Laserfiche WebLink
sustainable 1,0,insulation <br />Specification Sheet <br />Metal Building Insulation 202-96 <br />CertainTeed <br />SAINT-GOBAIN <br />PRODUCT DESCRIPTION <br />CertainTeed Metal Building <br />Basic Use: CertainTeed Fiber Glass Metal Building ^` <br />Product Name Insulation 202-96 <br />Insulation 202-96 is a flexible blanket insulation <br />Manufacturer CertainTeed Corporation <br />furnished in rolls and intended to be laminated on <br />one side with a suitable vapor retarder. It is used as <br />Address P.O. Box 860 <br />a thermal and acoustical insulation in the roofs and <br />Valley Forge, PA 19482-0105 <br />sidewalls of pre-engineered metal buildings and <br />Phone 610-341-7000 • 800-233-8990 <br />post frame construction. <br />Fax 610-341-7571 <br />Benefits: Metal Building Insulation 202-96 <br />reduces transmission of exterior sound to the <br />Website www.certainteed.com/insulation <br />interior Of the building and absorbs reverberating <br />sounds within the building. <br />TECHNICAL DATA <br />Composition and Materials: The product is composed of tan, uniformly textured, inorganic fibrous <br />glass and formed with a formaldehyde -free binding agent. <br />Applicable Standards <br />Limitations: This product is designed for use in interior (weather protected) walls and roofs of <br />• Model Building Codes: <br />pre-engineered metal buildings. It should be laminated on a first -in, first -out basis and should be kept <br />- ICC <br />dry at all times during processing and end use. After lamination, packaging should not exceed a 5.5:1 <br />• Material Standards: <br />compression ratio. For additional information, please refer to the appendix of the NAIMA 202-96 (Rev. - ASTM C991, Type I <br />2000) standard. <br />- NAIMA 202-96 (Rev. 2000) <br />Sizes: Standard available sizes as noted in table below. <br />Contact CertainTeed for <br />non-standard sizes. <br />Fire Resistance <br />INSTALLATION <br />Fire Hazard Classification: <br />THERMAL PERFORMANCE <br />The vapor retarder on Metal Building <br />Nominal Thickness <br />R-Value <br />- UL 723, ASTM E84, NFPA 255 <br />Max. Flame Spread Index: 25 <br />Insulation 202 96 should be installed toward <br />(Pre -Lamination) <br />Max. Smoke Developed Index: 50 <br />the conditioned spaces in the building. The <br />in. mm <br />R RSI <br />- CAN/ULC-S102-M88 <br />Insulation is normally applied over or between <br />3N 86 <br />10 1.76 <br />the structural members of the building and <br />31/a 95 <br />11 1.94 <br />Non-combustible: <br />held in place by the covering sheets or <br />4Y6 ill <br />13 2.29 <br />- ASTM El 36 / Meets requirements <br />insulation support system. When using high <br />5Ya 133 <br />16 2.82 <br />Physical/Chemical Properties <br />R-Value systems, it is recommended that the <br />6% 162 <br />19 3.35 <br />cavity between the exterior metal sheet and <br />6a/ 171 <br />21 3.70 <br />• Thermal Resistance: <br />the faced fiber glass insulation should be <br />8 203 <br />25 4.40 <br />- ASTM C518 and/or ASTM C177 at 75T (24°C) <br />completely filled. <br />9/ 235 <br />30 5.30 <br />mean temperature: see table at left <br />• Acoustical Performance: see tables on other side <br />• Water Vapor Sorption: <br />AVAILABLE SIZES <br />- ASTM C1104 / No greater than 5.0% by weight <br />R-value Nominal Thickness <br />Width <br />I Leno <br />• Corrosiveness: <br />R in. rem in. <br />rem <br />g in <br />-ASTM C665 /Meets requirements for steel, <br />10 3% 76.2 36, 48, 60, 72 <br />914, 1219, 1524,1829 <br />100 30.5 <br />copper and aluminum <br />11 33A 88.9 36, 48, 60, 72 <br />914,1219,1524,1829 <br />100 30.5 <br />• Odor Emission: <br />13 4% 101.6 36, 48, 60, 72 <br />914,1219,1524,1829 <br />75 22.9 <br />- ASTM C1304 / Pass <br />16 5Y4 133.35 36, 48, 60, 72 <br />914,1219,1524,1829 <br />50 15.2 <br />• Fungi Resistance: <br />19 6% 127 36, 48, 60, 72 <br />914,1219,1524,1829 <br />50 15.2 <br />- ASTM C1338 / Pass Test <br />21' 63/4 152.4 36,48,60,72 <br />914, 1219,1524,1829 <br />45 13.7 <br />quality Assurance <br />25' 8 203.2 36, 48, 60, 72 <br />914, 1219, 1524,1829 <br />30 9.1 <br />CertainTeed's commitment to quality and <br />30' 9A 203.2 36, 48, 60, 72 <br />914,1219,1524,1829 <br />25 7.6 <br />environmental management has ensured the <br />registration of the Athens. Chowchilla and Kansas <br />Non-standard widths are available and subject to an upcharge on an individual basis determined by <br />manufacturer's <br />City plants to ISO 9001:2000 and ISO 14001: <br />capability, quantity, lead times and packaging availability. 'R-21, <br />R-25 and R-30 are made to order. <br />2004 standards. <br />EcoTouch° Insulation with PureFiber° Technology <br />® for Certified R Metal Building <br />INNOVATIONS FOR LIVING <br />Product Data Sheet <br />Typical Physical Properties <br />Property Test Method _< <br />Thermal Resistance ASTM 077/C318 <br />Surface Burning <br />UL 723VASTM E84 <br />Result <br />(see "Description") <br />Flame spread index < 25 <br />Smoke developed index < 50 <br />Combustion Characteristics ASTM EI36 Non-combustible <br />Water Vapor Sorption ASTM C1104 s 0.2% by volume <br />Fungi Resistance ASTM C1338 Passes - no growth exhibited <br />Corrosiveness ASTM C665 Passes <br />Odor Emission ASTM C1304 Passes - no odor detected <br />I.The surface burning characteristics of these products have been determined in accordance with UL 723. The <br />❑ R- I 0 3.4' ❑ R- 19, 6.3" <br />standard should be used to measure and describe the properties of materials, products or assemblies in response to <br />heat and name under controlled laboratory conditions and should not be used to describe or appraise the fire hazard <br />❑ R-11, 37' ❑ R-25, 8,0" <br />or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used <br />as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of <br />❑ R- 13, 43' ❑ R-30, 9.25' <br />the fire hazard of a particular end use. Values are reported <br />to the nearest 5 rating. <br />❑ R- 16, 5.3" <br />• Uses a minimum of 65% <br />Installation <br />recycled content 41% being <br />Several methods are used to <br />Description <br />post -consumer <br />insulate metal buildings. The usual <br />Owens Corning EcoTouchO <br />• GREENGUARD Children & <br />method is to apply the insulation <br />Insulation with PureFiber® <br />Schools Certified . <br />Over the structural members <br />Technologyfor Certified R <br />• Easy to handle. <br />(purlins and girts) and inside the <br />exterior panels. This method <br />Metal Building is a light density <br />• Excellent recovery provides <br />generally accommodates single <br />fibrous glass blanket designed to <br />outstanding thermal and <br />layer installations. Methods are <br />be laminated with a variety of <br />acoustical performance. <br />also available to apply insulation <br />appropriate facings. Certified R <br />Product Applications <br />between purlins so as to <br />is available in standard R-values <br />of 10, 11, 13, 16, 19, 25 and 30. <br />EcoTo® Insulation with <br />accommodate greater insulation <br />Standard roll widths are 36", 48", <br />PureFi er <br />PureFiber° Technology for <br />thicknesses and better thermal <br />performance. <br />60" and 72". Selected Made -to- <br />Certified R Metal Building is used <br />Order widths are also available. <br />as part of the insulation system in <br />the roofs and side walls of metal <br />Technical Information <br />Key Features <br />buildings. It is designed to be <br />Owens Corning EcOTouch8 <br />laminated with a variety of facings <br />Insulation with PureFiber <br />• EcOTouchO insulation is the <br />to provide attractive interior <br />Technology for Certified R Metal <br />only fiberglass insulation <br />finishes, abuse resistance, and <br />Building is regularly tested to <br />product listed in the USDA <br />assistance in control of moisture. <br />ensure compliance to the NAIMA <br />BioPreferredsM Catalog. <br />202-96 (Rev. 2000) Standard. <br />• Formaldehyde-free2. <br />Owens Corning reFib c®® <br />Insulation with PureFiber <br />Sampling and testing is performed <br />• Made with 99% natural' <br />Technology for Certified R Metal <br />b the National Association of <br />Home Builders Research Center <br />HomeB- fide <br />materials —not acrylic. <br />Building are fabricated and <br />is <br />The product e <br />(NAHlabeled <br />• Made in the U.S.A.' <br />distributed in a nation wide <br />network of independent <br />on the top surface of <br />laminators assuring prompt service <br />each roll with the nominal R-value <br />"NAIMA <br />and delivery, Contact your Owens <br />and the 202-96" (Rev. <br />I. Meets requirements orthe Buy American Act. <br />Corning Sales Representative for <br />2000) to indicate compliance. <br />2. Applies to the insulation component only. <br />3. Unfaced insulation made with a minimum of 99%by <br />the names of insulation laminators <br />The NAIMA 202-96 (Rev. 2000) <br />weight natural materials consisting of minerals and <br />servicing your area. <br />standard specifies thermal <br />plant -based compounds. <br />AVAILABILITY AND COST <br />SOUND ABSORPTION - UNFACED <br />Manufactured and sold throughout the United States <br />R-Value Nom. Thickness <br />Absorption Coefficients @ Octave Band Frequencies (Hz) <br />and Canada. For availability and cost, contact your <br />R in. mm <br />125 250 500 1000 <br />2000 <br />4000 <br />NRC <br />local distributor or call CertainTeed Sales Support <br />Group in Valley forge, PA at 800-233-8990. <br />10 3% 86 <br />0.29 0.82 1.02 0.94 <br />0.96 <br />0.98 <br />0.95 <br />11 34: 95 <br />0.39 0.91 1.01 0.92 <br />0.93 <br />0.98 <br />0.95 <br />WARRANTY <br />13 4-% ill <br />0.53 0.97 1.04 0.90 <br />0.95 <br />0.98 <br />0.95 <br />In as much as CertainTeed has no control over <br />16 5'/a 133 <br />0.67 1.05 1.02 0.92 <br />0.98 <br />0.99 <br />1.00 <br />installation design, installation workmanship, <br />19 646 162 <br />0.89 1,22 1.02 0.98 <br />1.01 <br />1,00 <br />1.05 <br />accessory materials or conditions of application, <br />CertainTeed does not warrant the performance or <br />Sound absorption tested in accordance with ASTM C423 using Type A mounting per ASTM E795. <br />results of any installation containing its products. <br />SOUND TRANSMISSION <br />MAINTENANCE <br />_ <br />Transmission Loss in dB at the Octave Frequencies <br />STC <br />An inspection and preventative maintenance <br />Construction Type <br />Rating <br />program for the insulation and vapor retarder <br />125 250 500 1000 <br />2000 <br />40DO <br />system is recommended to ensure optimum <br />ROOFS <br />performance. <br />No Insulation <br />12 13 19 24 <br />30 <br />32 <br />24 <br />TECHNICAL SERVICES <br />R-10 Faced 202-96 Insulation Over <br />me Pudins <br />12 16 26 37 <br />45 <br />49 <br />29 <br />Technical assistance can be obtained either from <br />R-19 Faced 202-96Insulation Over <br />13 20 30 41 <br />49 <br />51 <br />32 <br />the local CertainTeed sales representative, or by <br />the Pudins <br />calling CertainTeed Sales Support Group in Valley <br />202-96Insulation Over & Between <br />Forge, PA at 800-233-8990. <br />the Pudins to Fill the cavity (R-25 <br />14 24 34 44 <br />53 <br />56 <br />36 <br />Combined) <br />FILING SYSTEMS <br />WALLS <br />• CertainTeed Pub. No. 30-25-056. <br />No Insulation <br />12 14 19 19 <br />20 <br />27 <br />21 <br />• Additional product information available <br />� 0IFa� 202-96Insulation Over <br />13 16 25 32 <br />37 <br />46 <br />28 <br />upon request. <br />R-13 Faced 202-961nsulatbn Over <br />13 17 26 33 <br />38 <br />47 <br />29 <br />the Girls <br />R-13 Faced 202-96 Insulation Over <br />the Girls 3-5/8" Steel Studs on 24" <br />26 40 51 60 <br />64 <br />65 <br />50 <br />Centers with 1/2" Gyp. Board on <br />Interior <br />R-13 Faced 202-96 Insulation Over <br />the Girls 3-5/8" Steel Studs on 24" <br />31 43 55 68 <br />73 <br />75 <br />54 <br />Centers with R-11 Batts & 1/2" Gyp. <br />Board on Interior <br />Sound Transmission Class (STC) in accordance with ASTM E90. <br />- Roof constnlction is 24ga. standing seam roof with 8" Z pudins on 5' centers. <br />- Wall construction is 26ga. wall panels screwed to 8" Z girls plated on T centers. <br />- Interior metal furring wall studs were 3-5/8" by 25ga. on 24' centers. <br />Seal and "900152000• <br />�fW consulate +' •1f I _ NArrs <br />tE ' REENGUARD ,� �'.� ... ...-. <br />ENERGY STAR NAIMA <br />-- Indoor Ai,Qual"r Ceruno�� sr[aEo <br />ASK ABOUT OUR OTHER CERTAINTEED PRODUCTS AND SYSTEMS: <br />EXTERIOR: ROOFING • SIDING • WINDOWS • FENCE • RAILING • TRIM • DECKING • FOUNDATIONS • PIPE <br />INTERIOR: INSULATION • GYPSUM • CEILINGS <br />CertainTeed Corporation Professional: 800-233-8990 <br />P.O. Box 860 Consumer: 800-782-8777 <br />Valley Forge, PA 19482 www.certainteed.com/insulation <br />Code No. 30-27-016, ® 10/10 CertainTeed Corporation <br />CertainTeed <br />SAINT-GOBAIN <br />EcoTouch° Insulation with PureFiber Technology <br />for Certified R Metal Building <br />INNOVATIONS FOR LNING' <br />Product Data Sheet <br />performance which provides the Standards, Codes Environmental and <br />capability of obtaining nominal Compliance Sustainability <br />thermal resistance (R-values) . ASTM C991-08, Flexible Owens Corning is a worldwide <br />after laminating. The actual Fibrous Glass Insulation for leader in building material systems, <br />thermal performance obtained Metal Buildings; Type I. insulation and composite solutions, <br />from the laminated product delivering a broad range of high - <br />will depend primarily on the • NAIMA 202-96 (Rev, 2000) quality products and services. <br />recovered thickness, Note that Standard for Flexible Fiber Glass Owens Corning is committed to <br />these nominal R-values are for Insulation to be Laminated for driving sustainability by delivering <br />the insulation only and do not Use in Metal Buildings. solutions, transforming markets <br />include the effects of facings, air Certifications and Sustainable and enhancing lives, More <br />films, compression of insulation at Features of EcoTouchE information can be found at http:H <br />framing members, conductance Insulation with PureFiber° sustainability.owenscorning.com. <br />through fasteners, or other heat Technology for Certified R <br />transfer paths particular to an Metal Building <br />installation. <br />• EcoTouch° insulation is the <br />The recovered thickness achieved only fiberglass insulation <br />will depend on a number of product listed in the USDA <br />variables determined in the BioPreferredsM Catalog, <br />laminating process and hence • Certified by Scientific <br />are outside of Owens Corning's Certification Systems to contain <br />control. To address these issues, a a minimum of 65% recycled <br />number of leading metal building glass content <br />insulation laminators produce <br />products which meet the • Certified to meet indoor air <br />National Insulation Association's quality standards underthe <br />"Certified Faced Insulation stringent GREENGUARD <br />Standard" (NIA 404). Samples of Indoor Air Quality Certification <br />faced products are periodically Programsm, and the <br />tested by a nationally recognized GREENGUARD Children & laboratory and determined to Schools Certification ProgramsM <br />meet the NIA standard. <br />USDA <br />CERTIFIED <br />BIOBASED <br />PRODUCT <br />PRODUCT 57", <br />rp�na® N A H B <br />RESEARCH <br />smaadcormn C E N TER/i ctdd,E" a s,"om, <br />Technical information <br />ationq REENGUARD GUARD"' <br />Technical information contained herein is furnished G R E E N <br />without charge or obligation and is given and accepted at «...,• APPROVED QIndoor Air Quality Certified ndoor Air Quality Certified <br />recipient's sole risk. Because conditions of use may vary <br />and are beyond our control, Owens Corning makes no <br />representation about, and is not responsible or liable for <br />the accuracy or reliability ofdata associated with particular OWENS CORNING INSULATING SYSTEMS, LLC <br />uses of any product described herein. ® ONE OWENS CORNINGPARKWAY <br />Scient�cCertificationSystems (SCS)provides independent • TOLEDO, OHIO, USA43659 <br />verification of recycled content in building materials and • P 1-800-GET-PINK' <br />verifies recycled content claims made by manufacturers. INNOVATIONS FOR LIVING' www.owenscorningcommercial.com <br />For more information, visit www. scscertified.com. <br />Pub. No.15086-R. Printed in U.S.A. September 2012, THE PINK PANTHER" <br />The GREENGUARD INDOORAIRQUALITY CERTIFIED &@1964-2012 Metro -Goldwyn -Mayer Studios Inc. All Rights Reserved -The <br />Mark is a registered certification mark used under license colorPINKisaregistered trademarkof0wensCorning.02012Owens Corning. <br />through the GREENGUARD Environmental Institute. All Rights Reserved. <br />Product Data Sheet <br />All-purpose foam panel <br />insulation for masonry and <br />other applications. <br />Owens Corning FOAMULAR 150 extruded <br />polystyrene insulation is ideal for wall <br />furring, perimeter/foundation, cavity <br />wall, crawispace, pre -cast concrete, under <br />slab, sheathing and other applications. <br />Owens Corning's patented Hydrovac" <br />process technology makes the unique <br />closed -cell structure of FOAMULAR <br />insulation highly resistant to moisture, <br />retaining its initial R-value* year after <br />year - even following prolonged exposure <br />to water leakage, humidity, condensation. <br />ground water and freeze/thaw cycling. <br />FOAMULAR 150 Performance Benefits <br />• High R-value (R-5 per inch of product <br />thickness)! <br />• Compressive strength of 15 psi. <br />• Effective resistance against moisture, <br />mildew, corrosion and rot. <br />• Ease of handling and installation <br />(lightweight, tough, rigid foam panels). <br />• Easy to saw, cut and score. <br />• Wide selection of sizes and thicknesses. <br />• Availability in straight, tongue and <br />groove, or scored square edges. <br />• Compliance with building codes and <br />standards. <br />FOAMULAR 150 <br />Superior Insulation Performance for a <br />Wide Variety of Building Requirements <br />Product Applications <br />High-performance FOAMULAR 150 <br />works to: <br />• Retard the transmission of water vapor <br />and moisture in masonry walls, helping <br />prevent structural damage. <br />• Provide insulation in a metal or wood <br />furring system used for masonry or <br />concrete walls. <br />• Perform below grade in perimeter and <br />foundation applications, or on -grade <br />directly beneath the concrete slab to <br />complement the insulating sheathing <br />envelope around the building framing. <br />Resistant to common soils and decay, <br />Owens Corning FOAMULAR retains its <br />insulating performance characteristics even <br />after prolonged exposure to moisture. <br />Standards and Codes Compliance <br />• Recognized by code authorities under <br />Research Reports BOCA 91-54; <br />ICBO 3628; SBCCI PST & ESI 9727 <br />• Meets HUD/FHA Use of Materials <br />Bulletin No. 71 and ASTM C 578-92 <br />Type X <br />• Underwriters Laboratories, Inc., <br />Classification Certificate U-197 <br />• Thermal resistance: 5.0 at 75 °F, <br />5.4 at 40 *F mean temperature and <br />1" thickness (hr x ft' x °FBtu) <br />FOAMULAR 150 <br />Rigid Foam Insulation <br />Technical Information <br />• FOAMULAR insulation is ideal for all <br />buildings under normal temperature <br />conditions, but should not be used in <br />contact with chimneys, heater vents, <br />steam pipes or other surfaces where <br />temperatures exceed 150-F. It is not <br />recommended for applications where <br />sustained temperatures exceed 165'F. <br />• All construction should be evaluated for <br />the necessity to provide vapor retarders. <br />See current ASHRAE Handbook of <br />Fundamentals. <br />• FOAMULAR insulation in a non- <br />structural material and must be installed <br />on framings which are independently <br />structurally adequate to meet required <br />construction and service loading <br />conditions. <br />*The higher the R-value, the greater the insulating power. Ask your seller for the fact sheet on R-values. <br />J► ALPHA <br />high pertormonce fabrics & composites <br />ALPHA ASSOCIATES. INC. • 145 LEHIGH AVE. • LAKEWOOD, NJ 08701 <br />T: 732.634.5700 • 800.831,6399 • F: 732.634.1430 <br />VR-R PLUS <br />DESCRIPTION <br />Reinforced Polypropylene Film - Metalized Polyester Film Laminate <br />APPLICATIONS <br />Metal Building Insulation Facing <br />CERTIFICATIONS <br />Meets all criteria for ASTM C1136 Types II, IV UL 723/ASTM E84, ULC-S102M fire testing <br />COMPOSITION <br />VALUES* <br />COMPONENT <br />DESCRIPTION <br />English <br />Metric <br />White Film <br />Polypropylene <br />0.0011 inch <br />28.0 micron <br />Adhesive <br />Flame Resistant <br />Reinforcement <br />Tri-directional Fiberglass <br />4/inch (MD) <br />20/100 mm (MD) <br />4/inch (CD) <br />8/100 mm (MD) <br />Film <br />Polyester <br />0.0005 inch <br />12.7 micron <br />TYPICAL PHYSICAL PROPERTIES <br />VALUES* <br />CHARACTERISTIC <br />METHOD <br />ENGLISH <br />METRIC <br />BASIS WEIGHT <br />Scale <br />13.2 Ibs/1000 SF <br />64.1 g/SM <br />THICKNESS <br />ASTM-D-1777 <br />0.007" <br />178 microns <br />PERMEABILITY (WVTR) <br />ASTM-E-96 <br />0.02 Perms <br />1.15 ng/N's <br />BURST STRENGTH <br />ASTM-D-774 <br />100 psi <br />7.0 kg/cm2 <br />PUNCTURE RESISTANCE ASTM-C-1136 <br />300 units (79 in-Ibs) <br />9.0 Joules <br />TENSILE STRENGTH <br />ASTM-C-1136 <br />30 Ibs/inch MD <br />5.25 kN/m <br />30 Ibs/inch CD <br />5.25 kN/m <br />ACCELERATED AGING <br />30 days @ <br />No Corrosion <br />No Corrosion <br />95% RH, 120 °F (49°C) <br />No Delamination <br />No Delamination <br />TEMPERATURE RESISTANCE <br />-40 °F to 220 °F <br />-40 °C to 104 °C <br />WATER IMMERSION <br />24 hours @ 73°F (23°C) <br />No Delamination <br />No Delamination <br />MOLD RESISTANCE <br />ASTM-C-665 <br />No Growth <br />No Growth <br />LIGHT REFLECTIVITY <br />ASTM-C-523 <br />85% <br />85% <br />Physical properties are based upon nominal values. <br />Weight / Thickness +/- 10% <br />FIRE TESTING <br />UL723/ASTM E84/CAN ULC-S102M <br />Composite <br />FLAME SPREAD <br />25 <br />SMOKE DEVELOPED <br />50 <br />DATA SHEET q 13662 REV. I DATE: 12/10/14 *All values are nominal unless otherwise specified. <br />Note: Alpha's metal building insulation facings are produced with plastic films containing ultraviolet (UV) inhibitors, however, <br />intense exposure to UV sources such as direct or indirect sunlight and/or high -output UV lighting is not recommended as <br />these will degrade the plastic film facing. <br />FOAMULAR 150 Rigid Foam Insulation <br />FOAMULAR Physical Properties"' <br />Product Data <br />Caution <br />Product /Values <br />Foamular Insulation Product- 150 (15psi)"' <br />This product will ignite if exposed to fire of <br />ASTM FOAMULARMaterial <br />"' Property Method 1500PYst <br />Extruded polystyrene closed -cell <br />Y <br />sufficient heat and intensity. This product <br />foam panel with continuous skins <br />should be installed only with a gypsum <br />Thermal conductivity - "k"' <br />on face and back surfaces <br />board on the interior side of the wall. <br />[Btu x in/ft' x hr x IF max] <br />@ 75°F mean temperature C518 0.20 <br />Width x <br />During shipping, storage, installation and <br />@ 40°F mean temperature 0.18 <br />Thkknesses"' (In) Lengthl"(In) Edges <br />use, this product should not be exposed <br />Compressive strength, <br />1, 1Y4 2, 2X, 3 16 x 96 Square <br />to open flame or other ignition sources. <br />Minimum (specification) D1621 15.0 <br />1, 1%, 2, 14, 3, 3Ye 24 x 96 Square <br />value (lb/in')"' <br />1, 1%, 2, 2 4, 3 48 x 96 Square <br />Note <br />Flexural strength <br />(lb/in' min)", C203 60 <br />1 48 x 108 Square <br />All products described here may not be <br />Water absorption <br />Scored <br />available in all geographic markets. <br />(% by volume max)", C272 0.10 <br />1, 1% 2, 2%, 3 48 x 96 Square <br />Consult your local sales office <br />Water vapor permeance <br />1, 1%, 2 24 x 96 T&G"' <br />representative for more information. <br />(perm max)'" E96 0.80 <br />1, 1%, 2 48 x 96 T&G'•' <br />Water affinity - hydrophobic <br />1 48x108 T&GGD <br />Technical Information: <br />Water capillarity - none <br />Weight Approximately 120-1301b1 <br />(800) 828-7155 <br />Dimensional stability <br />1,000 ft'' for 1" thickness <br />(% linear change max)'"' D2126 2.0 <br />Export Sales Office: <br />Linear coefficient of thermal <br />Packaging Shipped in units with two stretch- <br />(330) 633-1105 <br />expansion (in/ieF max) - 2.7xlW <br />wrap bands per bundle, with an <br />Flame spread"M1" E84 5 <br />additional exterior wrap <br />FOAMULAR insulation is produced by <br />Smoke developed""'°"I" E84 45-175 <br />FOAMULAR Insulation Product - CW-15 <br />Owens Corning's patented HYDROVAC• <br />Oxygen index min"' D2863 24 <br />I 1':- 2 16 x 96 Square <br />process technology. <br />(1) Properties shown are representative values for <br />I" thick material based upon most recent product <br />( I ) "R" per inch: 5.0 (at 75°F mean temperature). <br />For more information on the <br />quality audit data. (2) Modified as required to meet <br />(2) Other sizes available on request. Consult your <br />Owens Corning family of home building <br />ASTM C578-92. (3) Thermal resistance (R) - <br />(hr. x ft.' x *FBtu) -of a 1" thickness at 5.0 <br />local Owens Corning representative for availability. <br />(3) Compressive strength, minimumP <br />P S (specification) <br />roducts, contact our Owens Coming <br />Y g <br />(at 75•F mean temperature), 5.4 (at 40°F). (4) Value <br />value (lb/in'). (4) Tongue -and -groove edge reduces <br />dealer, call 1 - 8 0 0 - G E T - P I N K <br />at yield. (5) Value at yield or 5%, whichever occurs <br />air infiltration. <br />or access our Web site: <br />first. (6) Data ranges from 0.00 to value shown due to <br />Note: All products described here may not be <br />the level of precision of the test method. (7) Actual <br />available in all geographic markets. Consult your <br />w w w. o w e n s c o r n i n g. c o m <br />water vapor permeance data decreases as thickness <br />local Owens Corning sales office or representative <br />increases. (8) Data ranges from 0.0 to value shown. <br />for information. <br />(9) These laboratory tests are not intended to describe <br />the hazard presented by this material under actual fire <br />conditions. (10) Data from Underwriters Laboratories, <br />Inc! classified. See Classification Certificate U-197. <br />(11) ASTM E84 is thickness -dependent, therefore a <br />range of values is given. <br />�® SYSTEM THINKING <br />• :blokes the Differeurv'" <br />OWENS CORNING WORLD HEADQUARTERS <br />ONE OWENS CORNING PARKWAY <br />TOLEDO, OHIO 43659 <br />System Thinking- and System Thinking Makes the Difference" are trademarks of Owens Corning. <br />The color PINK is a registered trademark of Owens Corning. <br />0 & r'" designate names and products which are trademarks of Owens Corning. <br />Pub. No. 5-FO-23513-A Printed in U.S.A., October 2001 Copyright @ 2001 Owens Corning <br />Zabik Turner Engineering, PLLC <br />Jennifer Zabik, P.E., S.E. <br />1024 N Fullers Cross Road <br />Winter Garden, FL 34787 <br />j zabik@ztengineering.com <br />P-1294 <br />SEALS <br />.� ENS'° <br />No. M <br />5 <br />ST ty <br />' 10,VC / <br />� R10 <br />NAt- <br />RAPID <br />BUILDING SOLUTION'S, <br />3 5 0 E Crown Point Rd <br />Suite 1080 <br />Winter Garden, FL 34787 <br />Phone: (40 7) 34 7-9614 <br />Info@ <br />rapidbuildingsolutions. com <br />JOB NAME: <br />Zephyrhills Commons <br />38001 Pretty Pond Road <br />Zephyrhills, FL <br />JOB NUMBER: <br />268-19-ZEP-FL <br />REV <br />DATE <br />DESCRIPTION <br />APP <br />1 <br />11-28-19 <br />Layout Review <br />JL <br />0 <br />12-16-19 <br />Review <br />RG <br />1 <br />12-19-19 <br />RBS RL <br />RG <br />2 <br />12-20-19 <br />ZTE RL <br />RG <br />3 <br />01 <br />—21 —20 <br />CUST. REDLINES <br />RG <br />4 <br />01 <br />—22-20 <br />REVIEW <br />RG <br />5 <br />01 <br />—24-20 <br />HECTOR RL <br />AC <br />6 <br />03-08-20 <br />Review 1 <br />RC <br />ISSUE DATE: Novermber 28,2019 <br />DESIGNED BY: RBS DRAWN BY: JL <br />CHECKED BY: RBS SUBMITTED BY: CSD <br />8ft 4ft Oft 8ft 1 6ft <br />1 /8"=1 '—O" <br />DETAILS: NOT TO SCALE <br />APPROVED FOR PRODUCTION <br />INITIALS OF GC/OWNER <br />RBS-IN. I <br />