N <br />0 <br />T_ <br />O <br />T <br />T <br />N <br />N <br />O <br />N <br />00 <br />Notes: <br />Branch Panel: C <br />Location: <br />Supply From: <br />Mounting: Recessed <br />Enclosure: Type 1 <br />Volts: 120/240 Single <br />Phases: 1 <br />Wires: 3 <br />A.I.C. Rating: 10,000 <br />Mains Type: MLO <br />Mains Rating: 150 A <br />MCB Rating: 150 A <br />CKT <br />Circuit Description <br />Trip <br />Poles <br />A <br />B <br />Poles <br />Trip <br />Circuit Description <br />CKT <br />1 <br />EX CKT <br />20 A <br />1 <br />0 VA <br />0 VA <br />1 <br />20 A <br />EX CKT <br />2 <br />3 <br />EX CKT <br />20 A <br />1 <br />0 VA <br />0 VA <br />1 <br />20 A <br />EX CKT <br />4 <br />5 <br />EX CKT <br />20 A <br />1 <br />0 VA ' <br />0 VA <br />1 <br />20 A <br />EX CKT <br />6 <br />7 <br />EXISTING RECEPTACLES <br />20 A <br />1 <br />1080 VA <br />' 0 VA <br />1 <br />20 A <br />EX CKT <br />8 <br />9 <br />EX CKT <br />20 A <br />1 <br />0 VA <br />0 VA <br />1 <br />20 A <br />EX CKT <br />10 <br />11 <br />EXIST HVAC CKT <br />45 A <br />2 <br />0 VA <br />0 VA <br />2 <br />30 A <br />EXIST WH <br />12 <br />13 <br />-- <br />-- <br />-- <br />0 VA <br />0 VA <br />-- <br />-- <br />-- <br />14 <br />15 <br />EX CKT <br />20 A <br />1 <br />0 VA <br />800 VA <br />1 <br />20 A <br />REFRIGERATOR <br />16 <br />17 <br />EXIST CONF ROOM LTG CKT <br />20 A <br />1 <br />800 VA <br />600 VA <br />1 <br />20 A <br />PHARMACY UC REF <br />18 <br />19 <br />PHARMACY RECEP <br />20 A <br />1 <br />360 VA <br />540 VA <br />1 <br />20 A <br />PHARMACY RECEP <br />20 <br />21 <br />PHARMACY RECEP <br />20 A <br />1 <br />720 VA <br />900 VA <br />1 <br />1 <br />20 A I <br />PHARMACY RECEP <br />22 <br />23 <br />PHARMACY RECEP <br />20 A <br />1 <br />1 <br />1720 VA <br />0 VA <br />-- <br />-- <br />Space <br />24 <br />Total Load: <br />Total Amps: <br />2990 VA <br />25 A <br />3500 VA <br />29 A <br />Legend: <br />Load Classification <br />Connected Load <br />Demand Factor <br />Estimated Demand <br />Panel Totals <br />Receptacle <br />4320 VA <br />100.00% <br />4320 VA <br />Power <br />1400 VA <br />100.00% <br />1400 VA <br />Total Conn. Load: <br />6485 VA <br />Lighting <br />800 VA <br />125.00% <br />1000 VA <br />Total Est. Demand: <br />6677 VA <br />Total Conn.: <br />27 A <br />Total Est. Demand: <br />28 A <br />Notes: PROVIDE ADDITIONAL BRANCH CIRCUIT BREAKERS TO MATCH EXISTING FOR CIRCUITS 16, 18, 19, 20, 21, 22 AND 23. <br />YWAP f <br />ELECTRICAL PLAN <br />1 /4" = 1 '-0" <br />C-23 <br />LC <br />�m � ` <br />C-22(D <br />PULI MIDC no I n\A/ Wnl TA(-C <br />CAB <br />REC <br />TYPICAL FOR FLOOR PLAN DESIGNATION <br />LOW VOLTAGE BACKBOX AND RACEWAY DETAIL <br />1211 = 1'-0" <br />rl rP1Tr11/'1 A 1 IZr\/A 1/1Tre1 <br />- C L_ C V I rl I V t_% L_ r\ IE= T I V lJ I C J <br />OEXISTING PANEL. PROVIDE ADDITIONAL 20A/1 P CIRCUIT BREAKERS TO MATCH EXISTING. <br />OEXISTING RECEPTACLE TO REMAIN. <br />OMAINTAIN AND RELOCATE EXISTING LIGHTING CONTROLS. <br />- r vvv L__n <br />SINGLE RECEPTACLE <br />DUPLEX RECEPTACLE <br />n <br />DUPLEX RECEPTACLE -GFCI <br />DUPLEX RECEPTACLE - GFCI W/ WEATHERPROOF IN USE COVER <br />0 <br />D� <br />DUPLEX RECEPTACLE - ABOVE SHOW WINDOW <br />DOUBLE DUPLEX RECEPTACLE <br />n <br />DOUBLE DUPLEX RECEPTACLE - GFCI <br />DOUBLE DUPLEX RECEPTACLE FLOOR BOX <br />DUPLEX RECEPTACLE FLOOR BOX <br />C <br />DUPLEX RECEPTACLE CEILING MOUNTED <br />aDATA <br />OUTLET <br />FZ)] <br />DATA OUTLET- FLOOR BOX <br />$ LV <br />LOW VOLTAGE DIGITAL DIMMING SWITCH <br />$ OS <br />WALL BOX LINE VOLTAGE OCC SENSOR DIMMING SWITCH <br />$ M(P) <br />FRACTIONAL HORSEPOWER MANUAL MOTOR STARTER WITH <br />OVERLOADS FOR MOTOR ("P" INDICATES PILOT LIGHT) <br />OS <br />CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR <br />OS <br />WALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR <br />DISCONNECT SWITCH - NONFUSED <br />DISCONNECT SWITCH - FUSED <br />MOTOR STARTER - COMBINATION TYPE C/B WITH CIRCUIT <br />SIZE AND <br />BREAKER, F = FUSED SWITCH, NF = NONFUSED <br />No. OF <br />DISCONNECT SWITCH <br />POLES <br />B <br />ENCLOSED CIRCUIT BREAKER TYPE DISCONNECT SWITCH <br />INDICATED <br />ON PLANS <br />Z (P) <br />MANUAL MOTOR STARTER (1 HP AND ABOVE) <br />("P" INDICATES PILOT LIGHT) <br />MAGNETIC CONTACTOR OR MOTOR STARTER <br />WAPaWIRELESS <br />ACCESS POINT DATA OUTLET <br />aDATA <br />OUTLET WITH TWO CABLING DROPS <br />TV <br />TELEVISION OUTLET (CATV, MATV, SATV) AS INDICATED <br />PUSH-BUTTON STATION SINGLE <br />WM <br />SURFACE MOUNTED RACEWAY -WI REMOLD OR EQUAL <br />CONDUIT HOMERUN ARROW INDICATES CONDUIT AND WIRE TO BE RUN <br />TO PANEL AS INDICATED (AMOUNT OF ARROWHEADS = AMOUNT <br />OF CIRCUITS) <br />PE <br />PHOTO ELECTRIC CELL <br />SPECIAL RECEPTACLE- TYPE AS NOTED <br />JUNCTION BOX - SIZE AS REQUIRED <br />T❑ <br />TRANSFORMER - SIZE AS INDICATED ON PLAN <br />TC <br />TIME CLOCK <br />MOUNTING HEIGHTS <br />1. ALL MOUNTING HEIGHTS LIST ARE TO CENTER OF DEVICE UNLESS <br />OTHERWISE NOTED AND MUST CONFORM TO ADA, NFPA, ANSI 117.1 <br />REQUIREMENTS UNLESS OTHERWISE NOTED. <br />2. CONTRACTOR TO VERIFY FINAL LOCATION OF ALL DEVICES WITH <br />ARCHITECT AND/OR INTERIOR DESIGNER. <br />3. WHERE DEVICES FALL ON TWO SURFACE FINISHES, RAISE THE <br />DEVICE TO BE ON A SINGLE FINISH. COORDINATE WITH ARCHITECT. <br />FIRE ALARM GONG AND BELL <br />6-8" MAX. HT. OR 6" BELOW CLG. WHICHEVER <br />(WALL MOUNTED) <br />IS LOWER <br />FIRE ALARM STROBE LIGHT & SIGNALING <br />ENTIRE LENS IS NOT LESS THAN 80" AND <br />DEVICES <br />NOT GREATER 96" AFF. WHERE LOW <br />(WALL MOUNTED) <br />CEILINGS DO NOT PERMIT MOUNTING AT <br />MIN. 80", DEVICE SHALL BE MOUNTED <br />WITHIN 6" OF THE CEILING. <br />TOP OF LIGHTING AND/OR POWER PANELS <br />IN COMMON BUILDING SPACES TOP OF <br />6'- 2" AFF <br />TELEPHONE CABIN ET(MAXIMLIM) <br />TOP OF LIGHTING AND/OR POWER PANELS <br />4'- 6" AFF TO HIGHEST OPERABLE DEVICE <br />IN LIVING UNITS <br />LIGHTING SWITCH <br />46" AFF TO CENTERLINE <br />TOP OF BACK MOUNTED EXIT FIXTURE <br />12" BELOW FINISHED CEILING TO CENTERLINE <br />(NOT LOCATED ABOVE DOORS) <br />TOP OF SAFETY DISCONNECT SWITCH, <br />6'- 0" MAXIMUM AFF <br />CONTACTORS, MAGNETIC MOTOR STARTERS <br />++' <br />6" BELOW FINISHED CEILING <br />+' <br />4'- 0" AFF OR 6" ABOVE COUNTER <br />BELOW COUNTER <br />MANUAL CONTROL DEVICES, <br />T- 6" AFF <br />FIRE ALARM PULL STATION, FIRE PHONE <br />JACKS <br />RECEPTACLES, TELEPHONE OUTLETS (DESK) <br />1'- 6" AFF <br />COMPUTER OUTLETS <br />TELEVISION OUTLETS <br />REFER TO ARCHITECTURAL DRAWINGS <br />FINISHED FLOOR ELEV. (BASE) - <br />0' - 0" <br />- ELECTRICAL GENERAL NOTES <br />1. DO NOT SCALE FROM THESE DRAWINGS. <br />2. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE LOCAL AHJ, <br />2017 NATIONAL ELECTRICAL CODE (NEC), 2020 FLORIDA BUILDING CODE (FBC) <br />7TH EDITION, AND ALL OTHER APPLICABLE BUILDING CODES. <br />3. ELECTRICAL CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER TRADES <br />TO ASSURE PROPER CLEARANCES FOR EQUIPMENT AND TO KEEP THE JOB <br />PROGRESSING. <br />4. REFER TO MECHANICAL DRAWINGS FOR INTERLOCKING REQUIREMENTS OF <br />MECHANICAL EQUIPMENT (MOTORS, FANS, PUMPS, ETC...). INSTALL ANY <br />ELECTRICAL EQUIPMENT (STARTERS, RELAYS, VFD'S, ETC..) FURNISHED BY DIV. <br />15 OR OWNER. <br />5. ALL CEILING MOUNTED ITEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />ARCHITECTURAL REFLECTIVE CEILING PLANS. IF LOCATION FOR AN ITEM IS NOT <br />SHOWN ON THE ARCHITECTURAL REFLECTIVE CEILING PLANS, VERIFY THE <br />EXACT LOCATION OF THE ITEM WITH THE ARCHITECT PRIOR TO INSTALLATION. <br />THESE REQUIREMENTS APPLY TO ALL CEILING TYPES IN ALL AREAS. <br />6. WHERE NON -FUSED DISCONNECT IS NOT PROVIDED "WITHIN SIGHT" OF MOTOR <br />(OR HEATER UNIT). FEEDER (AND/OR BRANCH CIRCUIT) OVER -CURRENT DEVICE <br />SERVING SUCH MOTOR (OR HEATER) SHALL HAVE APPROVED "LOCKED -OFF" <br />PROVISION. <br />7. PROVIDE WALL SWITCHES AND/OR MOTION SENSORS IN EACH OFFICE/AREA TO <br />CONTROL THE LIGHT FIXTURE(S) IN EACH OFFICE/AREA. <br />8. REFERENCE MECHANICAL DRAWINGS FOR ALL MECHANICAL EQUIPMENT <br />NEEDING ELECTRICAL CONNECTIONS. MAKE ALL CONNECTIONS AND PROVIDE <br />APPROPRIATE WIRE CONDUIT AND OVERCURRENT PROTECTION FOR ALL <br />EQUIPMENT. COORDINATE EXACT REQUIREMENTS WITH MECHANICAL <br />CONTRACTOR. <br />9. PROVIDE EXIT SIGNAGE AT ALL EXITS AND EGRESS PATHS AS REQUIRED OR AS <br />SHOWN ON LIFE SAFETY PLANS. <br />10. ALL EXTERIOR WIRING DEVICES TO BE WEATHERPROOF AND GROUND <br />FAULT INTERRUPTING TYPE RECEPTACLES. <br />11. REFER TO ARCHITECTURAL FLOOR PLANS FOR DIMENSIONAL LOCATIONS OF ALL <br />FLOOR MOUNTED ELECTRICAL DEVICES. <br />12. CONDUIT RUNS SHOWN ARE DIAGRAMMATIC IN NATURE. CONTRACTOR IS <br />RESPONSIBLE FOR SIZING AND LOCATING PULL BOXES PER NEC AND FOR <br />COORDINATION WITH OTHER DISCIPLINES. <br />13. COORDINATE EXACT LOCATIONS OF ALL ITEMS INSTALLED ON SITE WITH CIVIL <br />ENGINEER. <br />14. COORDINATE ALL LOCATIONS OF RECEPTACLES AND SYSTEMS OUTLETS WITH IN <br />ALL CASEWORK. WIRE TYPE THHN/THWN, MINIMUM SIZE #12. <br />15. USE No. 10 AWG CU. CONDUCTORS FOR 20 AMPERE, 277 VOLT BRANCH CIRCUITS <br />LONGER THAN 200 FEET. (MAXIMUM 3 % VOLTAGE DROP) <br />16. USE CONDUCTOR NOT SMALLER THAN NO. 10 AWG TO HOME RUN JUNCTION <br />BOXES FOR LINE POWER RECEPTACLES. (MAXIMUM 3 % VOLTAGE DROP) <br />17. USE NO. 10 AWG CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS <br />LONGER THAN 75 FEET, OR LARGER IF NOTED. (MAXIMUM 3 % VOLTAGE <br />DROP) <br />18. ALL SITE LIGHTING POLES AND POLE BASES SHALL BE CAPABLE OF SUPPORTING <br />THE ENTIRE WEIGHT AND WIND LOADS OF THE ENTIRE LIGHTING SYSTEM. SHOP <br />DRAWINGS MUST INCLUDE DRAWINGS OF THE ENTIRE ASSEMBLY FOR EACH OF <br />THE MOUNTING CONFIGURATIONS USED. DRAWINGS MUST BE SIGNED AND <br />SEALED BY FLORIDA REGISTERED STRUCTURAL ENGINEER AND SUBMITTED TO <br />THE LOCAL AHJ FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION AS A <br />REVISION TO THE PERMIT. <br />19. EXIT AND EMERGENCY LIGHTS SHALL BE WIRED ON LINE SIDE OF CONTACTORS, <br />MOTION SENSORS AND ANY LOCAL SWITCHES. <br />20. ALL CONDUITS SHALL BE ROUTED SURFACE ON STRUCTURE WITH FS OUTLET <br />BOXES / CONCEALED IN WALL FUR OUT, ABOVE DROPPED CEILING OR <br />UNDERGROUND (PREFERRED UNDERGROUND FOR NEW CONSTRUCTION) IN <br />FINISHED AREAS. <br />21. TOGGLE SWITCHES SHALL BE MOUNTED CENTERLINE 46" A.F.F. AND 6" FROM <br />DOOR OPENING OR CORNER, UNLESS OTHERWISE NOTED. <br />22. NO MORE THAN THREE CURRENT CARRYING CONDUCTORS SHALL BE COMBINED <br />IN ANY RACEWAY LION. <br />23. REFER TO THE SPECIFICATIONS AND NOTES OF THIS PROJECT FOR MORE <br />DETAILED INSTRUCTIONS. <br />24. LIGHTING SCHEDULE IS FOR REFERENCE ONLY. THE CONTRACTOR SHALL <br />SUBMIT THE TYPES AND MODEL NUMBERS TO THE ARCHITECT FOR APPROVAL <br />BEFORE PURCHASING. <br />25. ALL PATTERNED DOWNLIGHT TRIMS TO BE COORDINATED TO ENSURE <br />CONSISTENT PATTERN DIRECTION BY CONTRACTOR. <br />26. ALL RECESSED ADJUSTABLE DOWNLIGHTS MUST BE AIMED BY CONTRACTOR <br />AND CLOSELY COORDINATED WITH THE DEALER FOR VEHICLE ACCENT, <br />CUSTOMER GRAPHICS, AND DISPLAYS. <br />27. PROVIDE EMERGENCY BATTERY PACK FOR LUMINAIRES DESIGNATED AS <br />EMERGENCY. CONNECT ON LINE SIDE OF ALL SWITCHES AND CONTACTORS. <br />28. PROVIDE GROUND FAULT INTERRUPTER FOR ALL 125 VOLT, 15 & 20 AMP <br />RECEPTACLES WITHIN T-0" OF A SINK, AND IN THE SERVICE GARAGE AREAS PER <br />NEC 511. <br />29. ALL RECESSED LIGHTS IN INSULATED AREAS SHALL BE I.C. RATED. <br />30. ALL CONDUCTORS SHALL BE COPPER TYPE THHN/THWN UNLESS OTHERWISE <br />NOTED. <br />31. ALL LIGHTING SHALL BE LED, 0-10V DIMMABLE, UON. ALL LIGHTING SHALL BE <br />DIMMABLE. <br />32. FRONT OF HOUSE WIRING DEVICES SHALL BE LEVITON DECORA, WHITE OR <br />BLACK TO MATCH ADJACENT WALL, WITH WHITE OR BLACK SCREWLESS <br />FACEPLATES TO MATCH ADJACENT WALL, OR PRE -APPROVED EQUAL. <br />33. BACK OF HOUSE WIRING DEVICES SHALL BE LEVITON, SPECIFICATION GRADE. <br />34. GFCI TYPE RECEPTACLES SHALL BE INSTALLED IN A READILY ACCESSIBLE <br />LOCATION PER NEC 210.8. PROVIDE GFCI TYPE CIRCUIT BREAKERS WHERE GFCI <br />TYPE RECEPTACLES ARE NOT READILY ACCESSIBLE. <br />35. EMERGENCY LIGHTING SHALL BE PROVIDED BY U.L. LISTED BATTERY BACKUP <br />EMERGENCY BALLASTS THAT PROVIDE A MINIMUM OF 90 MINUTES BACKUP <br />POWER IN ACCORDANCE WITH FFPC 101:36.2.9. <br />- NEC ARTICLE 517 COMPLIANCE <br />1. TYPE HCF MC CABLE SHALL BE USED IN ALL PATIENT CARE AREAS. <br />2. PROVIDE HOSPITAL GRADE TAMPER PROOF RECEPTACLES IN ALL PATIENT <br />CARE AREAS. <br />3. ALL BRANCH CIRCUITS SERVING PATIENT CARE AREAS SHALL BE PROVIDED <br />WITH AN EFFECTIVE GROUND FAULT CURRENT PATH PER NEC 517.13(A)(B). <br />COMPLETION REQUIREMENTS <br />CONTRACTOR SHALL SUBMIT TO THE BUILDING OWNER RECORD DRAWINGS OF THE <br />ACTUAL INSTALLATION WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE. <br />RECORD DRAWINGS SHALL INCLUDE: 1). A SINGLE LINE DIAGRAM OF THE BUILDING <br />ELECTRICAL DISTRIBUTION SYSTEM AND 2). FLOOR PLANS INDICATING LOCATION AND <br />AREA SERVED FOR ALL DISTRIBUTION. <br />CONTRACTOR SHALL SUBMIT AN OPERATION AND MAINTENANCE MANUAL TO THE <br />BUILDING OWNER. THE MANUALS SHALL INCLUDE, AT A MINIMUM, THE FOLLOWING: <br />1). SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH <br />PIECE OF EQUIIPMENT REQUIRING MAINTENNANCE; 2). OPERATION MANUALS AND <br />MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. <br />REQUIRED ROUTINE MAINTENANCE ACTIONS CLEARLY IDENTIFIED; 3). NAMES AND <br />ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. <br />CONTRACTOR SHALL SUBMIT TO THE BUILDING OWNER DOCUMENTS CERTIFYING <br />THAT THE INSTALLED LIGHTING CONTROLS HAVE BEEN INSTALLED IN ACCORDANCE <br />WITH THESE DRAWINGS AND MEET DOCUMENTED PERFORMANCE CRITERIA OF 2020 <br />FBC ENERGY CONSERVATION CODE, SECTION C405, WITHIN 90 DAYS FROM THE DATE <br />OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY. <br />PRIOR TO PASSING FINAL INSPECTION, THE REGISTERED DESIGN PROFESSIONAL <br />SHALL PROVIDE EVIDENCE THAT THE LIGHTING CONTROLS HAVE BEEN TESTED TO <br />ENSURE THAT CONTROL HARDWARE AND SOFTWARE ARE CALIBRATED, ADJUSTED, <br />PROGRAMMED AND IN PROPER WORKING CONDITION IN ACCORDANCE WITH THE <br />CONSTRUCTION DOCUMENTS AND MANUFACTURER'S INSTRUCTIONS. FUNCTIONAL <br />TESTING SHALL BE IN ACCORDANCE WITH SECTION C408.3.1.1 AND C408.1.2 FOR THE <br />APPLICABLE CONTROL TYPE. <br />THIS DRAWING AND THE DESIGN SHOWN ARE THE PROPERTY OF <br />SPRING ENGINEERING, INC. AND ARE NOT TO BE REPRODUCED, <br />COPIED, PUBLISHED, OR USED IN WHOLE OR PART WITHOUT <br />WRITTEN CONSENT. THEY ARE TO BE USED ONLY FOR THE SITE AND <br />PROJECT IDENTIFIED AND SHALL BE RETURNED UPON REQUEST. <br />FOR <br />CONSTRUCTION <br />ISSUE DATE: 06.24.2022 <br />z <br />O <br />a- <br />U <br />W <br />w <br />0 <br />w <br />0 <br />w <br />M <br />� � • � �CEN <br />No.60205 = <br />itally signed by Carlos ail s <br />J&c=US, e0kiwimiral Pq' <br />d 'sxislnc'4ORIVP. <br />r-A'0141 8 E <br />7E8os M <br />Orama <br />Date: 2022.10.05 10:22:48 -04'0(' <br />W <br />�aJ <br />w <br />LU0 <br />F_ <br />U)� <br />Q W Cc <br />W <br />_ U co <br />LU Q LU _ <br />It _ <br />Q COI <br />am Oa <br />V <br />LU <br />CONTRACT DATE: <br />t <br />W <br />q <br />E <br />z <br />ZZ <br />l <br />Rz <br />z <br />Lil <br />LL,w <br />Z <br />a� <br />-A <br />s� <br />0 <br />0 <br />z <br />(D <br />(D <br />_j <br />�z <br />0 <br />ELECTRICAL <br />PLANS <br />DESIGNED BY: Designer <br />DRAWN BY: Author <br />CHECKED BY: Checker <br />JOB NO. <br />2022-16 <br />SHEET NO. <br />E001 <br />