Laserfiche WebLink
ROOF -TOP UNIT SCHEDULE (EXISTING, EO. TO:) <br />MARK <br />DESCRIPTION <br />EER/IEER <br />SUPPLY <br />0/A <br />OPERATING <br />LECTRICA <br />COOLING <br />EXISTING <br />MCA <br />MOCP <br />NOTES: <br />CFM <br />CFFM <br />HEAT <br />RTU-1 <br />AAON RK-010 10T <br />(EXISTING) <br />EX. <br />EX. <br />4,000 <br />800 <br />EX. <br />480V/3� <br />EX. FFEE <br />102,000 <br />30 KW <br />— <br />(EX. ) <br />13,11,12 <br />RTU-2 <br />AAON RK-06 5T <br />(EXISTING) <br />EX. <br />EX. <br />2,000 <br />400 <br />EX. <br />480V 3 <br />EX. EE� <br />60'000F2OKW <br />— <br />(EX.) <br />3,11,12 <br />1. LABEL EACH RTU AND EXHAUST FAN WITH "CHARLEYS" AND SUITE NUMBER. <br />2. COOLING CAPACITY IS BASED ON 807 EDB AND 677 EWB CONDITIONS. <br />3. PROVIDE PROGRAMMABLE ROOM THERMOSTAT, HONEYWELL TH8000 SERIES. <br />4. PROVIDE UNWIRED CONVENIENCE OUTLET (ELECTRICIAN SHALL FIELD WIRE TO 208V <br />PANEL) AND 14" ROOF CURB. <br />5. VERIFY VOLTAGE AVAILABLE ON SITE PRIOR TO ORDERING NEW UNITS. OBTAIN STRUCTURAL <br />APPROVAL PRIOR TO <br />PLACING UNIT. <br />6. UNIT PROVIDED WITH DUAL COMPRESSORS/2—STAGE COOLING. <br />7. PROVIDE FACTORY ELECTROAN OR EQUAL ANTI —CORROSION COATING ON OUTDOOR <br />COILS. <br />8. WEIGHTS INCLUDE ACCESSORIES. <br />9. ORDER WITH ACCESSORIES INCLUDING: CURB, ECONOMIZER, HAIL GUARD, 2—POSI1ION DAMPER, DUAL ENTHALPY <br />SENSORS, DUCT DETECTORS, ETC. <br />10. MCA BASED ON MEDIUM STATIC FAN. <br />11. LANDLORD TO FULLY SERVICE AND WARRANTY FOR ONE(1) YEAR. <br />12. BRING EXISTING UNIT TO LIKE NEW OPERATING AND PERFORMANCE CONDITIONS. COMB OUT FINS, CHANGE BELTS, <br />IF NEW RTUS ARE NECESSARY, G.C. <br />BRING TO FACTORY SPEC REFRIGERANT LEVELS. <br />SHALL ORDER 2—STAGE COOLING <br />I <br />13. HIGH EFFICIENCY UNIT. <br />VERSION OF UNITS - <br />FAN SCHEDULE <br />MARK <br />EF-1 11 <br />REFER TO HOOD DRAWINGS, SHEETS M5.0 THRU M5.4. <br />THIS PROJECT IS AN INTERIOR REMODEL OF AN EXISTING WALMART STORE LEASE SPACE. THE <br />SPACE IS BEING DELIVERED TO CONTRACTOR IN AS —IS CONDITION. ALL WORK TO COMPLETE <br />AND DELIVER A FULLY OPERATIONAL SPACE IS BY THE G.C. THE G.C. SHALL VISIT THE JOB <br />SITE PRIOR TO BID AND SHALL SUPPLEMENT WHAT IS SHOWN IN THIS DOCUMENT SET WITH <br />FIELD OBSERVATIONS TO ENSURE AN ACCURATE BID. THE INTENT OF THE DESIGN IS TO <br />CREATE AS MUCH EXISTING HVAC SYSTEM EQUIPMENT THAT IS SUITABLE FOR REUSE (SIZE, <br />CAPACITY & CONDITION). SUPPLEMENT EXISTING WITH NEW TO SUBSTANTIALLY REACH THE <br />DESIGN AS INDICATED. <br />AIR DEVICE SCHEDULE <br />SYMBOL <br />TAG <br />MANUFACTURER <br />CATALOG NUMBER <br />FIXTURE DESCRIPTION <br />REMARKS <br />El <br />A—P <br />TITUS <br />PAS <br />24x24 SUPPLY GRILLE <br />ALUMINUM PERFORATED <br />AIR SUPPLY, BORDER <br />TYPE 1 IN GYP, BD. CLG. <br />17 <br />A <br />TITUS <br />OMNI <br />24x24 SUPPLY GRILLE <br />ALUMINUM, BORDER TYPE <br />1 IN GYP, BD. CLG. <br />D <br />B <br />TITUS <br />355FLF1 <br />24x24 RETURN GRILLE <br />1 IN GYP, BD. CLG., <br />I <br />FILTER TYPE WITH HINGE. <br />® <br />C <br />TITUS <br />OMNI <br />12x12 SUPPLY GRILLE <br />ALUMINUM, BORDER TYPE <br />1 IN GYP, BD. CLG. <br />D <br />TITUS <br />ML-38 <br />SLOTS, 3/4", 24" <br />BORDER, CONCEALED <br />p <br />MOUNTING <br />® <br />E <br />TITUS <br />350FL <br />12x24 TRANSFER <br />ALUMINUM, BORDER TYPE <br />GRILLE <br />1 IN GYP, BD. CLG. <br />NOTE: <br />1. ALL GRILLES IN GYP BOARD CEILING SHALL BE ORDERED WITH INTEGRAL BALANCING DAMPERS. <br />2. NOT ALL DEVICES USED ON ALL JOBS. <br />3. REMOVE PATTERN CONTROLLERS FROM PERFORATED SUPPLY GRILLES WITHIN 6' OF HOOD. <br />AIR BALANCE SCHEDULE <br />UNIT <br />SUPPLY <br />RETURN <br />OUTSIDE <br />EXHAUST <br />PRESSURE <br />AREA <br />AIR <br />AIR <br />AIR <br />SERVED <br />(EX) <br />RTU-1 <br />4,000 <br />3,200 <br />800 <br />-- <br />+800 <br />KITCHEN <br />(EX) <br />RTU-2 <br />2,000 <br />1,600 <br />400 <br />-- <br />+400 <br />SALES <br />EF-1 <br />(KITCHEN HOOD) <br />2850 <br />—2,850 <br />KITCHEN <br />XFR. THR. <br />STOREFRONT <br />-- <br />-- <br />-- <br />+1,650 <br />RESTAURANT <br />TOTAL <br />6,000 <br />4,800 <br />1 1,200 <br />1 2,850 <br />NEUTRAL <br />-- <br />RTUS SHALL HAVE BAROMETRIC RELIEVE AND FULL—SIZE ECONOMIZER. <br />MECHANICAL LEGEND <br />® SUPPLY AIR DUCT OR GRILLE <br />z RETURN AIR DUCT OR GRILLE, FILTER TYPE <br />RIGID TRUNK DUCT <br />RIGID BRANCH DUCT <br />�,- FLEX DUCT <br />—� BALANCING DAMPER <br />R.A. RETURN AIR <br />S.A. SUPPLY AIR <br />O DUCT SMOKE DETECTOR <br />S0 REMOTE SENSOR FOR THERMOSTAT +72" AFF. <br />H0 HUMIDITY AIR SENSOR +72" AFF. <br />TO THERMOSTAT +48" AFF. <br />O MOTORIZED DAMPER <br />O.A. OUTSIDE AIR <br />F.D. COMBINATION FIRE/SMOKE DAMPER <br />FOR EQUIP. INFORMATION REFER TO EQUIPMENT <br />SCHEDULES. FOR NOTE BY SYMBOL INFORMATION <br />REFER TO NOTES BY SYMBOL EACH SHEET. <br />*NOT ALL SYMBOLS USED ON ALL JOBS <br />DUCT SCHEDULE <br />AIR FLOW (CFM) <br />ROUND NECK SIZE <br />0 — 100 <br />6" <br />101 — 200 <br />8» <br />201 — 300 <br />10" <br />301 — 500 <br />12" <br />501 — 700 <br />14" <br />NOTES: <br />1. NECK SIZES SHALL BE <br />SIZED AS PER FLEX DUCT <br />SCHEDULE, EXCEPT RETURN GRILLES, WHICH HAVE <br />NOMINAL SIZE NECK. <br />2. USE THIS TABLE ONLY <br />WHERE DUCT SIZES ARE <br />MISSING FROM PLANS. <br />3. USE THESE SIZES UNLESS A LARGER SIZE IS <br />SHOWN ON THE PLANS. <br />I CONDENSATE LINE SIZES: I <br />3/4" <br />UP <br />TO <br />20 TONS CONNECTED. <br />1" <br />UP <br />TO <br />21-40 TONS CONNECTED. <br />1-1/4" <br />UP <br />TO <br />41-90 TONS CONNECTED. <br />1-1/2" <br />UP <br />TO <br />91-125 TONS CONNECTED. <br />2" <br />UP <br />TO <br />126-250 TONS CONNECTED. <br />*ROUTE TO APPROVED RECEPTOR VIA AIR GAP. <br />HVAC SUMMARY: <br />15.0 TONS <br />1,938 SF* <br />*TOTAL AREA <br />129.2 SF/TON <br />ZEPHYRHILLS, FL NOTE: <br />THE EXISTING HVAC UNIT SCHEDULE <br />IS ASSUMED, BASED ON LIMITED <br />SITE DATA AND PROTOTYPICAL <br />WALMART EQUIPMENT. CONTRACTOR <br />SHALL FIELD VERIFY EXACT <br />MAKE/MODEL AND GAS INPUT, ETC. <br />AND REPORT ANY DISCREPANCIES <br />TO THE ENGINEER IMMEDIATELY. <br />NOTES BY SYMBOL: <br />OROOFTOP UNIT, REFER TO EQUIPMENT SCHEDULE, THIS <br />SHEET. PROVIDE FLEXIBLE CONNECTORS FOR THE <br />SUPPLY AND RETURN AIR DUCT CONNECTIONS. <br />TRANSITION TO DUCT SIZES SHOWN. PROVIDE DUCT <br />WORK AND AIR DISTRIBUTION DEVICES AS INDICATED ON <br />THE PLAN. REFER TO EQUIPMENT SCHEDULES FOR <br />ADDITIONAL REQUIREMENTS. CONFIRM SUPPLY AND <br />RETURN DROP LOCATIONS IN FIELD. VERIFY LOCATIONS <br />OF EXISTING UNITS IN FIELD. NOTIFY ENGINEER IF <br />NEIGHBORING EXHAUST IS WITHIN 10'-0" OF UNIT <br />INTAKE FOR NEW UNIT PLACEMENT. <br />O18"0 (2850 CFM.) EXHAUST RISER UP FROM TYPE-1 <br />HOOD COLLAR, TRANSITION TO EXHAUST FAN DUCT <br />OPENING. VELOCITY OF EXHAUST DUCT AT 1500 FPM. <br />LOCATE FAN ON ROOF 10'-0" FROM FRESH AIR <br />INTAKES. PROVIDE BACK DRAFT DAMPER. <br />OPROGRAMMABLE THERMOSTAT HONEYWELL VISION PRO <br />8000 WITH REMOTE SENSOR, RELATED WIRING, NIGHT <br />SETBACK FEATURE AND LOCKING COVER. MOUNT <br />T—STAT ® 48"A.F.F. AND SENSOR AT 72"A.F.F.. <br />COORDINATE EXACT LOCATION WITH OWNER ON SITE. <br />PROVIDE AND INSTALL FOR RTU-1, AND RTU-2. <br />O GREASE DUCT SHALL BE WELDED BLACK IRON OR <br />STAINLESS STEEL, SEALED VAPOR TIGHT, INSPECTED, <br />THEN COVERED WITH TWO LAYERS OF LISTED FYRE <br />WRAP OR EQUAL PRODUCT TO ALLOW FOR ZERO <br />CLEARANCE TO COMBUSTIBLES. A UL—LISTED GREASE <br />DUCT BY CAPTIVE AIRE MAY OMIT FYREWRAP WHERE <br />LISTED TO DO SO, PER MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS. <br />O 1" LINED RETURN AIR DUCT. <br />© PROVIDE SUPPLY AIRSTREAM DUCT SMOKE DETECTOR. <br />O7 TYPE-1 HOOD, MECHANICAL CONTRACTOR SHALL <br />INSTALL COMPLETE SYSTEM AS REQUIRED, INCLUDING <br />ALL ANSUL AND CONTROL SYSTEMS. REFER TO <br />CAPTIVE AIR VENDOR DRAWINGS. <br />O8 INTERLOCK RTU-1 & RTU-2 (FANS) WITH HOOD <br />EXHAUST FANS SO THAT WHEN THE HOOD IS IN USE <br />THE EXHAUST FANS (EF-1) AND RTU(S) FANS WILL RUN <br />TOGETHER, TO MAINTAIN PROPER BUILDING <br />PRESSURIZATION. COMPRESSOR TO CYCLE AS COOLING <br />IS NEEDED. <br />O VOLUME/BALANCING DAMPER (TYPICAL). <br />10 HVAC UNIT DUCT DROP LOCATIONS ARE DIAGRAMMATIC, <br />ADJUST DUCTWORK, DROP CONNECTIONS AND ROUTING <br />AS NEEDED BASED ON ACTUAL FIELD CONDITIONS. <br />11 CONTRACTOR SHALL PROVIDE PERFORATED TYPE SUPPLY <br />GRILLE WITH PATTERN CONTROLLERS REMOVED. <br />12 TRAP AND ROUTE 3/4" CONDENSATE LINE TO <br />APPROVED RECEPTOR BY AHJ. ROUTE DOWN WITHIN <br />WALL AND TERMINATE ABOVE RIM LINE OF SINK WITH 90 <br />DEGREE ELBOW. <br />ZEPHYRHILLS, FL NOTE: <br />THE EXISTING WATER HEATER AND HVAC <br />UNITS WILL REMAIN AS —IS. NO <br />MECHANICAL ENERGY CALCS ARE NEEDED. <br />REFER TO SUPPLEMENTARY COMCHECK <br />REPORT FOR LIGHTING ENERGY CALCS. <br />ZEPHYRHILLS, FL NOTE: <br />ALL CONDENSATE HANDLING SYSTEM <br />COMPONENTS SUCH AS CONDENSATE <br />PIPE, DRAIN PANS, ETC. SHALL BE <br />INSULATED PER FLORIDA <br />BUILDING/PLUMBING/MECHANICAL CODE. <br />HVAC DUCT ROUTING SHOWN IN <br />DIAGRAMMATIC. THE INTENT IS <br />TO REUSE DUCTWORK WHEREVER' <br />POSSIBLE. FIT DIFFUSERS TO <br />NEW GRID. EQUIVALENT <br />RECTANGULAR DUCTWORK MAY <br />BE USED IN LIEU OF THE ROUND <br />SIZES INDICATED ON PLANS. <br />w <br />X <br />0 <br />rn <br />a <br />J <br />3 <br />\—OUTDOORS--,,,\ <br />WALMART STORE <br />PLAN <br />NORTH <br />MECHANICAL PLAN <br />SCALE: 1 /4" = 1'-0" <br />Peter A. Leptuch, P.E. <br />300 N. Carroll Blvd. #20 <br />Denton, TX 76201 <br />(940) 735-5127 <br />FINAL PLACEMENT OF <br />THERMOSTATS TO BE SELECTED <br />BY CONSTRUCTION MANAGER <br />OR OWNER'S REPRESENTATIVE <br />AND MAY NEED TO BE <br />MODIFIED DUE TO FIELD <br />CONDITIONS. <br />1// <br />Q <br />J <br />3 <br />StudioRG_ <br />MAIN OFFICE: <br />1 HUNTINGTON QUADRANGLE <br />SUITE 2CO3 <br />MELVILLE, NY 11747 <br />P: 631.226-7700 F: 631.226.7175 <br />© Copyright 2018: RGBK, INC. <br />Lan,dry <br />ARCHITECTURE (MANNING INTERIOR DESIGN <br />1202 Richardsm Dr. #106 Tek.214.631:6441 <br />Fichardson, Texas 75GBO Fax; .214.634.1814 <br />Seal: <br />�i✓ �� ~yam 4n <br />-79 <br />720 <br />e J y. <br />;'. SiAT OF •• <br />Owner: <br />George Morkos <br />2520 Colony Reed Lane <br />Clearwater, FL33763 <br />It is the responsibility of the Construction <br />Manager/General Contractor and all <br />Sub -Contractors to verify all dimensions and <br />accept conditions of prior work by related <br />trades before proceeding with any work. <br />Date <br />07-22-2020 <br />Drawn By Check By <br />MRP TN <br />Scale <br />AS SHOWN <br />Issued: <br />Project Title <br />Charleys <br />Zephyrhills <br />WM706 <br />Project Address <br />I� <br />7631 Gall Blvd, <br />Zephyrhills, FL 33541 <br />Project Number <br />WM706 <br />Drawing Title and Number <br />MECHANICAL PLAN <br />