WATER HEATER EWH-1 DETAIL (NOT USED'
<br />SHUT-OFF VALVE
<br />C.W. MAKE-UP
<br />H.W. TO FIXTURES
<br />THERMAL EXPANSION TANK SIZE
<br />PER MFG. RECOMMENDATIONS -
<br />TEMPERATURE AND
<br />PRESSURE RELIEF VALVE
<br />DISCHARGE FULL SIZE OF VALVE
<br />DISCHARGE PIPE TO MOP SINK OR
<br />FLOOR DRAIN AND TERMINATE
<br />WITH ELBOW TURNED DOWN
<br />1" DRAIN LINE. ROUTE TO MOPSINK
<br />OR FLOOR DRAIN AND TERMINATE
<br />WITH ELBOW TURNED DOWN �
<br />i
<br />PROVIDE AND INSTALL WALL MTD.
<br />MOP HOLDER SO MOPS ALWAYS
<br />DRIP INTO MOP SINK.
<br />PROVIDE 2" AIR GAP
<br />FOR T&P RELIEF AND
<br />DRAIN LINE PIPING
<br />RECEIVING AREA FLOOR
<br />ALUMINUM CORNER GUARDS
<br />ON MOP SINK WING WALL.
<br />Scale: No Scale
<br />WATER HEATER
<br />"EWH-1"
<br />MOP SINK
<br />WATER HEATER"' SERVICE CLOSET
<br />Scale: No Scale
<br />VENT
<br />VENT
<br />4 �T�
<br />VACUUM BREAKER
<br />HEAT TRAP
<br />4" DEEP GALV. DRAIN PAN
<br />1 "CW
<br />0
<br />ro WH-1
<br />1„CW
<br />/ 3/4"C W
<br />\ 3/4"HW
<br />WC-1 \,
<br />3/4"HW
<br />\
<br />3/4"CW
<br />� TP-1 \.
<br />LAV-1 TRAP PRIMER\ 3/4"HW
<br />0 r/2'
<br />TO HUB DRAIN 1 "CWH W
<br />EDF-1 3/4"CW \
<br />3/4"CW
<br />WC-1 1 "CW
<br />1" CW U/G.
<br />FOR CONT. IV-1 1/2"CW o
<br />REFER TO
<br />CIVIL DWGS. PIAAu_1
<br />EWH-1 TO DRAIN INTO
<br />MOP SINK (MS-1
<br />)
<br />REFER TO SHEET P1 FOR
<br />ADDITIONAL INFORMATION.
<br />INSTALL WATER HEATER ABOVE MOP SINK
<br />AT T-6" A.F.F. ON 8" 20 GA. STEEL STUD
<br />JOISTS SPACED 8" O.C. SPANNING
<br />SURROUNDING WALLS. COORDINATE
<br />STRUCTURAL SUPPORT FRAMING WITH
<br />GENERAL CONTRACTOR.
<br />INSTALL FRP @ 48" A.F.F.
<br />60" WIDE ON THIS WALL.
<br />45' I
<br />N.
<br />r � OpR
<br />SOIL OR
<br />WASTE
<br />SEWER
<br />i
<br />i NOTE:
<br />CONNECT VENT TO SOIL OR WASTE PIPING
<br />SOIL OR i ABOVE CENTERLINE. UNDER SLAB HORIZONTAL
<br />WASTE j CONNECTIONS OF VENT PIPING TO WASTE
<br />SEWER SEWER SYSTEM PIPELINE SHALL NOT BE
<br />ALLOWED.
<br />VENT PIPE INSTALLATION DETAIL
<br />Scale: No Scale
<br />WH-1
<br />COLD & HOT WATER DIAGRAM
<br />Scale: No Scale
<br />4" VENT THRU WALL.
<br />ELBOW DN AND COVER
<br />W/ INSECT SCREEN
<br />2"V
<br />i
<br />2" V
<br />WC-1
<br />I
<br />3/4"H W
<br />MS-1
<br />3/4"C W
<br />1 1/2" V
<br />r r' 1
<br />1 1/2" V4" SAN i 1 1/2" VENT THRU WALL.
<br />LAV-1
<br />EDF-1 i �� FCO-1
<br />i 4" SAN
<br />i
<br />i
<br />i WCO-1 L
<br />J
<br />3' SAN i HD-1 1 1/2" V
<br />4" SANS / �LAV-1
<br />FLUSH WITH
<br />FLOOR LINE
<br />CLEAN -OUT TO BE TYLER PIPE
<br />MODEL 003533 SERIES OR EQUAL
<br />INSTALLATION SHALL BE FLUSH WITH
<br />SURROUNDING FLOOR SURFACES. —
<br />REFER TO SHEET P1 FOR
<br />ADDITIONAL INFORMATION.
<br />SANITARY & VENT DIAGRAM
<br />Scale: No Scale
<br />ELBOW DN AND COVER
<br />W/ INSECT SCREEN
<br />4" SAN
<br />FCO-1
<br />WC-1
<br />1 1/2" V
<br />WCO-1
<br />4" SAN
<br />3" SAN
<br />MS-1
<br />EXTRA HEAVY DUTY CAST
<br />IRON ADJUSTABLE SCORIATED
<br />SECURED COVER.
<br />BRONZE TAPER THREAD PLUG
<br />WITH COUNTER SUNK HEAD
<br />`N
<br />I
<br />\-FLANGE
<br />WASTE LINE LENGTH TO SUIT
<br />FLOW 4„ FLOW 4
<br />THIS DETAIL USED FOR 4"
<br />SANITARY LINE RUN
<br />BELOW FIXTURE RACKING.
<br />SEE PLANS.
<br />2—WAY YARD CLEAN OUT DETAIL —WAY YARD CLEAN OUT DETAIL
<br />Scale: No Scale
<br />GENERAL PLUMBING NOTES & SPECIFICATIONS
<br />1. GENERAL NOTES ARE APPLICABLE TO ALL PLUMBING WORKING DRAWINGS.
<br />2. THE WORK SHALL BE EXECUTED IN STRICT CONFORMITY WITH BASE BUILDING SPECIFICATION AND WITH THE LATEST
<br />EDITION OF THE PREVAILING LOCAL PLUMBING AND BUILDING CODES AND ALL LOCAL REGULATIONS THAT MAY APPLY. IN
<br />CASE OF CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND A GOVERNING CODE OR ORDINANCE THE MORE STRINGENT
<br />STANDARD SHALL APPLY.
<br />3. ALL PLUMBING WORK SHALL BE COORDINATED WITH ALL OTHER TRADES BEFORE PROCEEDING WITH INSTALLATION.
<br />4. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND FOR PAYING RELATED
<br />FEES.
<br />5. ROUGH -IN DIMENSIONS OF TOILET FIXTURES MUST BE COORDINATED WITH GENERAL CONTRACTOR AND FIELD
<br />SUPERVISOR.
<br />6. INSTALL BALL VALVES ON ALL BRANCH SUPPLY LINES.
<br />7. PROVIDE ACCESS PANELS ON ALL INACCESSIBLE VALVES AND CLEANOUTS. ACCESS PANELS SHALL BE PROVIDED BY
<br />GENERAL CONTRACTOR. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR THEIR LOCATION. MOUNT SHUT-OFF
<br />VALVES NO HIGHER THAN 12'-8" AFF.
<br />8. ALL WORK SHALL BE PROPERLY TESTED, BALANCED AND CLEANED. PROVIDE A ONE YEAR WARRANTY FROM DATE OF FINAL
<br />INSPECTION ON ALL PARTS AND LABOR.
<br />9. FOLLOW PDI STANDARDS FOR WATER HAMMER ARRESTORS.
<br />10. ALL FIXTURES TO BE SUPPLIED & INSTALLED BY PLUMBING CONTRACTOR,.
<br />11. GENERAL CONTRACTOR SHALL COORDINATE WATER METER LOCATION AND INSTALLATION WITH LOCAL AUTHORITIES AND
<br />CIVIL DRAWINGS.
<br />12. PROVIDE BUILDING SERVICE LINE 5-0" FROM BUILDING LINE, OR INSIDE BUILDING FROM OUTLET SIDE OF METER AS SHOWN
<br />ON CIVIL SITE PLAN. COORDINATE EXACT LOCATION WITH CIVIL DRAWINGS AND AT JOB SITE. IF LOCAL MUNICIPALITIES
<br />REQUIRE BACKFLOW PREVENTION DEVICE, A MINIMUM RPZ TYPE SHALL BE PROVIDED.
<br />13. SANITARY SEWER PIPING SHOWN IS BASED ON 0.125"/FT FOR 3"-6" & 0.25"/FT FOR 2 1/2" OR LESS FOR ALL PIPING.
<br />COORDINATE BUILDING SEWER LOCATION AND INVERT ELEVATION WITH CIVIL DRAWINGS.
<br />14. TRAP SEAL PRIMERS ARE TO BE PROVIDED AT NO ADDITIONAL COST TO OWNER IF REQUIRED BY LOCAL BUILDING CODE
<br />OFFICIALS.
<br />15. VTR'S SHALL BE LOCATED A MINIMUM OF 5' FROM ANY PARAPET WALL AND 10' FROM ANY RTU AIR INTAKE.
<br />16. FURNISH ALL MATERIAL, LABOR, EQUIPMENT, AND ACCESSORIES AS REQUIRED TO INSTALL COMPLETE PLUMBING AND HVAC
<br />PIPING SYSTEMS AS INDICATED ON MECHANICAL DRAWINGS AND IN THESE SPECIFICATIONS.
<br />17. SANITARY SEWERS
<br />a. INSTALL SANITARY SEWERS, STACKS, VENTS, DRAINS, CLEANOUTS, ETC., AS INDICATED ON THE DRAWINGS.
<br />b. SEWERS TO BE PITCHED A MINIMUM OF 1/4" PER FOOT FOR 3" SIZES AND UNDER AND 1/8" PER FOOT FOR 4" SIZES AND
<br />LARGER OR TO GRADES INDICATED ON DRAWINGS.
<br />c. CHANGES IN DIRECTION AND BRANCH CONNECTIONS SHALL BE MADE WITH APPROVED DRAINAGE FITTINGS
<br />COMPATIBLE WITH THE PIPING SYSTEM MATERIAL IN WHICH IT IS INSTALLED.
<br />d. ALL FIXTURES AND SANITARY DRAINS SHALL BE VENTED AS INDICATED ON DRAWINGS AND IN ACCORDANCE WITH CODE.
<br />e. VENTS ARE TO BE EXTENDED THROUGH WALL IN ACCORDANCE WITH PEMB MANUFACTURER'S DETAILS OR THROUGH
<br />ROOF AS INDICATED ON DRAINS AND FLASHED WITH 4 LB. LEAD WITH VENT FLASHING TOP TURNED DOWN TWO (2)
<br />INCHES MINIMUM INSIDE PIPE.
<br />18. BELOW GRADE SANITARY INSIDE BUILDING
<br />a. SERVICE WEIGHT - PVC AND CPVC ASTM A74-82 WITH ASTM C564-70 NEOPRENE COMPRESSION JOINTS OR NO -HUB
<br />b. PVC-DWV PLASTIC ASTM D1785 WITH ASTM D2665 DWV SOLVENT WELD SOCKET FITTINGS.
<br />19. ABOVE GRADE SANITARY SEWER AND VENT
<br />a. NO -HUB CAST IRON PIPE CISPI 1-301-78.
<br />b. PVC-DWV PLASTIC ASTM D1785 WITH ASTM D2665 DWV SOLVENT WELD SOCKET FITTINGS (IN CONCEALED AREAS ONLY,
<br />PVC SHALL NOT BE INSTALLED IN CEILING PLENUMS).
<br />c. SCHEDULE 40 GALVANIZED STEEL PIPE, ASTM A53-83 WITH CAST IRON SCREWED FITTINGS ANSI B16.22 1983.
<br />20. DOMESTIC WATER PIPING
<br />a. INSTALL DOMESTIC WATER PIPING AS INDICATED ON DRAWINGS. INCLUDE ALL FITTINGS, VALVES, HANGERS AND OTHER
<br />ACCESSORIES. EXTEND DOMESTIC WATER PIPING TO ALL FIXTURES AND EQUIPMENT REQUIRED FOR COMPLETE
<br />INSTALLATION.
<br />b. INCLUDE UNIONS, OR OTHER DISCONNECT MEANS, STOPS OR VALVES FOR ISOLATION OF FIXTURES AND EQUIPMENT.
<br />VALVES TO BE FULLY COMPATIBLE WITH PIPING FOR SERVICE INTENDED AS MANUFACTURED BY NIBCO, CRANE OR
<br />MILWAUKEE. INCLUDE HOSE OR DRAIN VALVES AT LOW POINTS WHERE FIXTURES CANNOT BE USED FOR DRAINAGE.
<br />c. PROVIDE WATER HAMMER ARRESTERS OF TYPE AS INDICATED ON THE DOMESTIC WATER RISER DIAGRAM. THESE
<br />SHALL BE ASSE 1010 OR PDI-WH2O1, PISTON TYPE WITH PRESSURIZED METAL -TUBE CUSHIONING CHAMBER AS
<br />MANUFACTURED BY SIOUX CHIEF, AMTROL, JOSAM OR ZURN.
<br />d. HANGERS ON INSULATED PIPE TO BE OUTSIDE OF INSULATION, SIZED ACCORDINGLY AND WITH A SUFFICIENT SADDLE
<br />TO PROTECT INSULATION.
<br />21. DOMESTIC WATER PIPING SHALL BE AS FOLLOWS:
<br />a. ABOVE GRADE - TYPE "L" HARD COPPER ASTM B88-832 WITH WROUGHT COPPER FITTINGS ASTM B16.22 1980 AND
<br />NON -LEAD OR ANTIMONY SOLDER JOINTS.
<br />b. BELOW GRADE - CPVC OR PVC WITHOUT SPLICES OR FITTINGS.
<br />c. FLUSH, VENT AND SANITIZE ALL WATER PIPING WITH CHLORINE AS REQUIRED PER AWWA, LOCAL BUILDING
<br />DEPARTMENT AND HEALTH DEPARTMENT CODES.
<br />d. DOMESTIC HOT AND COLD WATER PIPING UNDER CONCRETE FLOOR TO BE COVERED WITH SAND SO THAT PIPING WILL
<br />NOT BECOME EMBEDDED IN THE FLOOR SLAB.
<br />e. ALL PIPING UNDER CONCRETE FLOOR SHALL BE CPVC PIPING, CONTINUOUS. NO SPLICES OR FITTINGS WILL BE
<br />ALLOWED.
<br />f. EXTREME CAUTION MUST BE TAKEN SO THAT NO PIPING AND INSULATION UNDER CONCRETE FLOORS BECOMES
<br />CRUSHED, CUT, SPLIT OR DEFORMED DURING THE POURING OF THE FLOOR SLAB.
<br />PROVIDE CLEANOUT WITH ADJUSTABLE CLEANOUT
<br />TOP WITH VARIATIONS SUITABLE FOR FLOOR
<br />COVERING (CARPET MARKER, RECESSED FOR TILE,
<br />SCORIATED FOR UNFINISHED FLOORS). CLEAN THE CLEANOUT PLUG AS SPECIFIED.
<br />TOP OF EXPOSED FCO AFTER INSTALLATION. APPLY TEFLON JOINT COMPOUND
<br />TO THE CLEANOUT PLUG THREADS
<br />fy
<br />FLOOR SLAB ON GRADE
<br />SAME SIZE AS SEWER
<br />UP TO 4" MAXIMUM MEMBRANE CLAMP
<br />AS REQUIRED FOR LONG SWEEP ELBOW AT
<br />DEPTH OF SEWER END OR TURN OF RUN
<br />SANITARY AND/OR COMBINATION WYE AND
<br />STORM SEWER, SIZE EIGHTH BEND IN RUN,
<br />PER PLAN REDUCING TYPE IF REQUIRED,
<br />ENTER TOP OF PIPE.
<br />DIRECTION OF FLOWF _16
<br />REFER TO SPECIFICATIONS AND SCHEDULE FOR MORE
<br />INFORMATION. LOCATE AT BUILDING EXIT, AT ENDS OF RUNS,
<br />AT TURNS OF PIPE GREATER THAN 45°, AT 50' INTERVALS ON
<br />STRAIGHT RUNS, AND/OR WHERE SHOWN ON PLANS AND
<br />RISERS. PROVIDE BACKFILL PER ARCHITECTURAL
<br />SPECIFICATIONS. LOCATE CLEANOUT WHERE THERE IS 18"
<br />CLEAR AROUND, FOR ACCESSIBILITY. CONSULT LOCAL CODES
<br />AND OFFICIALS FOR OTHER REQUIREMENTS.
<br />FLOOR CLEAN OUT DETAIL
<br />(7
<br />Scale: No Scale
<br />LEGEND
<br />SS
<br />SANITARY SEWER
<br />-- - -—
<br />DOMESTIC COLD WATER
<br />—
<br />DOMESTIC HOT WATER
<br />CD
<br />CONDENSATE DRAIN
<br />--
<br />PLUMBING VENT
<br />UNION
<br />— I
<br />i
<br />PLUG COCK
<br />C -
<br />ELBOW - TURNED DOWN
<br />a ---
<br />ELBOW - TURNED UP
<br />-- - --
<br />TEE - TURNED DOWN
<br />--�--
<br />TEE - TURNED UP
<br />- ��--
<br />GATE VALVE
<br />--I O F---
<br />BALL VALVE
<br />--��-
<br />CHECK VALVE
<br />_—
<br />SHUT-OFF VALVE
<br />IN VERTICAL LINE
<br />T & P RELIEF VALVE
<br />—O FCO
<br />FLOOR CLEANOUT
<br />_ _ O YCO
<br />YARD CLEANOUT
<br />-- WH
<br />WALL HYDRANT
<br />--- a_WCO
<br />WALL CLEANOUT
<br />FD FLOOR DRAIN HW HOT WATER
<br />DN DOWN CW COLD WATER
<br />VTR VENT THRU ROOF CONT. CONTINUATION
<br />U/G UNDER GROUND I.E. INVERT
<br />SAN SANITARY SEWER ELEVATION
<br />V PLUMBING VENT CD CONDENSATE
<br />DRAIN
<br />OUTSIDE
<br />INSIDE
<br />CORE DRILL WALL FOR EXISTING
<br />CIRCLE CUT NEW OR EXISTING STUD
<br />MASONRY OR CONCRETE
<br />CONSTRUCTION AND PROVIDE
<br />CONSTRUCTION
<br />GALVANIZED STEEL PIPE FOR 6" AND
<br />SMALLER. PROVIDE 10 GAUGE
<br />GALVANIZED SHEET STEEL ROUND TUBE
<br />FOR 6" AND LARGER. CAULK SLEEVE IN
<br />PROVIDE GALVANIZED STEEL PIPE WITH
<br />PLACE.
<br />RETAINING RING TO ANCHOR PIPE AND
<br />ACT AS A WATER STOP. GROUT IN PLACE
<br />FOR EXISTING MASONRY OR NEW
<br />PACK ANNULAR SPACE WITH
<br />CONCRETE CONSTRUCTION.
<br />FIBERGLASS INSULATION AND PROVIDE
<br />WATERPROOF NOW SHRINK SILICONE
<br />SEALANT ON INSIDE AND OUTSIDE
<br />PROVIDE CAST IRON WALL PIPE WITH
<br />4,
<br />FLUSH WITH WALL.
<br />RETAINING RING TO ANCHOR PIPE
<br />AND ACT AS A WATER STOP. POUR IN
<br />PLACE FOR NEW CONCRETE
<br />PROVIDE ESCUTCHEON FOR EXPOSED
<br />CONSTRUCTION.
<br />PIPE IN FINISHED SPACE
<br />NOTE:
<br />PIPING ARRANGEMENT SHOWN IN SCHEMATIC.
<br />ADJUST TO SUIT FIELD CONDITIONS.
<br />REFER TO SPECIFICATIONS FOR MORE INFORMATION ON INSULATION AND SEALANT.
<br />COORDINATE SLEEVE INSTALLATION WITH GENERAL CONTRACTOR.
<br />PIPING PENETRATION DETAIL
<br />5
<br />Scale: No Scale
<br />STUD IN WALL
<br />METAL CUP WITH (3) SHEET
<br />METAL SCREWS FASTENED
<br />TO BOTH STUDS
<br />WATER HEATER
<br />SHELF MOUNTED WATER HEATER
<br />STRAP TO WALL AS INDICATED.
<br />(1) STRAP ON THE UPPER 1/3 &
<br />(1) ON THE LOWER 1/3 MAINTAINING
<br />A MINIMUM OF 4" FROM CONTROLS.
<br />`- (2) SHEET METAL
<br />O O �SCREWS
<br />3/4" WIDE 20 GAUGE
<br />STRAP
<br />LATERAL SUPPORT
<br />WATER HEATER
<br />INSTALL WATER HEATER ABOVE
<br />MOP SINK UPON 8" 20 GA. STEEL
<br />STUD JOISTS SPACED 8" O.C.
<br />SPANNING SURROUNDING WALLS AT
<br />T-6" A.F.F. AT MOP SINK AND ABOVE
<br />CEILING AT HALLWAY. COORDINATE
<br />STRUCTURAL SUPPORT FRAMING
<br />WITH G.C.
<br />WATER HEATER SHELF DETAIL
<br />Scale: No Scale
<br />CONSULTANT:
<br />SEAL: HENRY D. MONTAGUE, PE 78172
<br />�111!!1
<br />� fit
<br />OtkpVA1. ����i�e�/
<br />E NSF .AlT9
<br />W No. 78172 '; m
<br />*" ATE OF �=
<br />LOR
<br />Zq-z/
<br />THP DRAWING SHALL NOT BE USED FOR
<br />CONSTRUCTION PURPOSES UNTIL THE SEAL AND
<br />SIGNATURE OF THE RESPONSIBLE REGISTRANT
<br />APPEARS ON THE DRAWING, AND PROPER PERMIT
<br />FORMS AND RELATED FEES ARE TRANSMITTED BY
<br />THE OWNER, OWNER'S AGENT OR CONTRACTOR
<br />TO THE AUTHORITY HAVING JURISDICTION.
<br />DATE
<br />ISSUED FOR
<br />REV
<br />03/29/2021
<br />PEMB COORDINATION
<br />05/20/2021
<br />CIVIL SUBMISSION
<br />05/20/2021
<br />DUKE COORDINATION
<br />06/07/2021
<br />PEMB COORDINATION 02
<br />08/09/2021
<br />CIVIL RESUBMISSION 1
<br />08/25/2021
<br />OWNER REVIEW
<br />1 1 /08/2021
<br />REVISED ELEVATIONS
<br />1 1 /29/2021
<br />PERMIT SUBMITTAL
<br />Project Manager
<br />Drawn
<br />L. LONG
<br />R. McCARTHY
<br />Project Leader
<br />Checked
<br />L. LONG
<br />H. MONTAGUE
<br />Date
<br />Dept Mgr Approval
<br />02/23/2021
<br />H. MONTAGUE
<br />Client
<br />PALMETTO ZEPHYRHILLS - GALL BLVD., LLC
<br />P.O. Box 1615,
<br />Thomasville, GA 31 799
<br />Office: (229) 226-1 1 77
<br />Contact: Daniel Tubb
<br />Project
<br />DOLLAR GENERAL
<br />Corner of Gall Boulevard and C
<br />Avenue,
<br />Zephyrhills, FL 33542
<br />(City of Zephyrhills)
<br />Store* 23227
<br />Drawing Title
<br />PLUMBING DETAILS
<br />AND DIAGRAMS
<br />DO NOT SCALE DRAWING
<br />Project No.
<br />Drawing No.
<br />.JCDT.20.0451
<br />P2