Laserfiche WebLink
02 <br />co <br />W <br />MOUNT* SURFACE <br />1201208 <br />I <br />3-PHASE, 4W <br />I <br />PANEL A <br />CAPACITY: 400A <br />INT CAP: 22KA <br />0) <br />W <br />"- <br />0 <br />LOCATION: BACK OF BLDG. <br />LUGS: MLO <br />DEMAND LOAD* 321A <br />AV. FAULT: 12 KA <br />I- <br />0 <br />CKT <br />LTG <br />REC <br />HVAC <br />MISC <br />NP <br />DESCRIPTION <br />AMP <br />POLE <br />� <br />AMP <br />POLE <br />DESCRIPTION <br />LTG <br />REC <br />HVAC <br />MISC <br />NP <br />CKT <br />1 <br />11.0 <br />RTUI <br />100 <br />3 <br />A <br />20 <br />1 <br />AUTOMATIC DOOR <br />0.1 <br />2 <br />C <br />3 <br />11.0 <br />8 <br />20 <br />1 <br />PHONE BOARD/BUZZER <br />OA <br />4 <br />C <br />5 <br />11.0 <br />C <br />20 <br />1 <br />ENERGY MANAGEMENT <br />0.2 <br />6 <br />C <br />7 <br />1 <br />11.01 <br />RTU2 <br />1001 <br />3 <br />A <br />20 <br />1 <br />SPARE <br />8 <br />9 <br />B <br />20 <br />1 <br />OUTDOOR HVAC REC <br />0.7 <br />10 <br />11 <br />11.0 <br />C, <br />20. <br />1 <br />OUTDOOR DRINK VEND <br />0.2 <br />12 <br />13 <br />SPARE <br />20 <br />1 <br />A <br />20 <br />1 <br />SPARE <br />14 <br />15 <br />SPARE <br />20 <br />1 <br />B <br />20 <br />1 <br />SPARE <br />16 <br />17 <br />SPARE <br />20 <br />1 <br />C <br />20 <br />1 <br />INTERFACE EQUIP <br />0.5 <br />Is <br />C <br />19 <br />1.7 <br />WATER HEATER #1 <br />20 <br />1 <br />A <br />20 <br />1 <br />VSATSATA HUB EQUIP <br />0.5 <br />20 <br />C <br />21 <br />1.7 <br />WATER HEATER #2 <br />20 <br />1 <br />IBI <br />20 <br />1 <br />CCTV EQUIP <br />1.0 <br />22 <br />23 <br />0.2 <br />DRINKING FOUNTAIN <br />20 <br />1 <br />C <br />20 <br />1 <br />SECURITY REC <br />0.2 <br />24 <br />C <br />25 <br />0.2 <br />OUTDOOR ICE REC <br />-R <br />20 <br />1 <br />A <br />20 <br />1 <br />OFFICE REC <br />0.7 <br />26 <br />C <br />21 <br />w5 <br />3 L-Wilm' r' <br />'2-r <br />2 <br />',-C <br />B <br />20 <br />1 <br />BREAK ROOM REC <br />0.5 <br />28 <br />29 <br />2.5 <br />20 <br />1 <br />OFF/BREAKRM RECEPT <br />0.9 <br />30 <br />C <br />31 <br />3,2 <br />4 DOOR LOW TMP <br />40 <br />2 <br />A <br />20 <br />1 <br />BEAUlrf1COSMEnCS <br />0.4 <br />32 <br />33 <br />32 <br />B <br />20 <br />1 <br />ICE CREAM FREEZER <br />0.8 <br />34 <br />C <br />35 <br />SPARE <br />20 <br />1 <br />C <br />20 <br />1 <br />GATORADE RECEPT <br />0.6 <br />36 <br />C <br />SFIA <br />2 <br />-1 <br />A <br />200 <br />3 <br />PANEL B <br />38 <br />39 <br />SPARE <br />20 <br />'t <br />B <br />11.2 <br />1 0.0 <br />0.1 <br />26.2 <br />0-0 <br />40 <br />41 <br />SPARE <br />20 <br />1 <br />C <br />I <br />PHASE BALANCE <br />LOAD TYPE <br />CONNECTED <br />DEMAND <br />DEMAND FORMULA <br />TOTAL LOAD <br />LIGHTING <br />11.2 KVA <br />14-0 KVA <br />LOAD X 1251/6 NEC 210.19 CONTINUOUS <br />CONNECTED <br />DEMAND <br />LOAD <br />% <br />RECEPTACLE <br />4-9 KVA <br />4.9 KVA <br />I OKVA + 500% REMAINDER NEC 220 A4 <br />126.1 KVA <br />11 &7KVA <br />* <br />28.8 KVA <br />23% <br />AC <br />66.1 KVA <br />52.9 KVA <br />LOAD X 80% (USED MCA IN CALCULATION) <br />350.OA <br />321.1A <br />* <br />70.3 KVA <br />56% <br />MISC <br />43.9 KVA <br />43.9 KVA <br />LOAD X 100% NEC 210.19 NON-CONT. <br />FILENAME: <br />C <br />1 27.0 KVA <br />. 21% <br />NP <br />0.0 KVA <br />0.0 KVA <br />0 NONCOINCIDENTAL LOADS NEC 220-60 <br />DGZephyrhills FLPaneISc1 <br />NOTES: <br />A. AIC RATING: SERIES RATED AT 200,000 AMPS WITH BUSSMANN JJN FUSES. <br />B. BREAKERS FOR HVAC UNITS SHALL BE SIZED PER MANUFACTURER REQUIREMENTS. ENTS. <br />C. BREAKER LOCK <br />D. ISOLATED GROUND BUS. <br />EQUIPMENT <br />SCHEDULE <br />PLAN <br />MARK <br />EQUIPMENT <br />SERVED <br />LOAD <br />VOLTI <br />PHASE <br />FED <br />BY <br />I DISC <br />BY <br />MCA <br />MOCPD <br />FEEDER <br />REMARKS <br />RTU I <br />ROOFTOP UNIT <br />33.10KVA <br />20813 <br />A <br />EC <br />92.OA <br />100A <br />(3)#3,#100,1 1/4 "C <br />PROVIDE100A/3P NIF <br />DISCONNECT <br />RTLI 2 <br />I <br />ROOF TOP UNIT <br />f <br />33.10KVA <br />20813 <br />I <br />A <br />EC <br />92.OA, <br />I <br />100A <br />I <br />(3)#3, #100,1 1/4 "C <br />I <br />PROVIDE 100A13P NF <br />IDISCONNECT <br />I FILENAME: <br />DG Zaphyrhills FL Panel <br />Schedules.xis <br />I <br />1201208 <br />3-PHASE, 4W <br />PANEL LOAD <br />I CAPACITY: 400A <br />LOAD TYPE <br />CONNECTED <br />DEMAND <br />DEMAND FORMULA <br />LIGHTING <br />11.2 KVA <br />14.0 KVA <br />LOAD X 125% NEC 210.19 CONTINUOUS <br />RECEPTACLE <br />4.9 KVA <br />4.9 KVA <br />I OKVA + 60% REMAINDER NEC 220.44 <br />HVAC <br />66.1 KVA <br />52.9 KVA <br />LOAD X 80% (USED MCA IN CALCULATION) <br />MISC <br />43.9 KVA <br />43.9 KVA <br />LOAD X 100% NEC 210.19 NO WCONT. <br />NP <br />0.0 KVA <br />0.0 KVA <br />10 NONCOINCIDENTAL LOADS NEC 220.60 <br />400A DISCONNECT: PROVIDE 600V/3P, <br />400A/400A BUSSMANN JJN FUSES IN MAIN <br />HEAVY DUTY SERVICE DISCONNECT <br />SWITCH. COORDINATE LOCATION WITH <br />UTILITY COMPANY AND DOLLAR GENERAL. <br />AVAILABLE SHORT <br />CIRCUIT (TYPICAL) 9,753 <br />(2) SETS OF (4)#3/0 CU, 2-1/2"C � <br />CT'S/ METER CABINET <br />PER UTILITY COMPANY <br />REQUIREMENTS <br />(3) SETS OF (4)#500, AL, T-C UNDERGROUND <br />SERVICE ENTRANCE PER UTILITY AND SITE <br />SPECIFIC CONDITIONS. REFER TO SHEET ES1 <br />FOR LOCAL UTILITY CO. POLE/TRANSFORMER <br />LOCATION. G.C. SHALL COORDINATE WITH <br />CIVIL FOR THE EXACT LOCATION OF THE POLE <br />MOUNTED TRANSFORMERS AND MAKE ANY <br />CHANGES TO THE SERVICE ENTRANCE WIRING <br />SIZE IF THE CONNECTION POINT IS DIFFERENT <br />THAN WHAT IS SHOWN. <br />NOTE: REFER TO THE ELECTRICAL <br />SPECIFICATIONS ON SHEET El FOR <br />CONDUCTOR TYPES AND INSULATION. <br />1/0 SYSTEM GROUND, <br />SEE DETAIL #2/E6 <br />EXTERIOR <br />(4)#3/0 CU, #6G, #61G, 2-1/2"C <br />A 8 <br />N 9,311 . N <br />G G <br />IG IG <br />9,601 <br />(2) SETS OF (4)#3/0 CU, <br />#3G, #31G, EACH IN 3"C <br />INTERIOR <br />-ELECTRICAL PANEL SCHEMATIC <br />Scale: NTS <br />MOUNT: SURFACE <br />1 120/208 <br />3-PHASE,-4W <br />PANEL B <br />CAPACITY: 200A <br />INT CAP: 22KA, <br />0 <br />LOCATION: BACK OF BLDG. <br />LUGS: MLO <br />DEMAND LOAD: 112A <br />AV. FAULT: 12KA <br />0 <br />CKT <br />LTG <br />REC <br />WAC <br />MISC <br />NP <br />DESCRIPTION <br />AMP <br />POLE <br />Q_ <br />AMP <br />POLE <br />DESCRIPTION <br />LTG <br />REC <br />HVAC <br />MISC <br />NP <br />CKT <br />B,C <br />I <br />OA <br />NIGHT LTS <br />20 <br />1 <br />A <br />20 <br />1 <br />PWR TERM BROW N <br />1.2 <br />2 <br />C <br />B,C <br />3 <br />02 <br />RECEIVING LTS <br />20 <br />1 <br />B <br />20 <br />1 <br />PWR TERM BROWN <br />1.2 <br />4 <br />C <br />B <br />5 <br />0.8 <br />704/a SALES LTS <br />20 <br />1 <br />C <br />20 <br />1 <br />PWR TERM GREEN <br />1.2 <br />6 <br />C <br />B <br />7 <br />0.9 <br />1 <br />1 <br />701% SALES LTS <br />20 <br />1 <br />1 A <br />20 <br />1 <br />PWR TERM GREEN <br />1.2 <br />8 <br />C <br />B <br />9 <br />1 1.4 <br />70% SALES LTS <br />20 <br />1 <br />B <br />20 <br />1 <br />PWR TERM GREEN <br />1.6 <br />10 <br />C <br />B <br />11 <br />1-3 <br />70% SALES LTS <br />20 <br />1 <br />C <br />;A, <br />1, <br />1121- <br />1jr__ <br />B <br />13 <br />1.4 <br />30% SALES LTS <br />20 <br />1 <br />At <br />20 <br />1 <br />COLD DRINKS COOLER <br />0.8 <br />14 <br />C <br />B <br />15 <br />0.6 <br />30% SALES LTS <br />20 <br />1 <br />Ell� <br />20 <br />1 1 <br />2 DOOR STAND ALONE <br />1 <br />0.8 <br />16 <br />C <br />17 <br />SPARE <br />20 <br />1 <br />20 <br />2 <br />1 <br />MAX COLD FREEZER <br />0-9 <br />is <br />C <br />C <br />19 <br />0.1 <br />EPA ERGENCYIEXIT LTS <br />20 <br />1 <br />_C1 <br />A0.9 <br />20 <br />C <br />C <br />21 <br />0.2 <br />0.1 <br />BREAK[OFFICELTS/EFS <br />20 <br />1 <br />40 <br />2 <br />4 DOOR LOW TEMP <br />3-2 <br />22 <br />B <br />23 <br />0.3 <br />BUILDING SIGN <br />20 <br />1 <br />1 <br />3.2 <br />24 <br />B <br />25 <br />0.9 <br />PYLON SIGN <br />20 <br />1 <br />1 <br />15 <br />2 <br />5 DOOR MID TEMP <br />1.3 <br />26 <br />C <br />1 <br />B <br />27 <br />SPARE <br />20 <br />1 <br />1 k <br />1 <br />1.3 <br />28 <br />B <br />1 29 <br />1 02 <br />SITE LIGHTING <br />20 <br />2 <br />C <br />15 <br />2 <br />5 DOOR MID TEMP <br />- - - - - - <br />1.3 <br />30 <br />C <br />31 <br />0.2 <br />A- <br />1.3 <br />32 <br />B <br />33 <br />0.8 <br />EXTERIOR LTS <br />20 <br />1 <br />B <br />20 <br />1 <br />SODA COOLERS <br />1.6 <br />34 <br />C <br />B <br />35 <br />0.7 <br />FRNTWALUCANPYLTG <br />20 <br />1 <br />C <br />20 <br />1 <br />DRINK COOLERS <br />1.6 <br />36 <br />C <br />B <br />39 <br />SPACE <br />B <br />SPACE <br />40 <br />B <br />41 <br />0.8 <br />EXTERIOR DUSK/DAWN <br />20 <br />1 <br />C <br />SPACE <br />II <br />PHASE BALANCE <br />LOAD TYPE <br />CONNECTED <br />DEMAND <br />DEMAND <br />FORMULA <br />TOTAL LOAD <br />LIGHTING <br />11.2 KVA <br />14.0 KVA <br />LOAD X 1251% NEC 210.19 CONTINUOUS <br />CONNECTED <br />DEMAND <br />-5 <br />LOAD <br />% <br />RECEPTACIL E <br />0.0 KVA <br />0.0 KVA <br />I 0KVA + 50% REMAINDER NEC 220.44 <br />37.5 KVA <br />40_3KVA <br />A <br />10.6 KVA <br />2 8% <br />HVAC <br />0.1 KVA <br />0.1 KVA <br />LOADX80% (USED MCA IN CALCULATION)( <br />104AA <br />11 1.8A <br />B <br />13.0 KVA <br />351% <br />MISC <br />262 KVA <br />26.2 KVA <br />LOAD X 100% NEC 210.19 NON-CONT. <br />FILENAME: <br />C <br />13.9 KVA <br />37% <br />NP <br />0.0 KVA <br />0.0 KVA <br />0 NONCOINCIDENTAL LOADS NEC 220.60 <br />DGZephyrhills FL Panel Scl <br />NOTES: <br />A. AIC RATING: SERIES RATED AT 200,000 AMPS WITH BUSSMANN JJN FUSES. <br />B. ROUTING TO THE EMS PANEL.02 <br />C. BREAKER LOCK. <br />D. ISOLATED GROUND BUS_ <br />This ih-ouid-b-eChiGe-to-iine These are uncoated copper or aluminum <br />voltage for multi -voltage and conductor sizes with CU/AL 60C AmP8cItY Load current in amperes <br />3 phase systems. For a listed at 30C ambient for reference, <br />120/240V single phase system <br />select 240V. For other single <br />phase systems select the line- [jiurjWtZr conductor �Uc!�� <br />to -neutral voltage. <br />IV <br />gT-p-hasez �_V NEC tables assume'/ pper�tiug <br />temperature. If conductor Is oversized a <br />lower temperature can be used but this <br />temperature should always be higher than <br />ambient. This value only used for adjusting <br />conductor resistance. <br />LpyC..cqnduii <br />conductors per pi �n rallel <br />See NOTE I below <br />Length of cable In feet done -way distance) <br />---- - ------ Calculate Vc:�I�D� Reset <br />Estimated voltage drop <br />See NOTE 2 below <br />SERVICE FEEDER VOLTAGE DROP <br />Scale: NTS <br />02 <br />02 <br />Available Fault Current Calculation <br />t� =mar Ver. 6.6 <br />Utility Symmetrical Fault Current amperes <br />kVA <br />= 150 <br />E <br />= 208 <br />1 = kVA x 1000 = trans. FLA trans. FLA <br />416 <br />E x 1.732 <br />Isca trans. FLA x 100 x PF <br />PF <br />1 100%1 <br />transformer Z <br />Z <br />2.00kloI <br />Isca = ampere short-circuit current RMS symmetrical. <br />lxa <br />20,819 amperes <br />Point to Point Method <br />Three Phase 208/120 <br />--- <br />Length (distance) FEET <br />w] L <br />Aluminum in Nonmetallic Raceway <br />. ......... ................................ . .... <br />1.732 x L x I (ASC) <br />6- <br />.. <br />20,819 <br />N x C x E L-N # conductors per phase <br />N <br />=1 31 <br />Phase conductor constant <br />C <br />21,3911 Phase Conductor 500kcmil <br />.... ... .. ..... <br />Volt Line to Line <br />tL-L <br />= Volt <br />f <br />= 1.108 <br />Neutral conductor carts#ant <br />C <br />= 21,391 INeutral Conductor Soo kcrnil <br />Multiplier Volt Lme to Neutral <br />E _N <br />= 120 Volt <br />f <br />M= 1 <br />1+f Line to Line <br />M <br />0.474 Fault Current from <br />Line to Neutral <br />M <br />0.342 Transformers to <br />Fault Current at Service Equipment I <br />Main Disconnect witch <br />Isca ,.. fault current at terminals of main disconnect L- L <br />0 9,878 amperes <br />Isca... fault current at terminals of main disconnect L- N <br />to 7,130 amperes <br />Fault Current from <br />Copper Lm Metal Raceway • <br />Three Phase <br />Three Phase Feeder <br />Length (distance) <br />L <br />1.732 x L x I <br />(ASC) <br />Isca <br />= 9,878 Phase 7,130 Neutral <br />N xCx EL-N <br /># conductors per phase <br />N <br />=2 <br />EJ <br />Phase conductor constant <br />C <br />12,84� Phase Conductor 310 1W <br />Volt Line to Line <br />EL-L <br />= 208 Volt <br />f <br />= 0.016 <br />Neutral conductor constant <br />C <br />= 1r844 Neutral Conductor 3j0 ................ <br />Volt Line to Neutral <br />EL-N <br />= 120 Volt <br />Multiplier <br />f <br />= 0.020 <br />M I <br />Line to Line <br />M <br />0.984 Fault Current at <br />I+f <br />Line to Neutral <br />M <br />0.980 Panel 'A' <br />Isca x M = fault current at <br />terminal of the panel L- L = <br />9,722 amperes <br />Isca x M = fault current at terminal of the panel L- N = <br />6,990 amperes <br />Iranch Circuit Fault from <br />copper in meal Raceway <br />- - ---------- -- . ..... <br />Three Phase Branch <br />Length (distance) <br />L <br />Three Phase <br />=5 <br />1,732 x L x I <br />(ASC) <br />Isca <br />9,722 Phase 6,990 Neutral <br />N x C x E L-N <br /># conductors per phase <br />N <br />f I <br />Phase conductor constant <br />C <br />=L12,844 / JPhase Conductor 30 <br />Volt Line to Line <br />EL-L <br />= 208 Volt <br />f <br />= 0.032 <br />Neutral conductor constant <br />C <br />= [_12,8441 Neutral Conductor 3/0 <br />Volt Line to Neutral <br />EL-N <br />120 Volt <br />Multiplier <br />f <br />0.039 <br />M= I <br />Line to Line <br />M <br />0.969 Fault Curren at <br />I + f <br />Line to Neutral <br />Mt <br />0.962 Panel 'B' <br />Isca x M = fault current at terminal of the panel L- L = <br />9,425 amperes <br />Isca x M = fault current at terminal of the panel L- N = <br />6,726 amperes <br />FAULT CURRENT CALCULATION <br />Scale: NTS <br />MAIN BONDING JUMPER NEUTRAL BUS <br />BARE COPPER <br />CONDUCTION GROUND BUS (1)#6 TO PHONE BOARD <br />PER NEC 800-40(D) <br />MINIMUM OF 20'-0" OF 1/2" <br />REBAR IN BUILDING WALL <br />FOOTING, (NEC 250-50C) - <br />BARE COPPER GROUNDING <br />ELECTRODE CONDUCTOR <br />(NEC 250-66) <br />\_CADWELD BONDING JUMPER TO <br />PANELBOARD ENCLOSURE SIZE <br />CADWELD PER NEC 250-122 <br />OPTIONAL FOR EXISTING <br />SLAB LIFER. 3/4" X 10' <br />GROUND ROD (NEC VALVE, <br />250-52) METER SUPPLY <br />OR SIDE <br />UNION <br />BUILDING STRUCTURAL <br />STEEL (NEC 250-52(A)(2) <br />PIPE CLAMP <br />ENTRANCE (PROVIDE SIMILAR (TYP.) CADWELD <br />COLD WATER SERVICE <br />CONNECTION TO FIRE <br />PROTECTION WATER SERVICE <br />ENTRANCE), (NEC 250-50A) JUMPER <br />NOTE: ALL GROUNDING SHALL BE INSTALLED <br />IN ACCORDANCE WITH ARTICLE 250 OF THE <br />NATIONAL ELECTRICAL CODE. <br />GROUNDING DETAIL <br />Scale: NTS <br />CONSULTANT: <br />SEAL: SEAN PATRICK PIC-KELL, PE 83946 <br />``RICK P/ <br />E N <br />Z Do No.83946 <br />_0. STATE OF <br />10p. <br />11 <br />A A <br />THIS DRAWING SHALL NOT BE USED FOR <br />CONSTRUCTION PURPOSES UNTIL THE SEAL AND <br />SIGNATURE OF THE RESPONSIBLE REGISTRANT <br />APPEARS ON THE DRAWING, AND PROPER PERMIT <br />FORMS AND RELATED FEES ARE TRANSMITTED BY <br />THE OWNER, OWNERS AGENT OR CONTRACTOR <br />TO THE AUTHORITY HAVING JURISDICTION. <br />DATE <br />ISSUED FOR <br />REV <br />09/27/2018 <br />PEMB COORDINATION <br />12/18/2018 <br />PERMIT SUBMITTAL <br />01/11/2019 <br />OWNER REVIEW <br />02/07/2019 <br />BID SET <br />03/04/2019 <br />ADDENDUM 01 <br />06/07/2019 <br />BULLETIN 01 <br />02 <br />Project Manager <br />Drawn <br />L. LONG <br />G. COLLINS <br />Project Leader <br />Checked <br />L. LONG <br />M. GOOD <br />Date <br />Dept Mgr Approval <br />08/07/2018 <br />M. GOOD <br />Client <br />PALMETTO ZEPHYRHILLS-20th St, LLC <br />P.O. BOX 1615 <br />THOMASVILLE, GA 31792 <br />Office: (229) 226-0682 <br />Contact: John Tate <br />Project <br />DOLLAR GENERAL <br />38965 CR 54 <br />Zephyrhills, FL 33542 <br />(City of Zephyrhills) <br />Store #: 20360 <br />Drawing Title <br />THREE PHASE <br />ELECTRICAL PANELS <br />DO NOT SCALE DRAWING <br />Project No. <br />Drawing No. <br />JCDT. 18.02 3 3 <br />E5 <br />