Laserfiche WebLink
5 <br />51 <br />3 <br />2 <br />C <br />0 <br />ADJUSTABLE METAL <br />ROD OR LINKAGE <br />TOP REGISTER <br />PLAN VIEW <br />SUPPLY REGISTER TAKE —OFF <br />1/4W 4" MIN. <br />BRANCH DUCT <br />PLAN VIEW <br />BRANCH DUCT TAKE —OFF <br />MAIN SUPPLY <br />DUCT <br />TURNING VANES -- <br />SQUARE ELBOW SHOWN. <br />PROVIDE ROUND ELBOW <br />WHEN SHOWN ON PLANS <br />SUPPLY REGISTER <br />OR BRANCH DUCT <br />PROVIDE VOLUME <br />DAMPER WHEN SHOWN <br />ON PLANS <br />SEE PLAN FOR SPLIT DIMENSION <br />PROVIDE VOLUME <br />DAMPER WHEN SHOWN <br />ON PLANS <br />PLAN VIEW <br />AIR SPLIT TYPE DUCT TAKE —OFF <br />IU SUPPLY DUCT TAKE -OFFS rrts I <br />FIRE BARRIER <br />PARTITION — <br />O.B. DAMPER <br />SUPPLY OR <br />RETURN GRILLE <br />NOTE 5 <br />SLEEVE, NOTE 2 <br />DAMPER COLLAR EXTENSION <br />INTEGRAL PART OF SLEEVE <br />DAMPER, NOTE 1 <br />DUCT CONNECTION, NOTE 4 <br />SLEEVE, NOTE 2 <br />PERIMETER ANGLE, NOTE 3 <br />(NOT FASTENED TO PARTITION) <br />6" MAX <br />NOTES: <br />1. 1-1\2 HOUR U.L. 555 CLASSIFIED CURTAIN TYPE FIRE DAMPER. <br />2. GAAVANIZED STEEL SLEEVE: GAUGE NOT LESS THAN CONNECTING DUCT. FASTEN <br />SLEEVE TO DAMPER FRAME AND TO PERIMETER ANGLES. <br />3. PERIMETER ANGLES: GALVANIZED STEEL, NOT LESS THAN 1-1/2" X 1-1/2" 14 <br />GAUGE, TO PROVIDE 1 INCH MINIMUM OVERLAP OF OPENING ON ALL 4 SIDES. <br />4. BREAKAWAY DUCT CONNECTION: PER SMACNA STANDARDS AND UL LISTING OF <br />DAMPER. <br />5. PROVIDE 1/2" INCH CLEARANCE ON HEIGHT AND WIDTH. FILL OPEN SPACE WITH <br />ROCK WOOL FIRESTOP FIBER. <br />FIRE DAMPER DETAIL Nm <br />20- TRANSITION (MAX) <br />0.25 D (4" MIN. PER SMACNA) <br />RECTANGULAR DUCT <br />VOLUME DAMPER <br />CONICAL FITTING WITH LOCKING <br />TYPE VOLUME DAMPER. <br />FLEX DUCT OR ROUND SHEET METAL DUCT. FLEX <br />DUCT MAX. 8'-0" LONG, USE CLAMP TO ATTACH <br />FLEX DUCTS AND SEAL. SUPPORT DUCT EVERY <br />FOUR FEET FROM STRUCTURE <br />IU DUCT DETAILS NTs I <br />EXTERIOR WALL <br />CONDENSING UNIT EXTERIOR SHEET <br />METAL COVER-------., <br />4" MIN. OR AS == = = SEAL WATERTIGHT <br />OTHERWISE — <br />NOTED <br />Cz <br />GRADE <br />ROUTE REFRIGERANT <br />LINES ABOVE GRADE <br />INSIDE PVC CONDUIT <br />4" THK. CONC. PAD <br />FINISHED <br />WALL <br />FLOOR <br />FOOTING <br />JU5 CONDENSING UNIT DETAIL rrts I <br />FLEXIBLE CONNECTION <br />SUPPLY DUCT----- <br />IN <br />SMOKE DETECTOR <br />AIR HANDLER <br />SUSPEND UNIT FROM STRUCTURE <br />W/ THREADED ROD. PROVIDE <br />SUPPLEMENTAL FRAMING AS <br />REQ'D <br />VIBRATION ISOLATOR <br />FLEXIBLE CONNECTION <br />--- RETURN DUCT <br />I <br />FILTER <br />7CONDENSATE TRAP <br />PROVIDE AUXILIARY DRAIN PAN WITH <br />WITH FLOAT SWITCH INTERLOCKED TO <br />SHUTDOWN UNIT <br />IU AIR HANDLING UNIT DETAIL wrs � <br />"EMOVABLE CLEANOUT <br />LUG <br />INIMUM 2" FOR DRAW <br />HRU UNITS. 0" FOR BLOW <br />HRU UNITS. <br />—1/2 TIMES TOTAL SYSTEM <br />TATIC (MIN. 2" ON BLOW <br />HRU UNITS.) <br />MINIMUM 2" FOR DRAW <br />THRU UNITS <br />IU COOLING COIL DRAIN TRAP DETAIL NTs <br />CONTRACTOR TO ENSURE <br />CONDENSER COIL IS NOT <br />PIERCED. <br />CONDENSING UNIT - <br />G-90 HOT —DIPPED GALVANIZED, <br />SELF —TAPPING, #14 SHEET METAL <br />SCREW. <br />TIE DOWN STRAP, 20 GAUGE <br />(MIN) HOT —DIPPED GALVANIZED <br />SHEET METAL 2" WIDE. PROVIDE <br />PER SCHEDULE BELOW. — <br />3/8 X 1-1/4 HWH TAPCON--,, <br />4 <br />A <br />4" THK. CONC. PAD <br />SCREW SPACING SCHEDULE <br />1 <br />UNITS <br />WITH <br />SIDES LESS THAN 12" PROVIDE 1 SCREW PER SIDE <br />2 <br />UNITS <br />WITH <br />SIDES BETWEEN 12 & 24 PROVIDE 2 SCREWS PER SIDE <br />3 <br />UNITS <br />WITH <br />SIDES BETWEEN 24 & 36 PROVIDE 3 SCREWS PER SIDE <br />4 <br />UNITS WITH SIDES GREATER THAN 36 OR 5 TONS ANCHORAGE <br />BE DESIGNED ACCORDING TO FLORIDA BUILDING CODE. <br />Rw CONDENSING UNIT ANCHORAGE DETAIL NTs <br />FAN <br />4 <br />HANGER SUPPORTS: 1" X 22 <br />GA, DO NOT SUPPORT FROM <br />CEILING. <br />INTEGRAL BACKDRAFT DAMPER <br />VARIABLE SPEED CONTROLLER MARK <br />WITH THE "AS BALANCED POSITION" <br />(DIRECT DRIVE UNITS) <br />DISCONNECT SWITCH: FURNISHED BY <br />MECHANICAL CONTRACTOR OR FAN <br />MANUFACTURER <br />CEILING <br />JUO CEILING FAN DETAIL rma � <br />OUTDOOR UNIT <br />FLITER/DRYER <br />SIGHT GLASS (TX VALVE <br />SYSTEMS ONLY) <br />THERMAL EXPANSION DEVICE (HEAT <br />PUMPS ONLY) <br />SLOPE LIQUID & SUCTION <br />LINES DOWN TOWARDS <br />OUTDOOR UNIT <br />ROOF CURB, RAILS, PATE OR <br />PIPE SLEEVES <br />APPROVED EQUAL <br />PITCH PAN & PITCH <br />SUCTION LINE, INSULATE WITH <br />LIQUID LINE <br />< <br />3/4" ARMAFLEX OR APPROVED <br />EQUAL <br />THERMAL EXPANSION DEVICE <br />(HEAT PUMPS ONLY) <br />HOT -GAS BYPASS LINE <br />(OPTIONAL ON STRAIGHT - <br />DISTRIBUTOR <br />COOL SYSTEMS ONLY) <br />INDOOR COIL <br />SUCTION TRAP <br />NOTE: <br />1. <br />FOR UNITS EQUIPPED WITH UNLOADING TYPE <br />COMPRESSORS USE A DOUBLE -SUCTION RISER <br />SIZED IN ACCORDANCE WITH MANUFACTURERS <br />INSTRUCTIONS. <br />2. <br />ALL REFRIGERANT PIPING ROUTED BENEATH <br />CONCRETE SLABS SHALL BE ENCASED IN PVC <br />PIPE. <br />3. <br />PROVIDE OPERATION AND MAINTENANCE <br />CLEARANCES AROUND ALL EQUIPMENT AS <br />SPECIFIED BY THE MANUFACTURER. <br />4. <br />OUTDOOR UNIT SHALL BE EQUIPPED WITH <br />ISOLATION VALVES. <br />® REFRIGERANT PIPING <br />ISOMETRIC NTs <br />-I Innnor A,- Mro <br />(�L <br />r STRAP TO <br />SAGS & KINKS <br />(PER SMACNA) <br />)UCT: DO NOT <br />INK, INSULATED, <br />5'-0" LONG <br />E AS DIFFUSER <br />:ET METAL <br />-TROUGH HELIX <br />_E DUCT, BAND <br />TAPE <br />VLI LII\V Ulf 1 VJLI\ <br />* FLEXIBLE DUCT SHALL HAVE CONTINUOUS METAL LINER ENCASED BY INSULATING MATERIAL WITH <br />AN OUTER VAPOR JACKET CONFORMING TO UL181 UNLESS THE FLEX DUCT MEETS THE CRITERIA <br />STATED IN 2007 FLORIDA BUILDING CODE —BUILDING SECTION 419.3.11.6. <br />07 CEILING DIFFUSER RUNOUT DETAIL NTs <br />M EM: S550 Re eF� <br />9 4Tao700 Paf 33609 <br />8Suite 1128et <br />MFOUP <br />Mark E. Awmiller, PE 111113 <br />COA # 8304 <br />Project # 2013577 <br />THE COMMONS <br />ON PRETTY POND <br />38130 Pretty Pond Road <br />Zephyrhills, FL 33540 <br />10/15/13 PERMIT SET <br />Mark Date Description <br />Issue/Revision <br />Revision <br />Project ID <br />13D16 <br />CAD File Name <br />- <br />Drawn By <br />DKS <br />Reviewed By <br />MEA <br />Plot Date: <br />00/00/00 <br />Record Date: <br />00/00/00 <br />Sheet Title <br />MECHANICAL DETAILS <br />Drawing No. <br />SCALE: NTS <br />M-5.1 <br />5 <br />9. <br />3 <br />01 <br />