EXTERIOR FINISHES <br />TAG <br />MATERIAL <br />MANUFACTURER <br />COLOR / STYLE <br />GENERAL REMARKS <br />A❑ <br />FIBER CEMENT PANELS <br />NICHIHA WALL PANELS <br />ROUGHSAWN / ESPRESSO <br />OSTUCCO <br />WALL SYSTEM <br />GC TO SELECT FROM APPROVED VENDORS <br />SHERWIN WILLIAMS SW #6149 "RELAXED KHAKI" <br />O <br />SPANDREL GLAZING <br />GC TO SELECT FROM APPROVED VENDORS <br />DARK BRONZE <br />ALUMINUM FRAME <br />OD <br />STUCCO (CORNICE) <br />GC TO SELECT FROM APPROVED VENDORS <br />SHERWIN WILLIAMS SW #6385 "DOVER WHITE" <br />OSTUCCO <br />(ACCENT BANDING) <br />GC TO SELECT FROM APPROVED VENDORS <br />SHERWIN WILLIAMS SW #6385 "DOVER WHITE" <br />O <br />METAL CANOPY <br />GC TO SELECT FROM APPROVED VENDORS <br />PAINT SHERWIN WILLIAMS SW #7055 "ENDURING BRONZE" <br />ODOWNSPOUTS <br />PROVIDED BY GC <br />PAINT SHERWIN WILLIAMS SW #7055 "ENDURING BRONZE" <br />OSTANDARD <br />METAL ROOF PANELS <br />PEMB MANUFACTURER <br />GALVALUME <br />PBR ROOF PANELS W/ ATLAS ULTIMATE FASTNER <br />OREAR <br />BUILDING PARAPET WALL <br />PEMB MANUFACTURER <br />SANDSTONE <br />O <br />STOREFRONT SYSTEM <br />REF PRODUCT APPROVAL ON COVER SHEET <br />DARK BRONZE <br />ALUMINUM FRAME <br />OPREFINISHED <br />METAL COPING @ PARAPET <br />REF PRODUCT APPROVAL ON COVER SHEET <br />BURNISHED SLATE <br />OHOLLOW <br />METAL DOOR / FRAME <br />REF PRODUCT APPROVAL ON COVER SHEET <br />SHERWIN WILLIAMS SW #7055 "ENDURING BRONZE" <br />OSTUCCO <br />WALL SYSTEM <br />GC TO SELECT FROM APPROVED VENDORS <br />SHERWIN WILLIAMS SW #7055 "ENDURING BRONZE" <br />T/O PARAPET <br />21'-0" AFF <br />T/O PARAPET <br />19'-0" AFF <br />_J4 FINISH FLOOR <br />0'-0,. <br />21'-0" AFF <br />T/O GLAZING <br />19'-4" <br />SILL HEIGHT <br />T/O GLAZING <br />FINISH FLOOR <br />0'-0" <br />T/O SIDEWALK <br />-2'-0" REF. CIVI <br />D 4" TYP. <br />a <br />00 z <br />ch z•E' zzI ,.zzz' ,1.�•,.. <br />o <br />M <br />CD <br />LL <br />OA3b <br />io <br />L <br />r <br />A <br />E <br />0 <br />5 <br />A3b <br />5 WINDOW ELEVATION <br />Scale. 1/8 = i -0 <br />,zz,,z. zzzzz.zzzz•,z zf' <br />Y,. <br />. <br />OPENING IN WALL PANEL <br />FOR DRAINAGE TO <br />GUTTER (TYP.) <br />(COORDINATE WITH <br />PEMB) <br />I V IVI'F lJti I tit I.VLUK <br />A B C D D C OF THE BUILDING B A <br />1 2 <br />(i) [ <br />❑ 1 3 A3b \ 1, 4'-5%2' A3b I &. t 3 ❑ 3 '. T/O PARAPET <br />zz z z' <br />OPENING IN WALL PANEL <br />FOR DRAINAGE TO <br />GUTTER (TYP.) <br />(COORDINATE WITH <br />PEMB) <br />I V IVI'F lJti I tit I.VLUK <br />A B C D D C OF THE BUILDING B A <br />1 2 <br />(i) [ <br />❑ 1 3 A3b \ 1, 4'-5%2' A3b I &. t 3 ❑ 3 '. T/O PARAPET <br />zz z z' <br />z z z z z <br />,zzzz ' <br />,zzzz ' <br />,zzzz'zz <br />zzzz', <br />zz <br />,zzzz <br />z.:C z <br />zzzz'zzzz' <br />,;,, <br />dk <br />WEST ELEVATION U-' <br />Scale: 1/8" = V-0" <br />z❑ z,zzz,zzzz',zzzz' <br />z i z z i i' ,zzzz ' ,zzzz <br />,zzzz ' <br />z z z z z <br />,zzzz ' <br />C <br />,zzzz ' <br />,zzzz ' <br />,zzzz ' <br />z z z z z <br />,zzzz ' <br />,zzzz ' <br />,zzzz ' <br />z z <br />,zzzz <br />,zzzz ' <br />z z <br />z',zz'zzci' <br />zz• <br />n5 <br />1 nn A TIr%kl nr T[1l nl AMI <br />.......... <br />REFERENCE CIVIL — <br />DRAWINGS FOR <br />SIDEWALK GRADING <br />INFORMATION <br />T/O PARAPET <br />21'-0" <br />T/O PARAPET <br />FINISH FLOOR <br />T/r1 DADADGT <br />GENERAL NOTES: <br />1 . ALL EXTERIOR SIGNAGE SHALL BE <br />SUBMITTED UNDER SEPARATE PERMIT. <br />2. PROVIDE KNOX BOX WHERE REQUIRED BY <br />JURISDICTION PURCHASED FROM LOCAL <br />FIRE DEPARTMENT. MOUNT PER FIRE <br />DEPARTMENT REQUIREMENTS ON WALL <br />ADJACENT TO ENTRANCE ON RIGHT SIDE. <br />3. PROVIDE AND INSTALL BUILDING <br />ADDRESS ON EXTERIOR ELEVATION <br />FACING STREET WITH LETTER VISIBLE <br />FROM STREET PER 2017 FLORDIA FIRE <br />PREVENTION CODE AND NFPA 1, <br />UNIFORM FIRE CODE. <br />4. PEMB MANUFACTURER SHALL PROVIDE <br />ALL METAL FRAMING, REAR PANELS, <br />CRICKETS, AND REQUIRED FLASHING <br />FOR ANY AND ALL PARTS OF THE RAISED <br />PARAPET AND PILASTERS ABOVE THE <br />ROOF LINE - TYP. <br />9 <br />M <br />N <br />FINISH <br />0'-0" <br />KEYED NOTES <br />t GC SHALL COORDINATE THE EXTERIOR CANOPY SIGN <br />WITH DOLLAR GENERAL CORP. GC TO PROVIDE ADEQUATE <br />BLOCKING AS REQUIRED BY SIGN MANUFACTURER TO <br />SUPPORT SIGN WEIGHT (MAX 1,400 LBS) AND SHALL BE <br />SUPPORTED BY CANOPY FACE. GC TO PROVIDE CIRCUIT <br />AS NOTED ON ELECTRICAL PLAN. SIGN TO BE PROVIDED <br />AND INSTALLED BY DOLLAR GENERAL CORP. INSTALL <br />BUILDING SIGN CENTERED ON FRONT ELEVATION. <br />❑ROOF ACCESS LADDER (COORDINATE FASTENING <br />SUPPORTS WITH PEMB). <br />❑FLOOD LIGHT. REFER TO ELECTRICAL DRAWINGS FOR <br />ADDITIONAL INFORMATION. <br />❑LINE OF PRE -FINISHED METAL ROOF BEYOND <br />(REF EXTERIOR FINISH SCHEDULE THIS SHEET) <br />(4) 1/2" DIA X 6" LG STAINLESS STEEL EYE BOLTS (CLOSED) <br />❑ WITH 1" DIA OPENING - DRILL AND EPDXY INTO BLOCK <br />WALL <br />EXTERIOR RECEPTACLE. RE: ELECTRICAL <br />❑WALL PACK. REFER TO ELECTRICAL DRAWINGS <br />FOR ADDITIONAL INFORMATION. <br />❑EMERGENCY EGRESS LIGHT - REFER TO ELECTRICAL <br />DRAWINGS. <br />❑9 DOOR BUZZER <br />t o MECHANICAL VENT - REFER TO MECHANICAL DRAWINGS. <br />t t PLUMBING VENT - REFER TO PLUMBING DRAWINGS. <br />12 WALL HYDRANT. RE: PLUMBING <br />ROOF MOUNTED HVAC UNITS ON PRE FABRICATED ROOF <br />t 3 CURB (REF SHEET M1) <br />❑OUTSIDE AIR TEMP. SENSOR MOUNTED OVER RECEIVING <br />t 4 DOORS @ 8'-0" A.F.F. <br />15 GC SHALL COORDINATE THE EXTERIOR BLADE SIGN WITH <br />DOLLAR GENERAL CORP. <br />CONSULTANT: <br />SEAL: JOHN BENEDICT POLSINELLI, AR96059 <br />09 <br />A OF <br />Fto <br />�:9® �BENEDICTPOLSINZ4�P."� <br />AR99059 <br />���'`taaae ae eeaa' ' <br />THIS DRAWING HALL NOT BE USED FOR <br />CONSTRUCTION PURPOSES UNTIL THE SEAL AND <br />SIGNATURE OF THE RESPONSIBLE REGISTRANT <br />APPEARS ON THE DRAWING, AND PROPER PERMIT <br />FORMS AND RELATED FEES ARE TRANSMITTED BY <br />THE OWNER, OWNER'S AGENT OR CONTRACTOR <br />TO THE AUTHORITY HAVING JURISDICTION. <br />DATE <br />ISSUED FOR <br />REV <br />03/29/2021 <br />PEMB COORDINATION <br />05/20/2021 <br />CIVIL SUBMISSION <br />05/20/2021 <br />DUKE COORDINATION <br />06/07/2021 <br />PEMB COORDINATION 02 <br />08/09/2021 <br />CIVIL RESUBMISSION 1 <br />08/25/2021 <br />OWNER REVIEW <br />1 1 /08/2021 <br />REVISED ELEVATIONS <br />1 1 /29/2021 <br />PERMIT SUBMITTAL <br />Project Manager <br />Drawn <br />L. LONG <br />S. KORTMAN <br />Project Leader <br />ed <br />Checked <br />k <br />L. LONG <br />Date <br />Dept Mgr Approval <br />g pp <br />02/23/2021 <br />Client <br />PALMETTO ZEPHYRHILLS - GALL BLVD., LLC <br />P.O. Box 1615, <br />Thomasville, GA 31 799 <br />Office: (229) 226-1 177 <br />Contact: Daniel Tubb <br />Project <br />DOLLAR GENERAL <br />Corner of Gall Boulevard and C <br />Avenue, <br />Zephyrhills, FL 33542 <br />(City of Zephyrhills) <br />Store #: 23227 <br />Drawing Title <br />EXTERIOR ELEVATIONS <br />DO NOT SCALE DRAWING <br />Project No. <br />Drawing No. <br />,JCDT.20.04S 1 <br />A2 <br />��� I mo- I if 1 - I - - - - - - - --i — - _R <br />