My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6594 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6594 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 6:31:10 PM
Creation date
2/19/2025 2:49:52 PM
Metadata
Fields
Template:
Building Plans
Street #
6594
Location
Wagon Trail St
Contractor
Lennar Homes LLC
Building Plans - Permit #
19510
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ar4-11AN �u■wnw��m� <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights B outlets <br />7 <br />00 AMP <br />200 <br />10 #12 copper to 20 amp ckis <br />10 #10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />MAIN <br />O2I0 <br />or <br />410 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED----_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />----------------------------------------------- <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station cc alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14, Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />' <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />f� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />Q EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />O PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />©2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />]M ELECTRIC METER <br />Owl_ ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />FC.. , .�, ...... <br />SYSTEM <br />-- T—'I <br />I I <br />L — <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />r—i <br />I I <br />UPPER ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />u <br />UI7 <br />z M <br />— 0 <br />o <br />z� <br />Q <br />J <br />a <br />CL^n, (D <br />� cs3 <br />w <br />Q <br />�U — <br />w <br />O <br />~ <br />0 <br />= <br />co <br />C/) <br />o <br />U <br />0Mcz M <br />W <br />'— E <br />I— (0 c) <br />N <br />— o <br />O o <br />_ <br />(� 00 <br />wKo <br />Qm <br />O 7 <br />MQo <br />iD® <br />NNC �Y <br />C <br />22 <br />� <br />as f N <br />co <br />� N <br />rn <br />YI o o N o N <br />o00 <br />Z o <br />Z LU <br />� ? <br />LU �M N <br />c it •o <br />w <br />a <br />W <br />0Z < <br />5 z <br />O-o �� <br />�� <br />��a <br />t/f " E cp <br />m m <br />LLW 'a <br />o <br />W W¢Nw <br />-' <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />0 <br />Z N <br />O (3) <br />'—' ;L O <br />> (n M O <br />M <br />Q U <br />� <br />� <br />0Z <br />Q � tl- <br />F- �" M <br />� V a� <br />Q �00 <br />Z <br />W <br />J� <br />d" <br />oZ <br />Lu <br />Z d <br />f a <br />I-- <br />z <br />w¢�� <br />Q <br />oQ-o <br />Z u1- lY <br />��zz <br />J°�L9 <br />0 ' 0 <br />Sao <br />CU <br />Lu <br />Z <br />Zo <br />Z <br />0 <br />W <br />Zo <br />n3 <br />ro <br />w <br />0 <br />0 <br />> <br />Ln <br />cr <br />Z <br />Q <br />O <br />¢ <br />�� <br />U <br />N <br />p <br />>� <br />a <br />y <br />0 <br />J <br />V— <br />a�¢0 <br />A <br />J <br />Uama <br />CAV <br />Q <br />oao¢ <br />1` <br />w W Z Q <br /><a <br />Q <br />N <br />o�� <br />Z <br />u Q <br />Z <br />fV <br />LLJW�Z <br />W <br />Lr) <br />W <br />=¢�o <br />J <br />rl <br />Uj <br />(nOZU <br />o¢~ <br />Cr' <br />Q <br />Z <br />Q�z <br />Ln <br />ZZLij <br />tj <br />Z <br />111 <br />O <br />06 <br />_I <br />Z:¢ <br />n <br />ri <br />a <br />Lf) <br />SCALE : AS NOTED <br />DATE : 1 /5/2018 <br />TECH: MJAM ES <br />VERSION NO- 10 <br />SHEET NO. <br />4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.