Ij <br />SPECIFICATIONS: <br />DESIGN CRITERIA: BUILDING CRITERIA - 2016 FLORIDA BUILDING CODE, 6TH EDITION <br />DESIGN LOADS: <br />ROOF DEAD LOAD <br />ROOF LIVE LOAD <br />FLOOR DEAD LOAD <br />FLOOR LIVE LOADS <br />GROUND SNOW LOAD, Pg 0 PSF <br />WIND VELOCITY, Vult = 138 MPH <br />Vasd = 107 MPH <br />5 PSF <br />20 PSF <br />45 PSF 4.5" TOTAL DEPTH SLAB/DECK <br />10 PSF <br />MISC. <br />125 PSF <br />STORAGE <br />125 PSF <br />CORRIDORS <br />125 PSF <br />EXITS <br />RISK CATEGORY II <br />IMPORTANCE FACTOR 1.00 <br />EXPOSURE C <br />BUILDING IS DESIGNED AS FULLY ENCLOSED <br />IMPORTANCE FACTOR 1.00 <br />Ss = 6.8%g, S 1= 3.4%g <br />RISK CATEGORY II <br />Sds = 7.2%g, Sd1= 5.5%g <br />SEISMIC DESIGN CATEGORY A <br />SITE CLASS D (ASSUMED) <br />(Fa 1.6 Fv 2.4) <br />DESIGN BASE SHEAR (KIPS) = 51 (I -STORY) <br />RESPONSE COEFF = 0.024 <br />RESPONSE MOD FACTOR, R = 3 <br />ANALYSIS: EQUIVALENT LATERAL FORCE PROCEDURE <br />ALLOWABLE BEARING PRESSURE = 2000 PSF (ASSUMED) <br />STRUCTURALNOTES <br />1. TEMPORARY BRACING SHALL BE PROVIDED TO RESIST WIND LOADING ON STRUCTURAL <br />COMPONENTS AND STRUCTURAL ASSEMBLIES DURING ERECTION AND CONSTRUCTION <br />PHASE. <br />2. NEVER ALLOW YOUR ROOF TO COME IN CONTACT WITH, OR WATER RUNOFF FROM, ANY <br />DISSIMILAR METAL INCLUDING BUT NOT LIMITED TO COPPER, LEAD OR GRAPHITE. THIS <br />INCLUDES COPPER AND ARSENIC SALTS USED IN TREATED LUMBER, CALCIUM USED IN <br />CONCRETE, MORTAR AND GROUT. <br />3. SCOPES OF WORK BY OTHERS WHOSE LATERAL LOADS WILL BE TRANSFERRED INTO <br />STEEL MEMBER PROVIDED BY SELLER SUBCONTRACTOR SHALL BE TEMPORARILY <br />BRACED BY OTHERS IN A METHOD THAT DOES NOT INTERFERE WITH ERECTION OF STEEL, <br />UNTIL STEEL ERECTION IS COMPLETE. <br />4. THE UNCOATED MINIMUM STEEL THICKNESS OF THE COLD -FORMED PRODUCTS AS <br />DELIVERED SHALL NOT BE LESS THAN 95% PERCENT OF THE DESIGN THICKNESS. <br />THICKNESS MEASUREMENTS MAY BE MADE ANYWHERE ACROSS THE WIDTH OF THE <br />SHEET, BUT NOT CLOSER TO THE EDGES THAN THE MINIMUM DISTANCES SPECIFIED IN <br />THE RELEVANT ASTM SPECIFICATIONS. THICKNESS AT BENDS, SUCH AS CORNERS, MAY <br />BE LESS THAN 95 PERCENT OF DESIGN THICKNESS, DUE TO COLD -FORMING EFFECTS, AND <br />STILL BE ACCEPTABLE. <br />5. RECESSED ENTRIES AND BREEZEWAYS MUST BE RECESSED BELOW FINISHED FLOOR TO <br />AVOID POTENTIAL WATER PROBLEMS. ROLL UP LOCATED IN BREEZEWAY MUST BE <br />INSTALLED IN RECESSED AREA IF A CHANGE IS MADE BY OWNER/CONTRACTOR <br />SELLER/SUBCONTRACTOR MUST BE NOTIFIED IMMEDIATELY. <br />6. ALL ERECTION, FABRICATION, WORKMANSHIP AND INSTALLATION SHALL BE IN <br />ACCORDANCE WITH INSTALLATION PROCEDURES MANUAL <br />AND I OR INDUSTRY STANDARDS APPROVED BY SELLER / SUBCONTRACTOR AND THE <br />ENGINEER OF RECORD. <br />ROOF SYSTEMS: MBCI OR EQUAL <br />1. ROOF SHEETS SHOULD BE INSTALLED FROM THE LOWEST STEP-DOWN TO HIGHEST <br />ELEVATION. <br />2. ROOFING SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND SPECS, <br />ALONG WITH SELLER SUBCONTRACTOR INSTALL. PROCEDURES MANUAL. <br />FASTENERS AND ANCHORS <br />1. THE FOLLOWING OUTLINES THE MECHANICAL ANCHORS THAT ARE APPROVED FOR USE <br />ON THIS PROJECT. <br />A. EXPANSION ANCHORS - "KWIK BOLT TZ" BY HILTI OR EQUAL. DRILL HOLE IN <br />CONCRETE OR GROUT FILLED CMU AND REMOVE DUST. THE MIN. HOLE DEPTH MUST <br />EXCEED THE ANCHOR EMBEDMENT PRIOR TO TORQUING BY ONE HOLE DIAMETER. <br />DRIVE THE ANCHOR INTO THE HOLE USING A HAMMER. A MIN. OF SIX THREADS MUST <br />BE BELOW THE SURFACE OF THE FIXTURE. TIGHTEN THE NUT TO THE RECOMMENDED <br />INSTALLATION TORQUE (1/2" = 40 lbs./ft.). <br />B. ADHESIVE ANCHORS IN CONCRETE - "HIT HY-200" BY HILTI OR EQUAL. <br />A. ADHESIVE ANCHORS IN GROUT FILLED BLOCK - "HIT HY-20" BY HILTI OR EQUAL. <br />B. ADHESIVE ANCHORS IN HOLLOW BLOCK - "HIT HY-20" WITH SCREEN TUBES BY HILT! <br />OR EQUAL. <br />C. CONCRETE/MASONRY SCREWS - "KWIK-HUS EZ BY HILTI OR EQUAL. <br />D. POWDER -ACTUATED FASTENERS (PAF) - "DX" BY HILTI OR EQUAL. <br />2. ALL FASTENERS SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS <br />AND SPECIFICATIONS. <br />COLD FORM STEEL: LGSI SECTIONS OR EQUAL <br />LCOLD FORM STEEL SECTIONS SHALL CONFORM TO APPLICABLE PROVISIONS OF ASTM A572, <br />ASTM A607 AND/OR ASTM A611. <br />2.MIN. DELIVERED THICKNESS OF COLD FORMED STEEL C'S & Z'S GAGE <br />GAGE <br />DESIGN THINKNESS <br />FINISH <br />12 <br />0.105 <br />RED -OXIDE U.N.O ON PLANS <br />14 <br />0.07 <br />RED -OXIDE U.N.O ON PLANS <br />16 <br />0.059 <br />RED -OXIDE U.N.O ON PLANS <br />18 <br />0.0468 <br />GALVANIZED <br />20 <br />0.0352 <br />GALVANIZED <br />3. MIN. DELIVERED THICKNESS OF COLD FORMED STEEL <br />GAGE <br />DESIGN THINKNESS <br />FINISH <br />14 <br />0.07 <br />TEX-COTE FINISH APPLIED IN FILED <br />16 <br />0.059 <br />TEX-COTE FINISH APPLIED IN FIELD <br />16 <br />0.055 <br />PRE -FINISHED <br />18 <br />0.0468 <br />TEX-COTE FINISH APPLIED IN FIELD <br />4. LOAD BEARING STUD TO TRACK CONNECTIONS: THE ENDS OF THE LOAD BEARING STUDS <br />MUST BE INSTALLED INTO THE TOP AND BOTTOM TRACKS SO THAT THE GAP BETWEEN THE <br />ENDS OF THE STUD AND THE WEB OF THE TRACK IS AS SMALL AS PRACTICABLE AND IN NO <br />CASE GREATER THAN 3/16" AT THE TIME OF INSTALLATION. THE GAP MUST BE LESS THAN <br />1/16" AFTER THE DEAD LOAD OF THE STRUCTURE IS IN PLACE. <br />5. ALL COLD FORMED STEEL SHALL BE 50 KSI MIN. <br />HOT ROLLED STEEL <br />1. DESIGN OF STRUCTURAL STEEL ELEMENTS WAS COMPLETED UNDER THE <br />REQUIREMENTS SET FORTH IN THE "MANUAL OF STEEL CONSTRUCTION - ALLOWABLE <br />STRESS DESIGN (LATEST EDITION)". <br />2. MATERIAL SPECIFICATIONS <br />A. ALL STEEL SHALL BE DOMESTICALLY PRODUCED. <br />B. ASTM A36 - ROLLED SHAPES, PLATES AND BARS. <br />C. ASTM A992 - WIDE FLANGE SECTIONS. <br />D. ASTM A53, TYPE E, GRADE B - PIPE <br />E.ASTM A500 GRADE B - TUBES. <br />RASTM F 1554 (A36) - ANCHOR BOLTS, RODS, NUTS & WASHERS. <br />G. ASTM A108 GRADE 1015 THROUGH 1020, COLD FINISHED CARBON STEEL, AWS DL I, <br />TYPE B - HEADED STUDS. <br />H. ASTM A325, TYPE N - BOLTED STRUCTURAL CONNECTION <br />I. ASTM A307 - FOR BOLTED CONN. OF LESS THAN 5/8" DIA. <br />J. E70XX ELECTRODE (LOW HYDROGEN) - WELDED CONN. (U.N.0) <br />K. BOLTED CONN. SHALL BE MADE WITH A MIN. OF 3/4" DIA BOLTS (U.N.O.) <br />L.WELDED CONN. SHALL BE A MIN. OF 3/16" FILLET WELD ALL AROUND FOR CONN. <br />MEMBERS OF UP TO 1/4" FILLET WELD FOR ALL OTHER MEMBERS THICKNESS (U.N.O.) <br />3. ALL BOLTED CONNECTIONS SHALL BE "SNUG -TIGHT' AS DEFINED IN THE <br />"SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" BY <br />RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS (ROSC). (U.N.O.) <br />4. BOLTED CONNECTIONS, INDICATED TO BE "SLIP CRITICAL" (SC) SHALL BE INSTALLED, <br />TIGHTENED, TESTED AND INSPECTED AS OUTLINED IN THE "SPECIFICATIONS FOR <br />STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" BY RESEARCH COUNCIL ON <br />STRUCTURAL CONNECTIONS (ROSC). (U.N.O.) <br />5. BRACE AND MAINTAIN ALL STEEL IN ALIGNMENT UNTIL OTHER PARTS OF <br />CONSTRUCTION NECESSARY FOR PERMANENT SUPPORT ARE COMPLETED. <br />CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING TEMPORARY SHAORING AS <br />REQUIRED FOR THE STABILITY OF THE STEEL FRAME UNTIL ALL STRUCTURAL <br />ELEMENTS HAVE BEEN COMPLETED AND BUILDING IS ENCLOSED. <br />6. ALL WELDING SHALL CONFORM TO THE REQUIREMENTS OF "THE STANDARD CODE FOR <br />WELDING IN BUILDING CONSTRUCTION" OF THE AMERICAN WELDING SOCIETY. <br />7. GROUT FOR COLUMN BASE PLATES AND PRESET BEARING PLATES SHALL BE <br />NON -SHRINK, NON-METALLIC GROUT (5000PSI MIN.) <br />8. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT DIPPED GALVANIZED IN <br />ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF ASTM A123. <br />9. STRUCTURAL STEEL SHALL RECEIVE SHOP COAT OF PRIMER (COLOR AS DIRECTED BY <br />ARCHITECT) EXCEPT AREAS THAT WILL RECEIVE SPRAY -ON FIRE PROTECTION. <br />10. BEAM TO BEAM AND BEAM TO COLUMN CONNECTIONS SHALL BE DESIGNED BY THE <br />STEEL FABRICATORS FOR THE REACTIONS SHOWN ON THE FRAMING PLANS. SIGNED <br />AND SEALED SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW, WHICH CLEARLY <br />INDICATE THE ALLOWABLE LOAD CAPACITY OF EACH UNIQUE CONNECTION. WHERE <br />REACTION IS NOT INDICATED ON THE PLANS, THE CONNECTION SHALL BE DESIGNED <br />FOR THE MAXIMUM SHEAR CAPACITY OF THE BEAM, FOR THE GIVEN SPAN. <br />STEEL DECKING <br />1. THE REQUIREMENTS OF THE LATEST ADOPTED EDITION OF THE AISI SECTION A3, SHALL <br />GOVERN FABRICATION OF THE SPECIFIED STEEL DECK. <br />2. THE MINIMUM YIELD STRENGTH OF THE STEEL USED SHALL BE 33KSI (230MPa). <br />3. ALL FIELD WELDING OF DECK SHALL BE IN STRICT CONFORMANCE WITH ANSI 1 AWSD1.3 <br />STRUCTURAL WELDING CODE. <br />4. GALVANIZING SHALL CONFORM TO ASTM-A653-94, STRUCTURAL QUALITY, AND FEDERAL <br />SPEC. QQ-S-775, <br />5. THE VALUES LISTED IN THE TABLE SHOWN BELOW IS FROM THE VULCRAFT METAL DECK <br />PRODUCT MANUAL AND REPRESENTS THE MINIMUM ROOF DECK SECTION PROPERTIES <br />THAT ARE REQUIRED BY DESIGN. <br />ROOF DECK <br />DECK TYPE <br />DESIGN <br />I <br />Sp <br />Sn <br />THICK <br />In 4/FT <br />In 3/FT <br />FT <br />3�n <br />822 <br />0.0295 <br />0.169 <br />0.186 <br />0.192 <br />B20 <br />0.0358 <br />0.212 <br />0.234 <br />0.247 <br />B18 <br />0.0474 <br />0.292 <br />0.318 <br />0.327 <br />6. COMPOSITE STEEL FLOOR DECK SHALL BE ATTACHED TO THE SUPPORTING STRUCTURE <br />AS RECOMMENDED BY THE MANUFACTURER, WITH MAX. SPACING NOT TO EXCEED 24" <br />O.C. <br />7. THE VALUE LISTED IN THE TABLE SHOWN BELOW IS FROM THE VULCRAFT METAL DECK <br />PRODUCT MANUAL AND REPRESENTS THE MINIMUM COMPOSITE FLOOR DECK SECTION <br />PROPERTIES THAT ARE REQUIRED BY DESIGN. <br />COMPOSITE DECK FLOOR <br />DECK TYPE <br />DESIGN <br />/IFT In <br />Sp In 3/FT <br />THICK1.5VL22 <br />In <br />0.0295 <br />0.15 / 0.182 <br />0.178 / 0.186 <br />1.5VL20 <br />0.0358 <br />0.195 / <br />0.231 / 0.24 <br />0.222 <br />1.5VL18 <br />0.0474 <br />0.282 / <br />0.315 / 0.327 <br />0.295 <br />2.OVL22 <br />0.0295 <br />0.322 / <br />0.274 / 0.277 <br />0.329 <br />2.0VL20 <br />0.0358 <br />0.418 / <br />0.355 / 0.36 <br />0.415 <br />2.OVL18 <br />0.0474 <br />0.577 / <br />0.513 / 0.518 <br />0.2557 <br />3.OVL22 <br />0.0295 <br />0.746 / 0.745 <br />0.429 / 0.422 <br />3.OVL20 <br />0.0358 <br />0.938 / <br />0.553 / 0.572 <br />0.937 <br />3.OVL18 <br />0.0474 <br />1.251 / 1.251 <br />0.795 / 0.803 <br />8. NON -COMPOSITE STEEL FLOOR DECK SHALL BE A TACHED TO THE SUPPORTING <br />STRUCTURE AS RECOMMENDED BY THE MANUFACTURER WITH MAX. SPACING NOT TO <br />EXCEED 24" O.C. <br />9. STEEL USED TO MANUFACTURE THE NON -COMPOSITE METAL FLOOR DECKING SHALL <br />CONFORM TO THE REQUIREMENTS OF ASTM-A611 GRADES C, D, OR E ONIOR A653-94 <br />STRUCTURAL QUALITY. <br />10. THE VALUES LISTED IN THE TABLE SHOWN BELOW IS FROM THE VULCRAFT METAL DECK <br />PRODUCT MANUAL AND REPRESENTS THE MINIMUM NON -COMPOSITE FLOOR DECK <br />SECTION PROPERTIES THAT ARE REQUIRED BY DESIGN. <br />NON -COMPOSITE FLOOR DECK <br />DECK TYPE <br />DESIGN <br />THICK <br />I In 4/FT <br />Sp/ Sn In 3/FT <br />0.6C26 <br />0.0179 <br />0.015 / 0.015 <br />0.043 / 0.043 <br />0.6C24 <br />0.0239 <br />0.019 / 0.019 <br />0.057 / 0.057 <br />0.6C22 <br />0.0298 <br />0.024 / 0.024 <br />0.07 / 0.07 <br />MINIMUM STANDARDS FOR ELEVATED FLOORS <br />1. ALL CONCRETE SHALL HAVE THE FOLLOWING MIN. PROPERTIES: <br />LOCATION <br />28 DAY STREHGTH <br />SLUMP <br />MAX <br />AGGR. <br />ELEVATED SLABS FORMED AND <br />4,000 psi <br />4" t 1" <br />1 " <br />POURED <br />ELVEVATED SALBS FORMED W / MTL <br />3,000 psi <br />4" t 1" <br />1" <br />DECK <br />A. SLUMP FOR RAMPS AND SLOPING SURFACES SHALL NOT EXCEED 4". <br />B. SEE MASONRY GENERAL NOTED FOR GROUT TESTING REQUIREMENTS. <br />C. COLD JOINTS (NOT RECOMMENDED) & CONTROL JOINTS SHOULD BE PLACED A <br />MINIMUM OF T-0" OFF CENERLINE OF COLUMNS. <br />2. CONCRETE PROPERTIES SHALL BE VERIFIED THROUGH INDUSTRY STANDARD TESTING <br />PROCEDURES BY A CERTIFIED TESTING AGENCY. MIN TEST REQUIRED SHALL INCLUDE <br />SLUMP AND CYLINDER BEAKS FOR COMPRESSIVE STRENGTH. FINDINGS SHALL BE <br />SUBMITTED TO THE ARCH./ENG. FOR REVIEW. <br />3. CONCRETE WORK SHALL CONFORM TO LATEST EDITIONS OF ACI 301 SPECIFICATIONS <br />FOR STRUCTURAL CONCRETE FOR BUILDINGS, ACI 318 BUILDING CODE <br />REQUIREMENTS FOR REINFORCED AND ACI 315 DETAILS AND DETAILING OF <br />CONCRETE REINFORCEMENT. <br />4. CONCRETE MIX DESIGN SHALL MEET THE FOLLOWING CRITERIA: <br />A. PROPOSED MIX DESIGN SHALL BE ACCORDANCE WITH ACI 301 METHOD 1 <br />B. ENTRAPPED AIR CONTENT SHALL NOT EXCEED 3%. <br />C. ADMIXTURES USED TO ENTRAIN AIR ARE NOT ACCEPTABLE. <br />D. ALL CONCRETE TO BE NORMAL WEIGHT WITH A DESIGN STRENGTH AT 28 DAYS. <br />6. SITE ADDED WATER IS NOT ACCEPTABLE. ADDING WATER TO THE MIX WILL RESULT <br />IN REJECTION OF THE RESULTS BY THE ENGINEER OF RECORD. <br />7. CONTRACTOR IS RESPONSIBLE FOR THE ADEQUACY OF THE FORMS AND SHORING <br />AND FOR SAFE PRACTICE IN THEIR USE AND REMOVAL. <br />8. PLACING OF CONCRETE IN ALL REINFORCED COLUMNS AND WALLS SHALL BE IN <br />LIFTS NOT EXCEEDING 71/2 FEET IN HEIGHT. CONCRETE SHALL BE PLACED THROUGH <br />ELEPHANT TRUNK TUBULAR SHUTES LOCATED SUCH THAT THE FREE AIR DROP OF <br />THE MIX DOES NOT EXCEED 6 FEET. ALTERNATE PLACEMENT METHOD OF CONCRETE <br />WITH OR WITHOUT ADMIXTURES SHALL NOT BE USED UNLESS APPROVED BY <br />ENGINEER OF RECORD. <br />9. THE VALUES IN THE TABLE SHOWN BELOW IS FROM THE VULCRAFT METAL DECK <br />PRODUCT MANUAL AND REPRESENTS THE RECOMMENDED WELDED WIRE FABRIC. <br />DECK TYPE <br />TOTAL SLAB DEPTH <br />RECOMMENDED WELDED WIRE FABRIC <br />1.5VL, VLI, OR R <br />< 43/" <br />6x6 - W1.4 x W1.4 <br />1.5VL, VLI, OR R <br />> 4X" <br />6x6 - W2.1 x W2.1 <br />2VLI <br />< 5Ya" <br />6x6 - W1.4 x WI A <br />2VLI <br />> 5Y" <br />6x6 - W2.1 x W2.1 <br />3VLI <br />K 644" <br />6x6 - W1.4 x WI A <br />3VLI <br />> 6 " <br />6x6 - W2.1 x W2.1 <br />FIBER REINFORCED CONCRETE IS AN ALTERNATE TO WELDED WIRE FABRIC (WWF). <br />REINFORCED CONCRETE FIBERS SHALL BE 100% VIRGIN POLPROPYLENE, FIBRILLATED <br />FIBERS AS MANUFACTURED BY FIBER MESH CO, OR APPROVED EQUAL, APPLIED AT A <br />RATE OF 4 LBS/CY. <br />ELEVATED FLOOR DECKS ARE DESIGNED FOR A 20 PSF CONTRUCTION LIVE LOAD. <br />RIDE ON TROWEL MACHINES SHOULD NOT BE USED UNLESS THE DECK IS SHORED. <br />CONCRETE WORK <br />1. MONOLITHIC SLAB FINISHES: THE FOLLOWING REQUIREMENTS ARE BASED ON THE <br />LATEST FLOOR FLATNESS (FF)/ FLOOR LEVELNESS (FL) VALUES/METHODS. BIDS FOR <br />THIS WORK SHALL REFLECT THESE REQUIREMENTS AND ENFORCEMENT THEROF CAN <br />BE EXPECTED. <br />A. NON -CRITICAL FLOOR TOLERANCE <br />1. FLOAT FINISH (FLT-FN) <br />2. SPECIFIED OVERALL VALUE: FF251 FL20 <br />3. MINIMUM LOCAL VALUE: FF25IFL20 <br />4. APPLY FLOAT FINISH TO MONOLITHIC SLAB SURFACES THAT ARE TO RECEIVE MUD SET <br />TILE AND OTHER THICK FINISHES, AND TO SLAB SURFACES WHICH ARE TO BE COVERED <br />WITH WATERPROOFING MEMBRANE. <br />B. TYPICAL CORRIDOR OR NORMAL SIZED ROOMS (100-600 SF) <br />LTROWEL FINISH 1(TR-FNI) <br />2.SPECIFIED OVERALL VALUE: FF301FL23 <br />3.MINIMUM LOCAL VALUE: FF251FL20 <br />4.APPLY TROWEL FINISH TO MONOLITHIC SLAB SURFACES THAT ARE TO RECEIVE <br />RESILIENT FLOORING, CARPET, PAINT, OR OTHER THIN FILM FINISH COATING SYSTEM. <br />ELEVATED SLABS SHALL HAVE A SPECIFIED OVERALL VALUE OF FF22 TO FF27 AND A <br />MINIMUM LOCAL OF FF20 WITH NO FL NUMBER DEFINED. <br />2.MINIMUM THICKNESS OF SLAB ON GRADE IS THE GREATER OF 3" OR 0.8 TIMES ANCHOR <br />EMBEDMENT SPECIFIED IN CONSTRUCTION DOCUMENTS (ASSUMES USE OF HILTI KWIK <br />BOLT TZ) <br />3.CONTROL JOINT AND CONTROL JOINTS SHOULD BE PLACE AMIN. 2'- 0" OFF THE <br />CENTERLINE OF COLUMNS. IF THE DISTANCE BETWEEN COLUMNS IS LESS THAN 4'- 0" BUT <br />GREATER THAN 2'- 6" THEN PLACE AT MID -POINT OTHERWISE CONTACT ENGR. OF <br />RECORD. <br />SITE REQUIREMENT NOTES <br />1. OWNER 1 CONTRACTOR SHALL ENSURE THAT SITE IS STABILIZED AND MAINTAINED <br />DURING HEAVY PRECIPITATION. <br />2. OWNER I CONTRACTOR SHALL PROVIDE MATERIAL STORAGE AREA ON SITE OTHER THAN <br />BUILDING BEING ERECTED. <br />3. OWNER 1 CONTRACTOR SHALL PROVIDE A CONSTRUCTION DUMPSTER UNIT ON THE <br />JOBSITE AT NO COST TO SELLER SUBCONTRACTOR. <br />4. OWNER 1 CONTRACTOR SHALL PROVIDE TEMPORARY POWER TO ALLOW FORA MAXIMUM <br />POWER LEAD RUN OF 200 FEET TO EACH STRUCTURE BEING ERECTED. <br />5. TEMPORARY POWER MUST MEET ALL APPLICABLE CODES AND SAFETY REQUIREMENTS. <br />6. OWNER 1 CONTRACTOR MUST ENSURE THAT BUILDING PADS ARE BROOM CLEAN AND <br />FREE OF DEBRIS PRIOR TO SELLER SUBCONTRACTOR CREW BEGINNING INSTALLATION <br />SEQUENCE AS AGREED. <br />7. OWNER / CONTRACTOR SHALL ENSURE THAT THE SITE AND ALL SIDES OF BUILDING ARE <br />ACCESSIBLE WITH EQUIPMENT, AND FREE FROM ANY OBSTRUCTIONS TO DELIVERY OR <br />ERECTION. <br />8. CLEANING OF MATERIALS, INCLUDING BUT NOT LIMITED TO, WALL PANELS AND <br />STRUCTURAL MATERIALS, IS NOT RESPONSIBILITY OF SELLER/SUBCONTRACTOR. <br />9. THE OWNER I CONTRACTOR SHALL PROPERLY PROTECT THE WORK FOR PUBLIC SAFETY <br />AND AGAINST ACCIDENTS, WEATHER OR ANY OTHER HAZARDS WITH LIGHTS, <br />GUARDRAILS OR BARRICADES AS APPLICABLE (INCLUDES FALL PROTECTION ON <br />MULTI -STORY BUILDINGS). <br />Concrete Sub and General Contractor responsibility for the below <br />1. WALK BEHIND CONCRETE FINISHING MACHINES SHOULD KEEP A MINIMUM SEPARATION <br />OF 20 FEET. WALL BEHIND MACHINES SHALL NOT EXCEED 300 LBS IN WEIGHT. <br />2. RIDE ON FINISHING MACHINES ARE NOT ALLOWED <br />3. ALL MACHINES LOADED ONTO DECK TO BE PLACED ABOVE BEARING WALLS AND NOT IN <br />THE DECK MIDSPANS. <br />4. CONCRETE PUMP HOSES SHALL PUMP NO MORE THAN 2' ABOVE METAL DECK WHILE <br />POURING. <br />5. CONCRETE SHALL BE SPREAD ON THE DECK IMMEDIATELY AS IT IS PUMPED TO ENSURE <br />THERE IS NO PILE UP OF THE CONCRETE THAT WILL OVERLOAD THE DECK. <br />6. CONTRACTOR AND TESTING COMPANY ARE RESPONSIBLE TO MONITOR EACH TRUCK TO <br />ENSURE WATER IS NOT ADDED TO THE MIX. CONCRETE CYLINDER SAMPLES SHALL BE <br />TAKEN OF THE MIX ENTERING THE CONCRETE PUMP TO ENSURE WATER WAS NOT <br />ADDED. CONCRETE CYLINDER TEST BREAK REPORTS SHALL BE PROVIDED TO THE <br />ENGINEER TO VERIFY THE MIX INSTALLED MEETS THE COMPRESSIVE STRENGTH <br />REQUIREMENTS. <br />7. CONTRACTOR IS RESPONSIBLE TO ENSURE THE CONCRETE IS CURED PROPERLY BASED <br />ON THE WEATHER CONDITIONS. THE SLAB MUST CURE FOR A MINIMUM OF 3 DAYS PRIOR <br />TO ANY WORK BEING COMPLETED ON THE NEW DECK. CONTRACTOR SHALL OBTAIN A 3 <br />DAY CONCRETE SAMPLE BREAK TO ENSURE THE DECK HAS REACHED 70% COMPRESSIVE <br />STRENGTH TO PROCEED. <br />8. SUBMITTAL OF CONCRETE MIX AND REINFORCING OPTION IS REQUIRED. COMPLETE <br />SUBMITTALS MUST BE SUBMITTED AND LABELED FOR EACH LOCATION (I.E. SLAB ON <br />GRADE, SLAB ON DECK). IT MUST BE CLEARLY INDICATED WHICH SUBMITTALS ARE FOR <br />EACH LOCATION IF THEY ARE SUBMITTED AS ONE PACKAGE. <br />FRAYCINC& <br />CAN START <br />Ll ANYTIME <br />r-�-� <br />t8 r <br />1�:. lower .Amor- <br />Zabik Turner Engineering, PLLC <br />Jennifer Zabik, P.E., S.E. <br />1024 N Fullers Cross Road <br />Winter Garden, FL 34787 <br />jzabik@ztengineering.com <br />P-1294 <br />SEALS `\,\►►ttti��o��i <br />LYNIV <br />�,\GENSF•;��% <br />• No. 265 <br />ST E Q: <br />c off• �?� <br />r <br />NAL <br />��rTtt1►1►\\ <br />RAPD <br />DUI LDtI+laG SQL � IONS <br />350 E Crown Point Rd <br />Suite 1080 <br />Winter Garden, FL 34787 <br />Phone: (407) 347-9614 <br />Info@ <br />rapidbuildingsolutions. corn <br />JOB NAME: <br />Zephyrhills Commons <br />38001 Pretty Pond Road <br />Zephyrhills, FL <br />JOB NUMBER: <br />268-19-ZEP-FL <br />REV <br />DATE <br />DESCRIPTION <br />APP <br />1 <br />11-28-19 <br />Layout Review <br />JL <br />0 <br />12-16-19 <br />Review <br />RG <br />1 <br />12-19-19 <br />RBS RL <br />RG <br />2 <br />12-20-19 <br />ZTE RL <br />RG <br />3 <br />01-21-20 <br />CUST. REDLINES <br />RG <br />4 <br />01-22-20 <br />REVIEW <br />RG <br />5 <br />01-24-20 <br />HECTOR RL <br />AC <br />6 <br />03-08-20 <br />Review 1 <br />RC <br />ISSUE DATE: Novermber 28,2019 <br />DESIGNED BY: RBS DRAWN BY: JL <br />CHECKED BY: RBS SUBMITTED BY: CSD <br />8ft 4ft Oft 8ft 1 6ft <br />DETAILS: NOT TO SCALE <br />APPROVED FOR PRODUCTION <br />INITIALS OF GC/OWNER <br />RBS-Om I <br />