My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39752 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39752 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 2:49:42 PM
Creation date
2/19/2025 2:38:33 PM
Metadata
Fields
Template:
Building Plans
Street #
39752
Location
Harvest Creek Ln
Contractor
Lennar Homes
Building Plans - Permit #
1456
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIMPSON HGAM11 <br />W/ <br />(4)1/4"x1 1/2" SDS <br />SCREWS <br />TO BLOCKING & (� <br />1/4"X2 3/4" <br />TITEN TO CMU <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING AND <br />FASTENERS. (MIN. FIRST 4 BAYS) <br />SEE STRUCTURAL NOTES AND NAILING TOENAIL w/ <br />SCHEDULE FOR SHEATHING DETAIL-7 (2)16d NAILS--\ <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />MAX. 9" AND FASTENERS. (MIN. FIRST 4 BAYS) <br />UNSUPPORTED, <br />IF >9" SEE 1 O/S5 BACKNAIL w/ (2)16d NAILS —� <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />MAX 9" SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />UNSUPPORTED, AND FASTENERS. (MIN. FIRST 4 BAYS) —\\ <br />IF >9" SEE 10/S5 <br />BACKNAIL w/ (2)16d NAILS <br />SEE STRUCTURAL NOTES AND NAILING <br />SCHEDULE FOR SHEATHING DETAIL <br />45°± <br />z <br />45' ± <br />SEE STRUCTURAL <br />NOTES AND NAILING <br />2x4 CRO <br />BRACE <br />SCHEDULE FOR <br />APPROX. 8" FROM <br />SHEATHING DETAIL <br />2x4 KICKER <br />2x8 SYP#2 "L" BRACE TO <br />RIDGE FASTENED AT <br />@ 8'-0" O/C. <br />EXTEND AT LEAST 90% OF <br />EACH JOINT W/ (3) <br />"L" BRACE TO EXTEND <br />2x4 CROSS BRACE <br />WEB LENGTH & NOTCH AT <br />' <br />& (2)10d TOE NAILS @ <br />@ <br />• <br />AT LEAST 90% OF WEB <br />APPROX. 8" FROM <br />(SEE TABLE BOTTOM CHORD ) <br />EA. END @ 48" O.C. <br />LENGTH (SEE TABLE) <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) 8d <br />2x8 P.T. <br />GABLE TRUSS <br />EACH JOINT w/ (3) 1 Od & <br />FROM LEDGER TO <br />• <br />SILL <br />1/2" CDX PLYWOOD OR <br />(2)10d TOE NAILS @ EA. <br />END <br />'� <br />BLOCKING <br />' <br />7116" OSB SHEATHING <br />ATTACHED W/ 10d <br />GYPSUM WALL BOARD <br />GABLE TRUSS <br />NAILS @ 6" O.C. EDGES <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />1/2" CDX PLYWOOD OR 7/16" <br />' <br />AND 12" O.C. FIELD <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />SHEATHING ATTACHED <br />1 OdX3" @ 3" 0/C <br />CORD ATTACHED W/ (2)16d TOENAILS <br />w/ 1 NAILS 6 O.C. <br />w/ <br />THROUGH CHORD <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />GE <br />EDGES AND 12" O.C. FIELD <br />INTO 2"x6" P T PLATE <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />AND FASTENERS. (MIN. FIRST 4 BAYS) <br />MAX. 9" <br />UNSUPPORTED, BACKNAIL w/ (2)16d NAILS <br />IF >9" SEE 10/S5 SEE STRUCTURAL NOTES AND <br />fa NAILING SCHEDULE FOR SHEATHING <br />�- DOUBLE TOP PLATE <br />2"x4" CROSS BRACE <br />2x4 CROSS BRACE APPROX. 8" <br />APPROX. 8" FROM <br />FROM RIDGE FASTENED AT <br />RIDGE FASTENED AT <br />EACH JOINT w/ (3) 10d & (2) 10d <br />EACH JOINT w/ (3) <br />TOE NAILS @ EA. END <br />10d & (2)10d TOE <br />2x FRAME WALL (SEE WALL <br />NAILS @ EA. END <br />SECTION FOR SIZE & SPACING) <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />W/ 1Od NAILS @ 6" O.C. EDGES <br />TRUSSES FROM EA. <br />• <br />AND 12" O.C. FIELD <br />END TYP. TOP & <br />BOTTOM ATTACHED <br />( 2)16d NAILS <br />W/ (2) 16d TOENAILS <br />2x4 "T" ON TOP OF PANEL BLOCKING, 2"4" P.T. SILL NOTCH "L" BRACE HERE 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING <br />FASTEN WITH 1063" 4" 0/C SPACED WEEP SCREED THE FIRST (4) ROWS OF TRUSSES <br />@ 1/2" x 8" "J" BOLT @ 48" 0 C 2x4 "T" ON TOP OF PANEL <br />(2)16d <br />NAILS <br />@ 48" O.C. INSTALLED PER MANUF, WEEP SCREED FROM EA. END TYP. TOP & BOTTOM BLOCKING, FASTEN WITH SIMPSON HGAI OKT w/ (4)1/4"xl 1/2" SDS SCREWS TO J <br />SIMPSON META12 w/ (7) 10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C. <br />MOISTURE BARRIER 10dx3 @ 4 O/C <br />1/2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />MOISTURE BARRIER <br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER <br />SIMPSON META12 w/ (7) <br />ALTERNATE SIMPSON MSTAM24 w/ (7)1 Od NAILS <br />NOTE: IF EMBEDDED <br />1 Odx1 1/2" NAILS AT EA. <br />& (4) 1/4"x21/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL <br />SECTION <br />TRUSS VERTICAL WEB (24" <br />1 <br />GABLE WEB SECTION 2 <br />WEB, USE MSTAM36 w/ (7) <br />O.C. MAX) w/ MIN. 4" <br />10d NAILS & (4)1/4"x2 1/4" <br />SCALE: N.T.S. <br />S5 EMBEDMENT IN KO BLOCK <br />SCALE: N.T.S. <br />Srj <br />TITEN ON OUTSIDE <br />TT <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />REFER TO DETAIL J <br />N <br />N <br />AND FASTENERS. (MIN. FIRST 4 BAYS) <br />ON SHEET S5 FOR <br />r <br />f <br />X-BRACING, AND TOP <br />f2 <br />SEE STRUCTURAL <br />CHORD BLOCKING <br />N <br />F <br />NOTES AND NAILING <br />INFORMATION <br />SCHEDULE FOR <br />Ix <br />SHEATHING DETAIL <br />BACKNAIL w/ <br />1 1 <br />1/ <br />(2) 16d NAILS <br />-WOOD TRUSSES <br />`° <br />«0 <br />co <br />2"x4" CROSS BRACE <br />APPROX. 8" FROM <br />2x4 RAT RUN BRACING <br />x <br />RIDGE FASTENED AT <br />AT 24" O.C. ON TOP OF <br />EACH JOINT w/ (3) <br />BOTT. CHORD FOR 4 <br />10d & ( TOE <br />TRUSS SPANS <br />ATTACHED W/ 2 -16d <br />@ EA. END <br />NAILS @ EA <br />AT EA. TRUSS JOINT <br />(2) 2" x 4" LAMINATIONS W/ (1) ROW <br />(3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF <br />2x4 PANEL BLOCKING <br />OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS <br />@ 48" 0/C FOR THE <br />• (2) 16d NAILS <br />2x4 BLOCKING @ 24" <br />(D = 0.148", L = 3") OR EQUAL <br />(D = 0.207", L = 4 1/2") OR EQUAL (D = 0.207", L = 4 1/2") OR EQUAL <br />FIRST (4) ROWS OF <br />O/C W/ (2)16d <br />TRUSSES FROM EA. <br />TOENAILS @ EA. END <br />NOTES: <br />END TYP. TOP & <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL <br />BOTTOM ATTACHED <br />' MASONRY WALL <br />OF THE COLUMN <br />(SPACE AS SHOWN FOR 3-PLY) <br />W/ (2)16d TOENAILS <br />ARCHITECTURAL FINISH <br />2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL <br />OF THE LAST LAMINATION <br />(SPACE AS SHOWN FOR 3-PLY) <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR <br />7/16" OSB SHEATHING <br />ATTACHED w/ 1Od NAILS <br />@ 6" O.C. EDGES AND 12" <br />O.C. FIELD <br />2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />1Odx3" @ 4" O/C <br />DBL. TOP PLATE SIMPSON SP2 w/ (12)10d <br />2x4 LEDGER (MATCH BOTTOM CHORD NAILS AT EACH STUD <br />SLOPE OF ADJACENT TRUSS) STUD WALL (SEE TYP. SEC.) <br />SECTION 3 SECTION 4 <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR 7/16" <br />OSB SHEATHING ATTACHED <br />W/ 10d NAILS @ 6" O.C. <br />E ES AND 12" O.C. FIELD <br />XCJACK TRUSS <br />SEE PLAN FOR <br />CONNECTION <br />2x4 "T" ON TOP OF PANEL <br />EXT. WALL CONN. a� <br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION <br />BLOCKING, FASTEN WITH <br />1Odx3" @ 4" O/C <br />2x4 BLOCKING W/ <br />(2)12d TOENAILS <br />NON - LOAD BEARING LOCATIONCOMMON <br />rD <br />NAILS. (ONE INTO EACH OUTSIDE FACE OF <br />- <br />B.U.C., SAME NUMBER OF ROWS, SAME SPACING) <br />TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 <br />SECTION <br />9 <br />SEE TYP. WALL SECTION FOR SCALE: 3/4"=V-0" S5 <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. S5 <br />SCALE: N.T.S. <br />S5 <br />1INIMUM 2x <br />;ROSS BRACING <br />SEE PLAN FOR <br />OCATIONS) TOENAIL <br />(2)16d NA <br />(2)16d PER <br />JOINT <br />2"x4" MIN, SEE M/S5 <br />CROSS BRACING DETAIL <br />SCALE: N.T.S. <br />12" <br />!SH SCHEDULE <br />tTTACHMENT <br />2 SYP BLK'G @ 16" O.C. <br />i x 0.131" <br />AILS EA. SIDE <br />2x4 #2 SYP W/ 1 Od <br />X0.131" @ 8" O.C. <br />ALTERNATE NON -DROP <br />GABLE END DETAIL 10 <br />SCALE: N.T.S. S5 <br />1 GABLE TRUSS <br />S5 <br />"L" BRACE W/ 10d @ 4" O.C. <br />12 (SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />6.9 MAX. <br />S5 <br />GABLE END BRACING DETAIL <br />S5 <br />CONT. BEARING <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES <br />MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL <br />SCALE: N.T.S. <br />6" OVERLAP <br />M <br />S5 <br />"L" BRACE W/ 10d @ 4" 0/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"O/C <br />WOOD TRUSSES <br />SIMPSON HGAMI OKTA W/ (4) <br />1/4"x1 1/2" SDS SCREWS TO <br />BLOCKING & (4)1/4"X2 3/4" <br />TITEN TO CMU <br />2 x 4 BLOCKING w/ (2)1 Od <br />TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />0 <br />z <br />9 <br />BRACING w/ (3)1 Od x 3" AT = <br />• EACH CONN. @ 24" O/C <br />MOISTURE BARRIER <br />BOND BEAM <br />-MASONRY WALL <br />ARCHITECTURAL FINISH <br />EXT. WALL CONN. NON -LOAD <br />BEARING LOCATIO (UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.O.) <br />"L" BRACE <br />2"x6" (U.N.O.) <br />"L" BRACE <br />24" <br />0'0" - 3'-0" <br />T-O" - 6'-0" <br />64' & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" 0/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4) 1/4"xl 1/2" SDS <br />vviv . u�nnuva — <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMPSON SP2 wl (12) <br />10d NAILS AT EACH <br />STUD <br />END JACK <br />1 V-0" MAX. <br />p <br />It <br />0 <br />a <br />�r <br />CORNERJACK <br />w <br />z <br />0 <br />U <br />HIP FRAMING REFERENCE PLAN <br />20'-0" MAX <br />'W BRACE SEE DET. J/S5 <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />L" BRACE <br />ATTACHED W/ <br />10d NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 7' BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 10d NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" 0/C GABLE TRUSS <br />TRUSS VERTICAL <br />(2) 2"x8" "L" BRACE J <br />FASTENED WITH (3) <br />16d PER SIDE <br />SCISSOR GABLE "T" BRACE <br />AS PER HIB 91 SCALE: N.T.S. S5 <br />20'-0" MAX <br />CONTINUOUS BOTTO� CHORD BRACING 2X4 MIN. <br />NOTE: LTOP CHORD 2X4 #2 SYP BRACING <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />@ 16" O.C. MAX. FOR FIRST (4) <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />BAYS <br />THAT MY BE REQUIRED <br />BOTTOM CHORD GABLE END BRACING <br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT <br />@ 4'-0" O.C. MAX. FOR FIRST (4) BAYS <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2) 10d AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />W/ DROP CEILING BRACING DETAIL <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />'tom <br />("c�l <br />V <br />!p <br />r <br />N• <br />�•. <br />G Q` <br />/�11011111111 <br />lilt tlil <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />114 <br />4 <br />w0 <br />n <br />O R E <br />0 <br />N m J IJi <br />N W <br />ui <br />7 ,n W <br />N U- CLY <br />ai V <br />LL LL a <br />00 <br />v' <br />Z_ <br />J l <br />L�� �o <br />W <br />5 j 04N 2 M O <br />corn°' a a <br />Z <br />LL <br />0 a <br />N co M z O <br />O U U 5 0 <br />Z <br />w <br />❑❑❑ <br />� N M <br />0 <br />0 <br />Z - 9 <br />C <br />V I <br />N <br />o <br />U <br />�• <br />O_� <br />W S <br />C y <br />U <br />W <br />J E <br />L <br />U o N <br />Q 0 <br />—� <br />• <br />sm <br />�W <br />M <br />M <br />z <br />o <br />z <br />� <br />.J <br />U_ <br />Q E <br />E OV <br />g0 <br />z <br /><R �® <br />od <br />N <br />0. I <br />g <br />X U <br />�a <br />U O <br />U <br />N <br />ao <br />4❑ <br />ww <br />L <br />ra <br />C0 C <br />_ <br />OY <br />U <br />�m <br />m0 <br />0 <br />O <br />Z <br />W <br />J <br />am <br />QW <br />N <br />3 <br />p <br />W <br />Z. <br />a o <br />Z <br />0o <br />�_ <br />Y <br />t <br />co <br />W F <br />a0 <br />h <br />° 3 <br />0 <br />cCD <br />> Lo <br />M <br />L <br />ui <br />B <br />^, <br />W <br />� <br />. - <br />C <br />I� <br />f° <br />M <br />O <br />a <br />III m <br />U <br />Q0 <br />W <br />� <br />� <br />?_ 04 <br />(a O <br />2 N <br />0,11 <br />1^ <br />I� <br />M <br />n N <br />0 r <br />It— <br />E <br />+=CNIIz <br />M <br />o <br />M <br />E O <br />a <br />E .. <br />U <br />a °3 <br />Q 0 <br />c <br />JOB <br />NO: <br />20-8088 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.