ELECTRICAL CHASE <br />UP TO CEILING. <br />ELECTRICAL PROPOSED FLOOR PLAN <br />KEYED NOTES: <br />1O NEW IG RECEPTACLE: PROVIDE NEW 120V, 20A, DUPLEX IG RECEPTACLE. <br />OJUNCTION BOX IN CASEWORK: LOCATE J-BOX IN AN ACCESSIBLE AREA <br />WITHIN CASEWORK. <br />O TELE/DATA/POWER POLE: PROVIDE WIREMOLD 25DTC-4 OR EQUAL. PROVIDE <br />ALL REQUIRED ACCESSORIES FOR A COMPLETE AND FULLY FUNCTIONAL <br />TELE/DATA/POWER POLE. EXACT LOCATION OF POWER POLE SHALL BE <br />DETERMINED IN FIELD BY ARCHITECT AND OWNER FIELD REPRESENTATIVE. <br />O TELEPHONE AND DATA OUTLET: PROVIDE 1" C. FROM 4 11/16" X 4 11/16" DEEP <br />JUNCTION BOX UP TO AN ACCESSIBLE AREA ABOVE CEILING. INSTALL PULL <br />CORD FOR USE BY OTHERS. <br />O CONDUIT WHIP: PROVIDE 3/4" COATED FLEXIBLE METALLIC CONDUIT FROM <br />POWER POLE TO J-BOX IN CASEWORK. INSTALL 4 #12, 4 #12 NEUTRAL & 1 #12 <br />EG FOR EQUIPMENT LOADS 106(PL-31), 113A(PL-33), 113B(PL-35) AND <br />132(PL-12) . <br />O EMERGENCY FUEL SHUT-OFF PUSHBUTTON: RELOCATE EXISTING CASHIER <br />EMERGENCY FUEL SHUT-OFF PUSHBUTTON TO LOCATION INDICATED ON <br />PLAN. EXTEND CONDUIT AND WIRE AS REQUIRED. <br />O TELE/DATA/POWER POLE: PROVIDE WIREMOLD 25DTP-4 OR EQUAL. PROVIDE <br />ALL REQUIRED ACCESSORIES FOR A COMPLETE AND FULLY FUNCTIONAL <br />TELE/DATA/POWER POLE. MOUNT RECEPTACLE IN POWER POLE AND <br />CONNECT TO PL-28,30. POWER POLE LOCATION IS PROPOSED ONLY. EXACT <br />LOCATION POWER POLE SHALL BE DETERMINE IN FIELD BY ARCHITECT AND <br />OWNER FIELD REPRESENTATIVE. <br />O CONDUIT WHIP: PROVIDE 3/4" COATED FLEXIBLE METALLIC CONDUIT FROM <br />POWER POLE TO J-BOX IN CASEWORK. INSTALL 4 #12, 4 #12 NEUTRAL & 1 #12 <br />EG FOR EQUIPMENT LOADS 114(PL-2), 115(PL-4), VEND NUT/ VEND CHILI(PL-1) <br />AND 133(PL-22). <br />OLIGHTED CIGARETTE ADVERTISEMENT: CONNECT TO 120 VOLT SWITCHED <br />LIGHTING CIRCUIT. TIE TO EXISTING CIRCUIT FROM DEMOLITION WORK. <br />10 VISA/LOTTO RECEPTACLE: TIE TO EXISTING CIRCUIT FROM DEMOLITION <br />WORK. <br />11 POS TERMINAL RECEPTACLE: TIE TO EXISTING CIRCUIT FROM DEMOLITION <br />WORK. <br />12 SAFE RECEPTACLE: TIE TO EXISTING CIRCUIT FROM DEMOLITION WORK. <br />13 INTERCOM RECEPTACLE AND JUNCTION BOX FOR INTERCOM CABLES: TIE TO <br />EXISTING CIRCUIT FROM DEMOLITION WORK. <br />14 6"X6"X24" WIREWAY: WIREWAY FOR DATA CABLES. <br />15 2" EMPTY CONDUIT: PROVIDE 2" CONDUIT FROM WIREWAY AT CASHIER <br />CASEWORK TO TELEPHONE TERMINAL BOARD. INSTALL PULL CORD FOR USE <br />BY OTHERS. THIS CONDUIT IS FOR SITE DATA CABLES. <br />16 RELOCATED AUTOMATIC TANK GAUGE: EXTEND WIRE AND CONDUIT TO NEW <br />LOCATION. MATCH EXISTING CONDUIT AND WIRING IN SIZE AND TYPE. <br />EXTEND ALL LOW VOLTAGE CONDUCTORS TO TANKS AND FUELING <br />ACCESSORIES TO NEW AUTOMATIC TANK GAUGE LOCATION. <br />17 RELOCATED ATM: PROVIDE POWER/DATA AND CONNECT TO EXISTING <br />CIRCUIT FROM DEMOLITION WORK. EXTEND CONDUIT AND CONDUCTORS AS <br />REQUIRED. <br />18 HEAT PRODUCING EQUIPMENT UNDER HOOD: UPON ACTIVATION OF HOOD, <br />THE SOLENOID OPERATED GAS SHUT OFF VALVE SHALL CLOSE. <br />19 GREASE HOOD WITH FIRE SUPPRESSION: PROVIDE 120V TO LIGHTS AND <br />CONTROLS FOR HOOD. WIRE SUPPLY AIR FAN AND EXHAUST AIR FAN <br />THROUGH HOOD CONTROLLER. REFER TO LIGHTING PLAN FOR LIGHT <br />FIXTURE DETAILS. <br />NEW WORK LEGEND: <br />REFER TO PROPOSED PLANS FOR ADDITIONAL NOTES AND REQUIREMENTS. ALL <br />DEVICES, FIXTURES, AND EQUIPMENT SHOWN ON THE PROPOSED ELECTRICAL <br />PLAN IS NEW UNLESS NOTED OTHERWISE WITH THE BELOW DESIGNATIONS. <br />(e) SUBSCRIPT DENOTES EXISTING TO REMAIN. MAINTAIN SERVICE VIA <br />EXISTING CIRCUIT. <br />(n) SUBSCRIPT DENOTES NEW. <br />(r) SUBSCRIPT DENOTES EXISTING TO BE RELOCATED. MATCH EXISTING <br />WIRING AND CONDUIT AND EXTEND TO PROPOSED LOCATION. WIRING <br />DEVICES SHALL BE PROVIDED WITH NEW DEVICES AND COVER PLATES <br />TO MATCH NEW WORK. LIGHT FIXTURES SHALL BE CLEANED AND <br />RE-LAMPED. <br />(er) SUBSCRIPT DENOTES EXISTING DEVICE/FIXTURE TO BE REPLACED IN <br />SAME LOCATION AS EXISTING. RECONNECT NEW DEVICE/FIXTURE TO <br />EXISTING CIRCUIT. WIRING DEVICES SHALL BE REPLACED WITH NEW <br />DEVICES AND COVER PLATES TO MATCH NEW WORK. LIGHT FIXTURES <br />SHALL BE REPLACED WITH NEW FIXTURES PER LIGHTING FIXTURE <br />SCHEDULE. <br />DARK LINES INDICATE NEW, EXISTING TO BE RELOCATED, OR EXISTING <br />TO BE REPLACED. <br />LIGHT LINES INDICATE EXISTING TO REMAIN. <br />o� <br />o <br />0 <br />� <br />m <br />Wv�i <br />a <br />N <br />o <br />w <br />� <br />a <br />z° <br />INFINITY ENGINEERING <br />GRODUP,LLC <br />1208 East Kennedy Boulevard <br />Suite 230 <br />Tampa, Florida 33602 <br />[p]: 813.434.4770 <br />[f]: 813.445.4211 <br />www.iegroup.net <br />Cert. of Auth. No. 27889 <br />Client Name and Address <br />1201 OAKFIELD DRIVE, NO. 109 <br />BRANDON, FLORIDA 33509 <br />14 M`'YI E <br />FL.R O u I <br />No 7 7 <br />ZG19 _ <br />r <br />Z <br />N <br />J^ <br />CL <br />r> <br />0 <br />J <br />LL <br />0 <br />u� <br />J <br />J <br />LL <br />W <br />.j <br />C� <br />= <br />a <br />w <br />0 <br />cco <br />V <br />m <br />J <br />J <br />Q <br />A <br />L.L <br />N <br />O <br />_N <br />J <br />� <br />Q <br />LO <br />� <br />U <br />a <br />c <br />m <br />E <br />N <br />LL <br />zLij <br />°' U <br />1= <br />o <br />a <br />z J <br />cn L j J <br />Project No. <br />Sheet <br />140-88.00 <br />E-201 <br />Date <br />05103/2019 <br />Scale <br />AS NOTED <br />