OUTLINE SPECIFICATIONS
<br />3 CONCRETE - - - -
<br />5 METALS
<br />1
<br />6 WOOD (CONTR,TUED) --- -
<br />7 THERMAL AND MOISTURE PROTECTION (CONTINUED)
<br />7 THERMAL AND MOISTURE PROTECTION (CONTINUED)
<br />3.01 CAST -IN -PLACE CONCRETE:
<br />5.01 METAL FABRICATIONS
<br />6.04 ARCIRTECTURAL WOODWORK:
<br />7.03 EXTERIOR INSULATION AND FINISH SYSTEM (EIFS)
<br />7.07 METAL WALL PANELS
<br />GENERAL: SEE STRUCTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS THAT
<br />GENERAL: SEE STRUCTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS THAT
<br />GENERAL: COMPLY WITH AWI QUALITY STANDARDS. COMPLY WITH CARB
<br />GENERAL: DO NOT INSTALL WHEN AIR OR WALL TEMPERATURES WILL BE BELOW
<br />GENERAL: PROVIDE STRUCTURAL METAL WALL PANEL SYSTEMS MEETING
<br />APPLY TO THIS SECTION.
<br />APPLY TO THIS SECTION.
<br />REQUIREMENTS FOR FORMALDEHYDE EMISSION LEVELS. SUBMIT SHOP DRAWINGS
<br />40 DEGREES F OR ABOVE I 00 DEGREES F WITHIN 24 HOURS OF APPLICATION, DO NOT
<br />INDICATED REQUIREMENTS AS DETERMINED BY QUALIFIED TESTING AGENCY:
<br />SUBMITTALS: SUBM[IT PRODUCT DATA FOR REVIEW.
<br />SUBM[ITTALS: SUMBIT SHOP DRAWINGS FOR INDICATED PRODUCTS SEALED BY
<br />OF ARCHITECTURAL WOODWORK FOR REVIEW. PROTECT WOOD PRODUCTS FROM
<br />INSTALL DURING INCLEMENT WEATHER UNLESS PROTECTION IS PROVIDED.
<br />STRUCTURAL PERFORMANCE: WITHSTAND DESIGN WIND LOADS INDICATED,
<br />TOLERANCES: PLACE CONCRETE AT INDICATED LOCATIONS AND ELEVATIONS,
<br />A PROFESSIONAL ENGINEER REGISTERED TO PRACTICE IN THE JURISDICTION
<br />EXPOSURE TO WEATHER AND CONTACT WITH WET SURFACES. DO NOT DELIVER
<br />WOODWORK FOR INTERIOR USE UNTIL TEMPERATURE AND HUMIDITY CONDITIONS
<br />SUBMITTALS: SUBM[IT PRODUCT DATA AND TEST REPORTS INDICATING
<br />WITH MAXIMUNI DEFLECTION OF 1/120 OF THE SPAN.
<br />TRUE TO LINE, PLUMB, AND LEVEL (1/8" IN 10', 1/4" IN TOTAL).
<br />WHERE THE PROJECT IS LOCATED, SHOWING COMPLIANCE WITH THE
<br />INDICATED STRUCTURAL REQUIREMENTS WITHOUT EXCEEDING ALLOWABLE
<br />HAVE BEEN STABILIZED AT FINAL OCCUPANCY LEVELS, AND CONDITION MINIMUM
<br />CONTLIANCE WITH REQUIREMENTS.
<br />THERMAL MOVEMENT: ALLOW FOR THERMAL MOVEMENT AND DEFLECTION
<br />DRAINAGE FELL: WASHED CRUSHED STONE, ASTM C33 NO. 57. PLACE AND CONTACT
<br />WORKING STRESS OF MATERIALS, INCLUDING ANCHORS AND CONNECTIONS.
<br />3 DAYS IN STABILIZED SPACE BEFORE INSTALLATION.
<br />PERFORMANCE REQUIREMENTS: PROVIDE EXTERIOR INSULATION AND FINISH
<br />FROM AMBIENT AND INTERNAL TEMPERATURE VARIATIONS.
<br />DRAINAGE FILL MATERIAL TO REQUIRED ELEVATIONS, WITH A TOLERANCE OF 1/2"
<br />PLASTIC LAMINATE CABINETS: AWI CUSTOM GRADE, FLUSH OVERLAY
<br />SYSTEMS MEETING INDICATED REQUIREMENTS FOR THE FOLLOWING TESTS
<br />SUBMITTALS: SUBMIT SHOP DRAWINGS INDICATING PANEL LAYOUT AND DETAILS
<br />IN 10'.
<br />QUALT TY ASSURANCE: FIELD VERIFY DIMENSIONS PRIOR TO SHOP
<br />CONSTRUCTION, NEMA GRADE HGS PLASTIC LAMINATE UNLESS OTHERWISE
<br />PERFORMED BY A QUALIFIED TESTING AGENCY:
<br />OF EACH CONDITION OF INSTALLATION, INCLUDING EDGE CONDITIONS, JOINTS,
<br />WATERSTOPS: FLEX113LE COMPOUND OF BUTYL RUBBER AND SODIUM BENTONITE
<br />FABRICATION. QUALIFY WELDING PROCESSES AND OPERATORS IN
<br />ACCORDANCE WITH AWS DIA AND D1.3. COMPLY WITH RECOMMENDATIONS OF
<br />INDICATED IN COLOR AND FINISH AS SCHEDULED, PROVIDE WHITE MELAMINE
<br />FIRE -RESISTANCE RATED CONSTRUCTION: ASTM El 19 OR UL 263, CLASSIFIED
<br />OPENINGS, PENETRATIONS, FLASHINGS, TRIK AND FASTENERS AND SEALANT
<br />PLACEMENT. INCLUDE PRODUCT DATA AND TEST REPORTS INDICATING
<br />CLAY; "CCW MIRASTOP" BY CARLISLE COATINGS & WATERPROOFING, INC., OR
<br />NAAMM AMP 510-92 METAL STAIRS MANUAL AND NAAMM ANT 521-01 PIPE
<br />FINISH AT ALL INTERIOR AND NON -EXPOSED SURFACES, INCLUDING SHELVES.
<br />AS A COMPONENT OF THE FIRE -RESISTANCE RATED WALL ASSEMBLY
<br />COMPLIANCE WITH REQUIREMENTS.
<br />APPROVED SUBSTITUTE.
<br />RAILING MANUAL.
<br />CABINET HARDWARE: ANSI/BBMA A156.9.
<br />INDICATED.
<br />VAPOR RETARDER: MININIUM 10 MEL PLASTIC SHEET COMPLYING WITH ASTM E1745,
<br />METALS:
<br />DOOR AND DRAWER PULLS: STEEL WIRE PULL WITH POLISHED CHROME FINISH,
<br />POTENTIAL BEAT: NFPA 259, NOT TO EXCEED POTENTIAL BEAT OF FOAM
<br />RIBBED METAL WALL PANELS: MINIMUM 26 GAUGE GALVALUNlE STEEL, SMOOTH
<br />SURFACE, 36" WIDE x 1-1/4" HEIGHT, 12" RIB SPACING, WITH GASKETED EXPOSED
<br />CLASS A. INSTALL IN ACCORDANCE WITH ASIM E1643, LAP JOINTS NIMNIUM 121,
<br />. STEEL WIDE FLANGE SHAPES: ASTM A992.
<br />4" CENTER -TO -CENTER SPACING; ITEM # 11 6.07.23 8 BY HAFELE AMERICA CO., OR
<br />PLASTIC INSULATION IN INTERMEDIATE SCALE MULTI -STORY FIRE TEST.
<br />FASTENING SYSTEM; "PBR"BY MBCI, OR APPROVED SUBSTITUTE.
<br />AND SEAL JOINTS, PERIMETER AND PENETRATIONS WITH MANUFACTUREWS
<br />STEEL CHANNELS, ANGLES, AND PLATES: ASTM A36.
<br />APPROVED SUBSTITUTE.
<br />SURFACE BURNING CHARACTERISTICS: ASTM E84 OR UL 723, ALL
<br />RECOMMENDED MASTIC OR TAPE.
<br />INDIVIDUAL COMPONENTS INCLUDING INSULATION, ADHESIVES, BASE AND
<br />AIR INFILTRATION: MAXIMUNI 0.006 CFM[JSQ FT AT 6.24 LBF/SQ FT STATIC AIR
<br />EXPANSION JOINT FELLER: ASPHALT SATURATED CELLULOSE FIBER STRIPS (ASTM
<br />STEEL PIPE: ASIM A53, GRADE B.
<br />DOOR HINGES: 32mm SYSTEM CONCEALED BINGES WITH 1 10' OPENING ANGLE;
<br />"CLIP TOP" BY BLUM INC., OR APPROVED SUBSTITUTE.
<br />FINISH COATS, AND AIR WATER BARRIER TO HAVE MAXIMUM FLAME
<br />PRESSURE (ASTM E1680).
<br />D1751).
<br />HOLLOW STEEL SECTIONS (HSS): ASIM A500, GRADE B.
<br />SPREAD INDEX OF 25 AND MAXIMUM SMOKE DEVELOPED INDEX OF 450.
<br />WATER PENETRATION: NO UNCONTROLLED WATER PENETRATION AT 20 LBF/SQ
<br />EXPANSION JOINT FILLER FOR SEALANT JOINT: ASIM D4819, TYPE 11, CLOSED CELL
<br />STEEL FLOOR PLATE: ASIM A786, DIAMOND PATTERN.
<br />FILE DRAWER SLIDES: SIDE MOUNTED FULL EXTENSION HEAVY DUTY SLIDES;
<br />"MODEL
<br />INTERMEDIATE SCALE MULTI -STORY FIRE TEST: NFPA 285 (UBC SIT) 26-9),
<br />FT STATIC AIR PRESSURE (ASIM E 1646).
<br />POLYETHYLENE JOINT FILLER, WITH REMOVABLE STRIP FOR SEALANT JOINT;
<br />STEEL SHEET: ASTM A101 1.
<br />4034" BY ACCURIDE INTERNATIONAL INC., OR APPROVED SUBSTITUTE.
<br />PASS ACCEPTANCE CRITERIA.
<br />PREFINISHED: ALUMINUM -ZINC ALLOY -COATED STEEL SHEET (ASIM A792,
<br />"DEK-0-FOAM" BY W.R. MEADOWS, INC., OR APPROVED SUBSTITUTE.
<br />ALUMINUM DIAMOND PLATE: ASTM B632,3003-1114 ALLOY.
<br />DRAWER SLIDES: SIDE MOUNTED FULL EXTENSION SLIDES; "MODEL3832"BY
<br />IGNITION: NFPA 268, PASS ACCEPTANCE CRITERIA.
<br />GRADE 50, COATING CLASS AZ50),2-COAT 70% FLUOROPOLYMER FINISH SYSTEM
<br />FINISHING:
<br />FABRICATION: FABRICATE TO INDICATED SIZES, DIMENSIONS AND DETAILS.
<br />ACCURIDE INTERNATIONAL INC., OR APPROVED SUBSTITUTE.
<br />IN COLOR INDICATED, WITH 25 YEAR WARRANTY.
<br />ASSEMBLE WORK TRUE -TO -LINE, WITH TIGHT, CLOSE FITTING JOINTS. EASE
<br />GROMMETS: 2-1/2" DIAMETER METAL GROMMET, BRUSHED NICKEL FINISH; ITEM
<br />WARRANTY: PROVIDE MANUFACTUREWS STANDARD 10 YEAR SYSTEM
<br />WARRANTY.
<br />GALVALUME FINISH: ALUMINUM -ZINC ALLOY -COATED STEEL SHEET (ASTM
<br />INTERIOR SLABS: FLOAT INTERIOR SLABS AND APPLY TROVv`EL FINISH TO
<br />EXPOSED EDGES AND GRIND ALL EXPOSED WELDS SMOOTH. PROVIDE
<br /># 429.94.658 BY HAFELE AMERICA CO., OR APPROVED SUBSTITUTE.
<br />A792, GRADE 50, COATING CLASS AZ50), UNPAINTED GALVALUNM PLUS FINISH,
<br />PRODUCE UNIFORM TEXTURE FREE OF TROWEL MARKS.
<br />COMPONENTS REQUIRED FOR PROPER ANCHORAGE.
<br />PLASTIC LAMINATE CA13INETS: AWI CUSTOM GRADE, FLUSH OVERLAY
<br />EXTERIOR INSULATION AND FINISH SYSTEM: DRAINAGE TYPE EIFS SYSTEM WITH
<br />WITH 20 YEAR WARRANTY.
<br />EXTERIOR SLABS: FLOAT EXTERIOR SLABS AND APPLY NON -SLIP BROOM FINISH
<br />STEEL BOLLARDS: FABRICATE FROM SCHEDULE 40 STEEL PIPE. PROVIDE CUTOUTS
<br />CONSTRUCTION, NEMA GRADE HGS PLASTIC LAMINATE UNLESS OTHERWISE
<br />AIR/WATER BARRIER; "OUTSULATION PLUS MD SYSTEM" BY DRYVIT SYSTEMS. INC.,
<br />OR APPROVED SUBSTITUTE.
<br />FLORIDA PRODUCT APPROVAL NUMBER: 11917.5.
<br />PERPENDICULAR TO TRAFFIC DIRECTION.
<br />FOR FIXTURES AND HOLES FOR WIRING. FINISH WITH SHOP PRIN11R.
<br />INDICATED IN COLOR AND FINISH AS SCHEDULED, PROVIDE WHITE MELAMINE
<br />FORMED SURFACES: PROVIDE FORM MATERIALS TO PRODUCE A SMOOTH,
<br />STEEL DUMPSTER ENCLOSURE GATES: FABRICATE TO DIMENSIONS AND DETAILS
<br />FINISH AT ALL INTERIOR AND NON -EXPOSED SURFACES, INCLUDING SHELVES.
<br />FLORIDA PRODUCT APPROVAL NUMBER: 2030.12.
<br />TAPERED RIB METAL WALL PANELS: MIND" 24 GAUGE GALVALUME STEEL, ,
<br />UNIFORM TEXTURE FOR CONCRETE EXPOSED TO VIEW, WITH REGULAR SEAM
<br />INDICATED. SUMBIT SEALED SHOP DRAWINGS INDICATING COMPLIANCE WITH
<br />INSTALLATION: CON[PLY WITH AWI SECTION 1700, CUSTOM GRADE. SET UNITS
<br />FLUID APPLIED AIR/WATER BARRIER (AWB): FLUID APPLIED WATER -RESISTIVE
<br />SMOOTH SURFACE, 36" WIDE COVERAGE x 1-1/2" HEIGHT, 7.2" RIB SPACING, WITH
<br />AND TIE PATTERNS. FELL VOIDS AND REMOVE PROJECTIONS TO MATCH FORMED
<br />LOADS INDICATED WITHOUT EXCEEDING ALLOWABLE WORKING STRESS OF
<br />LEVEL, STRAIGHT, AND TRUE, WITH NO DISTORTIONS. SHIM AS REQUIRED WITH
<br />MEMBRANE AND AIR BARRIER SYSTEM SPECIFIED IN SEPARATE SECTION,
<br />GASKETED EXPOSED FASTENING SYSTEM; 7.2 PANEL" BY MBCl, OR APPROVED
<br />CONCRETE COLOR AND TEXTURE.
<br />MATERIALS, INCLUDING ANCHORS AND CONNECTIONS. HOT -DIP GALVANIZE
<br />CONCEALED SHIMS TO A TOLERANCE OF 1/8" IN g'-O" FOR LEVEL, WITH NO
<br />APPROVED BY EFFS MANUFACTURER FOR COMPATIBILITY WITH EFFS.
<br />SUBSTITUTE. PROVIDE REVERSED ROLLED PANELS AT HORIZONTAL APPLICATIONS,
<br />XTARTATMV TM PT Tj4ZWtJPQ4Z'Pn_Q A_n_1r)TXTTxT('� 4ZTTP_PAi"_PQ 4Zt'_PM_P ANM rTjT
<br />WITH FASTENERS INSTALLED IN LOW RIBS.
<br />CURING: COMPLY WITH ACI 308. PROTECT CONCRETE FROM PREMATURE DRYING
<br />AND EXCESSIVE HOT OR COLI)TEMPERATURES IN ACCORDANCE WITH ACT 305 AND
<br />ACI 306. BEGIN CURING AS SOON AS FREE WATER HAS DISAPPEARED FROM
<br />CONCRETE SURFACES AFTER FINISHING.
<br />CONCRETE CURING COMPOUND: ASTM C309 TYPE I-D, DISSIPATING
<br />WATER -BASED LIQUID MEMBRANE -FORMING CONCRETE CURING COMPOUND
<br />WITH FUGITIVE DYE; "I 150-CLEAR" BY W.R. MEADOWS, INC., OR APPROVED
<br />SUBSTITUTE. PREPARE SURFACES AND SPRAY APPLY TO NEW CONCRETE IN
<br />ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
<br />INTERIOR CONCRETE SLAB CONTROL AND CONSTRUCTION JOINT FILLER:
<br />TWO -COMPONENT, SEMI-RlGID EPDXY JOINT FILLER, 100% SOLIDS, NUNINIUM 90
<br />SHORE A HARDNESS (ASTM D 2240), MINIMUM 1,300 PSI TENSIL STRENGTH (ASTM
<br />D638), MINIM[UM 45% ELONGATION (ASTM D638), CUSTOM COLOR; "MM-80" BY
<br />METZGER/MCGUIRE, OR APPROVED SUBSTITUTE. ALLOW CONCRETE SLABS TO
<br />CURE M]NEAUNI 90 DAYS AND STABILIZE INTERIOR TEMPERATURE AT FINAL
<br />OCCUPANCY LEVEL BEFORE INSTALLATION. PREPARE SUBSTRATES AND INSTALL
<br />IN ACCORDANCE WITH THE MANUFACTUREWS INSTRUCTIONS AT INTERIOR
<br />CONCRETE SLAB CONTROL AND CONSTRUCTION JOINTS. PRIME SUBSTRATES AS
<br />RECOMMENDED, INSTALL FULL DEPTH AT CONTROL JOINTS AND MININIUM 2"
<br />DEPTH AT CONSTRUCTION JOINTS, AND TRIM FLUSH WITH CONCRETE SLAB
<br />SURFACE.
<br />4 MASONRY
<br />4.01 MASONRY:
<br />GENERAL: SEE STRUCTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS THAT
<br />APPLY TO THIS SECTION. COMPLY WITH RECOMMENDATIONS OF BIA AND NCM[A.
<br />SUBMITTALS: SUBM[IT PRODUCT DATA FOR REVIEW.
<br />PROJECT CONDITIONS: DO NOT INSTALL WHEN TEMPERATURES ARE BELOW 40
<br />DEGREES F. DO NOT USE FROZEN MATERIALS, OR BUILD ON FROZEN
<br />SUBSTRATES. PROTECT COMPLETED WORK FROM FREEZING FOR MUM" 48
<br />HOURS BY USE OF INSULATING BLANKETS OR BY PROVIDING ENCLOSURE AND
<br />BEAT. COMPLY WITH ACI 530. 1. COVER TOPS OF WALLS AND PROJECTIONS WITH
<br />WATERPROOF SHEETING AT END OF EACH DAY.
<br />CONCRETE MASONRY UNITS (CMU): ASTM C90, HOLLOW LOAD BEARING BLOCK
<br />UNLESS OTHERWISE INDICATED, NOMINAL FACE DIMENSIONS OF 8" HIGH x 16"
<br />LONG (7-5/8"xl5-5/8" ACTUAL) x THICKNESS INDICATED. PROVIDE SPECIAL SHAPES
<br />WHERE REQUIRED FOR LINTELS, BOND BEAMS, CORNERS, JAMBS, SASH, CONTROL
<br />JOINTS, AND OTHER SPECIAL CONDITIONS.
<br />SMOOTH FACE CNIU: NLkNUFACTURER!S STANDARD TEXTURE AND COLOR.
<br />HORIZONTAL JOINT REINFORCEMENT: ASTM A95 1, LADDER TYPE WELDED WIRE
<br />UNITS FABRICATED WITH DEFORMED CONTINUOUS 9 GUAGE SIDE RODS AND PLAIN
<br />9 GAUGE CROSS RODS SPACED @ 16" O.C., WIDTH TO PROVIDE MINIMUM MORTAR
<br />COVERAGE OF 5/8" ON EXTERIOR FACE AND 1/2" ON INTERIOR FACE, HOT -DIP
<br />GALVANIZED (ASTM A153, CLASS B-2). PROVIDE PREFABRICATED "L" SECTIONS AT
<br />CORNERS, AND "T" SECTIONS AT INTERSECTIONS. INSTALL JOINT REINFORCEMENT
<br />AT 16" O.C. VERTICALLY UNLESS OTHERWISE INDICATE, WITH ENDS LAPPED
<br />MINIMUM 12". DO NOT EXTEND JOINT REINFORCEMENT THROUGH CONTROL JOINTS.
<br />CMU CONTROL JOINT: PREMOULDED RUBBER CONTROL JOINT DESIGNED TO FIT
<br />SASH BLOCK; "RS-STANDARD" BY HOHMANN & BARNARD, INC., OR APPROVED
<br />SUBSTITUTE.
<br />LAYING MASONRY: BUILD WALLS TRUE TO LINE, PLUMB AND LEVEL (1/411 IN 101, 1/211
<br />IN TOTAL). BUILD -IN ITEMS AND PROVIDE OPENINGS AND RECESSES FOR OTHER
<br />WORK AS REQUIRED. CUT MASONRY UNITS WITH MOTOR DRIVEN SAWS TO FIT
<br />ADJOINING WORK AND MAINTAIN PATTERN, WITH STRAIGHT UN -CHIPPED EDGES.
<br />LAY UNITS IN RUNNING BOND PATTERN UNLESS OTHERWISE INDICATED, WITH
<br />NOMINAL 3/8" JOINTS, PLUS OR MINUS 1/8" FOR BED, AND PLUS 1/4" OR MINUS 1/8"
<br />FOR BEAD. DO NOT TOOTH -IN UNITS. LAY SOLID UNITS WITH COMPLETELY FILLED
<br />BED AND HEAD JOINTS. LAY HOLLOW CONCRETE MASONRY UNITS WITH FULL
<br />MORTAR COVRAGE ON HORIZONTAL AND VERTICAL FACE SHELLS AND WEBS. FELL
<br />COLLAR JOINTS BETWEEN WYTBES, EXCEPT AT REQUIRED CAVITIES. KEEP
<br />CAVITIES CLEAR OF EXCESS MORTAR. TOOL EXPOSED JOINTS SLIGHTLY CONCAVE
<br />UNLESS OTHERWISE INDICATED, AND STRIKE JOINTS FLUSH WHEN INDICATED TO
<br />BE COVERED WITH ANOTHER MATERIAL. CLEAN MASONRY WITH WATER AND A
<br />SOFT BRISTLE BRUSH.
<br />4.02 MANUFACTURED STONE VENEER
<br />GENERAL: SUBMIT PRODUCT DATA FOR REVIEW.
<br />MANUFACTURED STONE: PRECAST VENEER UNITS CONSISTING OF PORTLAND
<br />CEMENT, LIGHTWEIGHT AGGREGATES, AND MINERAL OXIDE PIGMENTS, WITH
<br />MINIMUM AVERAGE COMPRESSIVE STRENGTH OF 1800 PSI (ASTM C39), WATER
<br />ABSORPTION LESS THAN 22%, LESS THAN 3% WEIGHT LOSS IN FREEZE -THAW TEST
<br />(ASTM C67); MANUFACTURER, PRODUCT AND COLOR AS SCHEDULED. PROVIDE
<br />SPECIAL CORNER SHAPES AT OUTSIDE CORNERS, AND WATERTABLE SILL SHAPES
<br />AS INDICATED.
<br />MORTAR: ASTM C91 MASONRY CEMENT IN COLOR SCHEDULED, ASTM C144
<br />AGGREGATE, AND POTABLE WATER PROPORTIONED IN ACCORDANCE WITH ASTM
<br />C270 FOR TYPE N MORTAR. CALCIUM CHLORIDE IS NOT PERMITTED.
<br />LATH AND TRIM: ASTM C1063, GALVANIZED STEEL.
<br />LATH: ASIM C847,2.5 LB PER SQ YD SELF -FURRED DIAMOND MESH LATH, WITH
<br />GRADE D PAPER BACKING.
<br />CASING BEADS: J-TYPE CASING BEAD WIT14 EXPANDED FLANGE AT ALL
<br />TERMINATIONS, UNLESS OTHERWISE INDICATED.
<br />Vv`EEP SCREEDS: PUNCHED V-STOP WITH 3-1/2" SOLID FLANGE AT FOUNDATION
<br />TERMINATION.
<br />EXPANSION JOINTS: 2 PIECE EXPANSION JOINT WITH INTERLOCKING SOLID
<br />FLANGES AT CHANGES IN SUBSTRATE CONSTRUCTION AND AT CONTROL JOINTS
<br />IN SUBSTRATE.
<br />INSTALLATION: INSTALL IN ACCORDANCE WITH T14E MANUFACTUREKS
<br />INSTRUCTIONS AND THE MASONRY VENNER MANUFACTURERS ASSOCIATION
<br />INSTALLATION GUIDE. DO NOT INSTALL WHEN TEMPERATURES ARE BELOW 40
<br />DEGREES F. PROTECT FROM FREEZING FOR MINUVIUM 48 HOURS. INSTALL LATH AND
<br />METAL TRIM IN ACCORDANCE WITH ASTM C1063, WITH HOT -DIP GALVANIZED
<br />FASTENERS. APPLY NOMINAL 1/2" MORTAR SCRATCH COAT, SCORE, AND MOIST
<br />CURE FOR MINIMUM 48 HOURS.
<br />MANUFACTURED STONE: SET UNITS IN NOMINAL 1/2" MORTAR SETTING BED.
<br />LAY UNITS WITH MINEM[AL JOINTS FOR DRYSTACK APPEARANCE. LAY STONE
<br />WITH LONG AXIS HORIZONTAL. LIMIT UNINTERRUPTED HORIZONTAL JOINTS TO
<br />48" MAXIMUM AND UNINTERRUPTED VERTICAL JOINTS TO 12" MAXIMUNI.
<br />r-I.- I F�fukjfsl r ltvDrut_tl I lkil,413 I u klulvlrl� I w -1 I 11 -ft3 I Ivi ti I /_j 1-11kPlurl 0 -1.
<br />FINISH: REMOVE SCALE, RUST AND OTHER DELETERIOUS MATERIALS FROM
<br />FERROUS METAL IN ACCORDANCE WITH SSPC SP-3 "POWER TOOL CLEANING".
<br />UNLESS INDICATED TO BE GALVANIZED OR POWDER COATED, SHOP PRIME
<br />FERROUS METAL WITH FABRICATORS STANDARD RUST-INIIIBITIVE PAINT, APPLIED
<br />IN ACCORDANCE WITH THE MANUFACTUREWS INSTRUCTIONS TO PROVIDE A
<br />MIND" DRY FILM THICKNESS OF 2.5 MILS.
<br />UNLESS OTHERWISE INDICATED, HOT -DIP GALVANIZE EXPOSED EXTERIOR
<br />ITEMS NOT INDICATED TO BE POWDER COATED, AND ITEMS EMBEDDED IN
<br />CONCRETE. COMPLY WITH ASTM A153 FOR FERROUS METAL HARDWARE, AND
<br />ASTM A123 GRADE 85 FOR FERROUS METAL SHAPES, PLATES AND BARS.
<br />INSTALLATION: INSTALL WORK TRUE -TO -LINE, PLUMB AND LEVEL, ACCURATELY
<br />FITTED AND FREE OF DISTORTION AND DEFECTS. ANCHOR FABRICATIONS
<br />SECURELY IN PLACE WITH COMPATIBLE FASTENERS. TOUCH-UP PAINTING WITH
<br />SAME MATERIAL USED FOR SHOP PAINTING IMMEDIATELY AFTER ERECTION.
<br />REPAIR GALVANIZING TO COMPLY WITH ASTM A780.
<br />FOR EXTERIOR APPLICATIONS AND WHERE BUILT INTO EXTERIOR WALLS, USE
<br />GALVANIZED FASTENERS WITH GALVANIZED FERROUS METAL, USE STAINLESS
<br />STEEL FASTENERS WITH STAINLESS STEEL AND ALUMENUNI MATERIALS, AND
<br />MIUM ITH H MATERIALS.
<br />6 WOOD
<br />6.01 ROUGH CARPENTRY:
<br />GENERAL: STORE WOOD PRODUCTS OFF GROUND TO PREVENT TWISTING OR
<br />WARPING, WITH PROTECTION FROM WEATHER, REPLACE DAMAGED OR
<br />DETERIORATED MATERIALS.
<br />SUBMITTALS: SUBMIT PRODUCT DATA FOR REVIEW.
<br />LUNIBER - BLOCKING: SOUTHERN YELLOW PINE, SPIB NO. 2, S4S AND
<br />GRADESTAMPED, 19% MAXIMUM MOISTURE CONTENT.
<br />PLYWOOD: COMPLY WITH PS-1. PROVIDE APA RATED SHEATHING, EXPOSURE 1,
<br />GRADE C-D OR BETTER, THICKNESS AS INDICATED.
<br />LAMINATED STRAND LUMBER (LSL) - BLOCKING: LSL RINI BOARD, GRADE 1730
<br />Fb/1.35E, MJNIMUM[ 1-3/4" THICKNESS x DEPTH INDICATED, COMPLY WITH ICC ES
<br />ESR-1387 OR 2403, GRADESTAMPED.
<br />PRESERVATIVE PRESSURE TREATMENT (P.T.): PRESERVATIVE PRESSURE TREAT
<br />INTERIOR WOOD FRAMING INDICATED AS T.T." WITH ZINC BORATE TO COMPLY
<br />WITH AWPA STANDARD Ul FOR USE CATAGORY 2, AND KILN DRIED AFTER
<br />TREATMENT TO MAXIMUNt 19% MOISTURE CONTENT.
<br />FIRE RETARDANT TREATMENT (FRT): PRESSURE TREAT WOOD INDICATED AS TRT"
<br />TO CONIPLY WITH AWPA STANDARD P49 TO PROVIDE WOOD WITH A FLAME SPREAD
<br />AND SMOKE DEVELOPED RATING OF LESS THAN 25 WHEN TESTED IN ACCORDANCE
<br />WITH ASTM E84 FOR MINIMUM 30 MINUTE DURATION. PROVIDE TREATMENT TYPE
<br />RECOMMENDED BY TREATMENT MANUFACTURER FOR INTENDED USE. TREATMENT
<br />TO PROVIDE PROTECTION AGAINST TERMITES AND FUNGAL DECAY, AND BE
<br />REGISTERED WITH EPA FOR USE AS A WOOD PRESERVATIVE. TREATED WOOD IN
<br />CONTACT WITH CARBON STEEL AND ALUMINUM TO HAVE CORROSION RATES OF
<br />LESS THAN I MIL PER YEAR WHEN TESTED IN ACCORDANCE WITH FED SPEC
<br />MEL-L- 19140, PARAGRAPH 4.6.5.2. KILN DRY AFTER TREATMENT TO MAXIMUM
<br />MOISTURE CONTENT OF 19% FOR LUMBER AND 15% FOR PLYWOOD, AND STAMP
<br />EACH PIECE WITH UL LABEL CLASSIFICAION.
<br />FASTENERS: PROVIDE FASTENERS AS REQUIRED, CORROSION RESISTANT WHERE
<br />EXPOSED TO THE EXTERIOR OR IN CONTACT WITH PRESERVATIVE PRESSURE
<br />TREATED OR FIRE RETARDANT TREATED WOOD.
<br />INSTALLATION: DISCARD NUTERIAL THAT IS TOO SHORT FOR OPTIMUM JOINT
<br />ARRANGEMENT, SPLIT, WARPED, BOWED, TWISTED, OR OTHERWISE DEFECTIVE. SET
<br />CARPENTRY WORK TO REQUIRED LINES AND ELEVATIONS, WITH MEMBERS PLUMB,
<br />LEVEL, SQUARE, AND STRAIGHT (1/4" IN 10', 1/2" TOTAL). CUT MEMBERS TO FIT
<br />TIGHTLY, AND SECURELY ATTACH TO SUBSTRATES AND SUPPORTING MEMBERS
<br />WITH FASTENERS THAT WILL NOT PENETRATE MEMBER WHERE OPPOSITE SIDE
<br />WELL BE EXPOSED TO VIEW OR RECEIVE FINISH MATERIALS. PROVIDE BLOCKING AS
<br />REQUIRED FOR ATTACHMENT OF OTHER WORK.
<br />6.02 INSULATING SHEATHING:
<br />GENERAL: PROTECT PRODUCTS FROM EXPOSURE TO WEATHER AND CONTACT WITH
<br />WET SURFACES.
<br />SUBMITTALS: SUBMIT PRODUCT DATA FOR REVIEW.
<br />MINERAL WOOL BOARD INSULATION: ASTM C612 TYPE IVB, THICKNESS INDICATED,
<br />M[INIMUM R-VALUE OF 4.0 PER INCH AT 75 DEG F (ASIM C5 I 8), MAXIMUM FLAME
<br />SPREAD INDEX OF 0 AND MAXIMUM SMOKE DEVELOPED INDEX OF 0 (ASTM E84),
<br />MININIUM DENSITY OF I I PCF (ASTM C303); "COMTORTBOARD 1 1 0" BY ROCKWOOL,
<br />INC., OR APPROVED SUBSTITUTE.
<br />INSTALLATION: INSTALL IN ACCORDANCE WITH THE MANUFACTUREWS
<br />INSTRUCTIONS. ATTACH TO METAL FRAMING WITH MANUFACTUREKS
<br />RECOMMENDED CORROSION RESISTANT SCREWS AND WASHERS COMLYING WITH
<br />ASTM C 1002 OR ASTM C954.
<br />6.03 GYPSUM SHEATHING:
<br />GENERAL: PROTECT PRODUCTS FROM EXPOSURE TO WEATHER AND CONTACT WITH
<br />WET SURFACES.
<br />SUBMITTALS: SUBMIT PRODUCT DATA FOR REVIEW.
<br />GYPSUM SHEATHING: ASIM C 1 177, WATER-RESISTANT GYPSUM CORE PANELS WITH
<br />FIBERGLASS MAT FACINGS, MAXIMUM FLAME SPREAD INDEX OF 0 AND MAXIMUM
<br />SMOKE DEVELOPED INDEX OF 0 (ASTNI E84), THICKNESS AND TYPE AS INDICATED;
<br />"SECUROCK" BY UNITED STATES GYPSUM COMPANY, "DENSGLAS GOLD" BY
<br />GEROGIA-PACIFIC BUILDING PRODUCTS, OR APPROVED SUBSTITUTE.
<br />.
<br />INSTALLATION: INSTALL IN ACCORDANCE WITH ASTM C 1280, GA-253, AND THE
<br />MANUFACTUREWS INSTRUCTIONS. ATTACH TO METAL FRAMING WITH
<br />NIANUFACTUREWS RECOMMENDED CORROSION RESISTANT SCREWS COMLYING
<br />WITH ASIM C 1002 OR ASTM C954.
<br />FASTENER SPACING: MINIMUM 1-518" LENGTH #6 BUGLE BEAD SCREWS SPACED
<br />8" O.C. M[AXINIUM INTO FRAMING SPACED 16" O.C. MAXIM[UM, EXCEPT SPACED 6"
<br />O.C. MAXIMUM WITHIN 10'OF BUILDING CORNERS (ZONE 5).
<br />WOODWORK TO FIT ADJOINING WORK, AND REATORE . FINISH OF CUT SURFACES.
<br />ANCHOR SECURELY TO SUBSTRATES WITH CONCEALED FASTENERS. ADJUST
<br />HARDWARE TO ALIGN DOORS AND DRAWERS, AND TO PROVIDE UNENCUMBERED
<br />OPERATION.
<br />6.05 SOLID SURFACE FABRICATIONS:
<br />GENERAL: FABRICATOR AND INSTALLER TO BE CERTIFIED BY SOLID SURFACE
<br />MANUFACTURER. SUBMIT PRODUCT DATA AND SHOP DRAWINGS OF SOLID
<br />SURFACE FABRICATIONS FOR REVIEW. SOLID SURFACE MATERIAL TO COMPLY
<br />WITH ASIM E84 CLASS A REQUIREMENTS FOR SURFACE BURNING
<br />CHARACTERISTICS, WITH MAXIMUM FLAME SPREAD INDEX OF 25 AND MAXIMUM
<br />SMOKE DEVELOPED INDEX OF 450.
<br />SOLID SURFACE MATERIAL: CAST, NONPOROUS, QUARTZ BASED COMPOSITE WITH
<br />THROUGH BODY COLORS AS SCHEDULED. PROVIDE JOINT ADHESIVES AND
<br />COLOR -MATCHED SEALANTS AS RECOMMENDED BY THE MANUFACTURER.
<br />FABRICATION: COMPLY WITH THE MANUFACTURER!S RECONIMENDATIONS.
<br />COUNTERTOPS: FABRICATE COUNTERTOPS IN ACCORDANCE WITH THE
<br />KkNUFACTURER!S RECOMMENDATIONS FROM 3/4" THICK MATERIAL, WITH
<br />INCONSPICUOUS ADHERED REINFORCED JOINTS, EASED EDGES, 3/4" RADIUSED
<br />OUTSIDE CORNERS, AND MATTE FINISH. FABRICATE BACK AND SIDE SPLASHES
<br />FROM 1/2" THICK MATERIAL TO MATCH COUNTEREOPS. PROVIDE RECESSES AND
<br />CUTOUTS TO ACCOMMODATE MOUNTING HARDWARE, SUPPORTS, FIXTURES,
<br />AND WORK BY OTHER TRADES.
<br />SELLS: FABRICATE FROM 3/4" THICK MATERIAL, WITH EASED EDGES AND MATTE
<br />FINISH. PROVIDE FULL LENGTH PIECES WHERE POSSIBLE, AND INCONSPICUOUS
<br />ADHERED REINFORCED JOINTS WHERE SELLS EXCEED MAXIMUM MATERIAL
<br />LENGTH.
<br />INSTALLATION: INSTALL IN ACCORDANCE WIT14 THE MANUFACTUREWS
<br />INSTRUCTIONS. SET FABRICATIONS PLUMB, LEVEL, STRAIGHT, AND TRUE, AND
<br />SCRIBED TO ADJACENT SURFACES. INSTALL COUNTERTOPS WITH CONCEALED
<br />SHIMS TO A TOLERANCE OF 1/8" IN 8'-O" FOR LEVEL AND LINE. ALIGN ADJACENT
<br />COUNTERTOPS AND FORM INCONSPICUOUS ADHERED REINFORCED JOINTS. ADHERE
<br />OR ATTACH SECURELY TO SUBSTRATES WITH CONCEALED FASTENERS. ADHERE
<br />BACKSPLASHES AND SIDESPLASHES TO WALLS AND COUNTERTOPS WITH
<br />MANUFACTUREWS COLOR MATCHED SEALANT.
<br />6.06 SLATWALL PANEL SYSTEMS
<br />GENERAL: PROVIDE SLATWALL PANEL SYSTEMS WITH NLAXIMUM FLAME SPREAD
<br />INDEX OF 25 AND MAXIMUM SMOKE DEVELOPED INDEX OF 450 (ASIM E84).
<br />MAINTAIN TEMPERATURE AND BlfMIDITY RANGE RECOMMENDED BY
<br />MANUFACTURER FOR AT LEAST 72 HOURS BEFORE, DURING AND AFTER
<br />INSTALLATION.
<br />SUBMITTALS: SUBMIT PRODUCT DATA FOR REVIEW.
<br />SLATWALL PANELS: 2'-O" HIGH x 8'-O" WIDE x NOMINAL 3/4" THICK MDF CORE
<br />PANELS WITH TEXTURED FACE AND ALUMINUM GROOVE INSERTS AT 6" O.C.;
<br />MANUFACTURER, PRODUCT AND COLOR AS SCHEDULED. PROVIDE
<br />MANUFACTUREWS RECOMMENDED FASTENERS AND MATCHING TRIM.
<br />INSTALLATION: INSTALL IN ACCORDANCE WITH THE MANUFACTUREWS
<br />INSTRUCTIONS. SET UNITS PLUMB, LEVEL, AND TRUE TO LINE. PRE -DRILL
<br />ALUMINUM GROOVE INSERTS, AND SCREW ATTACH INTO FRAMING MEMBERS.
<br />PROVIDE TRIM AT EXPOSED EDGES.
<br />7 THERMAL AND MOISTURE PROTECTION
<br />7.01 FLUID -APPLIED WATERPROOFING
<br />GENERAL: SUBMIT PRODUCT DATA AND INSTALLATION INSTRUCTIONS FOR
<br />REVIEW.
<br />PROJECT CONDITIONS: PERFORM WORK ONLY WHEN EXISTING AND
<br />FORECASTED WEATHER CONDITIONS ARE WITHIN THE LEWIS RECOMMENDED
<br />BY THE WATERPROOFING MANUFACTURER. DO NOT INSTALL WHEN
<br />TEMPERATURES ARE EXPECTED TO FALL BELOW 40 DEGREES F WITHIN 4 HOURS
<br />AFTER APPLICATION, OR TO DANT OR CONTAMINATED SURFACES.
<br />WARRANTY: PROVIDE MANUFACTUREWS 5 YEAR SYSTEM WARRANTY.
<br />FLUID WATERPROOFING: ASTM C836, COLD LIQUID -APPLIED, SINGLE -COMPONENT,
<br />SOLVENT -FREE, NON-SBRINK ELASTOMERIC WATERPROOFING MEMBRANE,
<br />M[INIMUNI 82% SOLIDS CONTENT BY WEIGHT (ASTM D1644), MINIMUM 400%
<br />ELONGATION (ASTM D412), AND MAXIMUN[ 0.08 PERMS WATER VAPOR
<br />TRANSMISSION (ASTM E96 METHOD B). PROVIDE MANUFACTUREWS RECONIMENDED
<br />PREVIERS, SEALANTS, AND ACCESSORIES.
<br />PRODUCT: "HYDRALASTIC 836" BY W.R. MEADOWS, INC., OR APPROVED
<br />SUBSTITUTE.
<br />DRAINAGE BOARD: MOLDED POLYSTYRENE DRAINAGE SHEET WITH NONWOVEN
<br />GEOTEXTILE FABRIC FACING, MINIMUM 0.40" THICK, MINIMUM FABRIC APPARENT
<br />OPENING SIZE 70 US SID SIEVE (ASIM D475 1), MINDAUM 15 ' 000 PSF COMPRESSIVE
<br />STRENGTH (ASTM D1621 MOD), AND MR41MUM 17 GPM/FT CORE IN PLANE FLOW
<br />RATE AT GRADIENT 1.0 (ASIM D4716).
<br />PRODUCT: "MEL-DRAIN 5035" BY W.R. MEADOWS, INC., OR APPROVED
<br />SUBSTITUTE.
<br />INSTALLATION: INSTALL IN ACCORDANCE WITH THE MANUFACTUREWS
<br />INSTRUCTIONS. REMOVE PROJECTIONS, FILL VOIDS, AND CLEAN SURFACES TO
<br />RECEIVE WATERPROOFING. APPLY WATERPROOFING MEMBRANE IN ACCORDANCE
<br />WITH THE MANUFACTUREWS INSTRUCTIONS TO PRODUCE A SEANILESS MEMBRANE
<br />WITH INDICATED MINIMUM CURED THICKNESS. ALLOW MEMBRANE TO CURE.
<br />INSTALL DRAINAGE BOARD.
<br />VERTICAL SURFACES: MINIMUM CURED MEMBRANE THICKNESS OF 60 MILS.
<br />7.02 INSULATION
<br />GENERAL: PROTECT INSULATION PRODUCTS FROM EXPOSURE TO WEAT14ER AND
<br />CONTACT WITH WET SURFACES.
<br />SUBMITTALS: SUBMIT PRODUCT DATA FOR REVIEW.
<br />BATT INSULATION: ASTM C665, TYPE 1, UNFACED GLASS FIBER THERMAL BATT
<br />INSULATION, MAXIMUNI FLAME SPREAD INDEX OF 25 AND MAXIMUM SMOKE
<br />DEVELOPED INDEX OF 50 (ASTM E84).
<br />VINYL FACED METAL BUILDING INSULATION: ASIM C991, TYPE 1, FLEXIBLE GLASS
<br />FIBER INSULATION. PROVIDE WHITE POLYPROPYLENE LAMINATED FACING ON
<br />INTERIOR FACE OF FIBERGLASS, MAXIMUM FLAME SPREAD INDEX OF 25 AND
<br />MAXEMUM[ SMOKE DEVELOPED INDEX OF 50 (ASTM E84), AND PERMEANCE NOT
<br />EXCEEDING 0.05 WHEN TESTED IN ACCORDANCE WITH ASTM E96. PROVIDE
<br />EXTENDED TABS TO FACILITATE ATTACHMENT OVER PURLINS.
<br />YANURATE CORE WITH 26 GAUGE STEEL CLADDING,
<br />AZ50 GALVALUME FINISH, MAXIMUM FLAME SPREAD INDEX OF 25 AND MAXIMUM
<br />SMOKE INDEX OF 150 (ASTM E84), I " THICK x MINIMUM[ 2-1/2" WIDE; "SNS THERMAL
<br />SPACE" BY STEEL BUILDING INSULATION, OR APPROVED SUBSTITUTE.
<br />INSTALLATION: INSTALL IN ACCORDANCE WITH THE MANUFACTURERS
<br />INSTRUCTIONS. PROVIDE THICKNESS OF INSULATION INDICATED OR REQUIRED TO
<br />ACHIEVE R-VALUE INDICATED. SET VAPOR -RETARDER MEMBRANE TO
<br />CONDITIONED SIDE OF CONSTRUCTION. CUT AND FIT TIGHTLY AROUND
<br />OBSTRUCTIONS AND FELL VOIDS TO PROVIDE CONTINUOUS FULL -DEPTH LAYER OF
<br />INSULATION. SEAL ALL PENETRATIONS THROUGH EXTERIOR WALLS AND
<br />UPPERMOST CEILING/ROOF WITH SEALANT,
<br />SEAL ALL SEAMS AND PENETRATIONS IN EXPOSED FACINGS WITH
<br />MANUFACTUREWS RECOMMENDED TAPE.
<br />ADHESIVE: POLYMER MODIFIED CEMENT BASED ADHESIVE,
<br />BASE COAT: POLYMER MODIFIED CEMENT BASED ADHESIVE. PROVIDE ACRYLIC
<br />BASED WATERPROOF BASE COAT MIXED WITH PORTLAND CEMENT ON SLOPED
<br />SURFACES.
<br />REINFORCING MESH: TREATED GLASS FIBER MESH REINFORCEMENT EMBEDDED
<br />IN BASE COAT TO ACHIEVE STANDARD EIMA INIPACT CLASSIFICATION. PROVIDE
<br />ULTRA -HIGH IMPACT MESH AT LOCATIONS SUBJECT TO PEDESTRIAN TRAFFIC
<br />LESS THAN 6'ABOVE GRADE.
<br />FINISH: ACRYLIC BASED TEXTURED COATING IN COLOR AND TEXTURE
<br />INDICATED.
<br />INSULATION: EfFS SYSTEM MANUFACTUREWS RECOMMENDED EXPANDED
<br />POLYSTYRENE INSULATION BOARD COMPLYING WITH ASTM C578 TYPE 1, ASTM
<br />E2430, AND EIMA SPECIFICATIONS. INSULATION TO BE MINIMUNI V TIUCK, WITH
<br />POTENTIAL BEAT NOT TO EXCEED THAT OF TESTED NFPA 285 ASSEMBLY (NFPA
<br />259), AND BEAR THE LABEL OF AN APPROVED AGENCY.
<br />PORTLAND CEMENT: ASTM C C150, TYPE 1.
<br />WATER: POTABLE.
<br />INSTALLATION: INSTALL EIFS IN ACCORDANCE WITH THE MANUFACTUREWS
<br />INSTRUCTIONS.
<br />7.04 WATER RESISTIVE BARRIER (WRB
<br />GENERAL: SUBMIT PRODUCT DATA AND INSTALLATION INSTRUCTIONS FOR
<br />REVIEW.
<br />WATER RESISTIVE BARRIER (WRB): NON -PERFORATED, NON -WOVEN, SPUNBONDED
<br />POLYOLEFIN; "TYVEK COMTAERCIALV�TRAP" BY DUPONT, OR APPROVED
<br />SUBSTITUTE. PROVIDE MANUFACTURERS RECOMMENDED FASTENERS AND SEAM
<br />TAPE.
<br />SELF -ADHERED FLASHING (SAF): BUTYL RUBBER ON POLYETHYLENE LAMINATE
<br />CARRIER SHEET, 30 MEL MRS4UMUNI TOTAL THICKNESS, CONTLYING WITH AAMA
<br />711-07, CLASS A, LEVEL 3; "STRAIGHT FLASH" BY DUPONT, OR APPROVED
<br />SUBSTITUTE. PROVIDE TLEXWRAP NF" AT SELLS AND WHERE FLEXIBLE SAF IS
<br />REQUIRED.
<br />INSTALLATION: INSTALL IN ACCORDANCE WITH THE MANUFACTUREWS
<br />INSTRUCTIONS. APPLY OVER EXTERIOR WALL SUBSTRATE TO PROVIDE A
<br />CONTINUOUS DRAINAGE PLANE. COVER EXTERIOR WALL SUBSTRATE WITH
<br />CONTINUOUS LAYER OF WRB APPLIED TO DIVERT WATER TO THE EXTERIOR, AND
<br />FASTEN TO SUBSTRATE. WEATBERLAP HORIZONTAL AND VERTICAL JOINTS
<br />MINIMUM 6", AND EXTEND WRB MINIMUM 12" BEYOND CORNERS. LAP WRB
<br />MINIMUM 4" OVER ADJACENT FLASHINGS. PROVIDE SAF FLASHING AT ALL WALL
<br />OPENINGS, FABRICATING SILL PAN FLASHING FROM FLEX03LE SAF, AND INTEGRATE
<br />INTO WRB TO Nt4JNTAIN DRAINAGE TO EXTERIOR. SEAL ALL JOINTS WITH SEAM
<br />TAPE.
<br />7.05 FLUID APPLIED AIR/WATER BARRIER (AWB)
<br />GENERAL: DO NOT INSTALL WHEN AIR OR WALL TENTERATURES WILL BE BELOW
<br />40 DEGREES F OR ABOVE 100 DEGREES F WITHIN 24 HOURS OF APPLICATION. DO NOT
<br />INSTALL DURING INCLEMENT WEATHER UNLESS PROTECTION IS PROVIDED.
<br />SUBMITTALS: SUBMIT PRODUCT DATA AND INSTALLATION INSTRUCTIONS FOR
<br />REVIEW.
<br />PERFORMANCE REQUIREMENTS: PROVIDE AIR WATER BARRIER SYSTEM
<br />MEETING INDICATED REQUIREMENTS FOR THE FOLLOWING TESTS PERFORMED
<br />BY A QUALIFIED TESTING AGENCY:
<br />SURFACE BURNING CHARACTERISTICS: ASTM E84 OR UL 723, MAXIMUM
<br />FLAME SPREAD INDEX OF 25 AND MAXINIUM SMOKE DEVELOPED INDEX OF
<br />450.
<br />FLUID APPLIED AIR/WATER BARRIER (AWB): FLUID APPLIED WATER -RESISTIVE
<br />MEMBRANE AND AIR BARRIER SYSTEM, VAPOR PERMEABLE, FOR USE BENEATH
<br />EIFS OR OTHER CLADDING. PROVIDE NIANUFACTURER!S RECOMMENDED MESH
<br />TAPE, FLUID APPLIED FLASHING AND JOINT COMPOUND, SEALANT, AND RELATED
<br />ACCESSORIES.
<br />PRODUCT AND MANUFACTURER: "BACKSTOP NT - TEXTURE" BY DRYVIT, OR
<br />APPROVED SUBSTITUTE.
<br />INSTALLATION: INSTALL IN ACCORDANCE WITH THE MANUFACTURER!S
<br />INSTRUCTIONS. APPLY OVER EXTERIOR WALL SUBSTRATE TO PROVIDE A
<br />CONTINUOUS DRAINAGE PLANE. PROTECT OTHER SURFACES FROM OVERSPRAY.
<br />TAPE AND APPLY MEMBRANE TO ALL SUBSTRATE JOINTS AND CORNERS, AND
<br />APPLY MEMBRANE TO ALL SUBSTRATE FASTENER BEADS. COVER ENTIRE WALL
<br />SURFACE WITH MEMBRANE, INCLUDING PREVIOUSLY TREATED JOINTS. PROVIDE
<br />FLUED APPLIED FLASHING AT ALL OPENINGS, ADJACENT FLASHINGS, SUBSTRATE
<br />MOVEMENT JOINTS, TRANSITIONS, AND TERMINATIONS TO DIVERT WATER TO THE
<br />EXTERIOR. INTEGRATE MEMBRANE WITH ADJACENT AIR BARRIER COMPONENTS TO
<br />PROVIDE CONTINUOUS AIR TIGHT CONSTRUCTION.
<br />7.06 METAL ROOF PANELS
<br />GENERAL: PROVIDE STRUCTURAL METAL ROOF PANEL SYSTEMS MEETING
<br />INDICATED REQUIREMENTS AS DETERMINED BY QUALIFIED TESTING FACILITY:
<br />STRUCTURAL PERFORMANCE: WITHSTAND DESIGN WIND, SNOW, AND OTHER
<br />LIVE LOADS INDICATED, WITH MAXIM[UM[ DEFLECTION OF 1/180 OF THE SPAN.
<br />WIND UPLIFT RESISTANCE: COMPLY WITH UL 580 FOR CLASS UL-90.
<br />THERMAL MOVEMENT: ALLOW FOR THERMAL MOVEMENT AND DEFLECTION
<br />FROM AMBIENT AND INTERNAL TEMPERATURE VARIATIONS.
<br />SUBMITTALS: SUBMIT SHOP DRAWINGS INDICATING PANEL LAYOUT AND DETAILS
<br />OF EACH CONDITION OF INSTALLATION, INCLUDING EDGE CONDITIONS, JOINTS,
<br />OPENINGS, PENETRATIONS, FLASHINGS, TRIM, AND FASTENERS AND SEALANT
<br />PLACEMENT. INCLUDE PRODUCT DATA AND TEST REPORTS INDICATING
<br />COMPLIANCE WITH REQUIREMENTS.
<br />METAL TRAPEZOIDAL SEAM ROOF PANELS: MECHANICALLY SEAMED, CONCEALED
<br />FASTENER, TRAPEZOIDAL SEAM STRUCTURAL METAL ROOF PANELS FABRICATED
<br />FROM MININ[UNI 24 GAUGE STEEL WITH SMOOTH SURFACE; "DOUBLE-LOK" BY
<br />MBCI, OR APPROVED SUBSTITUTE. FABRICATE PANELS IN CONTINUOUS LENGTHS
<br />WHERE POSSIBLE.
<br />WEATHER TIGHTNESS WARRANTY: 15 YEARS FROM DATE OF SUBSTANTIAL
<br />COMPLETION.
<br />AIR INFILTRATION: MAXIMUM 0.014 CFWSQ FT AT 6.24 LBF/SQ FT STATIC AIR
<br />PRESSURE (ASTM E1680).
<br />WATER PENETRATION: NO UNCONTROLLED WATER PENETRATION AT 12 LBF/SQ
<br />FT STATIC AIR PRESSURE (ASTM E 1 646).
<br />PANEL SIZE: 24" WIDTH x 3" HEIGHT TRAPEZOIDAL DOUBLE FOLDED JOINT.
<br />PROVIDE WINDCLAMPS WHERE REQUIRED TO WITHSTAND DESIGN WIND LOADS.
<br />PREFINISBED: ALUNfiNUM-ZINC ALLOY -COATED STEEL SHEET (ASTM A792,
<br />GRADE 50, COATING CLASS AZ50),2-COAT 70% FLUOROPOLYMER FINISH SYSTEM
<br />IN COLOR INDICATED, WITH 25 YEAR WARRANTY.
<br />GALVALUME FINISH: ALUNIINUNI-ZINC ALLOY -COATED STEEL SHEET (ASIM
<br />A792, GRADE 50, COATING CLASS AZ55), UNPAINTED GALVALUME PLUS FINISH,
<br />WIT14 20 YEAR WARRANTY.
<br />FLORIDA PRODUCT APPROVAL NUMBER: 11 819.2.
<br />ACCESSORIES: PROVIDE NtkNUFACTURER!S RECOM[MENDED, TWO-PEECE FLOATING
<br />CLIPS, FASTENERS, CLOSURES, SEALANTS, AND ACCESSORIES. PROVIDE FLASHING
<br />AND TRIN4 TO MATCH METAL PANEL MATERIAL, THICKNESS AND FINISH.
<br />INSTALLATION: INSTALL IN ACCORDANCE WITH THE MANUFACTURER!S
<br />INSTRUCTIONS. PROVIDE SUPPLEMENTAL FRAMING SUPPORTS IN ACCORDANCE
<br />WITH ASTM C754. SET UNITS TRUE TO LINE, LEVEL, AND PLUNIB (1/16" AT JOINT
<br />BETWEEN ADJACENT PANELS, 1/8" IN 10', 1/4" TOTAL).
<br />AIR INFILTRATION: NIAXINIUM 0.000 CFNVSQ FT AT 6.24 LBF/SQ FT STATIC AIR
<br />PRESSURE (ASTM E283).
<br />WATER PENETRATION: NO UNCONTROLLED WATER PENETRATION AT 13.24
<br />LBF/SQ FT STATIC AIR PRESSURE (ASTM E3 3 1).
<br />PREFINISBED: ALUMINUM -ZINC ALLOY -COATED STEEL SHEET (ASTM A792,
<br />GRADE 50, COATING CLASS AZ50),2-COAT 70% FLUOROPOLYMER FINISH SYSTEM
<br />IN COLOR INDICATED, WITH 25 YEAR WARRANTY.
<br />FLORIDA PRODUCT APPROVAL NUMBER: 15159. 1.
<br />ACCESSORIES: PROVIDE MANUFACTUREKS RECOMMENDED FASTENERS, CLOSURES,
<br />TAPE SEALERS, SEALANTS, AND ACCESSORIES. PROVIDE FLASHING AND TRIM TO
<br />MATCH METAL PANEL MATERIAL, THICKNESS AND FINISH.
<br />INSTALLATION: INSTALL IN ACCORDANCE WIT14 THE MANUFACTURER!S
<br />INSTRUCTIONS. PROVIDE SUPPLEMENTAL FRAMING SUPPORTS IN ACCORDANCE
<br />WITH ASIM C754. SET UNITS TRUE TO LINE, LEVEL, AND PLUMB (1/16" AT JOINT
<br />BETWEEN ADJACENT PANELS, 1/8" IN I O', 1/4" TOTAL).
<br />I W0�1"10867-
<br />GENERAL: COMPLY WITH RECOMMENDATIONS OF SMACNA "ARCHITECTURAL
<br />SHEET METAL MANUAL". FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION.
<br />SUBMIT SHOP DRAWINGS INDICATING LAYOUT AND DETAILS, INCLUDING JOINTS
<br />AND ATTACHMENTS,
<br />FABRICATION AND INSTALLATION: FABRICATE AND INSTALL IN ACCORDANCE
<br />WITH SMACNA "ARCHITECTURAL SHEET METAL MANUAL". INSTALL EXTERIOR
<br />FLASHING AND SHEET METAL WATER AND WEATHER TIGHT, TRUE TO LINE AND
<br />LEVEL. HEM EXPOSED EDGES OF FABRICATED SHEET METAL. SEPARATE METALS
<br />FROM CORROSIVE SUBSTRATES. PROVIDE FOR THERMAL EXPANSION AND
<br />BUILDING MOVEMENT. FABRICATE CLEATS AND ATTACHMENT DEVICES FROM
<br />SAME MATERIAL OR COMPATABLE NONCORROSIVE MATERIAL, THICKNESS AS
<br />RECOMMENDED BUT NOT LESS THAN METAL BEING SECURED. ANCHOR WORK IN
<br />PLACE WITH NON -CORROSIVE FASTENERS, CONCEALED WHERE POSSIBLE SEAL
<br />JOINTS AND LAPS WITH ELASTOMERIC SEALANT.
<br />GUTTERS AND DOWNSPOUTS: FABRICATE FROM MINIMUM 24 GAUGE
<br />GALVALUME STEEL (ASIM A792, GRADE 50, COATING CLASS AZ50), WITH
<br />2-COAT FLUOROPOLYMER FINISH SYSTEM IN COLOR INDICATED. ATTACH
<br />DOWNSPOUTS TO GUTTERS AND STRAPS WITH STAINLESS STEEL RIVETS.
<br />EXPOSED METAL TRIM: FABRICATE FROM MINIMUM 26 GUAGE GALVALUME
<br />STEEL (ASTM A792, GRADE 50, COATING CLASS AZ50), WITH 2-COAT
<br />FLUOROPOLYMER FINISH SYSTEM IN COLOR INDICATED.
<br />SELF -ADHERED FLASHING (SAF): BUTYL RUBBER ON POLYETHYLENE LANffNATE
<br />CARRIER SHEET, COMPLYING WITH AAMA 711-07, TYPE A, LEVEL 3.
<br />7.09 METAL ROOF EDGE SPECIALTIES
<br />GENERAL: PROVIDE ROOF EDGE SYSTEMS CONTLYING WITH THE FOLLOWING
<br />PERFORMANCE CRITERIA:
<br />METAL COPING SYSTEMS: ANSUSPRI/FM 4435 STANDARD ES-1 TEST RE-3.
<br />PREFINISHED METAL COPING SYSTEM: FABRICATE FROM PREFINISBED 24 GAUGE
<br />GALVANIZED STEEL, DIMENSIONS AS INDICATED, WITH CONCEALED 6" SPLICE
<br />PLATE AT BUTT JOINTS AND CONTINUOUS 20 GAUGE GALVANIZED STEEL ANCHOR
<br />CLEAT; TORMED COPING" BY OMG EDGESYSTEMS, OR APPROVED SUBSTITUTE.
<br />PROVIDE MATCHING CORNERS, END CAPS, AND TERMINATIONS WITH MITERED AND
<br />FULLY WELDED SEAMS, AND STAINLESS STEEL FASTENERS.
<br />MIAMI-DADE COUNTY NOA NUMBER: 17-0822.08.
<br />FINISH: 70% FLUOROPOLYMER FINISH COMPLYING WITH AAMA 2605, MR41MUM 1.2
<br />MIL DRY FILM THICKNESS, COLOR AS SCHEDULED.
<br />INSTALLATION: INSTALL IN ACCORDANCE WITH THE MANUFACTUREWS
<br />INSTRUCTIONS TO PROVIDE A WATERTIGHT SYSTEM THAT WILL ACCOMMODATE
<br />THERMAL MOVEMENT.
<br />7.10 SEALANTS
<br />GENERAL: SUBMIT PRODUCT DATA FOR REVIEW.
<br />SEALANTS: PROVIDE JOINT SEALANTS, JOINT FILLERS, AND OTHER RELATED
<br />MATERIALS THAT ARE COMPATIBLE WITH ONE ANOTHER AND WITH JOINT
<br />SUBSTRATES UNDER SERVICE AND APPLICATION CONDITIONS, AS RECOMMENDED
<br />BY THE MANUFACTURER. INSTALL SEALANTS IN COM[PLIANCE WITH THE
<br />MANUFACTUREWS INSTRUCTIONS AND ASTM Cl 193.
<br />EXTERIOR ELASTOMERIC SEALANT: AT EXTERIOR JOINTS PROVIDE
<br />MULTI -COMPONENT CHENUCALLY-CURING, NON -SAG POLYURETHANE SEALANT
<br />COMPLYING WITH ASIM C920 TYPE M, GRADE NS, CLASS 50, USE M, A, G, T, AND
<br />0; "DYNATROL 11" BY PECORA CORPORATION, OR APPROVED SUBSTITUTE.
<br />CUSTOM COLORS TO BE SELECTED. PRIME SUBSTRATES AS RECOMMENDED AND
<br />INSTALL OVER PLASTIC FOAM BACKER ROD OR BOND BREAKER TAPE.
<br />INTERIOR GENERAL SEALANT: AT INTERIOR JOINTS NOT SUBJECT TO
<br />MOVEMENT, PROVIDE NON -SAG, MILDEW RESISTANT, PAINTABLE, ACRYLIC
<br />LATEX SEALANT COMPLYING WITH ASTM C834; "AC-20" BY PECORA
<br />CORPORATION, OR APPROVED SUBSTITUTE. INSTALL OVER CLOSED -CELL
<br />POLYURETHANE FOAM BACKER ROD OR BOND BREAKER TAPE.
<br />INTERIOR FLOOR EXPANSION JOINT SEALANT: AT INTERIOR CONCRETE SLAB
<br />EXPANSION JOINTS, PROVIDE TWO -COMPONENT, NON -SAG POLYURETRANE
<br />SEALANT COMPLYING WITH ASIM C920 TYPE M, GRADE NS, CLASS 12.5, USE T,
<br />M, AND 0, WITH MINEMUNI 50 SHORE A HARDNESS (ASTM D2240 ULTIMATE);
<br />"DYNAFLEX" BY PECORA CORPORATION, OR APPROVED SUBSTITUTE. PRIME
<br />SUBSTRATES AS RECOMMENDED, AND INSTALL OVER CLOSED -CELL
<br />POLYURETHANE FOAM BACKER ROD OR BOND BREAKER TAPE AT EXPANSION
<br />JOINTS.
<br />INTERIOR SANITARY SEALANT: AT PLUMBING FIXTURE JOINTS PROVIDE
<br />ONE -PART, NEUTRAL -CURING, MILDEW -RESISTANT SILICONE SEALANT
<br />COMPLYING WITH ASTM C920, CLASS 50; "898" BY PECORA CORPORATION, OR
<br />APPROVED SUBSTITUTE.
<br />INTERIOR FIRE BARRIER SEALANT: AT FIRE -RATED ASSEMBLY JOINTS AND
<br />PENETRATIONS, PROVIDE NON -SLUMP, SINGLE CONTONENT, NEUTRAL CURE
<br />ELASTOMERIC FIRESTOP SEALANT, UL LISTED FOR APPLICATION INDICATED.
<br />PROVIDE MINERAL WOOL INSULATION BACKING AND INSTALL IN COMPLIANCE
<br />WITH UL LISTING.
<br />W LL Co D W (D W
<br />w 0 �_ c� Z _j
<br />0�
<br />< -i >_ W uj 0 -i <2 u
<br />0 = u_<w <Wcn
<br />__j UJ a- m Q� ui
<br />0 u- u �-
<br />2
<br />0 DE =co<v) 0
<br />W<0�-zl=t< Du Q,_ Z
<br />�_ 0� < 0 O�
<br />07Z:Do 3:tozofu_j 0
<br />- Lu r-,l
<br />m-<oo�z D V)�-Eo�
<br />z F_ . T V) 0 Z 0 w Z z — 0 2;
<br />V) �__ 0 �-- 0 0 �-
<br />u- z 0��Quo 0 z
<br />00— 7) Zl--ZUJ MF--
<br />(D -ow z
<br />7)
<br />fj� UJ �� I- U ui
<br />Lu a
<br />0� ::) D - u- z < Q� Q >- [-- E5 �-
<br />< ui �- n I— o uj m — Z 0 (/i
<br />cha-uouO ou__i =<Z
<br />nowo�ujujuzu__jC)ua 00
<br />-
<br />Q� �-- a- �- Q� z < E < w Ir Lu U Z
<br />Lu a- a� w E < - < rr
<br />c/) D� a- ui w < uj E = 3:
<br />Lu Ui u u �_ Fh ui uu) �_ <
<br />= = Of w O� [y_
<br />L_ - E I
<br />I
<br />aj
<br />bf)
<br />10
<br />ct
<br />;-.q
<br />0
<br />_+_�
<br />cin
<br />4_�
<br />r___-4 -c� �.4
<br />v ct
<br />V) 0 4-�
<br />41,
<br />(n P4 CA
<br />,(::$ 'u
<br />;� �� "—..o
<br />0 0 * r_-�
<br />lc�
<br />1� ll-� ,�;-�,
<br />�� ,.I-.-4
<br />+�
<br />E +� JD.�
<br />(D a)
<br />0 ;_-�
<br />U P�, N
<br />;_-�
<br />�>,
<br />rr�
<br />$:)-�
<br />u
<br />N
<br />I I — 11
<br />W 0 a
<br />N �- it
<br />0
<br />-t R
<br />��_. g )_
<br />61 0
<br />w -1 U
<br />—
<br />NJ so v I 9
<br />-j I
<br />I ��w ; I .1 w
<br />,
<br />wk
<br />W�
<br />1% -
<br />�i I
<br />�
<br />-1 00 .� �- a �_
<br />lu r 10 I
<br />,I � N
<br />-
<br />I t u w 4 -1
<br />; N I a
<br />All � � k�4i
<br />1(5 __j
<br />11 I
<br />ISSUE: FOR CONSTRUCTION
<br />I I REV-1SIONS: I I
<br />PROJECT NUMBER
<br />201812
<br />DATE 4-3-19
<br />1 1
<br />SHEET NUMBER
<br />.
<br />A063
<br />
|