Laserfiche WebLink
A !w� 0 I I 'I'i-II !I +I 'll I I' rnl "If! 1 rpL in?i,I I <br />SHEET NOTES: <br />1. HALF SHADED OR FULLY SHADED LUMINAIRES SHALL BE <br />PROVIDED WITH SELF-CONTAINED 90-MINUTE BACK-UP <br />BATTERY PACKS. <br />2. EMERGENCY LIGHTING FIXTURES SHALL SWITCH WITH <br />LOCAL NORMAL LIGHTING UNLESS INDICATED AS "EM/NL" OR <br />"NL" (NIGHT LIGHT). <br />3. EMERGENCY FIXTURES WITH INTEGRAL 90-MINUTE BATTERY <br />PACKS SHALL BE PROVIDED WITH AN UN -SWITCHED HOT <br />CONDUCTOR SO THAT EMERGENCY BATTERY PACK CAN <br />CHARGE WHEN POWER TO THE LIGHT FIXTURES IS <br />SWITCHED OFF. <br />4. EXIT AND NIGHT LIGHT FIXTURES SHALL BE CONNECTED TO <br />UN -SWITCHED CIRCUIT AHEAD OF LIGHTING CONTROLLER. <br />5. THE CIRCUIT NEUTRAL CONDUCTOR SHALL BE ROUTED TO <br />EACH LINE VOLTAGE WALL SWITCH. WHERE THE WIRING <br />DEVICE DOES NOT REQUIRE THE USE OF A NEUTRAL <br />CONDUCTOR, CAP FOR FUTURE USE. <br />CEILING SOFFIT. <br />ELECTRICAL PROPOSED CEILING PLAN <br />SCALE <br />3/16" = V-0" <br />LUMINAIRE SCHEDULE <br />LIGHT FIXTURE <br />MARK <br />DESCRIPTION <br />MOUNTING <br />LAMPS <br />VOLTS <br />WATTS <br />MFG. <br />MODEL # <br />TYPE <br />2X4 LED TROFFER WITH GLOSS FINISH, 4000 <br />A <br />LUMENS, 120V, 4000K <br />CREE <br />ZR24T-40L-40K-120 <br />RECESSED <br />LED <br />120 <br />40 <br />2X4 LED TROFFER WITH GLOSS FINISH, 4000 <br />AE <br />LUMENS, 120V, 4000K WITH 1400 LUMEN <br />CREE <br />ZR24T-40L-40K-120-EB14 <br />RECESSED <br />LED <br />120 <br />40 <br />EMERGENCY BATTERY. <br />B <br />IMMERSION ELITE REFRIGERATED DISPLAY CASES <br />GE LIGHTING <br />60" 5000CCT ELITE PREMIUM <br />SURFACE <br />LED <br />24VDC <br />24/DOOR <br />D <br />48" LED WRAP, ARC LENS, 4000 LUMENS, 120V, <br />CREE <br />S-WR-4-40L-40K-120 <br />SURFACE <br />LED <br />120 <br />36 <br />4000K <br />DE <br />48" LED WRAP, ARC LENS, 4000 LUMENS, 120V, <br />CREE <br />S-WR-4-40L-40K-120-EB <br />SURFACE <br />LED <br />120 <br />33 <br />4000K WITH 1100 LUMEN EMERGENCY PACK. <br />4' LED WET LOCATION LINEAR LUMINAIRE, 120V, <br />E <br />4700 LUMENS, 4000K <br />CREE <br />WS4-47L-40K-120-FD <br />SURFACE <br />LED <br />120 <br />50 <br />EM <br />WET LOCATION 2 HEAD EMERGENCY LIGHTING <br />LITHONIA <br />WLTU GY MR <br />SURFACE <br />HALOGEN <br />120 <br />- <br />UNIT. <br />X <br />2 REMOTE HEAD COMBO EXIT LIGHT <br />LIGHTALARMS <br />UQLXN500R-2LEDR/ELF652D <br />SURFACE <br />LED <br />120 <br />3.56 <br />KEYED NOTES: <br />O SALES FLOOR LIGHTING: CONNECT NEW LED LIGHT FIXTURES TO EXISTING <br />BRANCH CIRCUIT. EC TO VERIFY EXISTING BRANCH CIRCUIT HAS ADEQUATE <br />CAPACITY. <br />ORESTROOM EXHAUST FAN: EXHAUST FAN SHALL BE WIRED TO OPERATE <br />WHEN LIGHTS ARE 'ON'. CONNECT EXHAUST FAN AND LOCAL RESTROOM <br />LIGHTS TO EXISTING LIGHTING CIRCUIT SERVING THIS SPACE. <br />O ANTHONY DOOR LIGHTS: NEW ANTHONY DOOR LIGHTS PER MANUFACTURER <br />INSTALLATION INSTRUCTIONS CONNECTED TO CIRCUIT MADE SPARE DURING <br />DEMOLITION. REFER TO LUMINAIRE SCHEDULE FOR MORE INFORMATION. <br />O SALES AREA LIGHTING CONTROL: LIGHT SWITCH LOCATIONS ARE PROPOSED <br />ONLY. EXACT LOCATION OF LIGHT SWITCHES SHALL BE DETERMINE IN FIELD <br />BY ARCHITECT AND OWNER FIELD REPRESENTATIVE. <br />ONEW CEILING MOUNTED RECEPTACLE: PROVIDE CEILING MOUNTED <br />RECEPTACLE AND TIE TO CIRCUIT AS SHOWN ON PLAN WITH 2 #12 AND 1 #12 <br />EG IN 3!4" CONDUIT. <br />OLOW TEMPERATURE OCCUPANCY SENSOR: PROVIDE WATTSTOPPER CB-100 <br />OR EQUAL. <br />O WALL MOUNTED OCCUPANCY SENSOR: PROVIDE WATTSTOPPER DW-100 OR <br />EQUAL. <br />0 POWER PACK FOR LIGHTING CONTROL: PROVIDE WATTSTOPPER BZ-250 OR <br />EQUAL. <br />NEW WORK LEGEND: <br />REFER TO PROPOSED PLANS FOR ADDITIONAL NOTES AND REQUIREMENTS. ALL <br />DEVICES, FIXTURES, AND EQUIPMENT SHOWN ON THE PROPOSED ELECTRICAL <br />PLAN IS NEW UNLESS NOTED OTHERWISE WITH THE BELOW DESIGNATIONS. <br />(e) SUBSCRIPT DENOTES EXISTING TO REMAIN. MAINTAIN SERVICE VIA <br />EXISTING CIRCUIT. <br />(n) SUBSCRIPT DENOTES NEW. <br />(r) SUBSCRIPT DENOTES EXISTING TO BE RELOCATED. MATCH EXISTING <br />WIRING AND CONDUIT AND EXTEND TO PROPOSED LOCATION. WIRING <br />DEVICES SHALL BE PROVIDED WITH NEW DEVICES AND COVER PLATES <br />TO MATCH NEW WORK. LIGHT FIXTURES SHALL BE CLEANED AND <br />RE-LAMPED. <br />(er) SUBSCRIPT DENOTES EXISTING DEVICE/FIXTURE TO BE REPLACED IN <br />SAME LOCATION AS EXISTING. RECONNECT NEW DEVICE/FIXTURE TO <br />EXISTING CIRCUIT. WIRING DEVICES SHALL BE REPLACED WITH NEW <br />DEVICES AND COVER PLATES TO MATCH NEW WORK. LIGHT FIXTURES <br />SHALL BE REPLACED WITH NEW FIXTURES PER LIGHTING FIXTURE <br />SCHEDULE. <br />DARK LINES INDICATE NEW, EXISTING TO BE RELOCATED, OR EXISTING <br />TO BE REPLACED. <br />LIGHT LINES INDICATE EXISTING TO REMAIN. <br />CD <br />M <br />0 <br />0 <br />� <br />0 <br />m <br />w <br />) <br />a <br />y <br />0 <br />.0 <br />U. <br />N <br />U <br />z° <br />INFINITY ENGINEERING <br />GROUP, LLC <br />1208 East Kennedy Boulevard <br />Suite 230 <br />Tampa, Florida 33602 <br />[p]: 813.434.4770 <br />[f]: 813.445.4211 <br />www.iegroup.net <br />Cert. of Auth. No. 27889 <br />Client Name and Address <br />1201 OAKFIELD DRIVE, NO. 109 <br />BRANDON, FLORIDA 33509 <br />=s�:f5!.968 <br />AN T fCj E. <br />TV <br />m I7; <br />-n - <br />E OF <br />Z <br />Q <br />J <br />N <br />tLO <br />C7 <br />M <br />rn <br />V <br />L 7 <br />i <br />J <br />J <br />0 <br />J <br />a✓ <br />a <br />0 <br />W <br />cc � <br />w N <br />O <br />V <br />> <br />J <br />m <br />IZ <br />O <br />J <br />J <br />Q <br />y <br />L <br />NLO <br />J <br />Q <br />`D <br />0 <br />ca <br />z <br />U <br />W <br />IL <br />cn W <br />Project No. <br />Sheet <br />140-88.00 <br />E-202 <br />Date <br />05/03/2019 <br />Scale <br />AS NOTED <br />