ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />--------------------------------------------- <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />taps and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />i <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />FEF <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />rqiw- <br />HALF-SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />r' <br />WALL SWITCH <br />C3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />200A <br />INDOOR PANEL <br />CENTER <br />10 #14 copper to lights & outlets <br />7 <br />00 AMP <br />200 <br />912 copper to 20 amp ckts <br />ti10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />MAIN <br />U2/0 <br />ar <br />4/0 SER Alu <br />200 amp <br />150 amp <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />Q <br />EXHAUST FAN <br />GFI <br />IV <br />FI <br />' <br />- <br />ELECTRICAL PANEL <br />M <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />VERIFY METER <br />CH <br />❑ <br />(OPTIONAL) <br />CHIMES OPTIONAL <br />HOOD PER SPECS <br />LOCATION WITH <br />BUILDER <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />a <br />TELEVISION (OPTIONAL) <br />a 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />_Q <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />U � <br />C , CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR GOPT. CEILING FAN MAIN FLOOR ELECTRICAL PLAN <br />J <br />EM) (1) PHONE LINE, (1) DATA PORT <br />SCALE: %4"=1'-0" <br />CD rrn <br />M <br />O <br />N <br />� QQQ <br />Cl- <br />71 <br />0 <br />C <br />nV)n' <br />LU <br />O LU <br />E <br />0 <br />ZD <br />to <br />i� Cn <br />0 <br />V <br />N M <br />LU <br />�_... -• F— E <br />C CIO M <br />[2 p N <br />O <br />J✓ LL Co <br />Co <br />WQCD <br />CD <br />� Y <br />rn <br />u7 O <br />M Q o <br />N�wC�S C <br />� <br />N <br />N <br />zi;�? <br />N <br />m <br />y <br />Z O7 <br />itz 44 0 0 <br />C1 <br />J Cj <br />Z � MNtiZ 'ham-' <br />o <br />Z <br />tJi <br />N .o <br />�MN <br />L.0 <br />�w <br />�W <br />Z p¢� Q <br />W oho <br />E?Z <br />m m <br />LLN <br />W N <br />O U <br />U <br />To the best ofthe Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />O <br />Z N <br />O cu <br />4E j O <br />I�+(nM0 <br />M <br />Q U-) 170 Ln <br />4. V)Z <br />Ln <br />a) - to <br />a <br />Z <br />� �M <br />tY U a OC) <br />Q . <br />E <br />Z <br />WJ <br />l:0 <br />'d- <br />J <br />oZ <br />Uo <br />za <br />�F <br />Z <br />a a w <br />Uz�0 <br />J <br />Zdwx <br />Z Z <br />^ <br />LL <br />l— <br />TOWZ <br />YaLu <br />Or n <br />QUU <br />u <br />W <br />N caZo <br />r <br />Zo <br />�z <br />-aJ <br />w <br />Z <br />W <br />> <br />Lr) <br />Cc: <br />a <br />0 <br />Q <br />O <br />N <br />J <br />JLij <br />J <br />Lu <br />o2� <br />QX <br />U <br />Z <br />Uam2 <br />Q <br />O ¢ O <br />cJ� <br />Z <br />tC'eie Q J <br />N <br />o Zoe <br />W <br />Ln <br />a <br />J <br />,--I <br />Ll J <br />di <br />Q <br />o Z o <br />Pia <br />W~ <br />O <br />I- <br />Q <br />Z <br />d�z <br />to <br />Z <br />a � <br />O <br />Z <br />IW <br />� o <br />aw <br />O <br />0 <br />g <br />= <br />r-, <br />,--1 <br />a <br />cn <br />SCALE : AS NOTED <br />DATE : 1 /5/2018 <br />TECH: MJAM ES <br />VERSION NO. <br />12.0 <br />SHEET NO. <br />4.0 <br />