Laserfiche WebLink
ELECTRICAL SPECIFICATIONS ( ANY REFEENCES IN THE MEP DOCUMENT TOLI EMUSPPROVID MENT D BY 0 HERS SHALL BE IGNORAND MATERIALS SHALL BEIEDDUNLEDSS THIS REF INSTLLEDB ENCOE IS ON R. HE A CHITECTURAL RESPONSIBILITIES SCHEDULE.T ) <br />16010 WORK INCLUDED: <br />1.1 CONTRACTOR SHALL PROVIDE THE FOLLOWING; <br />a. LABOR <br />b. SUPPLIES <br />c. MATERIALS <br />d. SHOP DRAWINGS <br />e. PERMITS AND INSPECTION FEES <br />f. CERTIFICATION OF FINAL INSPECTION AND APPROVAL <br />g, ONE YEAR GUARANTEE <br />1.2 CONTRACTOR SHALL PERFORM THE FOLLOWING; <br />a. INSTALLATION OF ALL ELECTRICAL EQUIPMENT. <br />b. COORDINATE WITH OTHER TRADES OF ELECTRICAL EQUIPMENT INSTALLATION <br />c. MATERIAL PROTECTION DURING CONSTRUCTION. <br />d. TEST OF ENTIRE SYSTEM IN PRESENCE OF OWNER OR HIS REPRESENTATIVE <br />AND CORRECT ANY DEFICIENCIES DISCOVERED. <br />e. COORDINATION OF ELECTRICAL SERVICE AND METERING WITH LOCAL POWER <br />COMPANY. <br />f. COORDINATION OF TELEPHONE SERVICE WITH LOCAL TELEPHONE COMPANY. <br />1.3 GOVERNING CODES SHALL BE THE FOLLOWING; <br />a. LOCAL MUNICIPALITY ELECTRICAL CODE. <br />b. PER LATEST NATIONAL ELECTRICAL CODE (NEC) <br />c. UTILITY COMPANY REGULATIONS <br />d. AMERICANS WITH DISABILITY ACT <br />e. CURRENT APPLICABLE BUILDING CODES <br />f. LOCAL BUILDING CODES AND ORDINANCES <br />g. THE NATIONAL MANUFACTURER'S ASSOCIATION STANDARDS (NEMA) <br />h. UNDERWRITER LABORATORIES INCORPORATED STANDARD(S) <br />i. AMERICAN NATIONAL STANDARD INSTITUTE (ANSI) <br />j. THE MANUFACTURER'S RECOMMENDATION <br />1.4 MATERIAL WILL BE; <br />a. NEW <br />b. UL LISTED <br />16110 RACEWAYS <br />1.1 USED AND TYPES <br />a. SERVICE ENTRANCE - RIGID STEEL <br />b. FEEDERS - RIGID STEEL EXCEPT ABOVE 8'-0" AND INDOOR <br />THEN EMT <br />c. BRANCH CIRCUIT, TELEPHONE OR COMMUNICATIONS - <br />EMT <br />d. IN EARTH OR CONCRETE - SCHEDULE 40 PVC <br />e. RECESSED LIGHTING FIXTURES - FLEXIBLE STEEL CONDUIT (SHORT BUT <br />MAXIMUM 72") <br />f. OUTDOOR FINAL CONNECTION TO EQUIPMENT OR IN WET LOCATIONS - LIQUID <br />TIGHT FLEXIBLE STEEL CONDUIT (MAXIMUM 36") <br />g. ALL RACEWAYS, UNLESS SPECIFICALLY INDICATED TO <br />BE EXPOSED, SHALL <br />BE CONCEALED IN WALLS, CEILING OR FLOORS. <br />h. PAINT ALL EXPOSED RACEWAYS COLOR AS DIRECTED <br />BY ARCHITECT. <br />1.2 CONDUIT BUSHING, <br />a. PROVIDE INSULATED CONDUIT BUSHING AT EACH END <br />OF EVERY CONDUIT <br />RUN. <br />16120 WIRES AND CABLES 600 VOLTS <br />1.1 COLOR CODING 208Y/120V 240-DELTA/120V <br />480Y/277V <br />PHASE A BLACK BLACK <br />BROWN <br />PHASE B BLUE ORANGE <br />YELLOW <br />PHASE C RED RED <br />ORANGE <br />NEUTRAL WHITE WHITE <br />WHITE <br />GROUND GREEN GREEN <br />GREEN <br />1.2 INSULATED, THHN, THWN, XHHW 75 DEGREE C. <br />1.3 PROVIDE COPPER WIRING UNLESS ALUMINUM IS SPECIFICALLY SHOWN ON THE <br />DRAWINGS. WHEN ALUMINUM CONDUCTORS ARE UTILIZED - PROVIDE COMPRESSION <br />LUG FITTINGS. <br />1.4 FIXTURE WIRE, 600 VOLTS, 200 DEGREE C. #14 AWG MINIMUM STRANDED, <br />TINNED COPPER NH SILICONE RUBBER INSULATION AND AN OVERALL JACKET OF <br />GLASS BRAID, AND RATED AS NEC TYPE 'SF-2' <br />16130 BOXES <br />1.1 ATTACHED SECURELY TO BUILDING CONSTRUCTION OR SUPPORT FROM SAME <br />1.2 MASONRY BOXES SHALL BE RACO OR STEEL CITY <br />1.3 EXPOSED BOXES SHALL BE CAST TYPE SIMILAR TO CROUSE HINDS TYPE FS <br />1.4 ALL OTHERS SHALL BE STAMPED STEEL <br />16140 WIRING DEVICES <br />1.1 RECEPTACLES <br />a. DUPLEX - 20 AMPS, 125V. AC GROUNDED UNO <br />b. SINGLE - 20 AMPS, 125V. AC GROUNDED UNO <br />c. COORDINATE COLOR OF DEVICE WITH ARCHITECT <br />d. COORDINATE FINISH AND COLOR OF COVERPLATE WITH ARCHITECT <br />1.2 WALL SWITCHES <br />a. SINGLE POLE - 20 AMPS, SINGLE THROW, QUIET TYPE, GROUNDED <br />b. COORDINATE COLOR OF DEVICE WITH ARCHITECT <br />c. COORDINATE FINISH AND COLOR OF COVERPLATE WITH ARCHITECT <br />1.3 TIME CLOCK <br />a. FURNISH AND INSTALL A TWENTY FOUR (24), SEVEN (7) DAY TIME CLOCK <br />INCLUDING ALL INTEGRAL WIRING AND LOAD BALANCING (PANEL) FOR CONTROLLING <br />THE STOREFRONT SIGN AND SHOW WINDOW LIGHTING, WHETHER SUCH WORK IS OR <br />IS NOT SHOWN ON PLANS OR SPECIFICATIONS <br />16170 PANELBOARDS <br />1.1 PANELBOARDS SHALL HAVE, BUT NOT BE LIMITED TO THE FOLLOWING; <br />a. THREE PHASE, 4 WIRE, COPPER BUSING, NEMA 1 ENCLOSURE FOR INDOOR, <br />NEMA 3R FOR OUTDOOR. <br />b. GROUND BUS WITH SET SCREW CONNECTIONS <br />c. SOLID NEUTRAL, 100% RATED WITH SET SCREW CONNECTION <br />d. SWITCH RATED BOLT -ON BREAKERS <br />e. TYPE WRITTEN DIRECTORY <br />f. PLAQUE, BLACK WITH 1" HIGH WHITE LETTERS TO INDICATE PANEL NAME <br />g. SQUARE D, EATON, GENERAL ELECTRIC OR SIEMENS <br />16190 GROUNDING <br />1.1 FEEDERS AND BRANCH CIRCUITS <br />a. PROVIDE A GREEN INSULATED GROUND CONDUCTOR, SIZED PER THE NEC IN <br />EACH RACEWAY <br />16200 LIGHTING FIXTURES <br />1.1 COORDINATE FIXTURE TRIMS WITH CEILING IN/ON WHICH IT IS BEING INSULATED. <br />1.2 MATCH VOLTAGE OF FIXTURE TO CIRCUIT TO WHICH FIXTURE IS SHOWN <br />CONNECTED <br />1.3 PROVIDE LOW TEMPERATURE HIGH EFFICIENCY ELECTRONIC BALLASTS IN <br />FLUORESCENT FIXTURES <br />1.4 PROVIDE THERMAL OVERLOAD PROTECTION IN BOTH FLUORESCENT AND <br />INCANDESCENT FIXTURES <br />1.5 NARRATIVE DESCRIPTION IN LIGHTING FIXTURE SCHEDULE TAKES PRECEDENCE <br />OVER CATALOG NUMBER <br />1.6 PROVIDE INTEGRAL DISCONNECTING MEANS FOR ALL FLUORESCENT FIXTURES <br />PER THE NEC <br />16210 EXISTING CONDITION <br />1.1 VISIT SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS IN AND AROUND <br />THE BUILDINGS <br />16220 TELEPHONE SERVI <br />1.1 SAFETY SWITCHES SHALL BE HEAVY DUTY TYPE, 600 OR 250 VOLT, WITH <br />NUMBER OF POLES REQUIRED. FUSED SAFETY SWITCHES SHALL BE QUICK -MAKE, <br />QUICK -BREAK MECHANISM, VISIBLE BLADES WITH REJECTION TYPE FUSE CLIPS AND <br />NEMA CLASS "LPJ" FUSES, THE SWITCHES SHALL BE NEMA 313 FOR OUTDOOR. ALL <br />SWITCHES SHALL BE LOCKABLE. <br />16270 FIRE ALARM SYSTEM - AS APPLICABLE, CHECK REQUIREMENTS AGAINST <br />ARCHITECTURAL DRAWINGS. <br />'FIRE ALARMZSPRINKLER DRAWINGS, WHERE NECESSARY, WILL BE SUBMITTED <br />SEPARATELY UNDER A SEPARATE PERMIT BY A LICENSED FIRE PROTECTION <br />'ONTRACTOR - DESIGN BUILD). <br />1.1 FURNISH AND INSTALL FIRE ALARM POWER BOOSTER TO EXISTING BUILDING <br />FIRE ALARM PANEL AS INDICATED ON DRAWINGS. THE FIRE ALARM SYSTEM NEW <br />DEVICES SHALL BE FORMALLY PLANNED BY A LICENSED FIRE ALARM CONTRACTOR <br />WHO SHALL SUBMIT SIGNED AND SEALED DRAWINGS, IF REQUIRED FOR PERMIT, AND <br />SHALL SUPERVISE AND CERTIFY THE INSTALLATION. FIRE ALARM SYSTEM <br />CONTRACTOR SHALL REVIEW THE MECHANICAL DRAWINGS AND PROVIDE AND <br />INSTALL DUCT SMOKE DETECTORS AS REQUIRED IN THE STANDARD MECHANICAL <br />CODE AND BY THE LOCAL FIRE MARSHALL. DESIGN SHALL COMPLY WITH NFPA 72. <br />PROVIDE VOCE EVACUATION MODULES WITH ALL NECESSARY APPURTENANCES. <br />1.2 REMOTE ANNUNCIATOR <br />PROVIDE AN ALPHANUMERIC ANNUNCIATOR WITH INTEGRAL ALPHANUMERIC <br />DISPLAY, SYSTEM CONTROL/TEST SWITCHES, KEY OPERATED ENABLED SWITCH AND <br />BACK BOX. COORDINATE LOCATION WITH AUTHORITY HAVING JURISDICTION PRIOR <br />TO ROUGH -IN. <br />1.3 MANUAL STATIONS <br />PROVIDE ANALOG ADDRESSABLE MANUAL STATIONS WITH PROTECTIVE COVERS <br />(WITH INTEGRAL HORN AND 9V BATTERY) AS SHOWN ON THE PLANS. <br />1.4 SYSTEM SMOKE DETECTORS <br />PROVIDE ANALOG ADDRESSABLE PHOTOELECTRIC SMOKE DETECTORS WITH <br />BASES AS SHOWN, SUPPLEMENT AS DIRECTED BY BUILDING OFFICIAL. <br />1.5 DUCT MOUNTED SMOKE DETECTORS <br />PROVIDE DUCT MOUNTED ANALOG ADDRESSABLE PHOTOELECTRIC SMOKE <br />DETECTORS WITH SAMPLING TUBES AND ADDRESSABLE CONTROL RELAYS AS SHOWN <br />ON THE PLANS AND AS REQUIRED TO COMPLY WITH THE MECHANICAL CODE. <br />WHERE IN -DUCT SMOKE DETECTORS ARE INSTALLED IN CONCEALED LOCATIONS <br />MORE THEN 10 FEET ABOVE THE FINISHED FLOOR OR N ARRANGEMENT WHERE THE <br />DETECTORS ALARM OR SUPERVISORY INDICATOR IS NOT VISIBLE TO RESPONDING <br />PERSONNEL, THE DETECTOR SHALL BE PROVIDED WITH REMOTE ALARM OR <br />SUPERVISORY INDICATION IN A LOCATION ACCEPTABLE TO THE AUTHORITY HAVING <br />JURISDICTION. ADDITIONALLY, LABEL REMOTE ALARMS TO INDICATE BOTH THEIR <br />FUNCTION AND THE AIR HANDLING UNIT(S) ASSOCIATED WITH EACH DETECTOR. <br />1.6 ADDRESSABLE MONITOR MODULES <br />PROVIDE ADDRESSABLE MONITOR MODULES AS SHOWN ON THE PLANS TO <br />MONITOR SPRINKLER FLOW SWITCHES, SPRINKLER VALVES, SUPERVISORY SWITCHES <br />AND SPRINKLER FIRE PUMP (AS REQUIRED) <br />1.7 ADDRESSABLE CONTROL MODULES <br />PROVIDE ADDRESSABLE CONTROL MODULES AS REQUIRED FOR INTERFACE WITH <br />THE ELEVATOR CONTROLS, ELEVATOR POWER CONTROLS AND HVAC CONTROLS (AS <br />REQUIRED) <br />1.8 ALARM SIGNALS <br />PROVIDE 15/75-WW SPEAKER/STROBE ALARM SIGNALS AS SHOWN ON THE <br />PLANS FOR ALL PUBLIC AREAS. PROVIDE 15/75-WW STROBE VISUAL ALARM <br />SIGNALS FOR ALL STROBE ONLY LOCATIONS AS SHOWN ON THE PLANS, 110 <br />CANDELA. <br />1.9 WIRING <br />WIRING SHALL BE CONCEALED IN CONDUIT. PROVIDE WIRING AND CONDUIT AS <br />DIRECTED BY THE MANUFACTURER'S AUTHORIZED DISTRIBUTOR. <br />1.10 APPLICABLE CODES AND STANDARDS <br />ALL EQUIPMENT SHALL BE UL LISTED FOR ITS INTENDED USE. <br />ALL RACEWAYS AND WIRING SHALL BE INSTALLED IN COMPLIANCE WITH NFPA <br />STANDARD 70 (NATIONAL ELECTRIC CODE) <br />NFPA STANDS 71 AND 72 <br />NFPA 101 (LIFE SAFETY CODE) <br />AMERICANS WITH DISABILITIES ACT (ADA) <br />STANDARD BUILDING CODE (SBC) <br />APPLICABLE LOCAL AND NATIONAL CODES AND AUTHORITIES HAVING <br />JURISDICTION <br />1.11 SYSTEM OPERATION <br />ACTUATION OF ANY FIRE ALARM INITIATING DEVICE SHALL IMMEDIATELY CAUSE <br />THE FOLLOWING ACTIONS TO BE INITIATED <br />a. IDENTIFY THE TYPE OF ALARM, SPECIFIC DEVICE AND LOCATION ON THE <br />BACK LIT LCD DISPLAY AT THE BUILDING FIRE ALARM CONTROL PANEL AND AT THE <br />REMOTE ANNUNCIATORS <br />b. CAUSE THE SYSTEM ALARM LED TO FLASH AT THE FIRE ALARM CONTROL <br />PANEL <br />c. CAUSE ALL SYSTEM HORNS TO SOUND <br />d. CAUSE ALL VISUAL ALARMS SIGNALS TO FLASH <br />e. ACTIVATE THE DIGITAL COMMUNICATOR TO REPORT THE TYPE OF ALARM <br />AND LOCATION TO THE REMOTE CENTRAL MONITORING STATION. COORDINATE <br />CONNECTIONS WITH OWNER'S REPRESENTATIVE. <br />f. ACTIVATE SIGNALS TO THE BUILDING DOOR LOCK CONTROLS TO DEACTIVATE <br />LOCKS <br />g. ACTIVATE SIGNALS TO THE HVAC CONTROLS TO INITIATE SHUT DOWN OR <br />REROUTING OF AIR HANDLING SYSTEMS <br />1.12 ACTIVATION OF ANY SPRINKLER VALVE SUPERVISORY SWITCH SHALL <br />AUTOMATICALLY <br />a. CAUSE THE SYSTEM SUPERVISORY LED TO FLASH AND AN AUDIBLE <br />INDICATOR TO SOUND AT THE CONTROL PANEL AND REMOTE ANNUNCIATOR <br />b. IDENTIFY THE SUPERVISORY CONDITION, SPECIFIC DEVICE AND LOCATION ON <br />THE BACK LIT LCD DISPLAY AT THE SYSTEM CONTROL PANEL AND THE REMOTE <br />ANNUNCIATOR. <br />1. LIGHTING LAYOUTS SHOWN ARE INTENDED TO INDICATE DESIRED FIXTURE <br />LOCATIONS AND SWITCHING. <br />2. COMPLY WITH THE LATEST VERSIONS OF ALL APPLICABLE NATIONAL, STATE AND <br />LOCAL CODES. <br />3. THE DIRECTIVE, IF ANY, OF THE BUILDING OFFICIAL SHALL TAKE PRECEDENCE <br />OVER THIS DRAWING REGARDING LOCATION AND NUMBER OF EXIT AND EMERGENCY <br />EGRESS LIGHTS. <br />4. ALL FIXTURES TO BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. <br />5. ALL PENDANT HUNG FIXTURES SHALL BE SUPPORTED DIRECTLY FROM <br />STRUCTURE ABOVE WITH NO. 9 GAGE WIRE OR APPROVED ALTERNATE SUPPORT <br />WITHOUT USING CEILING SUSPENSION SYSTEM FOR DIRECT SUPPORT. <br />6. ALL LIGHTING FIXTURES MUST BE SUPPORTED BY #12 GAUGE WIRE ATTACHED TO <br />THE GRID MEMBERS WITHIN 3" OF EACH CORNER OF EACH FIXTURE. <br />7. REFER TO DRAWING LIGHTING LEGEND FOR DETAIL INFORMATION ON LIGHTING. <br />8. REFER TO DRAWING E3.0 FOR POWER AND PANEL SCHEDULE. <br />9. GENERAL CONTRACTOR TO PROVIDE AND INSTALL ALL FIXTURES AND LAMPS, <br />EXCEPT FOR THOSE LISTED AS EXISTING, IN THE LIGHT FIXTURE SCHEDULE. <br />10. WHEN DIRECTED BY OWNER, GENERAL CONTRACTOR TO SALVAGE ALL 2'X4' <br />LIGHT FIXTURES IN KITCHEN. RELAMP FIXTURES, CLEAN AND REINSTALL PER <br />REFLECTED CEILING PLAN. <br />11. ALL RACEWAYS IN MILLWORK SHALL BE RUN CONCEALED FROM VIEW. <br />12. ROUTE CIRCUIT THROUGH SWITCH ON SWITCH BANK. COORDINATE LOCATION <br />OF SWITCH BANK WITH OWNER. <br />13. ELECTRICAL CONTRACTOR TO VERIFY LIGHTING FOR WALK IN COOLER & <br />FREEZER. PROVIDE FIXTURE IF COOLER DOES NOT HAVE BUILT-IN LIGHT, OR <br />COOLER LIGHTING IS NOT EXISTING. COORDINATE INSTALLED LOCATION WITH <br />SUPPLIER. <br />14. ALL DEDICATED CIRCUIT OUTLETS SHALL BE ORANGE. <br />15. ALL 20 AMP 125 VOLT RECEPTACLES IN THE KITCHEN AREAS SHALL BE GFCI <br />PROTECTED AND ACCESSIBLE. <br />16. EXIT FIXTURES TO BE CIRCUITED BY UNSWITCHED LEG AND TO PROVIDE <br />CONTINUOUS ILLUMINATION PER NEC 700-12(A) AND NFPA 101, LIFE SAFETY CODE <br />17. PROVIDE DUAL LEVEL SWITCHING IN KITCHEN IN ACCORDANCE WITH IECC <br />REQUIREMENTS. PROVIDE ALL LIGHTING WITH DUAL BALLAST FOR SEPARATE <br />CONTROL OF INBOARD & OUTBOARD LAMPS. <br />18. HOOD EQUIPMENT FROM VENDOR; ELECTRICAL PANELS ASSOCIATED WITH HOOD <br />EQUIPMENT. COORDINATE WIRING & INSTALLATION OF EQUIPMENT WITH HOOD <br />CONTRACTOR. ROUE CIRCUITS FOR EQUIPMENT UNDER HOODS THROUGH SHUNT <br />TRIP. E.C. TO INTEGRATE HOOD ELECTRICAL SYSTEMS. SEE DETAIL ON HOOD <br />DRAWINGS <br />19. T.G.C. SHALL INSTALL A MINIMUM OF 3 OUTLETS IN THE DINING ROOM. <br />LOCATION SHALL BE DETERMINED BY TENANT. <br />20. FOR ADDITIONAL INSTALLATION INSTRUCTIONS SEE ARCHITECTURAL SHEETS. <br />21. THE SCOPE OF THE ELECTRICAL WORK SHALL INCLUDE FURNISHING, INSTALLING <br />AND TESTING ALL ELECTRICAL SYSTEMS FOR A COMPLETE AND FULLY OPERABLE <br />INSTALLATION. COMPLY WITH THE LATEST VERSIONS OF ALL APPLICABLE NATIONAL, <br />STATE AND LOCAL CODES. <br />22. LOCATIONS OF EXISTING ELECTRICAL SYSTEMS, EQUIPMENT AND DEVICES SHALL <br />BE VERIFIED IN THE FIELD BY THE TGC. <br />23. POWER LAYOUTS SHOWN ARE INTENDED TO INDICATE DESIRED LOCATIONS. <br />24. VERIFY ELECTRICAL REQUIREMENTS FOR ALL SPECIAL EQUIPMENT PRIOR TO ANY <br />WORK BEING PERFORMED. PROVIDE ISOLATED GROUND WIRE PER EQUIP. <br />MANUFACTURER'S INSTALLATION REQUIREMENTS. PROVIDE CONDUIT FOR MECHANICAL <br />CONTROLS AS MAY BE REQUIRED BY CODE. ELECTRICAL CONTRACTOR SHALL <br />COORDINATE WITH MECHANICAL CONTRACTOR AS TO LOCATION OF A/C UNITS AND <br />EXHAUST FANS. <br />25. ALL POWER CIRCUITS SHALL BE INSTALLED BY AN ELECTRICIAN LICENSED IN <br />THE JURISDICTION OF THE PROJECT. <br />26. ALL BUSSING AND WIRING SHALL BE COPPER, UNLESS EXPLICITLY NOTED <br />ELSEWHERE IN THIS DOCUMENT SET. <br />27. ELECTRICAL CONTRACTOR SHALL PROVIDE LEGIBLE LABELING OF ALL BREAKERS <br />ON PANELBOARDS. <br />28. ELECTRICAL CONTRACTOR TO SIZE AND PROVIDE ALL ELECTRICAL JUNCTION <br />BOXES, PULL BOXES, AND CONVENIENCE OUTLETS. <br />29. ELECTRICAL CONTRACTOR SHALL DETERMINE, ARRANGE FOR PROPER SERVICE <br />AND METERS, FEES PAID BY E.C.. <br />30. ELECTRICAL CONTRACTOR TO PROVIDE ALL NECESSARY POWER TO ROOF AND <br />CONNECT ALL ROOF -MOUNTED EQUIPMENT. <br />31. ELECTRICAL CONTRACTOR TO PROVIDE SERVICE DISCONNECTS. <br />32. ELECTRICAL CONTRACTOR SHALL PROVIDE, AT EACH TELEPHONE JACK <br />INDICATED, AN OUTLET BOX, CONDUIT AND TRIM. THE CONDUIT SHALL EXTEND <br />ABOVE SUSPENDED CEILING. PROVIDE CONDUCTOR TELEPHONE WIRE AS REQUIRED <br />TO EACH BOX. REMOTE UNITS & INSTALL DISCONNECTS CAD ALL A/C UNITS. <br />33. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY POWER AND <br />PERFORM FINAL CONNECTIONS TO EXTERIOR SIGNAGE. <br />34. ELECTRICAL CONTRACTOR SHALL INSTALL & CONNECT THE ICE MACHINES. <br />NEITHER THE TENANT'S GENERAL CONTRACTOR NOR ANY SUBCONTRACTOR IS TO <br />START THE ICE MACHINE. A MANUFACTURER'S REPRESENTATIVE WILL INITIATE THE <br />START UP OF ICE MACHINE. <br />35. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO FURNISH & INSTALL <br />CORDS & PLUGS AS REQUIRED FOR THE DISHWASHER, & ICE MACHINE. <br />36. WHEN MAIN ELECTRICAL SERVICE IS PROVIDED BY THE LANDLORD, HIS <br />OBLIGATIONS TERMINATE AT THE DISCONNECT. ALL PANELS, FEEDERS, ETC. <br />REQUIRED FOR THE CONSTRUCTION OF THIS PROJECT SHALL BE FURNISHED & <br />INSTALLED BY THE E.C. <br />37. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH ALL <br />TRADES AND VERIFY THAT ALL EQUIPMENT SHIPPED TO THE SITE IS COMPATIBLE <br />WITH MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS PRIOR TO INSTALLATION OF <br />SAID EQUIPMENT. IN THE EVENT OF ANY DISCREPANCIES, IMMEDIATELY CONTACT <br />DESIGNER BEFORE PROCEEDING. <br />38. ELECTRICAL CONTRACTOR TO INTERLOCK GREASE EXHAUST FANS, MAKE-UP AIR <br />SUPPLY FANS AND ROOF -TOP UNITS, AS DESCRIBED ON SHEET MEP1.0. <br />39. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL LOCAL DISCONNECT <br />SWITCH, MOUNTED INSIDE BUILDING FOR EXTERIOR SIGNAGE. PROVIDE TIME CLOCK <br />FOR CONTROL OF EXTERIOR SIGN. JUNCTION BOX FOR EXTERIOR SIGNAGE SHALL BE <br />MOUNTED ON THE EXTERIOR SPACE/FRAME. COORDINATE EXACT LOCATION AND <br />REQUIREMENTS WITH SIGN VENDOR AND OWNER. <br />40. STARERS & RELATED WIRING SHALL BE FURN'D & INSTD BY E.C. OVERLOAD <br />LIMITS SHALL BE INSTALLED PER GIVEN NAMEPLATE DATA ON EQUIPMENT. <br />STARTERS SHALL BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS. <br />41. DISCONNECT SWITCHES SHALL BE FURN'D & INSTD BY E.C. <br />42. ELECTRICAL CONTRACTOR SHALL CONTACT LOCAL UTILITY COMPANY FOR <br />SERVICE AND TRANSFORMER REQUIREMENTS AND SHALL INCLUDE ALL WORK IN <br />HIS/HER BID. <br />43. ELECTRICAL CONTRACTOR SHALL CONTACT LOCAL UTILITY COMPANY & VERIFY <br />SERVICE VOLTAGE AND SHALL REVISE & BALANCE PANELS AS REQUIRED. <br />44. ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL OUTLET FIRE PROTECTION <br />PAD FOR ALL RECEPTACLES IN RATED WALLS AS MANUFACTURED BY PFP <br />PARTNERS. APPLY TO BOXES AS INSTRUCTED BY MFR. TO PROVIDE RATING TO <br />MEET RATING OF CORRESPONDING WALL. <br />45. MOUNT RECEPTACLE ABOVE WINDOW FOR USE AT STOREFRONT. <br />46. PROVIDE POWER TO JUNCTION BOX & CONNECT WIRE CORD DROP HEAT LAMPS <br />THROUGH JUNCTION BOX. <br />47. ELECTRICAL CONTRACTOR TO PROVIDE POWER FOR THE DISHWASHER ON A GFI <br />BREAKER. COORDINATE LOCATION OF RECEPTACLE NH EQUIPMENT SUPPLIER. <br />48. ELECTRICAL CONTRACTOR TO PROVIDE REMOTE RESET FOR RTU SMOKE <br />DETECTORS. <br />49. EMERGENCY PULL STATION SWITCH FOR HOOD, FURNISHED AND INSTALLED BY <br />ANSUL CONTRACTOR. <br />50. ELECTRICAL CONTRACTOR TO PROVIDE AND WIRE DISCONNECT & RECEPTACLE <br />FOR RTUs/AHUs &CUs. <br />51. ELECTRICAL CONTRACTOR SHALL WIRE THE DOOR HEAT 'TRACE' FROM ONE OF <br />THE LEGS OF THE ELECTRICAL SERVICE FROM THE PANEL TO THE COOLER OR <br />FREEZER. <br />52. WHERE PORTIONS OF A CABLE RACEWAY OR SLEEVE ARE KNOWN TO BE <br />SUBJECTED TO DIFFERENT TEMPERATURES AND WHERE CONDENSATION IS KNOWN TO <br />BE AN ISSUE, AS IN COLD STORAGE AREAS OF BUILDINGS OR WHERE PASSING <br />FROM THE INTERIOR TO THE EXTERIOR OF A BUILDING, THE RACEWAY OR SLEEVE <br />SHALL BE FILLED WITH AN APPROVED MATERIAL TO PREVENT THE CIRCULATION OF <br />WARM AIR TO COLDER SECTION OF THE RACEWAY OR SLEEVE PER NEC 300.7 (A). <br />53. CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH UTILITY COMPANY <br />AND PROVIDE GEAR WITH A SCCR GREATER THAN AVAILABLE FAULT. <br />DATA CABLE TERMINATION: <br />ALL CABLE RUNS SHALL BE TERMINATED WITH A PUNCH -DOWN, OR "KEYSTONE" <br />CAT-5E RJ45 JACK (PANDUIT P/N MUJC588BEI OR EQUIVO WITH FACEPLATE <br />INSTALLED & LABELED. THE WIRING OF THIS JACK SHALL BE TO EIA/TIA 568E <br />STANDARD (PAIR 1=BLUE, PAIR 2=ORANGE, PAIR 3=GREEN, & PAIR 4=BROWN) ON <br />BOTH ENDS OF THE RUN (STRAIGHT THROUGH, NOT CROSS OVER). THE FACEPLATE <br />& ELECTRICAL BOX IN BACK OF IT SHALL ONLY HAVE THE DATA CABLE RUNS <br />ASSOCIATED WITH POS SYSTEM GOING TO IT (NO TELEPHONE, COAX AC LINES, ETC). <br />IF MORE THAN ONE DATA CABLE IS GOING TO A LOCATION, THE FACEPLATE CAN <br />BE SHARED WITH OTHER POS SYSTEM RUNS. TERMINATION MUST BE WITHIN 5 FEET <br />OF WHERE EACH WORKSTATION WILL BE LOCATED. AT THE BACK OFFICE/NETWORK <br />HUB LOCATION, A CAT-5E PATCH PANEL (110 STYLE WITH RJ45's ON FRONT) CAN <br />BE EMPLOYED TO MINIMIZE THE NUMBER OF INDIVIDUAL RJ45 JACKS REQUIRED. THIS <br />PANEL OR SET OF JACKS MUST BE LOCATED WITHIN 5 FEET OF THE BACK OFFICE <br />COMPUTER/NETWORK HUB, & MUST BE LABELED. LABELING OF JACKS SHOULD BE <br />IN A LOGICAL SEQUENCE (e.g. POS1, POS2, KP1, KP2, ETC). <br />USE OF "PATCH CABLES" <br />PATCH CABLES MAY BE USED TO CONNECT TERMINALS/WORKSTATIONS TO WALL <br />JACKS, TERMINALS/WORKSTATIONS TO RECEIPT PRINTERS, HUBS/SWITCHES TO WALL <br />JACKS/PATCH PANELS, REMOTE PRINTERS TO WALL JACKS, ETC. THE MAXIMUM <br />LENGTH OF THESE PATCH CABLES IS 2 METERS, OR 7 FEET. THE MINIMUM <br />SPECIFICATION OF THESE CABLES IS CAT-5E, WITH STRANDED WIRE BEING USED. <br />IF THESE PATCH CABLES NEED TO BE "WIRE -TIED" TO FACILITATE A CLEANER <br />INSTALLATION, THIS MUST BE DONE SO THAT THE MINIMUM DIAMETER OF THE <br />BUNDLE IS 4". IN NO EVENT SHALL THIS BUNDLE BE "SMASHED TOGETHER" AND <br />CINCHED SO TIGHT THE JACKET OF THE CABLE IS DEPRESSED. THE USE OF PATCH <br />CABLES LONGER THAN 2 METERS IS HIGHLY DISCOURAGED, AS THIS INTRODUCES <br />TOO MANY CHANCES FOR COMPROMISING THE INTEGRITY OF THE DATA NETWORK. <br />CARE SHOULD ALSO BE TAKEN NOT TO INTRODUCE SUB-CAT-5E (I.E. CAT-5, <br />CAT-3) PATCH CABLES INTO A SYSTEM. <br />120VAC DUPLEX OUTLET: <br />THE PREFERRED TYPE WOULD BE AN ISOLATED GROUND OUTLET (INDUSTRY <br />STANDARD ORANGE IN COLOR). IF THIS IS NOT AVAILABLE, A "REGULAR" OUTLET IS <br />SUITABLE, AS LONG AS THERE IS NOTHING ELSE ON THE SAME CIRCUIT BESIDES <br />THE POS EQUIPMENT, & IT IS WIRED CORRECTLY (INCLUDING GROUND). THIS MEANS <br />NO COFFEE MAKERS, SODA MACHINES, SIGNAGE, REFRIGERATION EQUIPMENT, ETC. IN <br />ADDITION, WHETHER THE OUTLETS ARE ISOLATED GROUND OR "CONVENTIONAL", <br />THEY ALL NEED TO SHARE A SINGLE DISTRIBUTION PANEL. <br />POS SYSTEM MINIMUM SPECIFICATIONS AND REQUIREMENTS: <br />AC POWER <br />AC POWER REQUIREMENTS: <br />EACH WORKSTATION LOCATION, KITCHEN/REMOTE PRINTER LOCATION, AND BACK <br />OFFICE/NETWORK HUB LOCATION SHALL HAVE A 120VAC DUPLEX OUTLET (INDUSTRY <br />STANDARD NEMA 5-20R OR EQUIV.) WITHIN 5 FEET OF THE LOCATION. THE <br />PREFERRED TYPE WOULD BE A DEDICATED, ISOLATED GROUND OUTLET (INDUSTRY <br />STANDARD ORANGE IN COLOR). IF THIS IS NOT AVAILABLE, A "REGULAR" DUPLEX <br />RECEPTACLE IS ACCEPTABLE, AS LONG AS THERE IS NOTHING ELSE ON THE SAME <br />CIRCUIT BESIDES THE POS EQUIPMENT, AND IT IS WIRED CORRECTLY (INCLUDING <br />GROUND). THIS MEANS NO COFFEE MAKERS, SODA MACHINES, SIGNAGE, <br />REFRIGERATION EQUIPMENT, ETC. IN ADDITION, WHETHER THE OUTLETS ARE <br />DEDICATED, ISOLATED GROUND OR "CONVENTIONAL", THEY ALL NEED TO SHARE A <br />SINGLE DISTRIBUTION PANEL. <br />IN A TYPICAL SYSTEM, EACH WORKSTATION/RECEIPT PRINTER COMBINATION WOULD <br />DRAW A MAXIMUM OF ABOUT 2 AMPS OF POWER. THIS MEANS THAT IN A 3 OR <br />4-TERMINAL ALOHA SYSTEM, FOR EXAMPLE, THE ENTIRE SYSTEM (INCLUDING <br />FILESERVER) MAY BE ON ONE SEPERATE CIRCUIT. IN FACT, THIS IS THE <br />PREFERABLE METHOD AS ALL DEVICES WOULD BE ON THE SAME "GROUND -PLANE" <br />(COMMON PANEL/SUBPANEL), AND NOTHING ELSE WOULD BE ON THAT CIRCUIT TO <br />INTRODUCE UNWANTED ELECTRICAL INTERFERENCE. <br />THE COMCHECK REPORT IS CONSIDERED PART OF THE MEP DOCUMENT <br />SET. CONTRACTOR SHALL COMPLY WITH ALL ENERGY CODE <br />REQUIREMENTS. <br />Peter A. Leptuch, P.E. <br />300 N. Carroll Blvd. #20C <br />Denton, TX 76201 <br />(940) 735-5127 <br />Stud i o RG.,..., <br />MAIN OFFICE: <br />1 HUNTINGTON QUADRANGLE <br />SUITE 2CO3 <br />MELVILLE, NY 11747 <br />P: 631.226-7700 F: 631.226.7175 <br />©Copyright 2018: RGBK, INC. <br />Seal: <br />Landry <br />GREG LAN DRY <br />AROVEOURE nAWING IN'r Eit _O Dt S*N <br />1202 �ichardsen Dr. #106 Tel; =214 631.6941 <br />Rchardson, Texas 75080 Fax::214.634.1814 <br />No 72679 •, �. <br />•: <br />STATE- 0 <br />c � <br />(1j✓s <br />��V <br />Owner: <br />George Morkos <br />2520 Colony Reed Lane <br />Clearwater, FL33763 <br />It is the responsibility of the Construction <br />Manager/General Contractor and all <br />Sub -Contractors to verify all dimensions and <br />accept conditions of prior work by related <br />trades before proceeding with any work. <br />Date <br />07-22-2020 <br />Drawn By <br />Check By <br />MRP <br />TN <br />Scale <br />AS SHOWN <br />Issued: <br />Rev. <br />No. <br />Description <br />Issued for Review <br />Project Title <br />Charleys <br />Zephyrhills <br />WM706 <br />Project Address <br />7631 Gall Blvd, <br />Zephyrhills, FL 33541 <br />Project Number <br />WM706 <br />Drawing Title and Number <br />ELECTRICAL <br />SPECIFICATIONS <br />E4.0 <br />