" O.C. <br />10d x 1 1/2" EACH SIDE <br />W/ (2) 12d TOENAILS T/B <br />(2) 10d TOENAILS AT EACH END OF <br />1, <br />SILL (MAX. OPENING WIDTH 4 FEET). <br />IF OPENING IS GREATER THAN 4, <br />2X CRIPPLE AT EACH END OF <br />FEET BUT NOT EXCEEDING 6 FEET, <br />OPENING NAILED TO STUD <br />A SIMPSON LS30 w/ (6) 10d x 1 1/2" IS <br />PACK W/ 10d NAILS @ 8"O.C. <br />TO BE INSTALLED AT EACH END. <br />PLYWOOD ATTACHED PER <br />TYPICAL BLOCK WALL � <br />NAILING SCHEDULE <br />FLOOR TRUSS/ I -JOIST SEE PLAN <br />SIMPSON MSTAM36 W/ (7) <br />TIE BEAM <br />10d NAILS & (4) 1/4"x2 1/4" <br />TAPCONS <br />PROVIDE BLOCKING <br />BELOW JAMBS <br />HEADER CONN. @ 2nd FLOOR <br />SYSTEM 42 SCALE: N.T.S. <br />SEE SS FOR RETROFIT <br />SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE <br />CONNECTION IF MSTAM36 <br />FOLLOWED IF DOWN SET OR BOX HEADER IS USED <br />CAN NOT BE INSTALLED <br />OTHERWISE DETAIL CAN BE IGNORED <br />(2) SIMPSON LSTA30 w/ (22) <br />SIMPSON SP4 w/ (6) 10d x 1 1/2" (USE SP6 FOR <br />10d NAILS BENT OVER TOP <br />2x6 WALL, USE SP8 FOR 2x8 WALL) @ 24" O.C. <br />PLATE THEN DOWN THE <br />(2) 2x HEADER SEE PLAN <br />FACE OF HEADER/STUDS <br />2x CRIPPLES @ 16" O.C. <br />W/ (2) 12d TOENAILS T/B <br />INTERIOR HEADER <br />MIN (3) 2x #2 SPF STUDS <br />(1) 2x SILL PLATE W/ (2) 12dTOENAILS. <br />@ END OF HEADER. SEE <br />EXTERIOR HEADERS <br />Q/S4 FOR REQ'D JAMB <br />(1) 2x SILL PLATE W/ (2) 12d TOENAILS. <br />INFO. <br />OPENING LARGER THAN 4 ft (2) 2x <br />SILL PLATE w/ SIMPSON LS30 w/ (6) <br />2x CRIPPLE AT EACH END OF <br />10d x 1 1/2" EACH SIDE <br />OPENING NAILED TO STUD <br />PACK W/ 10d NAILS <br />; (2) 10d TOENAILS AT EACH END OF <br />SILL (MAX. OPENING WIDTH 4 FEET). <br />TYPICAL BLOCK WALL <br />IF OPENING IS GREATER THAN 4, <br />FEET BUT NOT EXCEEDING 6 FEET, <br />A SIMPSON LS30 w/ (6) 10d x 1 1/2" IS <br />SIMPSON (2) MSTAM36 w/ (7) <br />TO BE INSTALLED AT EACH END. <br />10d NAILS & (4) 1 /4"x2 1/4" <br />TAPCONS <br />.� <br />FLOOR DECK <br />PROVIDE BLOCKING <br />FLOOR TRUSS/ I -JOIST SEE PLAN <br />BELOW JAMBS TIE <br />BEAM <br />2X CONT. RIBBON <br />HEADER CONN. @ 2nd <br />FLOOR [DOUBLE STRAP] 1 <br />SYSTEM 42 SCALE: N.T.S. <br />SEE SS FOR RETROFIT <br />CONNECTION IF MSTAM36 <br />CAN NOT BE INSTALLED <br />(3) 2x # SPF <br />STUDS w/ 10d @ <br />8" O.C. EACH SIC <br />U.N.O. ON PLAN <br />2X CONT. RIBBON - <br />TYPICAL BLOCK <br />WALL -- <br />(2) SIMPSON MSTAM36 w/ <br />(7) 10d NAILS & (4) 1/4"x2 <br />1/4" TITENS <br />GIRDER/COL. CONN. <br />OR 2 PLY GIRDER <br />RUSS. SEE PLAN FOR <br />ONNECTION. <br />�EE PLAN FOR CONN. <br />) - 2x SPF TOP PLATE <br />FLOOR DECK <br />FLOOR TRUSS/ <br />I -JOIST SEE PLAN <br />TIE BEAM <br />PROVIDE BLOCKING <br />BELOW JAMBS <br />2nd FLOOR <br />SCALE: N.T.S. <br />EE PLAN FOR CONN. <br />SEE PLAN FOR <br />COL. SIZE <br />NAILING AREA (TYP.) <br />i <br />(2) SIMPSON MST37 <br />STRAPS w/ (42) 16d NAILS <br />FLOOR SYSTEM OR <br />2-STY. FRAMING <br />BAND JOIST & BLKG. <br />OR LVL GIRDER <br />(BLOCK SOLID) <br />SEE PLAN FOR <br />COL. SIZE <br />SIMPSON HTT4 w/ (18) <br />16d NAILS & 5/8" <br />ANCHOR BOLT w/ <br />MIN. 6" EMBEDMENT <br />-- SEE FOUNDATION PLAN <br />FOR FTG. REQ. <br />2 STORY COL. aC� GIRDER r7 <br />SCALE: N.T.S. <br />2x4 STUDS <br />PER PLAN <br />DOUBLE 2x4 <br />TOP PLATE <br />2 WS 10d @ <br />3" O/ <br />02 <br />q���8 M roA <br />�N <br />PROVIDE 2x4 ON -- <br />TOP OF 2x8 TO <br />BLOCK OUT TOP <br />PLATE ATTACH <br />W/ (2) 10d NAILS <br />@ 3" O.C. 2x4 BEYOND <br />AGAINST 2x8 <br />STUDS <br />2x8 STUDS <br />PER PLAN <br />NOTE: <br />PLATE LENGTHS MUST BE <br />AT LEAST 4'-0" LONG. TYPICAL <br />TOP PLATE SPLICE DETAIL <br />SCALE: N.T.S. <br />0 <br />TOP SPLICE <br />DOUBLE <br />2x82x8 TOP <br />PLATE <br />2x4 W/ 2 ROWS <br />OF 10d NAILS <br />@3"O.C. <br />(1) SIMPSON LSTA30 w/ (22) <br />10d NAILS BENT OVER TOP <br />SIMPSON SP4 w/ (6) 10d x 1 1/2" <br />PLATE THEN DOWN THE <br />(USE SP6 FOR 2x6 WALL, USE SP8 <br />FACE OF HEADER/STUDS <br />FOR 2x8 WALL) <br />@ 24" O.C. <br />2x CRIPPLES @ 16" O.C. <br />(2) 2x SPF TOP PLATE <br />W/ (2) 12d TOENAILS T/B <br />(2) 2x HEADER SEE PLAN <br />(2) 10d TOENAILS AT EA. <br />INTERIOR HEADER <br />END OF SILL. MAX. <br />(1) 2x SILL PLATE W/ (2) 12d TOENAILS. <br />OPENING WIDTH 4 FEET. <br />EXTERIOR HEADERS <br />IF OPENING IS GREATER <br />(1) 2x SILL PLATE W/ (2) 12d TOENAILS. <br />THAN 4 FEET BUT NOT <br />OPENING LARGER THAN 4 ft (2) 2x <br />EXCEEDING 6 FEET. <br />SILL PLATE w/ SIMPSON LS30 w/ (6) <br />A SIMPSON LS30 w/ (6) 10d <br />10d x 1 1/2" CLIP EACH SIDE <br />x 1 1/2" CLIP IS TO BE <br />INSTALLED AT EA. END <br />MIN (3) 2x #2 SPF STUDS @ END OF <br />HEADER SEE Q/S4 FOR REQ'D JAMB <br />INFO <br />2x CRIPPLE AT EA. <br />END OF OPENING <br />SIMPSON LSTA30 w/ (11) 10d <br />NAILED TO STUD <br />TO STUDS ABOVE PLATE <br />PACK w/10d NAILS <br />@ 8"o.c. <br />FLOOR DECK <br />FLOOR TRUSS/ I -JOIST SEE PLAN <br />SIMPSON LSTA30 FROM <br />WINDOW JAMB TO <br />FLOOR TRUSS/ SOLID <br />BLOCKING BELOW. SEE 8/D-2 <br />FOR ALT. CONDITION. DETAIL TO BE <br />FOLLOWED IF DOWN SET OR BOX HEADER IS USED <br />OTHERWISE DETAIL CAN BE IGNORED <br />HEADER CONN. <br />@ 2nd FLOOR 4 <br />SCALE: N.T.S. <br />2x6 / 2x8 CRIPPLES @ 16" O.C. <br />NOTCHED AT HEADER LOCATION <br />SEE INFO BELOW ON CONNECTIO1 <br />OF CRIPPLES IF LONGER THAN 8" <br />TALL. (CONTRACTOR MAY USE RT <br />CLIPS) NAIL BACK LEG OF CIPPLE <br />HEADER w/ (2) 12 TOENAILS <br />HEADER FLUSH TO OUT; <br />i <br />1 I <br />DOUBLE 2x6 OR 2x8 TOP <br />PLATE SEE PLAN <br />12d NAILS AT 6" <br />O.C. TYP T & B \ <br />(2) 2 x #2 \ <br />SYP U.N.O. <br />\ I <br />2 x CONT, T & B <br />(2) 2x8 OR (2) 2x6 TOP <br />PLATE SEE PLAN <br />(2) 2x HEADER TO SIT <br />FLUSH w/ THE OUTSIDE <br />SEE PLAN FOR SIZE <br />2x6 / 2x8 WALL BEYOND SEE <br />FLOOR PLAN FOR HEADER <br />CONNECTION <br />SEE STANDARD HEADER <br />CONNECTION DETAILS FOR <br />MORE INFORMATION <br />SIMPSON SP6 w/ (6) 10d x <br />1 1/2" (USE SP8 FOR 2x8 <br />WALL) @ 24" Q.C. <br />I <br />BOX HEADER <br />(2) SIMPSON LSTJ2 w/ (10) 10d (2) 2x TOP PLATE <br />NAILS WRAPPED UP AND 2x CRIPPLES @ 16" O.C. w/ <br />OVER TOP PLATE SIMPSON SP2 w/ (12) 10d NAILS AT <br />TOP AND SIMPSON SP1 w/ (10) 10d <br />— NAILS AT BASE <br />*PROVIDE (2) CRIPPLES BELOW <br />TO ANY GIRDER TRUSS IN THIS <br />2x CRIPPLES TO SITUATION. CONNECT G.T. TO <br />MATCH JACK STUDS w/ (2) SIMPSON HTS20 w/ <br />(24) 10d x 1 1/2" NAILS AT TOP AND <br />STUDS BELOW BOTTOM TO HEADER <br />(IF CRIPPLES ARE LESS THAN 8" <br />LONG NO STRAPS ARE REQ'D) <br />ADDITIONAL STRAPS <br />SEE STANDARD HEADER REQUIRED AT TOP PLATE <br />CONNECTION DETAILS FOR TO STUDS TO MATCH <br />MORE INFORMATION HEADER STRAPS <br />(2) SIMPSON LSTA24 w/ (18) 10d NAIL (2) 2x HEADER SEE PLAN <br />MIN (3) 2x #2 SPF STUDS @ END OF HEADER <br />SEE Q/S4 FOR REQ'D JAMB INFO <br />SIMPSON LS30 w/ (6) 10d x 1 1/2" NAILS AT EACH END TYP. <br />*FOR OPENINGS LESS THAN 4'-0" WIDE, SILL MAY BE <br />ATTACHED w/ (2) 16d TOENAILS AT EACH END <br />(2) 2x SILL PLATE <br />2x STUDS @ 16" O.C. <br />ALT. HEADER ANCHOR r8 <br />SCALE: N.T.S. <br />p <br />0 <br />a <br />LU <br />_ M V M <br />®amX <br />N = LL <br />— Cc <br />Q w � <br />3 = „ <br />CU � :!E a� <br />'5'. E <br />d -f <br />�d�Ja <br />�. <br />d <br />N C <br />4n a <br />E <br />o <br />IW 1, <br />01 <br />N <br />>>d!lilllltti',��� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W �E <br />Qo a 8 <br />O N p <br />0 co <br />J <br />N �Mv <br />Q <br />LL W <br />NLL L_ <br />J w a <br />z <br />L (4 �O <br />L" <br />'f6 CV c0 O O <br />W <br />LLN <br />O U �d <br />W � rn <br />0 M <br />z N M <br />og <br />z o ad <br />� N <br />Q <br />tl N <br />N <br />u- <br />o <br />_� <br />LU � <br />O w o <br />N ry N <br />�NW <br />A <br />ca <br />LLJ <br />) y <br />Q 0 <br />O <br />N <br />(� <br />w <br />M <br />M <br />N QZ <br />Z <br />Q <br />LL <br />CET <br />E Eo <br />E CJ <br />zo <br />o g <br />wz <br />>m <br /><� <br />z© <br />oa <br />Uo <br />p E <br />O <br />Z <br />Ww <br />ra <br />0 <br />m <br />z <br />m� <br />U <br />�mQw <br />O1 <br />q <br />Q� <br />Zg�z <br />m <br />oco <br />wLL <br /><p <br />o <br />az <br />�w <br />IF, <br />o <br />w� <br />ol¢ <br />ao <br />0 <br />3 <br />c0 <br />0 <br />_ <br />J <br />� <br />I6 <br />O <br />N <br />m <br />M <br />0 <br />LO (� <br />r <br />LO <br />^ <br />Cr T_ > <br />r <br />1 <br />M <br />L <br />O <br />r <br />N <br />Q U') <br />r <br />E <br />M <br />L <br />6 <br />Z <br />Z <br />N <br />E <br />C <br />_@ <br />a- <br />o <br />U -1 Q <br />JOB <br />NO: 23-06121 <br />SCALE : AS NOTED <br />SHEET NO. <br />D2 <br />I r itllll 11111 T— <br />-J <br />