Laserfiche WebLink
Q <br />1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 13 1 14 1 15 1 16 1 17 1 18 <br />.w . <br />t <br />r <br />19 1 20 <br />P <br />0 <br />N <br />M <br />L <br />K <br />J <br />H <br />G <br />F <br />E <br />u <br />C <br />B <br />A <br />PLUMBING PROJECT NOTES <br />1. THE CONTRACTOR SHALL ARRANGE AND PAY FOR ALL PERMITS <br />14. SANITARY PIPING SCHEDULES: <br />AND INSPECTIONS REQUIRED IN THIS WORK. <br />A) VENTS - SCHEDULE 40 PVC DWV. <br />2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, <br />B) BUILDING DRAIN -SCHEDULE 40 PVC DWV. <br />SPECIFICATIONS, LOCAL, STATE AND NATIONAL CODES. CERTIFICATES <br />OF INSPECTION, WHERE REQUIRED, SHALL BE OBTAINED AND PAID <br />15. DOMESTIC WATER PIPING SCHEDULES: <br />FOR BY THIS CONTRACTOR AND FURNISHED TO THE TENANT. <br />INTERIOR ABOVE GRADE - TYPE "L" HARD DRAWN COPPER <br />TUBE. <br />3. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, <br />EXTERIOR BELOW GRADE - TYPE "K" HARD DRAWN COPPER <br />EQUIPMENT AND TOOLS TO PERFORM MECHANICAL WORK AS SHOWN, <br />TUBE WITH FLARED FITTINGS. <br />NOTED OR SCHEDULED FOR A COMPLETE INSTALLATION. <br />16, ALL VALVES AND SPECIALTY ITEMS MAY NOT BE SHOWN IN <br />4. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND COMMERCIAL <br />EVERY INSTANCE ON THE DRAWINGS, BUT ARE TO BE PROVIDED <br />GRADE. <br />WHETHER SHOWN OR NOT WHEN NECESSARY FOR PROPER <br />OPERATION AND MAINTENANCE OF THE SYSTEM. UNLESS <br />5. THE CONTRACT DRAWINGS INDICATE THE EXTENT AND GENERAL <br />OTHERWISE NOTED, VALVES AND SPECIALTY ITEMS ARE TO BE <br />ARRANGEMENTS OF EQUIPMENT AND SYSTEMS. IF ANY DEPARTURES <br />RATED AT 125 PSIG. DEVICES AND VALVES 2 1/2" AND SMALLER ARE <br />FROM THE CONTRACT DRAWINGS ARE DEEMED NECESSARY BY THE <br />TO HAVE SOLDERED OR SCREWED CONNECTIONS. <br />CONTRACTOR, DETAILS OF SUCH DEPARTURES AND REASONS <br />THEREFORE SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL. <br />17. PIPING SYSTEM INSULATION: <br />POTABLE COLD WATER PIPING - ALL PIPING ABOVE CEILING OR <br />EXPOSED TO THE EXTERIOR WITH 1" THICK FIBERGLASS OR 1/2" <br />6 IT IS THE INTENT OF THE PLANS AND SPECIFICATIONS TO PROVIDE <br />FLEXIBLE UNICELLULAR. <br />A COMPLETE AND OPERATING INSTALLATION INCLUDING ALL <br />POTABLE HOT WATER. - ALL SUPPLY PIPING WITH 1" THICK <br />OBVIOUSLY NECESSARY ITEMS EVEN THOUGH SOME ITEMS MAY NOT <br />BE INDICATED ON THE DRAWING OR SPECIFICATIONS. <br />FIBERGLASS OR 1/2" THICK FLEXIBLE UNICELLULAR, EXCEPT THE <br />FIRST EIGHT LINEAL FEET OF HOT WATER SUPPLY PIPING SHALL BE <br />7. ALL OBVIOUS ERRORS AND/OR OMISSIONS IN THE ABOVE MENTIONED <br />MINIMUM OF 1" THICK INSULATION. <br />DOCUMENTS SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT / <br />SANITARY- ALL PIPING EXPOSED TO THE EXTERIOR WITH 2" THICK <br />ENGINEER PRIOR TO CONSTRUCTION. <br />FIBERGLASS OR 1" FLEXIBLE UNICELLULAR. <br />18. FIXTURES: <br />8. THIS CONTRACTOR SHALL INSPECT THE JOB SITE WHERE THE <br />A) PLUMBING FIXTURES SHALL BE FURNISHED AND <br />WORK IS TO BE PERFORMED AND SHALL AQUAINT THEMSELF WITH THE <br />CONDITIONS UNDER WHICH IT SHALL BE EXECUTED. <br />INSTALLED IN ACCORDANCE WITH THE SCHEDULE AS SHOWN ON <br />THE PLANS. ALL FIXTURES SHALL BE COMPLETE WITH HANGERS, <br />9. PROVIDE DIELECTRIC UNIONS OR FITTINGS WHENEVER FERROUS <br />CARRIERS, TRIM, STOP VALVES AND OTHER ACCESSORIES AS <br />AND NON-FERROUS PIPES ARE JOINED. <br />REQUIRED TO OBTAIN A COMPLETE INSTALLATION. <br />B) AMERICANS WITH DISABILITIES ACT (A.D.A.): ALL HANDICAP <br />FIXTURES AND TRIM SHALL COMPLY WITH FEDERAL AND STATE <br />10. PROVIDE ACCESS DOORS WHERE NECESSARY TO SERVICE SEALS, <br />ACCESSIBILITY CODES. NOTE: WATER CLOSET FLUSH VALVE <br />VALVES, TRAPS, CLEANOUTS, WATER HAMMER ARRESTORS, ETC. <br />CONTROLS SHALL BE MOUNTED ON THE WIDE SIDE OF TOILET <br />AREAS NO MORE THAN 44 INCHES ABOVE THE FLOOR. <br />11. CONTRACTOR TO VERIFY SIZE AND LOCATIONS OF ALL <br />EXISTING SERVICES PRIOR TO COMMENCING WITH NEW WORK. <br />19. ALL PIPING INSTALLED ON THE PROJECT SHALL BE <br />COORDINATE ALL CLEANOUTS WITH ARCHITECTURAL PRIOR TO <br />HYDRAULICALLY TESTED, FLUSHED AND DISINFECTED. <br />INSTALLATION. <br />20. .ALL PARTS, MATERIAL, EQUIPMENT AND LABOR FURNISHED <br />12. EVERY TRAP SHALL BE PROTECTED AGAINST SYPHONING AND <br />SHALL BEAR A ONE (1) YEAR, NO COST TO B.O.S., WARRANTY FROM <br />BACK PRESSURE. AIR CIRCULATION SHALL BE ASSURED BY MEANS <br />DATE OF FINAL ACCEPTANCE. THE PLUMBING CONTRACTOR SHALL <br />OF A SOIL OR WASTE STACK VENT, A CONTINUOUS SOIL OR WASTE <br />PROVIDE ALL OF THE ABOVE WARRANTY REQUIREMENTS IN A <br />VENT OR CIRCUIT VENT. <br />WRITTEN STATEMENT ALONG WITH EQUIPMENT MANUFACTURER'S <br />WARRANTIES. <br />13. ALL VENT PIPES PASSING THROUGH THE ROOF SHALL BE <br />FLASHED AS REQUIRED BY GENERAL CONTRACTOR. <br />20. VERIFY EXISTING LOCATIONS AND INVERTS OF PIPING. <br />VB O <br />O 3/4" COLD WATER SUPPLY <br />BALL VALVE (TYP) <br />AMTROL EXPANSION <br />6 <br />ABSORBER #AST-5 <br />3/4" <br />12 <br />O <br />13 <br />3/4" 3/4" <br />3/4" 3d 110 DEGREE F HOT WATER SUPPLY <br />7 <br />O REFER PLUMBING SCHEDULE (WH-1). <br />14 O 11 <br />32" <br />O2 PROVIDE HEAT TRAP (MIN. 12" OFFSET). <br />O 3/4" <br />-I I O T & P RELIEF VALVE. <br />7 <br />3/4" <br />PRESSURE TYPE VACUUM BREAKER. <br />O O® <br />7 <br />6 (D BALL & CHECK VALVE <br />©WATER HEATER WALL MOUNT PLATFORM <br />WITH INTEGRAL DRAIN PAN. <br />OHOLDRITE MODEL 40-SWHP-W. <br />9 <br />10 FACTORY ENGINEERED MOUNTING <br />7 HARWARE INCLUDED WITH ASSEMBLY. <br />O <br />G.C. SHALL PROVIDE BLOCKING AND STUDS <br />FOR SUPPORT AS REQUIRED BY MFR. <br />1" <br />(DDIELECTRIC UNION <br />MOUNT AS <br />O ROUTE AND OFFSET DRAIN LINE FULL SIZE <br />HIGH AS <br />AND AIR GAP 2" ABOVE MOP SINK BOTTOM. <br />POSSIBLE <br />10 ROUTE AND OFFSET T&P LINE FULL SIZE <br />NI AND AIR GAP 4" ABOVE MOP SINK BOTTOM. <br />11 MIXING VALVE - 80°F THRU 120°F <br />12 THERMOMETER. TRERICE #AO0507 W/ <br />#138-0015.2 WELL <br />MOP SINK 13 BALL VALVE <br />FINISH FLOOR 14 ELECTRICAL BY ELECTRICAL CONTRACTOR. <br />., a , <br />ELECTRICAL WATER HEATER DETAIL <br />NO SCALE <br />FINISHED FLOOR FLOOR DRAIN <br />FLASHING <br />r , <br />s L . <br />• a. <br />• IIIII <br />e <br />s." L <br />' e <br />• s <br />s a L s <br />TRAP PRIMER PIPING <br />UNION <br />TRAP PRIMER CONNECTION DETAIL <br />NOT TO SCALE <br />ENSURE NO OFFSETS <br />L: <br />OR SLOPE MORE <br />THAN 2%. <br />Twh <br />L '. <br />TAILPIECE <br />OD TUBING <br />SLIP JOINT <br />CHROME <br />WALLCOVEF <br />AND SCREN, <br />"WCO" <br />WALL CLEANOUT DETAIL <br />NOT TO SCALE <br />"P"TRAP DETAIL <br />NOT TO SCALE <br />PLUMBING FIXTURE UNIT SCHEDULE <br />QUANTITY <br />DESCRIPTION <br />WATER <br />DEMAND <br />SANITARY <br />FIXTURE UNIT (F.U.) (EACH) <br />FIXTURE <br />UNITS (TOTAL) <br />FIXTURE UNIT (F.U.) <br />COLD <br />HOT <br />COMB. <br />COLD <br />HOT <br />COMB. <br />F.U. (EACH) <br />F.U. (TOTAL) <br />1 <br />DRINKING FOUNTAIN <br />0.25 <br />0 <br />0.25 <br />0.25 <br />0.00 <br />0.25 <br />1.50 <br />1.50 <br />2 <br />FLOOR DRAINS <br />0 <br />0 <br />0 <br />0.00 <br />0.00 <br />0.00 <br />2.00 <br />4.00 <br />2 <br />LAVATORY (PUBLIC) <br />1.50 <br />1.50 <br />2.00 <br />3.00 <br />3.00 <br />4.00 <br />2.00 <br />4.00 <br />1 <br />SERVICE SINK <br />2.25 <br />2.25 <br />3.00 <br />2.25 <br />2.25 <br />3.00 <br />2.00 <br />2.00 <br />2 <br />WATER CLOSET, PUBLIC FLUSH TANK <br />5 <br />0 <br />5 <br />10.00 <br />0.00 <br />10.00 <br />4.00 <br />8.00 <br />1 <br />KITCHEN SINK <br />1.00 <br />1.00 <br />1.40 <br />1.00 <br />1.00 <br />1.40 <br />2.00 <br />2.00 <br />0 <br />URINAL <br />5.00 <br />0 <br />5.00 <br />0.00 <br />0.00 <br />0.00 <br />2.00 <br />0.00 <br />9 <br />TOTAL: <br />1&50 <br />6.2,'i <br />1&65 <br />- <br />21.50 <br />NOTES: <br />1) SYSTEM WILL REQUIRE 1" WATER MAIN. 1" EXISTING. <br />2) SYSTEM WILL REQUIRE A MINIMUM 3" BUILDING DRAIN (1/8" SLOPE). 4" INSTALLED.. <br />B.O.S. PLUMBING FIXTURE SCHEDULE <br />MARK <br />DESCRIPTION <br />FIXTURE MFG. <br />CATALOG NO. <br />TRIM MFG. <br />CATALOG NO. <br />REMARKS <br />NOTE <br />CONNECTION <br />SIZES <br />W <br />V <br />C <br />H <br />WC-1 HL <br />WATER CLOSET-ADA-LEFT SIDE FLUSH VALVE <br />AMER. STD. <br />3043.001 <br />SLOAN <br />111-YBYC-YO <br />OLSONITE SEAT #95-SS, 3/8" BRASS BOLTS <br />3 <br />3" <br />2" <br />1" <br />- - <br />WCA HR <br />WATER CLOSET-ADA-RIGHT SIDE FLUSH VALVE <br />AMER. STD. <br />3043.001 <br />SLOAN <br />111-YBYC-YO <br />OLSONITE SEAT #95-SS, 3/8" BRASS BOLTS <br />3 <br />3" <br />2" <br />1" <br />- - <br />L-1 H <br />LAVATORY - WHITE - WALL HUNG - HANDICAP <br />AMER. STD. <br />0355.012 <br />SYMMONS <br />S-20-2-G-FR-VP <br />Z-1231-79 CARRIER <br />1-2-3-5 <br />2" <br />2" <br />1/2" <br />1/2" <br />EWC-H <br />ELECTRIC WATER COOLER - HANDICAP <br />ELKAY <br />EZSTL-8-C <br />ELKAY <br />LKAPR-EZL <br />ADA APRON <br />1-2-3 <br />2" <br />2" <br />1/2" <br />- <br />MS <br />FLOOR MOP SINK 24"X24"X10" <br />MUSTEE <br />63M <br />MUSTEE <br />63.600A <br />63CM KIT -SINK, FAUCET, HOSE, MOP HANGAR, STRAINER, PIPE SEAL <br />1-2-6 <br />3" <br />2" <br />1/2" <br />1/2" <br />CS <br />COUNTER SINK, 5 1/2" DEEP MOUNT IN COUNTER SURFACE <br />ELKAY <br />LRAD1918553 <br />AMER. STND. <br />6409.170.002 <br />PROVIDE DRAIN STRAINER, RECESS MOUNT, 3-HOLE 4" O.C. <br />1-2 <br />2" <br />2" <br />1/2" <br />1/2" <br />RW <br />REFRIGERATOR WATER CONNECTION -HAMMER VALVE <br />OATEY <br />39152 (1 ONLY) <br />MAKE CONNECTION TO OWNER PROVIDED REFRIGERATOR <br />- - <br />- - <br />1/2" <br />- - <br />BV <br />BALL VALVE <br />APOLLO <br />70-200 <br />AS REQUIRED BY PLAN. <br />- - <br />- <br />- - <br />- - <br />WCO <br />WALL CLEANOUT <br />ZURN <br />Z1446 <br />PVC PLUG WITH BRONZE INSERT W/THREADS TO MATCH COVER <br />- - <br />- - <br />- - <br />- - <br />FD <br />FLOOR DRAIN <br />ZURN <br />ZS415NL-VP-P <br />INSTALL FLUSH WITH FINISHED FLOOR. CONNECT TO TRAP PRIMER (TP) <br />3" <br />- - <br />TP <br />TRAP PRIMER <br />PPP <br />P-1 <br />-- <br />- <br />1/2" <br />-- <br />VB <br />VACUUM BREAKER - PRESSURE TYPE <br />WATTS <br />N36 <br />LOCATE & SIZE AS PER MFG. INSTRUCTIONS <br />WHA <br />WATER HEATER - ELECTRIC - 20 GAL. - 2KW NON-SIM. <br />RHEEM <br />EGSP20 <br />SEE DETAIL. (208V) <br />- - <br />- - <br />- - <br />PLUMBING NOTES: GENERAL NOTES: <br />(1) MCGUIRE CAST BRASS P-TRAP WITH TUBULAR WALL BEND (SIZE AS REQUIRED). P-TRAPS IN CONCEALED (A) ALL PLUMBING FIXTURES SHALL BE WHITE. <br />SPACES MAY BE PVC. (B) PROVIDE ONLY PRIOR APPROVED MANUFACTURERS. <br />(2) MC GUIRE LAWSINK SUPPLY STOP #H2165CCLK WITH CHROME RISER TUBE. (C) SEE ARCHITECTURAL DRAWINGS FOR TOILET ACCESSORIES (SOAP DISPENSERS, DRYERS, ETC. AND ELEVATIONS. <br />(3) SET AT HANDICAP HEIGHT. (D) VERIFY PIPE SIZES FOR "BV", "FD", "ECO", "WCO" OR OTHER COMPONENTS. <br />(4) REQUIRED IN MEN'S AND WOMEN'S TOILET ROOM UNDER LAVATORY. (E) KOHLER MAY BESUBSTITUTED FOR AMERICAN STANDARD PLUMBING FIXTURES. <br />(F) BENEKE MAY BE SUBSTITUTED FOR OLSONITE SEATS. <br />(5) TRUEBRO LAV GUARD: MODEL NO. 102W FOR P-TRAP AND ANGLE STOPS WITH SUPPLY ASSEMBLIES. (G) BRASSCRAFT MAY BE SUBSTITUTED FOR MCGUIRE. <br />MODEL NO. 102W WITH 105 ACCESSORY FOR OFFSET DRAIN. <br />(6) PROVIDE THE MUSTE 63CM KIT THAT PROVIDES THE MOP SINK(63M), FAUCET / FAUCET HANGER(63.600A), HOSE AND <br />HOSE HOLDER BRACKET(65.700), DRAIN SEAL(65.309), STRAINER(INCL.W/ SINK), AND MOP HOLDER BRACKET(65.600). <br />KIT AVAILABLE AT GRAINGER, GRAINGER #11 U264. <br />1 ' 2 3 ' 4 1 5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />MAY EXTEND AS A <br />WASTE OR VENT <br />WALL <br />PLUGGED TEE <br />WITH CLEANOUT <br />FLOOR LINE <br />1/8" C.I. BEND <br />_ BALANCE OF PIPING SAME <br />AS CLEANOUT OT GRADE <br />IE <br />F <br />TREADS <br />CONNECT TO TEES <br />AS REQUIRED <br />12 <br />2 V /Ole <br />^\ <br />/// 1 \ 2"V <br />\ REUSE EXISTING <br />r 1 \� ROOF PENETRATION <br />i \ 3" VTR <br />\ \ 3 V <br />I I I \\ <br />I I \ I <br />CONNECT TO EXISTING SITE I 2"V 1 \ <br />SANITARY. FIELD VERIFY I I \\ 1 <br />EXACT LOCATION, INVERT I 4 I 12"V \ v \ I \ \ <br />AND FLOW DIRECTION. 1 \ 3"V <br />I 1 \ 1 100, \\ <br />z"v 1 i I \\\ le� 001 \ <br />I <br />I <br />EWC-H 2„ <br />MS1 <br />2" <br />3" <br />13 <br />14 <br />15 <br />IR <br />WCO <br />16 <br />D <br />3" <br />SANITARY RISER <br />NOT TO SCALE <br />ME3 <br />CONSULTING ENGINEERS, LLC <br />5300 Paylor Lane <br />Sarasota, FL 34240 <br />Tel:941-748-1319 Fax:941-361-1221 <br />www.me3-engr.com sidney@me3-engr.com <br />Designed: BAK ME3 Job No: B17-1166 <br />Checked: BAK Date: 09/29/2017 <br />Drawn: KCC C.O.A.27552 <br />Copyright 2017 ME3 All rights reserved <br />P <br />IN <br />N <br />M <br />L <br />K <br />J <br />H <br />G <br />F <br />REV. DESCRIPTION DATE <br />BID & PERMIT SET E <br />09.29.17 <br />CURRENT ISSUE STATUS: <br />"To the best of the Architect's or <br />Engineer's knowledge, the plans <br />and specifications comply with the <br />applicable minimum building codes <br />and applicable fire safety standards <br />as determined by local authority in <br />accordance with Chapter 553 and <br />663 of Florida Statutes." <br />(17 <br />Kay C. Clem <br />Florida License # 53270 <br />WBRCIENI. <br />ARCHITECTS ENGINEERS <br />8130 Lakewood Main Street Phone: 941-556-0757 <br />Suite 210 Fax: 941-556-0759 <br />Lakewood Ranch, FL 34202 www.wbrcae.com <br />Firm Lic. # AA26001395 & 27389 Douglas W.Whitney AIA <br />BEALLS OUTLET #542 <br />ZEPHYRHILLS <br />PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 B <br />SHEET TITLE: <br />WBRC CAD FILE: <br />PROJECT No. 3542XX GRAPHIC SCALE: <br />0„ <br />SCALE: As Indicated I I A <br />PLUMBING PLAN PROJECT MANAGER <br />SHEET No. <br />1 /4" _ 1 i_Off N DRAWN BY: P 101 <br />CHECKED BY: <br />17 18 19 20 <br />PLUMBING PLAN <br />