C <br />GENDER <br />NEUTRAL <br />HA1LW <br />07AY N <br />GFCI AN CONNECT TOUST <br />GENDER <br />NEUTRAL <br />SERVICE <br />CLOSE <br />BREAK <br />ROOM <br />OFFICE <br />AM 2 <br />4'-0" <br />AFF <br />3/4" PLYWOOD 12'-0" WIDE X 5'-5" HIGH, <br />FIRE RATED, NO VOIDS, PAINTED WHITE <br />UNLESS CODE DICTATES OTHERWISE. - <br />B/8 <br />/ROOM SENSOR LIGHT <br />CONTROL SWITCH. <br />B/2 <br />B/2 <br />B/8 <br />11 VA/ <br />sw <br />CA) <br />—WATER HEA ER 120V, <br />PROVIDE 1 POLE <br />TOGGLE SWITCH T <br />WATER HEATER <br />SEE SHEETS <br />E3 FOR <br />WIRING INFO. <br />SEE SHEET 2/E4 <br />FOR OFFICE <br />POWER PLAN & <br />DETAILS. <br />0 <br />12 AUTOMATIC DOOR, A/2. <br />DEDICATED WP/GFCI 20 <br />AMP OUTLET RECESSED <br />@ 4'-0" AFF FOR ICE <br />MERCHANDISER <br />6'-3" <br />V-8" .5 V-8" <br />6 <br />AM5,17,19 <br />A/27 � DD <br />RTU-3 5 5 <br />OL <br />SO CORD (WHITE), <br />ANCHOR TO PURLINS ABOVE. <br />A/27 SEE ARCHITECTURAL PLANS <br />r FOR DIMENSIONS (TYP). <br />B/3 <br />MEDIUM TEMP CASE <br />ROOF PENETRATIONS ARE TO BE REDUCED TO A <br />MINIMUM. CONTRACTOR TO RUN ALL CONDUITS <br />ALONG ROOF TO PARAPET WALL, TURN DOWN <br />INSIDE PARAPET WALL INTO SPACE BELOW. ALL <br />ROOF AND PARAPET WALL PENETRATIONS ARE TO <br />BE SEALED. ROOF PENETRATIONS TO BE <br />COORDINATED AND APPROVED BY DOLLAR <br />GENERAL PRIOR TO DOING ANY WORK. I <br />VERIFY ACTUAL HVAC <br />ELECTRICAL REQUIREMENTS <br />WITH MECHANICAL CONTRACTOR <br />SALES AREA <br />102 <br />39 <br />R/19 R/22,24 <br />O <br />A/7,9,11 <br />3 � <br />5 <br />O <br />RTU-2 <br />L <br />GC SHALL CONFIRM <br />POWER REQUIREMENTS <br />WITH REFRIGERATION <br />VENDOR PRIOR TO WORK. <br />LOW TEMP CASE <br />TYP. <br />T <br />ICE CREAM <br />FREEZER <br />CA E <br />10 7 <br />10 7 10 7 <br />10 7 10 7 <br />10 <br />8 10 8 10 8 <br />10 <br />9 <br />��❑ <br />3J <br />��� <br />5 7 J��❑ <br />w <br />11 J <br />❑� <br />,15 <br />J <br />1 <br />R/2 <br />3 J� <br />4J <br />�� <br />6 8J <br />�❑ <br />R/1 <br />12 J <br />R/1 ,16 J <br />NORTH <br />CX100 EMS PANEL FOR HVAC AND LIGHTING <br />CONTROL PANEL PURCHASED AND INSTALLED <br />BY THE ELECTRICAL CONTRACTOR. DOLLAR <br />GENERAL REFRIGERATION TEAM PROVIDES <br />12'-0" FINAL CONNECTION TO REFRIGERATION PANEL. <br />V-8" 1.8" 1'-8" / ..8" V-6" V-3" <br />PANEL PANEL PANEL EMS <br />A R B A/6 <br />(V <br />V <br />o F-1 DMARC 0 <br />0 <br />FLOOR LINE <br />DUPLEX RECEPTACLE <br />DEDICATED CIRCUIT A/4 <br />1 POWER PLAN <br />Scale. 1/8" = V-0" <br />REFRIGERATION CONTRACTOR PANEL. PROVIDE POWER <br />& DATA CONNECTIONS. POWER FROM CKT: R/41. <br />ELECTRICAL CONTRACTOR TO RUN AN EMPTY 1 "C. (WITH <br />PULL STRING) FROM THIS PANEL TO THE EMS PANEL. <br />REFRIGERATION CONTRACTOR TO PULL DATA LINE. <br />PROVIDED BY DOLLAR GENERAL REFRIGERATION TEAM. <br />TELEPHONE CONDUIT STUB THROUGH <br />WALL. SEE ELECTRICAL SPEC. NOTE H. <br />ELECTRICAL PANEL ELEVATION <br />Scale: NTS <br />BUZZER A/4 <br />RECEIVING <br />103 <br />TYP. <br />2 <br />6 <br />3 <br />A/1,3,5 <br />-U- <br />5 DD 4 <br />R/18,20 <br />R/17 <br />SEE 2/E1-- •- <br />REFRIGERATION <br />CONTACTOR PANEL <br />A/4 <br />V4' <br />COMMERCIAL <br />GRADE PUSH <br />UTTON <br />LEGEND <br />SYMB <br />DESCRIPTION <br />• <br />BUZZER - TORK MDL #TA725 W/ <br />TRANSFORMER MDL#TA592 <br />❑� <br />COMMERCIAL GRADE PUSH BUTTON <br />6A/23 <br />125V NEMA 5-20R DUPLEX. <br />PANEL/CIRCUIT IN PANEL <br />I}I <br />WU <br />125/250V NEMA L14-20-R 4 PRONG <br />TWIST LOCK <br />125V NEMA 5-20R QUAD <br />❑ <br />DISCONNECT <br />BLACK MAGIC POWER POLE <br />PHONE JACK <br />0 <br />RJ-11, RJ-45 DATA JACK, PHONE <br />COMBO <br />A/23 <br />PANEL/CIRCUIT IN PANEL <br />m <br />PROVIDE OCCUPANCY LIGHT <br />SENSOR- LEVITON ODS10-IDW <br />20 AMP TOGGLE SWITCH <br />NIL <br />NIGHT LIGHT CIRCUIT <br />GENERAL NOTES <br />A. MOUNT ALL REFRIGERATOR OUTLETS AT 12" AFF. <br />PANEL A <br />PANEL R <br />PANEL B <br />PANEL EMS <br />BRING RIGID PIPE SLEEVE <br />THROUGH BUILDING TO <br />ALLOW PHONE LINE <br />PENETRATION. SEAL ALL <br />PENETRATIONS. <br />ELECTRICAL KEYED NOTES <br />1. TEST/RESET STATION FOR STAND ALONE DUCT <br />DETECTOR. ONE FOR EACH DEVICE, SEE KEY NOTE 5 ON <br />THIS SHEET. SIMPLEX #4098-9842 IS SPECIFIED. WITH <br />PIEZO AND LED INDICATOR LIGHT. <br />2. MECHANICAL THERMOSTAT MOUNTED ON COLUMN AT 8'-0" <br />AFF. SURFACE MOUNT BOX AND CONDUIT. STUB CONDUIT <br />AT STRUCTURE. <br />3. LOCATIONS SHOWN FOR MECHANICAL UNITS ARE ONLY <br />APPROXIMATE, CONTRACTOR MUST CONSULT <br />MECHANICAL OR STRUCTURAL DRAWINGS TO DETERMINE <br />ACTUAL UNIT LOCATIONS. PROVIDE 1/2"C. PENETRATION <br />THRU ROOF WITHIN FOOTPRINT OF UNIT FOR USE WITH <br />CONTROL WIRING TO UNIT BY OTHERS. PROVIDE PROPER <br />WATERSEAL. (TYPICAL) <br />4. FACTORY MOUNTED POWERED CONVENIENCE OUTLET. <br />FIELD VERIFY THAT OUTLET IS POWERED, WIRE ALL WITH <br />THIS NOTE TO CIRCUIT R-26 IF THEY ARE NOT POWERED. <br />5. PHOTOELECTRIC DUCT DETECTOR WITH HOUSING. TIE TO <br />LED READOUT. STAND ALONE DEVICE, 120V. SIMPLEX <br />#4098-9687 IS SPECIFIED WITH 4098-9842 CONTROL <br />STATION. PROVIDE ONE DEVICE PER UNIT. MOUNT DEVICE <br />IN SUPPLY AIR DUCTWORK. DEVICE SHALL BE PROVIDED <br />AND WIRED TO THE CONTROL STATION BY THE <br />ELECTRICAL CONTRACTOR. HIRE THE MECHANICAL <br />CONTRACTOR FOR INSTALLATION IN DUCTWORK & <br />CONNECTION TO SHUTDOWN CONTROLS. ELECTRICAL <br />CONTRACTOR SHALL PROVIDE ALL REQUIRED RELAYS <br />AND 120V POWER, DO NOT POWER DUCT DETECTORS <br />FROM HVAC UNIT LOW VOLATGE. PLACE ANY REQUIRED <br />LABELING DIRECTLY BELOW UNIT. <br />6. MOUNT DISCONNECT SWITCH AT UNIT AS DESCRIBED IN <br />NOTE 1 ON HVAC UNIT WIRING TABLE SHEET E5. <br />7. PROVIDE 208V, 1 PHASE CONNECTION TO A J-BOX AT 90" <br />AFF WITH (3)#12 CU. & #12 GROUND IN 3/4"C. R.C. TO <br />PROVIDE AND INSTALL 30A/2NF DISCONNECT SWITCH AND <br />WIRE FROM DISCONNECT SWITCH TO EQUIPMENT <br />CONNECTIONS. <br />8. PROVIDE 208V, 1 PHASE CONNECTION TO A J-BOX AT 90" <br />AFF WITH (3)#8 CU. & #10 GROUND IN 1T. R.C. TO PROVIDE <br />AND INSTALL 60A/2NF DISCONNECT SWITCH AND WIRE <br />FROM DISCONNECT SWITCH TO EQUIPMENT <br />CONNECTIONS. <br />9. PROVIDE 208V, 1 PHASE CONNECTION TO A J-BOX AT 90" <br />AFF WITH (3)#10 CU. & #10 GROUND IN 3/4"C. R.C. TO <br />PROVIDE AND INSTALL 30A/2NF DISCONNECT SWITCH AND <br />WIRE FROM DISCONNECT SWITCH TO EQUIPMENT <br />CONNECTIONS. <br />10. MOUNT J-BOX 11" FROM THE RIGHT SIDE OF EACH UNIT. <br />CONFIRM EXACT LOCATION WITH REFRIGERATION <br />VENDOR PRIOR TO WORK (TYP). <br />11. VACANCY SENSOR. SENSOR SHALL CONTROL LIGHTS AND <br />TOP HALF OF THE DUPLEX RECEPTACLES INDICATED AS <br />SPLIT WIRED, (13/2). <br />12. SPLIT WIRED RECEPTACLES. CIRCUIT B/8 SHALL BE <br />'ALWAYS ON', CIRCUIT B/2 SHALL BE CONTROLLED BY THE <br />VACANCY SENSOR. RECEPTACLE SECTIONS THAT ARE <br />AUTOMATICALLY CONTROLLED SHALL BE PERMANENTLY <br />MARKED PER ASHRAE STANDARDS. <br />CONSULTANT: <br />SEAL: SEAN PATRICK PIC-KELL, PE 83946 <br />\`\�QA�F0CK p/" ,,��/ <br />`ZP\GEN8�' <br />., <br />0 = NO.83946 <br />STATE OF <br />SS <br />I filll <br />THIS DRAWING SHALL NOT BE USED FOR <br />CONSTRUCTION PURPOSES 'UNTIL THE SEAL AND <br />SIGNATURE OF THE RESPONSIBLE REGISTRANT <br />APPEARS ON THE DRAWING, AND PROPER PERMIT <br />FORMS AND RELATED FEES ARE TRANSMITTED BY <br />THE OWNER, OWNER'S AGENT OR CONTRACTOR <br />TO THE AUTHORITY HAVING JURISDICTION. <br />DATE <br />ISSUED FOR <br />REV <br />03/29/2021 <br />PEMB COORDINATION <br />05/20/2021 <br />CIVIL SUBMISSION <br />05/20/2021 <br />DUKE COORDINATION <br />06/07/2021 <br />PEMB COORDINATION 02 <br />08/09/2021 <br />CIVIL RESUBMISSION 1 <br />08/25/2021 <br />OWNER REVIEW <br />1 1 /08/2021 <br />REVISED ELEVATIONS <br />1 1 /29/2021 <br />PERMIT SUBMITTAL <br />Project Manager <br />Drawn <br />L. LONG <br />N. NGUYEN <br />Project Leader <br />Checked <br />L. LONG <br />M. GOOD <br />Date <br />Dept Mgr Approval <br />02/23/2021 <br />M. GOOD <br />Client <br />PALMETTO ZEPHYRHILLS - GALL BLVD., LLC <br />P. 0. Box 1615, <br />Thomasville, GA 31 799 <br />Office: (229) 226-1 1 77 <br />Contact: Daniel Tubb <br />Project <br />DOLLAR GENERAL <br />Corner of Gall Boulevard and C <br />Avenue, <br />Zephyrhills, FL 33542 <br />(City of Zephyrhills) <br />Store #: 23227 <br />Drawing Title <br />POWER PLAN <br />DO NOT SCALE DRAWING <br />Project No. <br />Drawing No. <br />JCDT.20.0451 <br />E1 <br />