1 1 /2"
<br />1 1 /2" V
<br />4" SAN. I.E. - 4.00' FOR CONT.
<br />REFER TO CIVIL DWGS.
<br />GENDER NEUTRAL
<br />1 11 "V UP FROM
<br />LAV, 314" HW/CW DN
<br />TO LAV-1
<br />1112"VUP
<br />FROM EDF-1
<br />1/2" CW DN
<br />TO EDF-1
<br />BREAK 11/ "VUPFROM�
<br />ROOM LAV, 3 4" HW/CW DN
<br />716-01 TO LAV-1
<br />SALES AREA
<br />102 WH-1
<br />RECEIVING
<br />103
<br />314" CW DN--/
<br />TO WH-1
<br />C 2') OFFICE V TO 4" VTW.
<br />B 101 -7
<br />ELBO DN, COVER
<br />O OPENI G WINSECT t SCREEN.
<br />_k
<br />1 PLUMBING PLAN NORTH
<br />Scale. 1/8 = 1-0
<br />PLUMBING FIXTURE SCHEDULE
<br />MARK
<br />DESCRIPTION
<br />HW
<br />CW
<br />WASTE
<br />VENT
<br />REMARKS
<br />CONNECTION
<br />CONNECTION
<br />CONNECTION
<br />CONNECTION
<br />20"X18" WALL HUNG ADA LAVATORY W/ FRONT OVERFLOW, CONCEALED HANGERS & 4" CENTERS.AMERICAN STANDARD LUCERNE
<br />#0355.012 OR EQUAL. FAUCET SHALL BE POLISHED CHROME -PLATED CAST BRASS BODY WITH 4" SPOUT, 4" BRASS WRIST BLADE, 0.5
<br />LAV-1
<br />ADA LAVATORY
<br />1/2"
<br />1/2"
<br />2"
<br />1-1/2"
<br />GPM SPRAY AND POP-UP DRAIN. AMERICAN STANDARD MONTERREY #5502.175 PROVIDE WATTS MODEL USG-B-M1 ASSE 1070 MIXING
<br />VALVE OR EQUAL. INSULATED EXPOSED DRAIN & WATER PIPES WITH TRUEBRO LAV GUARD KIT #102 E-Z. PROVIDE SUPPLIES, STOP
<br />VALVES AND P-TRAP.
<br />FLOOR MOUNTED ADA VITREOUS CHINA ELONGATED 1.28 FLUSH GALLON CLOSE COUPLED TWO PIECE SIPHON JET WATER CLOSET,
<br />WC-1
<br />ADA WATER CLOSET
<br />-
<br />1/2"
<br />4"
<br />2"
<br />FLUSH TANK WITH 12" ROUGH -IN. AMERICAN STANDARD CHAMPION 4 "RIGHT HEIGHT" #2002.014 OR EQUAL. PROVIDE STOP VALVE,
<br />FLEXIBLE SUPPLY LINE, OPEN FRONT SEAT (AMERICAN STANDARD #5901.100 OR EQUAL).
<br />FLOOR MOUNTED ADA VITREOUS CHINA ELONGATED 1.28 FLUSH GALLON CLOSE COUPLED TWO PIECE SIPHON JET WATER CLOSET,
<br />ADA WATER CLOSET RIGHT-
<br />FLUSH TANK WITH 12" ROUGH -IN. AMERICAN STANDARD CHAMPION 4 "RIGHT HEIGHT" #2002.014 OR EQUAL WITH ALTERNATE TANK
<br />WC-2
<br />HAND TRIP LEVER
<br />1/2"
<br />411
<br />2"
<br />ASSEMBLY #4266.804 (RIGHT HAND TRIP LEVER). PROVIDE STOP VALVE, FLEXIBLE SUPPLY LINE, OPEN FRONT SEAT (AMERICAN
<br />STANDARD #5901.100 OR EQUAL).
<br />PROVIDE 10 GALLON ELECTRIC WATER HEATER, 1.65KW @ 120V WITH MANUFACTURER SUPPLIED TEMPERATE AND PRESSURE RELIEF
<br />VALVE. (A.O. SMITH #EJC-10, OR EQUAL).
<br />SET WATER HEATER TEMPERATURE AT 120°F MAXIMUM. PROVIDE HOT WATER TEMPERING VALVE SET AT 120°F. REFER DETAIL 2/P2.
<br />PROVIDE THERMAL EXPANSION TANK. (AMTROL THERM-X-TROL ST-12, OR EQUAL).
<br />ELECTRIC WATER
<br />EXPANSION TANK SUPPORT:
<br />EWH-1
<br />HEATER
<br />3/4"
<br />3/4"
<br />-
<br />-
<br />IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SUPPORT FOR THE EXPANSION TANK. SUPPORT TO ADJACENT WALL
<br />OR FROM EXISTING STRUCTURE ABOVE WITH UNISTRUT. DO NOT SUPPORT FROM PIPE ALONE.
<br />PROVIDE DRAIN PAN UNDER WATER HEATERS.
<br />PROVIDE SEISMIC STRAPPING ON WATER HEATERS.
<br />TERMINATE (EWH-1) DRAIN LINE IN HUB DRAIN (HD-1) DRAIN LINE IN MOP SINK (MS-1). PROVIDE FULL SIZE T&P RELIEF LINE, REFER TO
<br />WATER HEATER DETAIL ON SHEET P2 FOR ADDITIONAL INFORMATION.
<br />24" X 24" MOLDED STONE MOP SERVICE BASIN, WITH T DRAIN. FIAT #MSB-2424 OR EQUAL. PROVIDE SERVICE
<br />MS-1
<br />MOP SINK
<br />3/4"
<br />3/4"
<br />3"
<br />2"
<br />FAUCET WITH PAIL HOOK & INTEGRAL VACUUM BREAKER, MOP BRACKET, FLAT STAINLESS STEEL STRAINER AND HOSE & BRACKET. FIAT
<br />#830 AA, 889 CC, 1453 BB & 832 AA OR EQUAL. PROVIDE SUPPLIES AND P-TRAP.
<br />BARRIER FREE ELECTRIC
<br />TWO -STATION, WALL MOUNTED, ELECTRIC DRINKING FOUNTAIN, BARRIER -FREE ACCESS (ADA), FRONT ONLY EASY TOUCH CONTROL,
<br />EDF-1
<br />DRINKING FOUNTAIN
<br />1/2"
<br />-
<br />2"
<br />1-1/2"
<br />HIGH UNIT ON RIGHT. ELKAY #EZTLRDDC OR EQUAL. PROVIDE SUPPLY, STOP VALVE & P-TRAP. PROVIDE CANE APRON AS REQUIRED.
<br />FREEZE -PROOF WALL HYDRANT WITH BRONZE BODY & ANTI -SIPHON VACUUM BREAKER, BOX AND LOCKING COVER. PROVIDE WITH
<br />WH-1
<br />WALL HYDRANT
<br />3/4"
<br />_
<br />_
<br />_
<br />HOSE CONNECTION AND MOUNT AT 24" ABOVE GRADE. WOODFORD #B65 OR EQUAL.
<br />WCO-1
<br />WALL CLEAN -OUT
<br />_
<br />-
<br />AS SHOWN ON
<br />-
<br />SIZE & INSTALL AS SHOWN ON PLANS. JOSAM, ZURN OR EQUAL.
<br />PLANS
<br />HD-1
<br />HUB DRAIN
<br />1/2"
<br />-
<br />3"
<br />2"
<br />PROVIDE 3" PIPE SIZE WITH FUNNEL AND 1/2" O TRAP PRIMER CONNECTION. JOSAM, ZURN OR EQUAL.
<br />PROVIDE PRESSURE DROP ACTIVATED BRASS TRAP SEAL PRIMER, WITH REMOVABLE FILTER SCREEN. MIFAB #M2-500. NO
<br />TP-1
<br />TRAP PRIMER
<br />-
<br />1/2"
<br />_
<br />-
<br />SUBSTITUTIONS.
<br />PROVIDE AIR GAP FITTING. MIFAB #MIGAP. NO SUBSTITUTIONS.
<br />PROVIDE DISTRIBUTION UNIT, WHERE TRAP PRIMER SERVES MULTIPLE FLOOR DRAINS, MIFAB #MI-DU-500. NO SUBSTITUTIONS.
<br />ECO-1
<br />EXTERIOR CLEAN -OUT
<br />-
<br />-
<br />4"
<br />-
<br />PROVIDE TRAFFIC RATED, 2-WAY, EXTERIOR CLEANOUT. TYLER PIPE #003519, OR EQUAL.
<br />FCO-1
<br />FLOOR CLEAN -OUT
<br />_
<br />_
<br />AS SHOWN ON
<br />PROVIDE ADJUSTABLE FLOOR CLEANOUT WITH WATERTIGHT TAPERED THREADED PLUG AND ROUND SCORIATED SECURED TOP,
<br />PLANS
<br />ADJUSTABLE TO FINISHED FLOOR. SIZE & INSTALL AS SHOWN ON PLANS. JOSAM, ZURN OR EQUAL.
<br />NOTES:
<br />1. PUBLIC SANITARY SEWER CONNECTION IS REQUIRED.
<br />2. SEPTIC SYSTEM NOT ALLOWED WITHOUT WRITTEN
<br />APPROVAL OF DOLLAR GENERAL STORE DESIGN.
<br />3. HOLDING TANK SYSTEMS ARE NOT ALLOWED.
<br />4. LIFT STATIONS ARE NOT ALLOWED WITHOUT DOLLAR
<br />GENERALAPPROVAL.
<br />5. CONTRACTOR RESPONSIBLE FOR ALL PUBLIC UTILITY
<br />CONNECTIONS (GAS, WATER, ELECTRIC, SEPTIC) AS WELL
<br />AS INFRASTRUCTURE REQUIRED BY UTILITY COMPANY.
<br />6. COORDINATE CLEANOUT LOCATION WITH FIXTURE
<br />LAYOUT.
<br />7. EWH-1 REQUIRES PAN DRAIN TERMINATION AND MEANS
<br />OF PREVENTING AND CONTROLLING THERMAL
<br />EXPANSION. REFER TO 2020 FBC.
<br />2" V TO 4" VTW,
<br />ELBOV I DN, COVER
<br />OPENIN W/ INSECT
<br />SCREEN.
<br />2"VUP
<br />2" V DN TO WC-1
<br />WC-1 I
<br />I
<br />I
<br />1/2" CW DN
<br />I I
<br />TO WC-1
<br />REFER TO 1/P1
<br />2" V FOR CONT.
<br />LAV-1 I
<br />I
<br />I
<br />I
<br />0
<br />ioN I
<br />3/4" HW
<br />EDF-1
<br />SALES AREA
<br />102
<br />illCW
<br />oIJ i 1" CW
<br />I
<br />---- -7
<br />2"V
<br />3/4" HW
<br />LAV-1
<br />I
<br />GENDER NEUTRAL
<br />I
<br />I
<br />105
<br />I I
<br />2"VUP
<br />W L
<br />2" V DN TO WC-1
<br />WC-1Xi
<br />1/2" CW DN TO WC-1
<br />- —H
<br />ISOLATION VALVE (TYP)
<br />3/4" HW
<br />DN TO MS-1
<br />WCO-1
<br />EWH-1
<br />1 1/2" V DN
<br />ENLARGED RESTROOM AND RECEIVING AREA PLAN
<br />Scale: 1/4" = V-0"
<br />CONSULTANT:
<br />SEAL: HENRY D. MONTAGUE, PE 78172
<br />0NAN IyO�V�>ii
<br />�10
<br />i e =
<br />••,�At�OP ' w:
<br />�Q PL
<br />THIS R ING SHALL NOT BE USED FOR
<br />CONSTR TION PURPOSES UNTIL THE SEAL AND
<br />SIGNATURE OF THE RESPONSIBLE REGISTRANT
<br />APPEARS ON THE DRAWING, AND PROPER PERMIT
<br />FORMS AND RELATED FEES ARE TRANSMITTED BY
<br />THE OWNER, OWNER'S AGENT OR CONTRACTOR
<br />TO THE AUTHORITY HAVING JURISDICTION.
<br />DATE
<br />ISSUED FOR
<br />REV
<br />03/29/2021
<br />PEMB COORDINATION
<br />05/20/2021
<br />CIVIL SUBMISSION
<br />05/20/2021
<br />DUKE COORDINATION
<br />06/07/2021
<br />PEMB COORDINATION 02
<br />08/09/2021
<br />CIVIL RESUBMISSION 1
<br />08/25/2021
<br />OWNER REVIEW
<br />1 1 /08/2021
<br />REVISED ELEVATIONS
<br />11/29/2021
<br />PERMIT SUBMITTAL
<br />Project Manager
<br />Drawn
<br />L. LONG
<br />M. MIZWA
<br />Project Leader
<br />Checked
<br />L. LONG
<br />H. MONTAGUE
<br />Date
<br />Dept Mgr Approval
<br />02/23/2021
<br />H. MONTAGUE
<br />Client
<br />PALMETTO ZEPHYRHILLS - GALL BLVD., LLC
<br />P.O. Box 1615,
<br />Thomasville, GA 31799
<br />Office: (229) 226-1177
<br />Contact: Daniel Tubb
<br />Project
<br />DOLLAR GENERAL
<br />Corner of Gall Boulevard and C
<br />Avenue,
<br />Zephyrhills, FL 33542
<br />(City of Zephyrhills)
<br />Store #: 23227
<br />Drawing Title
<br />PLUMBING PLANS
<br />AND SCHEDULE
<br />DO NOT SCALE DRAWING
<br />Project No.
<br />Drawing No.
<br />JCDT.20.0451
<br />P1