Q <br />1 1 2 1 3 1 4 1 5 I 6 1 7 I 8 1 9 1 10 1 11 1 12 1 13 1 14 <br />15 1 16 1 17 <br />18 1 19 1 20 <br />C <br />P <br />0 <br />N <br />M <br />L <br />K <br />J <br />H <br />G <br />F <br />E <br />9 <br />C <br />B <br />A <br />NOTES: <br />1. THESE DUCT FITTINGS SHALL BE <br />USED UNLESS OTHERWISE NOTED. <br />45 DEG <br />MAX. <br />OO <br />30 DEG <br />CONCENTRIC TRANSITION <br />MAX. <br />ECCENTRIC TRANSITION <br />ASHRAE #3-5 <br />RADIUS W <br />R <br />ASHRAE #3-6 <br />MITERED <br />1000 FPM <br />MAX <br />ASHRAE #3-1 <br />RADIUS D <br />a <br />ASHRAE #6-33 <br />SYMETRICAL WYE <br />VOL <br />DAMPER <br />R = 3W/2 <br />RECTANGULAR ELBOWS <br />RECTANGULAR ELBOWS <br />R = 3D/2 <br />ROUND ELBOWS <br />SPUTTER DUCT <br />ASHRAE #6-29 <br />TEE WITH 45 DEG ENTRY <br />ASHRAE #6-27 <br />CONICAL TEE <br />ASHRAE #6-10 <br />90 DEG CONICAL TEE <br />ASHRAE #6-11 <br />45 DEG CONICAL WYE <br />RECTANGULAR TRUNK <br />RECTANGULAR TAP <br />RECTANGULAR TRUNK <br />ROUND TAP <br />ROUND TRUNK <br />ROUND TAP <br />ROUND TRUNK <br />ROUND TAP <br />ACCEPTABLE DUCT FITTINGS <br />MECHANICAL PROJECT NOTES <br />1. THE CONTRACTOR SHALL ARRANGE AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED IN THIS WORK. <br />2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, SPECIFICATIONS, LOCAL, STATE AND NATIONAL CODES. CERTIFICATES OF INSPECTION, WHERE REQUIRED, <br />SHALL BE OBTAINED AND PAID FOR BY THIS CONTRACTOR AND FURNISHED TO THE TENANT. <br />3. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM MECHANICAL WORK AS SHOWN, NOTED OR SCHEDULED FOR A COMPLETE <br />INSTALLATION. <br />4. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND COMMERCIAL GRADE. <br />5. THE CONTRACT DRAWINGS INDICATE THE EXTENT AND GENERAL ARRANGEMENTS OF EQUIPMENT AND SYSTEMS. IF ANY DEPARTURES FROM THE CONTRACT DRAWINGS ARE <br />DEEMED NECESSARY BY THE CONTRACTOR, DETAILS OF SUCH DEPARTURES AND REASONS THEREFORE SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL. <br />6. IT IS THE INTENT OF THE PLANS AND SPECIFICATIONS TO PROVIDE A COMPLETE AND OPERATING INSTALLATION INCLUDING ALL OBVIOUSLY NECESSARY ITEMS EVEN THOUGH <br />SOME ITEMS MAY NOT BE INDICATED ON THE DRAWING OR SPECIFICATIONS. <br />7. ALL OBVIOUS ERRORS AND/OR OMISSIONS IN THE ABOVE MENTIONED DOCUMENTS SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT / ENGINEER PRIOR TO <br />CONSTRUCTION. <br />8. THIS CONTRACTOR SHALL INSPECT THE JOB SITE WHERE THE WORK IS TO BE PERFORMED AND SHALL AQUAINT THEMSELF WITH THE CONDITIONS UNDER WHICH IT SHALL BE <br />EXECUTED, REVIEW EXISTING SYSTEMS FOR CAPACITY AND AREA SERVED. NOTIFY ENGINEER IF DISCREPENCIES ARE FOUND OR IN CONFLICT WITH NEW PLAN. <br />9. ROOFTOP UNITS ARE EXISTING. REPLACE ALL FILTERS. <br />10. DUCT DIMENSIONS SHOWN ON THE DRAWINGS ARE CLEAR INSIDE "FREE AREA" DIMENSIONS. <br />11. PROVIDE CONICAL SPIN -IN OR PRESSURE FITTINGS WITH VOLUME DAMPER AT ALL FLEXIBLE DUCT RUNOUTS TO DIFFUSERS. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE T-0". <br />12. METAL DUCTS WHICH PENETRATE RATED FIRE WALLS AND ARE LESS THAN 100 SQ. INCHES SHALL EXTEND A MINIMUM OF 5 FEET ON BOTH SIDES OF THE WALL WITHOUT AN <br />OPENING (TO PRECLUDE THE REQUIREMENT OF A FIRE DAMPER). DUCTWORK SHALL IN NO CASE BE LIGHTER THAN 24 GAUGE STEEL. PENETRATIONS GREATER THAN 100 SQ. <br />INCHES SHALL REQUIRED A FIRE DAMPER. <br />13. PROVIDE IDENTIFICATION OF THE LOCATION OF ALL FIRE AND BALANCING DAMPERS. IDENTIFICATION TAGS SHALL BE AFFIXED TO THE WALLS OR CEILINGS AND SHALL BE <br />VISIBLE FROM THE OCCUPIED SPACE. <br />14. INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS AND RECOMMENDATIONS. <br />15. ALL INSULATION SHALL BE FIRE RATED IN ACCORDANCE WITH ASHRAE 90A 50/25 SMOKE DEVELOPMENT AND FLAME SPREAD REQUIREMENTS. INSULATION "R" VALUES SHALL <br />COMPLY WITH ENERGY CODES. <br />16. MOUNT THERMOSTATS WHERE INDICATED ON PLANS, AT 60" CL. A.F.F. NEW THERMOSTATS SUPPLIED BY B.O.S., INSTALLED BY CONTRACTOR. INSTALL NEW CABLE TO <br />ASSOCIATED RTU. PROGRAM NEW THERMOSTAT'S AS INDICATED. <br />17. DUCTWORK IS TO BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH SMACNA MANUALS TO 2" PRESSURE CLASS FOR SUPPLY UPSTREAM OF TERMINAL UNITS, 1" PRESSURE <br />CLASS FOR DOWNSTREAM OF TERMINAL UNITS AND 1" NEGATIVE PRESSURE CLASS FOR RETURN, SEAL CLASS "A" AND THE FOLLOWING SCHEDULE: <br />A) RECTANGULAR DUCTS - GALVANIZED SHEET METAL WITH A MINIMUM 2" THICK, 1# DENSITY EXTERNAL DUCT WRAP. <br />B) RIGID ROUND DUCTS - GALVANIZED SHEET METAL WITH A MINIMUM 2" THICK, 1# DENSITY EXTERNAL INSULATION. <br />C) FLEXIBLE ROUND DUCTS -FLEXIBLE, WIRE REINFORCED DUCT WITH EXTERNAL INSULATION WITH VAPOR BARRIER AND FOIL FACED. MAXIMUM FLEXIBLE DUCT LENGTH <br />TO BE T-0". <br />D) EXHAUST AND OUTSIDE AIR DUCT - GALVANIZED SHEET METAL, NON -INSULATED. <br />E) DUCT WRAP INSULATION - NOTED ABOVE MUST COMPLY WITH ENERGY EFFICIENCY CODES. THE INSULATION MUST HAVE A MINIMUM INSTALLED R = 6.0. <br />18. PORTIONS OF DUCTWORK VISIBLE THROUGH GRILLS, REGISTERS, AND DIFFUSERS IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. <br />19. UNLESS OTHERWISE NOTED, INSTALL ALL DUCTWORK AS HIGH AS POSSIBLE, TIGHT TO THE BOTTOM OF THE STRUCTURE. COORDINATE ELEVATION AND LOCATION WITH RAIN <br />LEADERS, WATER PIPING, PLUMBING VENTS, AND MAJOR ELECTRICAL CONDUITS OR CABLE TRAY. <br />20. PROVIDE BALANCING DAMPER IN EACH BRANCH CONNECTION. <br />1 ' 2 ' 3 ' 4 ' 5 ' 6 ' 7 18 9 ' 10 <br />1/4" DIA. STEEL <br />unnin�n rr�no <br />METAL DUCT <br />STRAPR <br />60" MAX <br />UNLESS FLOOR STRAP <br />IS PLACED UNDER <br />A BOTTOM <br />REINFORCEMENT. <br />1" <br />SCREWS SCREWS MAY BE <br />OMITTED IF HANGER LOOPS <br />SECURE WIRE <br />LOAD RATED <br />FASTENERS <br />6 <br />10" DIA. MAX 24" DIA. MAX <br />DUCT HANGARS <br />NO SCALE <br />OPEN ULILINU <br />MOUNTING SIMILAR <br />ICEILING EXHAUST FAN DETAIL I <br />NO SCALE <br />SPIN —IN FITTING WITH SUPPORT WIRE TO <br />BUTTERFLY DAMPER & PREVENT SAGS & <br />45 DEG. EXTRACTOR KINKS IN FLEX <br />—SUPPORT AS <br />PER SMACNA <br />STANDARDS —][ROUND "SNAPLOCK" SHEET METAL FOR RUNOUTS <br />GREATER THAN 5FT., WITH WRAP INSULATION. <br />AN APPROVED ALTERNATE IS "SPIRO—PIPE", / <br />ESPECIALLY FOR LONG RUNS. <br />2" WRAP INSULATION: <br />SUPPLY DUCT CUT, FIT & GLUED OVER <br />CEILING DIFFUSER —\ <br />WRAP INSULATION <br />FLEXIBLE DUCT- DO NOT <br />SAG OR KINK, INSULATED, <br />MAXIMUM 5 FT. LONG <br />THREE SHEET METAL <br />/ <br />SCREWS THELIX <br />OF FLEXIBLE DUCT, <br />� <br />BAND CLAMP &TAPED <br />CEILING ­'/ CEILING DIFFUSER) <br />NOTES: <br />1. DIFFUSER —TRANSITION ASSEMBLY TO <br />BE SUPPORTED FROM STRUCTURE <br />ABOVE. <br />2. THERE SHALL BE NO INSULATION <br />EXPOSED TO THE AIRSTREAM. <br />CEILING DIFFUSER RUNOUT DETAIL <br />NO SCALE <br />SQUARE DIFFUSER NECK MUST BE CONNECTED <br />TO HARD DUCT OR TO FLEXDUCT BY MEANS <br />OF A MINIMUM 12" DEEP SQUARE -TO -ROUND <br />NECK TRANSITION <br />ROUND DIFFUSER NECK TO BE CONNECTED <br />TO HARD DUCT OR TO FLEXDUCT <br />CEILING DIFFUSER <br />CD-9x9 - DIFFUSER NECK SIZE <br />290 C�FM <br />DESIRED AIR QUANITY <br />�— <br />MANUFACTURER: METAL*AIRE <br />MODEL: 5000 <br />MANUFACTURER: TITUS <br />MODEL: TDC-AA <br />ARROWS INDICATE BLOW PATTERN <br />CONNECTING i <br />INSULATE <br />INSULATED <br />SQUARE TO <br />FLEX DUCT <br />/ <br />ROUND <br />TRANSITION WITH <br />/ <br />NOTE: <br />2" THICK, 1# <br />DIFFUSER ASSEMBLY / / <br />DENSITY <br />TO BE SUPPORTED / <br />EXTERNAL DUCT <br />FROM STRUCTURE <br />WRAP. <br />ABOVE. / <br />INSULATE BACK OF <br />DIFFUSER WITH 2" <br />THICK, 1# DENSITY <br />EXTERNAL DUCT <br />WRAP. <br />/ <br />NOTE: <br />THERE SHALL BE NO INSULATION SUPPLY SUSPENDEErf <br />EXPOSED TO THE AIRSTREAM. DIFFUSER CEILING TEE <br />LAY -IN SUPPLY DIFFUSER DETAIL <br />NO SCALE <br />MANUFACTURER: METAL*AIRE <br />MODEL:CC5 <br />MANUFACTURER: TITUS <br />MODEL: 50F <br />RETURN GRILLE <br />RG-22x22 — GRILLE NECK SIZE <br />1000 CFM <br />DESIRED AIR QUANITY <br />ARROW INDICATE DIRECTION <br />OF AIR FLOW <br />CONNECTING <br />INSULATED <br />FLEX DUC <br />INSULATE <br />/ INSULATED <br />OUTSIDE OF <br />DIFFUSER <br />DIFFUSER BOX <br />/ / <br />BOX <br />WITH WRAPPED <br />INSULATION. <br />TRANSFER / <br />INSIDE OF BOX TO / <br />GRILLES <br />BE PAINTED BLACK <br />SIMILAR / <br />/ 12" MIN <br />/EGGCRATE <br />SUSPENDED CEILING TEE J <br />GRILLE <br />LAY -IN TILE <br />NOTE: <br />THERE SHALL BE NO <br />INSULATION EXPOSED <br />TO THE AIRSTREAM. <br />LAY -IN RETURN GRILLE DETAIL <br />NO SCALE <br />MECHANICAL LEGEND AND NOTES <br />RTU IN EXPANDED AREA ARE EXISTING NEW. <br />NEW RTU IS SUPPLIED BY BEALLS OUTLET, INSTALLED AND CONNECTED BY CONTRACTOR. <br />ALL RTU'S AND SPLIT SYSTEM IN EXISTING STORE ARE EXISTING. <br />ALL DUCTWORK IN EXPANDED ARE IS NEW. NEW DUCTWORK SHALL BE METAL OR FLEX WITH R-6 <br />INSULATION. INSTALLATION AND MATERIAL SHALL COMPLY WITH ALL ENERGY REQUIREMENTS. <br />ALL DUCTWORK AND GRILLES IN EXISTING STORE ARE EXISTING. RELOCATE GRILLES INDICATED. <br />INSTALL NEW THERMOSTAT WHERE SHOWN AND CONNECT TO RTU'S. <br />THERMOSTAT SUPPLIED BY B.O.S., INSTALLED AND WIRED BY CONTRACTOR. <br />PROGRAM THERMOSTATS AS SCHEDULED. <br />TRUNK DUCTS MAY BE THE EQUIVALENT RECTANGULAR SIZE. <br />DUCT SMOKE DETECTORS AND TEST / RESET DEVICES ARE SHOWN ON THE FIRE <br />ALARM DRAWINGS. SEE FIRE ALARM DRAWINGS FOR REQUIREMENTS AND <br />INSTALLATION. DEVICES ARE SUPPLIED AND INSTALLED BY FIRE ALARM <br />CONTRACTOR. <br />THERMOSTAT. <br />UNIT CONTROLLED AS INDICATED. <br />INSTALL AT 48" AFF <br />F.D. FIRE DAMPER - SEE DETAIL CD CEILING DIFFUSER <br />LV SR SIDEWALL REGISTER <br />LOUVER CR CEILING REGISTER <br />DUCT UP RG RETURN GRILLE <br />DUCT DOWN DRG DUCT I RETURN GRILLE <br />SRG SIDEWALL RETURN GRILLE <br />VOLUME DAMPER DR DUCT MOUNTED REGISTER <br />TRANSITION EG EXHAUST GRILLE <br />AFF ABOVE FINISHED FLOOR <br />MECHANICAL DETAILS <br />Q NO SCALE <br />11 112 1 13 14 1 15 16 17 1 18 <br />11 <br />-NTIA 1 *1 <br />CONSULTING ENGINEERS, LLC <br />5300 Paylor Lane <br />Sarasota, FL 34240 <br />TI 941-748-1319 Fax: 941-361-1221 <br />www.me3-engr.com sidney@me3-engr.com <br />Designed: BAK ME3 Job No: B17-1166 <br />Checked: BAK Date: 09/29/2017 <br />Drawn: KCC C.O.A.27552 <br />Copyright 2017 ME3 All rights reserved <br />P <br />9 <br />N <br />M <br />L <br />K <br />J <br />H <br />G <br />F <br />REV. I DESCRIPTION I DATE <br />BID & PERMIT SET E <br />09.29.17 <br />CURRENT ISSUE STATUS: <br />"To the best of the Architect's or <br />Engineer's knowledge, the plans <br />and specifications comply with the <br />applicable minimum building codes <br />and applicable fire safety standards <br />as determined by local authority in <br />accordance with Chapter 553 and <br />663 of Florida Statutes." <br />9--CaL- D <br />to/q f I � <br />Kay C. Clem <br />Florida License # 53270 <br />WBR(IIIIIIIIIIIIIIINoI <br />ARCHITECTS ENGINEERS <br />8130 Lakewood Main Street Phone: 941-556-0757 <br />Suite 210 Fax: 941-556-0759 <br />Lakewood Ranch, FL 34202 www.wbrcae.com <br />Firm Lic. # AA26001395 & 27389 Douglas W.Whitney AIA <br />BEALLS OUTLET #542 <br />ZEPHYRH I LLS <br />PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 B <br />MECHANICAL DETAILS <br />SHEET TITLE <br />WBRC CAD FILE <br />PROJECT No. 3542XX GRAPHIC SCALE: <br />0„ ill <br />SCALE: As Indicated 6mmmmil A <br />PROJECT MANAGER: <br />SHEET No. <br />DRAWN BY: M 1 02 <br />CHECKED BY: <br />19 20 <br />