Laserfiche WebLink
I <br />O <br />3 <br />2 1 1 <br />I <br />IN <br />: <br />F <br />AHU HP SPLIT SYSTEM HEAT PUMP SCHEDULE <br />AIR HANDLER <br />CONDENSING <br />UNIT <br />MARK <br />MANUFACTURER <br />MODEL # <br />REMARKS <br />EAT <br />TOTAL <br />SENSIBLE <br />SUPPLY FAN <br />OUTDOOR <br />POWER <br />DB/WB <br />COOLING (MBH) <br />COOLING (MBH) <br />TEMPERATURE <br />SEER/COP <br />SUPPLY CFM <br />OSA CFM <br />ESP <br />HP <br />VOLTS <br />MCA <br />MOCP <br />VOLTS <br />AHU-1 <br />DAIKIN <br />FDXS09LVJU <br />75.0/60.1 <br />4.9 <br />4.6 <br />225 <br />0 <br />0.12 <br />- <br />208/1 <br />1 <br />15 <br />208/1 <br />1-5 <br />HP-1 <br />DAIKIN <br />RXS09LVJU <br />957 <br />15.1 <br />8 <br />15 <br />208/1 <br />AHU-2 <br />DAIKIN <br />FDXS09LVJU <br />75.0/60.1 <br />4.9 <br />4.6 <br />225 <br />0 <br />0.12 <br />- <br />208/1 <br />1 <br />15 <br />208/1 <br />1-5 <br />HP-2 <br />DAIKIN <br />RXS09LVJU <br />957 <br />15.1 <br />8 <br />15 <br />208/1 <br />AHU-3 <br />DAIKIN <br />FDXS09LVJU <br />75.0/60.2 <br />4.4 <br />4.1 <br />225 <br />0 <br />0.12 <br />- <br />208/1 <br />1 <br />15 <br />208/1 <br />1-5 <br />HP-3 <br />DAIKIN <br />RXS09LVJU <br />I <br />957 <br />15.1 <br />8 <br />15 <br />208/1 <br />AHU-4 <br />DAIKIN <br />FDXS09LVJU <br />75.0/59.8 <br />6.7 <br />6.4 <br />225 <br />0 <br />0.12 <br />- <br />208/1 <br />1 <br />15 <br />208/1 <br />1-5 <br />HP-4 <br />DAIKIN <br />RXS09LVJU <br />1 <br />957 <br />15.1 <br />8 <br />15 <br />208/1 <br />AHU-5 <br />DAIKIN <br />FDXS09LVJU <br />75.0/59.7 <br />7.4 <br />7.2 <br />225 <br />0 <br />0.12 <br />- <br />208/1 <br />1 <br />15 <br />208/1 <br />1-5 <br />HP-5 <br />DAIKIN <br />RXS09LVJU <br />957 <br />15.1 <br />8 <br />15 <br />208/1 <br />AHU-6 <br />DAIKIN <br />FDXS12LVJU <br />75.0/59.5 <br />9.1 <br />8.8 <br />225 <br />0 <br />0.12 <br />- <br />208/1 <br />1 <br />15 <br />208/1 <br />1-5 <br />HP-6 <br />DAIKIN <br />RXS12LVJU <br />1 <br />957 <br />15.1 <br />8 <br />15 <br />208/1 <br />AHU-7 <br />DAIKIN <br />FDXS12LVJU <br />75.0/59.8 <br />7.2 <br />6.9 <br />225 <br />0 <br />0.12 <br />- <br />208/1 <br />1 <br />15 <br />208/1 <br />1-5 <br />HP-7 <br />DAIKIN <br />RXS12LVJU <br />957 <br />15.1 <br />8 <br />15 <br />208/1 <br />AHU-8 <br />DAIKIN <br />FBQ24PVJU <br />77.1/64.7 <br />20.2 <br />14.2 <br />660 <br />85 <br />0.4 <br />- <br />208/1 <br />1.5 <br />15 <br />208/1 <br />1-5 <br />HP-8 <br />DAIKIN <br />RZQ24PVJU9 <br />957 <br />16.5 <br />16.5 <br />20 <br />208/1 <br />AHU-9 <br />DAIKIN <br />FBQ24PVJU <br />78.1/65.5 <br />20.8 <br />13.5 <br />660 <br />100 <br />0.4 <br />- <br />208/1 <br />1.5 <br />15 <br />208/1 <br />1-5 <br />HP-9 <br />DAIKIN <br />RZQ24PVJU9 <br />I <br />957 <br />16.5 <br />16.5 <br />20 <br />208/1 <br />AHU-10 <br />DAIKIN <br />FDXS12LVJU <br />75.0/56.8 <br />3.3 <br />3.3 <br />150 <br />0 <br />0.12 <br />- <br />208/1 <br />0 <br />15 <br />208/1 <br />1-5 <br />HP-10 <br />DAIKIN <br />RXS12LVJU <br />I <br />1 <br />957 <br />15.1 <br />8 <br />15 <br />208/1 <br />AHU-(E) <br />DAIKIN <br />FDXS12LVJU <br />75.0/56.8 <br />10 <br />10 <br />300 <br />0 <br />.12 <br />- <br />208/1 <br />1 <br />15 <br />208/1 <br />1,2,4,6 <br />95'F <br />- <br />* DESIGN CONDITIONS: SUMMER 957/777; WINTER LOW-177 HIGH-477 ® 657 EVAPORATOR ENTERING <br />**MECHANICAL CONTRACTOR AND VENDOR ARE RESPONSIBLE FOR APPROPRIATE CONTROLS COMPONENTS AND INSTALLATION OF CONTROLS SYSTEM. INSTALL PER MANUFACTURER'S RECOMMENDATIONS FOR <br />PROPER OPERATION OF SYSTEMS. CERTIFIED REPRESENTATIVE SHALL INSTALL AND STARTUP. <br />NOTES <br />1. PROVIDE WITH 7-DAY, 24 HOUR PROGRAMMABLE THERMOSTAT WITH THE APPROPRIATE NUMBER OF COOLING AND HEATING STAGES (SUPPLIED BY MANUFACTURER). <br />2. PROVIDE FILTER BOX WITH FILTER, AND CONDENSATE PUMP AS REQUIRED. <br />3. PROVIDE ALL SYSTEMS WITH EQUIPMENT REQUIRED FOR LONG LINE APPLICATIONS, AS REQUIRED BY MANUFACTURER'S RECOMMENDATIONS. <br />4. PROVIDE ALL APPROPRIATE ACCESSORIES FOR SPECIFIED OPERATION. <br />5. ALL DUCTABLE AHU'S SHALL BE LOW STATIC. <br />6. EXISTING EQUIPMENT SHALL BE CLEANED INSPECTED AND REFURBISHED TO LIKE NEW CONDITION PRIOR TO INSTALLATION. CONNECT TO EXISTING VRF SYSTEM. <br />GRILLE AND DIFFUSER SCHEDULE <br />*MARK <br />MANUFACTURER <br />MODEL # <br />DESCRIPTION <br />FRAME <br />FINISH <br />MATERIAL <br />DAMPER <br />REMARKS <br />CD-1 <br />PRICE <br />620DAL <br />DOUBLEDEFLECTION; ALUMINUM; <br />SURFACE <br />WHITE <br />ALUMINUM <br />OBD <br />1,3,4 <br />SPACING <br />CD-2 <br />PRICE <br />APDSPE <br />24X24 LAY -IN DIFFUSER FLUSH <br />FACE; 4 WAY THROW <br />LAY -IN <br />WHITE <br />ALUMINUM <br />- <br />1,2 <br />CG-1 <br />PRICE <br />635DAL <br />CEILING GRILLE; I" BLADE SPACING; <br />SURFACE <br />WHITE <br />ALUMINUM <br />OBD <br />1,3,4 <br />ALUMINUM DAMPER <br />CG-2 <br />PRICE <br />635DAL <br />24X24 LAY -IN GRILLE; J" BLADE <br />LAY -IN <br />WHITE <br />ALUMINUM <br />OBD <br />1,2 <br />SPACING; ALUMINUM DAMPER <br />SD-1 <br />PRICE <br />620DAL <br />DOUBLE DEFLECTION; ALUMINUM; <br />SURFACE <br />WHITE <br />ALUMINUM <br />OBD <br />1,3,4 <br />SPACING <br />SG-1 <br />PRICE <br />630DAL <br />HORIZONTAL BLADES; ALUMINUM; <br />SURFACE <br />WHITE <br />ALUMINUM <br />OBD <br />1,3,4 <br />SPACING <br />NOTES: <br />1. PAINT PER ARCHITECT. <br />2. NECK SIZE AS LISTED. PROVIDE FULL FACE SQUARE TO ROUND INSULATED BOOT. <br />3. SIZE AS INDICATED ON PLANS. <br />4. PAINT INSIDE OF DIFFUSER/GRILLE FLAT BLACK. <br />(-) EXHAUST FAN SCHEDULE <br />MARK <br />MANUFACTURER <br />MODEL <br />TYPE <br />CFM <br />E.S.P. <br />HP (WATT) <br />VOLTS/0 <br />BACK DRAFTPER <br />DRIVE <br />SONES <br />REMARKS <br />EF-1 <br />COOK <br />GC-120 <br />CEILING <br />50 <br />0.125 <br />(25) <br />115/1 <br />YES <br />DIRECT <br />1.1 <br />1,2 <br />EF-2 <br />COOK <br />GC-140 <br />CEILING <br />75 <br />0.125 <br />(70) <br />115/1 <br />YES <br />DIRECT <br />1.1 <br />1,2 <br />EF-3 <br />COOK <br />GC-160 <br />CEILING <br />100 <br />0.125 <br />(113) <br />115/1 <br />YES <br />DIRECT <br />1.1 <br />1,3 <br />EF-4 <br />COOK <br />GC-160 <br />CEILING <br />100 <br />0.125 <br />(113) <br />115/1 <br />YES <br />DIRECT <br />1.1 <br />1,4 <br />NOTES: <br />1. PROVIDE WITH BACK DRAFT DAMPER AND SPEED CONTROLLER. <br />2. PROVIDE INDEPENDENT SWITCH. <br />3. INTERLOCK WITH LIGHTS. <br />4. CONNECT TO OPERATE CONTINUOUSLY. <br />oAL LOUVER SCHEDULE <br />MARK <br />MANUFACTURER <br />MODEL # <br />TYPE <br />WXH <br />FREE ^ <br />AREA (FT 2) <br />DRAINABLE <br />REMARKS <br />OAL-1 <br />RUSKIN <br />ELF6375DXD <br />INTAKE <br />12X12 <br />0.31 <br />YES <br />1,2 <br />NOTES: <br />1. PROVIDE WITH KYNAR FINISH. COORDINATE WITH ARCHITECT ON FINAL PAINT COLOR <br />2. PROVIDE WITH BIRD SCREEN <br />SUPPLY FLEX RUNOUT SCHEDULE <br />FLEX DUCT SIZE <br />10"0 <br />250-330 CFM <br />8"0 <br />105-245 CFM <br />6010 <br />0 - 100 CFM <br />MECHANICAL LEGEND <br />® <br />SUPPLY <br />RETURN OR TRANSFER <br />® <br />EXHAUST <br />eEQUIPMENT <br />MARK <br />MANUAL BALANCING DAMPER <br />Q <br />TEMPERATURE SENSOR (ADJ. DIGITAL) <br />TAP W/DAMPER <br />SINGLE LINE DUCT <br />�/ <br />FLEX DUCT <br />�- <br />FIRE DAMPER <br />ODRAWING <br />NOTE <br />•� <br />PIPE DOWN <br />c� <br />PIPE UP <br />-CD- <br />CONDENSATE DRAIN <br />(E) <br />EXISTING <br />EQUIPMENT TO BE REMOVED <br />MECHANICAL NOTES: <br />IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. <br />SUBMITTALS SHALL MEET SCHEDULED DESIGN CHARACTERISTICS. THIS INCLUDES BUT NOT LIMITED TO CFMS, EAT(DB/WB), ESP, CAPACITIES, VOLTAGES/PHASES, MCA/MOCP, SONES, <br />ETC... <br />ALL CONSTRUCTION WORK SHALL ALSO MEET THE FOLLOWING BUILDING CODE REQUIREMENTS: <br />* FLORIDA BUILDING CODE (FBC) 2010 <br />* FBC ENERGY CONSERVATION 2010 <br />* FBC MECHANICAL CODE 2010 <br />* FBC PLUMBING CODE 2010 <br />ALL WALL MOUNTED THERMOSTATS AND/OR TEMPERATURE SENSORS SHALL BE INSTALLED AT AN ELEVATION OF 48" ABOVE FINISHED FLOOR TO THE TOP UNLESS OTHERWISE NOTED ON <br />DRAWINGS. LOCATION OF THE WALL MOUNTED THERMOSTAT SHALL BE COORDINATED WITH OTHER TRADES FOR A NEAT APPEARANCE. FINAL LOCATION OF THERMOSTAT SHALL BE <br />SUBJECT TO THE APPROVAL OF THE ENGINEER OR REPRESENTATIVE IN THE FIELD. <br />ALL SUPPLY AIR DIFFUSERS SHALL BE 4-WAY THROW UNLESS OTHERWISE NOTED. CONTRACTOR SHALL PAINT INSIDE EACH RETURN GRILLE'S PLENUM AND DUCT CONNECTION FLAT <br />BLACK TO CONCEAL CONNECTION. COORDINATE AIR DEVICE LOCATIONS WITH LIGHTING FIXTURES AND FIRE SPRINKLER HEADS. PRIOR TO INSTALLATION, THE CONTRACTOR IS TO REFER <br />TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR ACTUAL FINAL LOCATIONS OF AIR DEVICES. <br />DIFFUSERS/GRILLES SHALL NEVER BE INSTALLED ON SURFACE OF ACOUSTICAL LAY -IN TILE. ALL DIFFUSERS/GRILLES IN LAY -IN CEILINGS SHALL BE LAY -IN PANEL MOUNT. REFER TO <br />SCHEDULE. GYPSUM BOARD SURFACE MOUNT DIFFUSERS SHALL NOT BE BEVEL MOUNT. <br />CONTRACTOR SHALL COORDINATE DIFFUSER/GRILLE LOCATIONS WITH STRUCTURE IN EXPOSED SITUATIONS IN ORDER TO ENSURE AIR IS NOT DIRECTLY SUPPLIED OR RETURNED OVER <br />STRUCTURE OR OTHER TRADE COMPONENTS SUCH AS FIRE SPRINKLER PIPING, PLUMBING PIPING, ETC... CAUSING DUST ACCUMULATION. DUCTWORK ALONG WITH DIFFUSER/GRILLE <br />LOCATIONS SHALL BE INSTALLED SYMMETRICALLY WITH ANY ADJACENT DUCTWORK/GRILLES. CENTER DIFFUSERS/GRILLES BETWEEN STRUCTURAL MEMBERS WHERE DUCTWORK AND <br />STRUCTURAL MEMBERS ARE EXPOSED. CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL INSTALLATION APPEARANCE AND SHALL MAKE APPROPRIATE CHANGES WHERE DIRECTED BY <br />ARCH./ENGINEER AT THEIR OWN EXPENSE WHERE ITEMS ARE NOT INSTALLED PER ABOVE STANDARDS. <br />CONTRACTOR SHALL PROVIDE A COPY OF THE TEST AND BALANCE REPORT BY AN AABC OR NEBB CERTIFIED AGENCY. THIS REPORT MUST BE REVIEWED AND APPROVED BY THE <br />ENGINEER PRIOR TO THE FINAL INSPECTION. THE CONTRACTOR MUST ALSO PROVIDE ALL REPORTS REQUIRED BY THE SPECIFICATION. OUTDOOR TEMPERATURE (DB); OUTSIDE AIR <br />(DB/WB & CFM); SUPPLY AIR AT UNIT DISCHARGE (DB/WB & CFM); RETURN AIR €MIXEDI (DB/WB & CFM); LEAVING COIL (DB/WB); DIFFUSER/GRILLE (DB/WB); EQUIPMENT (EWT/LWT); <br />EQUIPMENT (EAT/LAT); EQUIPMENT (GPM); EQUIPMENT (PRESSURES). OUTSIDE AIR CFM SHALL BE MEASURED DIRECTLY AND NOT CALCULATED FROM THE DIFFERENCE BETWEEN SUPPLY <br />AIR CFM AND RETURN AIR CFM. <br />ALL AIR -HANDLING UNITS SHALL BE MECHANICALLY ATTACHED TO OTHER AIR DISTRIBUTION SYSTEM COMPONENTS. AIR -HANDLING UNITS LOCATED OUT -SIDE THE CONDITIONED SPACE <br />SHALL BE SEALED USING APPROVED CLOSURE SYSTEMS CONFORMING TO THE APPROVED CLOSURE AND MECHANICAL APPLICATION REQUIREMENTS OF FLORIDA BUILDING CODE. <br />ALL DUCTWORK MUST BE INSTALLED 6" AWAY FROM ANY FIRE RATED WALL TO FACILITATE INSPECTION. <br />THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL TRADES INSTALLATION SCHEDULES. FIXED WORK SUCH AS DUCTWORK AND PLUMBING SHALL BE INSTALLED PRIOR TO ANY TRADE <br />WORK THAT CAN BE EASILY RELOCATED OR OFFSET SUCH AS ELECTRICAL CONDUITS, SMALL WATER LINES, ETC. IDEALLY DUCTWORK SHALL BE INSTALLED FIRST. <br />PENETRATIONS THROUGH SMOKE OR FIRE -RATED ASSEMBLIES: PENETRATIONS FOR PIPES, CONDUITS OR OTHER PURPOSES THROUGH ASSEMBLIES (FLOORS, ROOF, WALLS, PARTITIONS, <br />ETC.) WITH A REQUIRED FIRE RESISTANCE RATING SHALL BE SEALED TO THE PENETRATING MEMBER IN AN APPROVED MANNER WHICH MAINTAINS THE REQUIRED FIRE RESISTANCE <br />RATING OF THE ASSEMBLY AS FOLLOWS: <br />WHERE HOLES FOR PENETRATIONS ARE FORMED CIRCULAR OR CORE -BORED, THE PENETRATION SHALL BE PROTECTED WITH FIRE -SEAL BRAND SMOKE AND FIRE STOP FITTINGS <br />MFG. BY 0-Z GEDLEY, LINK SEAL BRAND BY THUNDER LINE OR AN EQUAL APPROVED BY ENGINEER. <br />WHERE HOLES FOR PENETRATIONS ARE IRREGULAR (NON -CIRCULAR) IN SHAPE, THE PENETRATION SHALL BE PROTECTED WITH DOW CORNING 3-6548, SILICONE RTV FOAM, 3M <br />FIRE BARRIER PENETRATION SEAL SYSTEM OR AN EQUAL APPROVED BY THE ENGINEER. <br />INTENT OF THESE NOTES AND MECHANICAL NOTES ON DRAWINGS IS TO CLARIFY THE SCOPE OF WORK AND ALERT CONTRACTOR OF EXISTING CONDITIONS. THE CONTRACTOR IS TO <br />VISIT SITE AND VERIFY ALL CLEARANCES BEFORE FABRICATION OF DUCTWORK AND PROVIDE ADDITIONAL OFFSET AND/OR CHANGES IN DUCT SIZES TO MEET FIELD CONDITIONS AND <br />COORDINATE WITH ELECTRICAL, PLUMBING AND FIRE PROTECTION SUBCONTRACTORS BEFORE ANY CONSTRUCTION WORK. <br />FLEXIBLE AND RIGID ROUND DUCT TAKE -OFFS FOR DIFFUSERS SHALL BE THE SAME SIZE AS DIFFUSER NECK. MAXIMUM FLEXIBLE DUCT LENGTH SHALL BE 10'-0". <br />UNLESS OTHERWISE NOTED, INSTALL DUCTWORK AS HIGH AS POSSIBLE, TIGHT TO BOTTOM OF STRUCTURE. COORDINATE DUCT ELEVATION WITH RAIN LEADERS, WATER PIPING, SANITARY <br />DRAINS AND MAJOR ELECTRICAL CONDUITS. <br />CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND/SUPPORT MECHANICAL EQUIPMENT AND MATERIALS. <br />CONTRACTOR SHALL INSTALL MOTORIZED OUTSIDE AIR DAMPERS FOR ALL AIR HANDLING EQUIPMENT. AIR HANDLING UNITS SHALL HAVE AN EQUIVALENT OR BETTER OF RUSKIN "CD504" <br />DAMPER, WHICH SHALL MODULATED PER 24V ACTUATOR MECHANICALLY WIRED. ALL DAMPERS SHALL SHUT UPON UNIT SHUTDOWN. <br />PROVIDE A TRAP IN ALL CONDENSATE PIPING LOCATED AT THE AIR HANDLING EQUIPMENT. INSULATE ALL CONDENSATE LINES WITH 1 /2" THICK CLOSED CELL FOAM INSULATION. ALL <br />PIPING EXPOSED TO EXTERNAL ELEMENTS SHALL BE JACKETED WITH UV STABILIZED PVC OR ALUMINUM SHEETING. <br />PROVIDE A 4" HIGH CONCRETE HOUSEKEEPING PAD UNDER ALL MECHANICAL EQUIPMENT, UNLESS OTHERWISE NOTED. PADS SHALL BE 4" LARGER THAN THE EQUIPMENT ON ALL SIDES. <br />UNLESS OTHERWISE NOTED, ALL UNDERGROUND PIPING SHALL HAVE A MINIMUM OF 3'-0" OF COVER. <br />IT IS THE RESPONSIBILITY OF THE MECHANICAL INSTALLER TO PATCH AND REPAIR ANY DUCT OPENINGS WHICH RESULT FROM THE RELOCATION OR ELIMINATION OF ANY EXISTING AIR <br />DEVICES. THE PATCH IS TO BE OF A SIMILAR MATERIAL TO THE REPAIRED DUCT AND TO BE SEALED IN ACCORDANCE WITH SMACNA STANDARDS. <br />AIR HANDLING EQUIPMENT WARRANTIES SHALL BE EQUAL TO OR EXCEED WARRANTY OF SCHEDULED EQUIPMENT. UNLESS OTHERWISE NOTED. <br />PROVIDE ADDITIONAL DUCTWORK AND PIPING SUPPORTS ON BOTH SIDES AND WITHIN 18" OF FIRE RATED WALL. DUCTWORK OR PIPING SHALL NOT BE SUPPORTED FROM ANY FIRE <br />RATED WALL. <br />FOR DUCTWORK PENETRATING ONE HOUR FIRE RATED WALL, THE ENTIRE DUCT SYSTEM, TO BE CONSTRUCTED PER SMACNA STANDARDS WITH A MINIMUM OF 26 GA. STEEL DUCT AND <br />SHALL CONTINUE IN THE HORIZONTAL DIRECTION WITHOUT ANY GRILLE OR OPENING FOR NOT LESS THAN 5'-0" FROM THE WALL AND DUCT SHALL NOT EXCEED SQUARE INCH <br />REQUIREMENTS OF LOCAL CODE, OTHERWISE A FIRE DAMPER SHALL BE PROVIDED. <br />DOUBLE WALLED TURNING VANES SHALL BE PROVIDED IN ALL RECTANGULAR SUPPLY DUCT ELBOWS WITH ANGLES FROM 45 DEGREES TO 90 DEGREES PER FIG. 2-5 OF THE SMACNA <br />MANUAL. <br />DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS (FREE AREA). <br />CONTRACTOR SHALL COORDINATE ALL INTAKE/EXHAUST LOCATIONS TO INSURE AT LEAST A 10' DISTANCE BETWEEN ANY INTAKES AND VENTILATION EXHAUSTS, PLUMBING VENTS, <br />RELIEF, ETC... <br />ALL HVAC EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS UNLESS INDICATED OTHERWISE. <br />MECHANICAL CONTRACTOR SHALL SIZE AND INSTALL REFRIGERANT PIPING PER MANUFACTURER'S RECOMMENDATIONS. REFRIGERANT PIPING SHALL BE TYPE "L" COPPER WITH BRAZED <br />JOINTS. APPLY -Y4" CLOSED CELL INSULATION ON COMPRESSOR SUCTION LINE. ALL PIPING EXPOSED TO EXTERNAL ELEMENTS SHALL BE JACKETED WITH UV STABILIZED PVC OR <br />ALUMINUM SHEETING. PRE -CHARGED LINES AND SOLDER ON SHORT 90'S ARE NOT ACCEPTABLE. CONTRACTOR SHALL USE SWEEPING 90'S AT EVERY BEND WITH EXCEPTION OF <br />EQUIPMENT CONNECTIONS. <br />CONTRACTOR SHALL PROVIDE A PERMANENT/PROFESSIONAL LABEL FOR EACH PIECE OF EQUIPMENT, ASSOCIATED THERMOSTAT(S) AND/OR SENSOR(S). <br />EQUIPMENT LOCATION IDENTIFICATIONS AT CEILINGS: WHERE VALVES, EQUIPMENT SUCH AS VAV BOXES, FANS, ETC... CIRCUIT BREAKERS OR OTHER ITEMS SUBJECT TO ROUTINE SERVICE <br />ARE MOUNTED IN A CONCEALED AREA ABOVE A CEILING, THE CEILING MUST BE MARKED WITH A LABEL UNDER THE SERVICED DEVICE. THE LABEL SHALL CARRY APPROPRIATE <br />IDENTIFICATION TAG. <br />DUCTWORK, DIFFUSERS, REGISTERS, GRILLES, AND OTHER ITEMS OF THE AIR HANDLING SYSTEM SHALL NOT BE SUPPORTED BY THE CEILING OR CEILING SUSPENSION SYSTEM. <br />METAL DUCTWORK SHALL BE CONNECTED TO AIR HANDLING EQUIPMENT WITH FLEXIBLE DUCT CONNECTORS EQUAL TO DURO DYNE "SUPER METAL-FAB" WITH EXCELON FABRIC; "GRIP <br />LOC" SEAM; 24 GAUGE METAL TABS. INSULATION SHALL BE INSTALLED OVER METAL TABS AS TO NOT CAUSE FRICTION ON FABRIC. <br />LOW PRESSURE SUPPLY, RETURN, AND TRANSFER DUCTWORK SHALL BE EXTERNALLY INSULATED SHEET METAL CONSTRUCTION IN ACCORDANCE WITH LATEST SMACNA STANDARDS <br />UNLESS OTHERWISE NOTED. DUCT INSULATION TO BE 2.0" THICK FOIL BACK WRAP, K=0.25 BTUH-IN./SF. HR- 1.50#/CF AS MANUFACTURED BY JOHNS MANVILLE. JOINTS TO BE <br />STAPLED AND TAPED WITH PRESSURE SENSITIVE TAPE (PER FMC 603) AS MANUFACTURED BY COMPAC INDUSTRIES MODEL #120 (FLAME SPREAD = 5, SMOKE DEVELOPED = 10) OTHER <br />ACCEPTABLE MANUFACTURERS ARE OWENS CORNING AND KNAUF. IN LIEU OF SHEET METAL DUCTWORK, DUCT BOARD MAY BE USED. CONTRACTOR SHALL (BID AS DEDUCTIVE <br />ALTERNATE). 1.5" TRICK DUCT BOARD (EQUAL TO JOHNS MANVILLE BONDED WITH THERMO SETTING RESIN ON AIR STREAM SIDE WITH AN ANTI -MICROBIAL COATING) AND CONFORM <br />WITH UL STANDARDS FOR SAFETY AIR DUCT, NO. 181, 1967 ESTABLISHED FOR CLASS 1 AIR DUCTS. FACING SHALL BE FSK ALUMINUM FOIL. CONSTRUCTION SHALL COMPLY WITH <br />RECOMMENDATIONS AND DETAILS IN SMACNA AND NAIMA FIBROUS GLASS DUCT CONSTRUCTION STANDARDS, LATEST REVISION AND MANUFACTURER'S RECOMMENDATIONS. ALL JOINTS <br />SHALL BE SECURELY TAPED WITH FASSON 0810 OR APPROVED EQUAL PRESSURE SENSITIVE TAPE. METAL TO FIBERGLASS CONNECTIONS TO BE MADE USING 3" WIDE GLASS FABRIC <br />TAPE WITH FOSTER 30/35 MASTIC OR EQUAL. SUPPORT DUCTS WITH 1X2X1 22 GAUGE MINIMUM CHANNELS AND STRAP OR 12-GAUGE WIRE FROM BUILDING CONSTRUCTION. <br />SUSPEND FROM JOISTS WITH BEAM CLAMPS. PROVIDE HOT DIPPED STEEL FASTENERS, ANCHORS, RODS, STRAPS, TRIM AND ANGLES FOR SUPPORT OF DUCTWORK. DUCT SIZES ON <br />CONSTRUCTION DOCUMENTS ARE INTERNAL FREE -AREA DIMENSIONS. <br />ALL EXHAUST DUCT WORK SHALL BE NON -INSULATED SHEET METAL UNLESS OTHER WISE NOTED. <br />FLEXIBLE DUCT SHALL HAVE CONTINUOUS TEAR RESISTANT LINER ENCASED BY INSULATING MATERIAL WITH AN OUTER VAPOR JACKET CONFORMING TO UL181 UNLESS THE FLEX DUCT <br />MEETS THE CRITERIA STATED IN 2010 FLORIDA BUILDING CODE -BUILDING SECTION 419.3.6.4. <br />COORDINATE AIR DEVICE LOCATIONS WITH LIGHTING FIXTURES AND FIRE SPRINKLER HEADS. <br />CONTRACTOR SHALL SUPPLY PIPE SUPPORTS 4'-0" ON CENTERS FOR REFRIGERANT LINES AND CONDENSATE LINES. SUPPORTS SHALL BE PER DETAILS. <br />CONTRACTOR SHALL REFER TO ALL DETAILS FOR PROPER GUIDANCE. <br />MES,112.90.4700 <br />PareFL 33609 <br />Mark E. Awmiller, PE 111111 <br />COA # 6304 <br />Project # 2013577 <br />THE COMMONS <br />ON PRETTY POND <br />38130 Pretty Pond Road <br />Zephyrhills, FL 33540 <br />- 10/15/13 PERMIT SET <br />Mark I Date <br />Description <br />Issue/Revision <br />Revision <br />Project ID <br />13D16 <br />CAD File Name <br />- <br />Drawn By <br />DKS <br />Reviewed By <br />MEA <br />Plot Date: <br />00/00/00 <br />Record Date: <br />00/00/00 <br />Sheet Title <br />Drawing No. <br />SCHEDULES <br />SCALE: NTS <br />M-6.0 <br />5 <br />M <br />3 <br />2 I 1 <br />