GENERAL NOTES <br />EXISTING ROOFING NOT CHANGED <br />'DATE: <br />5-20-14 <br />The structure is designed to be self-supporting and stable after <br />the building is fully completed. It is solely the contractor's <br />responsibility to determine erection procedure and sequence and to <br />Insure the safety of the building and its component parts during <br />erection, This includes the addition of whatever shoring, <br />sheeting, temporary bracing, guys or tiedowns which might be <br />necessary, <br />It Is solely the contractors responsibility to follow all op- <br />plicable safety codes and regulations during all phases of con- <br />struction. <br />Should any of the detailed instructions shown on the plans con- <br />filct with the general structural notes, the specifications or <br />with each other, the strictest provision shall govern, <br />The general contractor shall be responsible for verifying all <br />dimensions and elevations shown on the plans and for coordinating <br />all dimensions and elevations shown on the structural drawings <br />with those shown on the architectural and mechanical drawings. If <br />discrepancies in the dimensions occur, it shall be the <br />contractor's responsibility to bring the discrepancy to the at- <br />tention of the architect before proceeding with the work, <br />Unless noted otherwise, requirements given for one or more loca- <br />tlons also apply at other locations at which conditions are <br />similar, The requirements given shall be adopted to conditions at <br />such other locations, <br />The site shall be graded to provide drainage away from the structure, <br />This structure not designed to resist additional wind loads imposed by the <br />installation of wall panels & framing not shown on this plan, <br />CONCRETE NOTES <br />All concrete work shall conform to the building code requirements <br />for reinforced concrete (ACI 318-89) and specifications for <br />structural concrete for buildings (ACI 301-84) of the American <br />Concrete Institute, <br />Provide at least one copy of the ACI Field Reference Manual, SP- <br />15, in the field office at oil times, <br />All reinforcing steel shall be ASTM A615 Grade 60, <br />C,I,P, concrete construction or control Joints in slab on grade to <br />be as shown on plans. Where not shown, limit control Joint <br />spacing to no greater than 15 feet on any side for 5 Inch slabs <br />and 12 feet for 4 Inch slabs an grade, The sections bounded by <br />control or construction Joints shall be approximately square, with <br />the length to width ratio less than 1,5, <br />Coordinate concrete work with architectural drawings and <br />specifications for architectural finished concrete, recessed <br />areas, embedded items, and special control Joints, <br />Structural lumber design and construction shall conform to <br />ANSI/NFoPA NOS-1991 National Design Specification for wood <br />construction, <br />Wood product sizes ore stated In terms of standard nominal +sizes. <br />Design values ore opplleable to lumber that will be used under dry <br />conditions such as In most covered structures, <br />Design values used are for normal load duration, <br />All structural wood members shall be Visually Graded Southern Pine <br />Dimension Lumber No. 2 Minimum Grade unless otherwise indicated. <br />Wood members shall be pressure treated where In contact with poured <br />concrete, soil, masonry, or where otherwise indicated, <br />Lumber shall be so handled and covered as to prevent marring, and <br />moisture absorption from rain, <br />AND REPLACED WITH NEW PRECAST LINTEL SUPPORTED <br />ON EITHER END BY 8" BEARING ON CMU BELOW, LINTEL <br />TO BE FILLED SOLID AND HAVE 1-#5 CONT, INSIDE, TO <br />BE TIED INTO CELL TO EITHER SIDE OF OPENING, IF CELLS <br />UNDER LINTEL ARE NOT POURED SOLID THEY MUST BE, EA. <br />CELL MUST HAVE #5 DRILLED INTO SLAB BELOW AND INTO <br />BOND BEAM ABOVE, TO BE SET INTO THEM WITH SIMPSON <br />2-PART BONDING EPDXY OR EQUAL. DRILL 3/4"X6" HOLE IN <br />EA, AND FILL W/ EPDXY, <br />EXISTING 2"X ROOF FRAMING NOT CHANGED <br />EXISTING ROOFING NOT CHANGED <br />ALL CELLS TO BE FILLED OVER NEW BEAM <br />EXISTING C,M,U. WALL TO BE SUPPORTED BY NEW STEEL BEAM <br />SECURE TO NE BEAM W/ 1/2 X6" TITAN ANCHORS 24" O.C. <br />'TING 2 X ROOF FRAMING NOT CHANGED STAGGER EA. SIDE OF WEB <br />NEW W12X30 STEEL WIDE FLANGE BEAM TO BE INSTALLED <br />TO SUPPORT REMAINDER OF EXISTING WALL AND ROOF, <br />1 /2" THRU BOLTS TO 2-2"X LEDGER 48" OC, SET BOTTOM OF WOOD ON <br />INSTALL NEW HUS26 JOIST HANGERS BOTTOM FLANGE OF BEAM <br />0 EA. EXISTING RAFTER 2"X8" SHOT TO BOTTOM FLANGE OR BOLTED W/3/8" 48" OC„ <br />SECTION <br />SCALE 1" - 1' 0' <br />EXISTING 8" C.M,U, WALL TO BE INSULATED <br />W/ R5 RIGID INSULATION AND FURRED OUT <br />WITH 1"X2" (MIN,) P,T, FURRING STRIPS <br />WARNING; DO NOT SCALE DRAWINGS USE DIMENSIONS AS SHOWN OR CALL DESIGNER WITH OUESTIONSII SCALE 1 /4" = 1' <br />FxIgTING ROOFING NOT CHANGED <br />XISTING 2"X ROOF FRAMING NOT CHANGED <br />ALL CELLS TO BE FILLED OVER NEW BEAM <br />EXISTING C,M,U, WALL TO BE SUPPORTED BY NEW STEEL BEAM <br />SECURE TO NE BEAM W/ 1 /2"X6" TITAN ANCHORS 24" O.C. <br />STAGGER EA, SIDE OF WEB <br />W12X30 STEEL WIDE FLANGE BEAM TO BE INSTALLED <br />1UPPORT REMAINDER OF EXISTING WALL AND ROOF, <br />SECTION 2 <br />_Q <br />SCALE V 1'-0' <br />ALL CELLS TO BE FILLED OVER NEW BEAM <br />EXISTING C,M,U, WALL TO BE SUPPORTED BY NEW STEEL BEAM <br />SECURE TO NE BEAM W/ 1 /2"X6" TITAN ANCHORS 24" O.C, <br />STAGGER EA, SIDE OF WEB <br />6"X6"X1/2" STEEL PLATE WELDED TO <br />STEEL COLUMN AND BOLTED TO 1 BEAM <br />ABOVE WITH 4-1/2" THRU BOLTS <br />6"X6"X1/2" STEEL PLATE WELDED <br />TO STEEL COLUMN AND SECURED <br />TO SLAB WITH 4-1 /2"X6" TITAN <br />ANCHORS, <br />NEW W12X30 STEEL WIDE FLANGE <br />BEAM TO BE INSTALLED <br />TO SUPPORT REMAINDER OF <br />EXISTING WALL AND ROOF, <br />3"X3"X1 /4" STEEL TUBE COLUMN <br />EXISTING SLAB AND FOOTERS <br />SECTION <br />SCALE 1" = 1'-0' 3 <br />NOTE: <br />WHILE EVERY EFFORT HAS BEEN TAKEN TO AVOID <br />OMISSIONS AND ERRORS, MICHAEL MARTIN DESIGN <br />AND IT'S AGENTS CANNOT GUARANTEE AGAINST <br />HUMAN ERROR, CONTRACTOR MUST VERIFY ALL LOCATIONS, <br />FINISHES, DIMENSIONS, AND SPECIFICATIONS PRIOR <br />TO CONSTRUCTION OF STRUCTURE, <br />HEREBY CERTIFY THAT I HAVE REVIEWED <br />THE ATTACHED DESIGN AND FOUND IT TO BE <br />IN COMPLIANC ASCE 7-10 AND THE <br />FLORID/k'B DIN.-eBDE 2010 ED. <br />s <br />-z" .1 , <br />DAVID W, SMIT 53608 <br />SOS <br />CID <br />O <br />p <br />>� <br />J <br />v <br />i%n <br />1--i <br />N <br />Q <br />Ln <br />® <br />00 <br />II® <br />O <br />z <br />1 <br />p <br />CN <br />CN <br />(!')��� <br />Q <br />I <br />c <br />o <br />N <br />N <br />Ln <br />LLI <br />w �CnWU <br />z <br />O <br />LL <br />X <br />� <br />C) <br />< <br />.L <br />Q <br />z <br />w <br />C� <br />E <br />O <br />04 <br />Z 0 <br />LiJ <br />O <br />C <br />U <br />U;:Jcc:,) <br />wxL` <br />a <br />4d M <br />o� <br />z O <br />E-o <br />CD <br />I— L z E <br />N <br />UA <br />W <br />Q o <br />CLu� <br />o <br />W <br />E <br />Checked By: <br />Q, U w4tn <br />Drawn By: �� <br />� � alr4l n <br />Job No: <br />14035 <br />S2OF <br />