My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39752 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39752 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 2:49:42 PM
Creation date
2/19/2025 2:38:33 PM
Metadata
Fields
Template:
Building Plans
Street #
39752
Location
Harvest Creek Ln
Contractor
Lennar Homes
Building Plans - Permit #
1456
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />VENT OR 2ND FLOOR <br />PLAN <br />1/2" MINIMUM CEMENT FINISH <br />TYPICAL C.M.U. WALL <br />2x6 / 2x8 WALL BEYOND <br />(2) 2x HEADER TO SIT <br />FLUSH TO THE OUTSIDE <br />STANDARD 3" DIA. TEE <br />3/4"FURRING STRIPS <br />SEE PLAN FOR HEADER <br />SEE PLAN FOR SIZE <br />THREADED 3" DIA. EXTENSION <br />1/2" GYPSUM BOARD <br />CONNECTION <br />SCREW OFF CAP (3" DIA.) <br />W/ DRYWALL SCREWS <br />2x DEAD WOOD @MID <br />FOR CLEAN -OUT <br />@ 8" O.C. OR 4d <br />121±1 <br />POINT w/ (3) 12d <br />DRYWALL NAILS <br />TONEAILS SPACED <br />MIN. EXTENSION FROM <br />DOUBLE 2x TOP <br />EVENLY <br />EXTERIOR FACE OF BLOCK <br />WALL IS 1 1/2" MAXIMUM <br />PLATE INTERIOR <br />HEADER FLUSH TO OUTSIDE OPTION EXTENSION FROM EXTERIOR WALL <br />FACE OF BLOCK WALL IS 2 1/4" <br />2x BLOCKING @ EACH END W/ 10d @ <br />4" O.C. FROM EACH HEADER FACE <br />TO BLOCKING <br />(2) 2x HEADER <br />PER PLAN <br />2x BOTTOM PLATE W/ (1)10d @ 8" <br />VARIES O.C. TO EACH HEADER FACE <br />2 x 6 MIN. FRAME <br />WALL HEADER DETAIL 1 <br />SCALE: N.T.S. S4 <br />12 <br />SEE TYPICAL WALL SECTION <br />(TYp) SEE ELEV. <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2x4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2)12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />SIMPSON SP2 w/ (12)1Old <br />(3)10d TOENAILS T&B <br />NAILS AT EACH STUD <br />AS REQ'D <br />2x BLOCKING @ MID <br />POINT EVERY OTHER <br />171-1 STUD W/ (3)1Old NAILS <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />PLATE W/ (2)16d TO <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" OIC <br />EDGES & 8" O/C FIELD <br />=== <br />SIMPSON SP1 w/ (10) 10d <br />NAILS AT EACH STUD <br />BLOCKING (TYP.) <br />2x P.T. PLATE <br />ROOFTRUSS <br />5/8" x 10" "J" BOLT @ 24" O/C MAX <br />W/ 8" EMBEDMENT <br />UPLIFT CONNECTOR (SEE SCHEDULE) <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />MOISTURE BARRIER <br />1 #5 VERT. IN CONC. FILLED CELL W/ <br />STD. 90" HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL <br />DETAIL <br />rF� <br />TO DRAIN <br />EXTERIOR <br />WALL CLEAN -OUT WALL <br />A <br />SCALE: N.T.S. S4 <br />1ST COURSE 2ND COURSE 3RD COURSE <br />REFER TO WINDOW PRODUCT APPROVAL MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COURSE MUST BE BONDED TO THE <br />SHEETS FOR INSTALLATION INFORMATION BY COURSE BELOW. EVERY THIRD (3RD) COURSE THE 11" DOOR JAMB WALL IS TO BE <br />MANUFACTURER. WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. <br />TYPICAL SECTION THRU WINDOW B MASONRY LAYOUT D <br />S4 SCALE: N.T.S. S4 <br />7 5/8" 8" 7 5/8" 8" 7 5/8" 8" <br />KNOCK -OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT J <br />d <br />d d <br />d d <br />g" STD. 90'HOOK 8" <br />LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS <br />GREATER THAN 6'-0" WIDE (U.N.O. ON <br />PLAN) <br />OPENING <br />FILLED CELL W/ (1) #5 VERTICAL <br />SEE FDN. PLAN FOR LOCATION <br />NOTES: <br />1O FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />Q VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY. <br />O3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />® OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />TYPICAL FILLED LINTEL ASSEMBLY <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />S4 <br />WIDTH OF OPENING VARIES Orr <br />FORM CONCRETE INSET TO <br />CREATE A SOLID BASE FOR <br />1/2"X9 1/2" PLYWOOD BLOCK WALL ABOVE. <br />SCRAP MATERIAL <br />J <br />LLI <br />0 <br />FORM CREATES CONCRETE RECESS TO <br />2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />MOUNTING BASE NOT SHOWN <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />FOR CLARITY SEE DETAIL <br />MOUNTING BASE SHOWN <br />IN POSITION <br />K/S4 <br />GARAGE ENTRY FORM DETAIL <br />SEAT FOR BLOCK IS POURED <br />2x6 MOUNTING BASE <br />SCALE: N.T.S. <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />C.M.U. <br />GARAGE DOOR TRACK MOUNTING BRACKET <br />TROWEL FINISH SEE <br />�8x8x16 <br />GENERALNOTES <br />SLOPE FORWARD <br />GARAGE DOOR ROLLER GARAGE DOOR TRACK <br />FOR DRAINAGE <br />CONNECTION ASSEMBLY <br />` GARAGE FLOOR <br />j% <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. <br />d d a <br />SEE PLAN FOR FOOTING <br />POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B E <br />DIMENSIONS <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />P <br />SHED FORWARD THIS DRAWING. <br />SCALE: N.T.S. <br />S4 <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />N <br />2x CRIPPLES @ --� <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />SIMPSON SP4 w/ (6) <br />10d x 1 1 /2" AT EA <br />STUD (USE SP6 FOR <br />2x6 WALL, USE SP8 <br />FOR 2X8 WALL) <br />10d NAILS @ 8" <br />O/C TYP. <br />DOUBLE 2x <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />SOLID AREAS ARE <br />STEEL AND GROUT <br />FULL 8x8xl6 BLOCK <br />DOOR OPENING C <br />VERTICAL JAM <br />5/8"DIA, x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />NOT TRANSFER LOAD. <br />2x6P. <br />J-BOLT <br />TRACK <br />BRACKET <br />vWvIA r nnvn <br />W/MOUNTING ANGLE <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL GARAGE DOOR BUCK K <br />SCALE: N.T.S. S4 <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />SIZE <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />1' - 4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1) LSTA30 <br />4'- 9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />9' -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />GREATER HEADER <br />1 (2) 2x HEADER SEE PLAN <br />• INTERIOR HEADER: <br />S4 (1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />BOX HEADER . EXTERIOR HEADERS: <br />ONLY (1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(2) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6)1Old x 1 1/2" EACH <br />SIDE <br />2x STUDS TYP. <br />00 SIMPSON HTT4 TYP. <br />Op OR U.N.O. SEE N/S4 <br />HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />WALL HEADER DETAIL rQ <br />SCALE: N.T.S. S4 <br />3E <br />SIMPSON SIMPSON <br />0 <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />12 TRUSSES @ 24" O/C <br />(TYP.) SEE ELEV. UPLIFT CONNECTOR (SEE <br />SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM <br />C. 926 APPLY 3 LAYERS W/ <br />TOTAL THICKNESS 7/8" OVER <br />METAL LATH. FIRST 2 LAYERS <br />3/8" THICK EACH. 3RD LAYER <br />1/8" THICK OVER WATER <br />RESISTIVE BARRIER <br />SIMPSON SP2 w/ (12)10d <br />NAILS AT EACH STUD \jam <br />1/2" EXTERIOR GRADE SHEATHING CRICKET AS <br />FASTENED TO TRUSSES WITH 8d REQUIRED <br />COMMON WIRE NAILS @ 4" O/C <br />BOUNDARIES 6" O/C EDGES & 8" BLOCKING ( ) <br />O/C FIELD <br />2X4 PT STUDS @ 16" O.C. <br />(2) 2X4 PT STUDS UNDER HIP <br />CARRIER/GIRDER TRUSS <br />SIMPSON HETA20 w/ (8)10dx1 1/2" <br />NAILS AT EA. TRUSS VERTICAL WEB <br />(24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />IN KO BLOCK AT EA. STUD <br />MAIN SPAN <br />ROOF TRUSS <br />MOISTURE BARRIER <br />UPLIFT CONNECTOR <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />(SEE SCHEDULE) <br />AND FILLED W/ GROUT <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/ STD. 90° HOOK IN K.O. BLOCK <br />ALT. KNEEWALL ABOVE MASONRY <br />WALL DETAIL <br />SCALE: N.T.S. <br />- PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 500 OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12) 16d NAILS <br />TOP 2 ROWS 10d @ 3" O.C. (14 <br />• SPLICE NAILS TOTAL) EA. SIDE OF <br />. 4&, SPLICE STAGGERED <br />10d @ 8" O/C <br />ATTACH ALL <br />EXTERIOR STUDS <br />W/ 4 16d TOENAILS <br />TO YbP PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL rM <br />SCALE: N.T.S. S4 <br />F= 2240 LBS �7 <br />SIMPSON C <br />SIMPSON SP4 SP2 <br />P.T. <br />ATE <br />SIMPSON <br />SP4 - <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 <br />AND BB/S1 FOR <br />ADDITIONAL DETAILS <br />RECESS <br />LINTEL <br />a <br />SIMPSON <br />SP2 <br />.r <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP1 SIMPSON <br />RECESS S SIMPSON SP4 <br />LINTEL / <br />INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP4 <br />SIMPSON <br />SP1 <br />SIMPSON <br />SP4 <br />TRUSS BOTTOM CHORD OR 2x4 <br />W/ 2-16d TOE NAILS <br />'BLOCKING <br />@ EACH END <br />w <br />v <br />2x TOP PLATE <br />r Mco <br />2-16d NAILS @ 24" O.C. OR <br />EQUAL TO TRUSS BOTTOM <br />CHORD OR BLOCKING <br />2x STUD @ 24" <br />O.C. MAX. <br />P,A.F. NAILS OR <br />2x P.T. PLATE <br />FPROVIDE <br />EQUAL @ 12" O.C. <br />STAGGERED FROM BOT. <br />SEE A/S3 FOR <br />PLATE TO CONCRETE <br />REINF. INFO. <br />TYPICAL INTERIOR NON - <br />BEARING WOOD FRAME WALL <br />SIMPSON SP4 <br />�2X TOP PLATE <br />OVERLAPPING <br />10d NAILS @ 6" <br />STAGGERED <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />SCALE: N.T.S. S4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />SPF) <br />(3075# SPF) <br />i (4565# SPF) <br />i (5645# SPF) <br />i (6970# SPF) <br />IS (9335# SPF) <br />N. 8" <br />'OXIED A.T.R. <br />t & NUT <br />'OXIED A.T.R. <br />t&NUT <br />DXIED A.T.R. <br />t&NUT <br />2X8 P.T. BOTTOM P TE D <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. B <br />C (MIN. (2) PER BOTTOM PLATE) <br />SIMPSON C <br />SP4 <br />ROOF TRUSS ABOVE <br />/- 2X BLOCKING <br />0 <br />(2) 16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ Z-0" O.C. <br />MASONRY WALL <br />10d NAILS @ 4 A 10d NAILS @ 6" O.C. <br />/ STAGGERED STAGGERED <br />4 <br />2X8 P.T. BOTTOM <br />PLATE <br />D <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />A / TRANSOM FRAMING <br />° °N BEYOND. <br />-PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES ° E SHEATHING <br />& 8" O/C FIELD <br />S4 <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) SHEATHING <br />• SIMPSON SP2 w/ (12) 10d NAILS MASONRY TS @ 24" O.C. <br />• SIMPSON SP1 w/ (10) 10d NAILS WALL BELOW 5/8"X10" J-BOLTS <br />MAX. (MIN. PER BOTTOM <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY �R� <br />SCALE: N.T.S. <br />0 <br />N� <br />i <br />�� n `' 1ti •N• <br />.• <br />. <br />C� <br />v 0`� m <br />. <br />'a <br />S <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />F <br />Q <br />r- <br />of m <br />o m S N oo <br />C% <br />0 <br />N W J <br />N <br />C L <br />-2 aD ID7k �, W <br />ti <br />F <br />C� N r a u-LLI d <br />° Y <br />a <br />diva <br />v; <br />m0 �LL a w <br />Z <br />0Wo <br />Fa m 0 <br />U, <br />CC <br />9-9 0 o <br />z <br />00 o <br />N M z x Ln O <br />z <br />o0 �M N <br />W <br />ao 1 <br />CD <br />IFM <br />o g <br />z <br />N <br />z � � <br />� <br />J <br />a <br />n <br />V) <br />z <br />(D <br />Cz <br />Q) <br />o <br />u_ <br />a--� <br />0 <br />N <br />c� <br />V <br />w o <br />C <br />U <br />J <br />_ R s <br />I <br />c C2 <br />0m <br />i <br />C <br />J <br />W <br />M <br />o 0 <br />z <br />14 <br />oi a E <br />O <br />.o <br />Wo <br />zo <br />z® <br />o E <br />X OU <br />&a <br />ao <br />oL <br />0U <br />S, <br />aZ <br />CZ) <br />L <br />ao <br />¢ <br />1z <br />rp <br />(/) C <br />Y <br />m <br />O <br />Z LL <br />J <br />a <br />z z <br />tq <br />v 3 <br />a 3 <br />0 <br />g° <br />a <br />�z <br />W <br />_� <br />3:�LL <br />J w <br />=� <br />CIS <br />;o <br />cD <br />M <br />a <br />°3 <br />0 <br />> Lo <br />0� <br />rn <br />W <br />m <br />0 <br />f0 <br />J <br />M <br />N <br />0 <br />m <br />W <br />) <br />M <br />r <br />N <br />0 <br />04 <br />T <br />T_ <br />M <br />n N <br />T <br />T <br />E <br />N <br />"' <br />z <br />Z <br />E Occ <br />�; <br />n' <br />U <br />Q p <br />-1 <br />JOB <br />NO : <br />20-8088 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.