ROOF -TOP UNIT SCHEDULE (EXISTING, EO. TO:)
<br />MARK
<br />DESCRIPTION
<br />EER/IEER
<br />SUPPLY
<br />0/A
<br />OPERATING
<br />LECTRICA
<br />COOLING
<br />EXISTING
<br />MCA
<br />MOCP
<br />NOTES:
<br />CFM
<br />CFFM
<br />HEAT
<br />RTU-1
<br />AAON RK-010 10T
<br />(EXISTING)
<br />EX.
<br />EX.
<br />4,000
<br />800
<br />EX.
<br />480V/3�
<br />EX. FFEE
<br />102,000
<br />30 KW
<br />—
<br />(EX. )
<br />13,11,12
<br />RTU-2
<br />AAON RK-06 5T
<br />(EXISTING)
<br />EX.
<br />EX.
<br />2,000
<br />400
<br />EX.
<br />480V 3
<br />EX. EE�
<br />60'000F2OKW
<br />—
<br />(EX.)
<br />3,11,12
<br />1. LABEL EACH RTU AND EXHAUST FAN WITH "CHARLEYS" AND SUITE NUMBER.
<br />2. COOLING CAPACITY IS BASED ON 807 EDB AND 677 EWB CONDITIONS.
<br />3. PROVIDE PROGRAMMABLE ROOM THERMOSTAT, HONEYWELL TH8000 SERIES.
<br />4. PROVIDE UNWIRED CONVENIENCE OUTLET (ELECTRICIAN SHALL FIELD WIRE TO 208V
<br />PANEL) AND 14" ROOF CURB.
<br />5. VERIFY VOLTAGE AVAILABLE ON SITE PRIOR TO ORDERING NEW UNITS. OBTAIN STRUCTURAL
<br />APPROVAL PRIOR TO
<br />PLACING UNIT.
<br />6. UNIT PROVIDED WITH DUAL COMPRESSORS/2—STAGE COOLING.
<br />7. PROVIDE FACTORY ELECTROAN OR EQUAL ANTI —CORROSION COATING ON OUTDOOR
<br />COILS.
<br />8. WEIGHTS INCLUDE ACCESSORIES.
<br />9. ORDER WITH ACCESSORIES INCLUDING: CURB, ECONOMIZER, HAIL GUARD, 2—POSI1ION DAMPER, DUAL ENTHALPY
<br />SENSORS, DUCT DETECTORS, ETC.
<br />10. MCA BASED ON MEDIUM STATIC FAN.
<br />11. LANDLORD TO FULLY SERVICE AND WARRANTY FOR ONE(1) YEAR.
<br />12. BRING EXISTING UNIT TO LIKE NEW OPERATING AND PERFORMANCE CONDITIONS. COMB OUT FINS, CHANGE BELTS,
<br />IF NEW RTUS ARE NECESSARY, G.C.
<br />BRING TO FACTORY SPEC REFRIGERANT LEVELS.
<br />SHALL ORDER 2—STAGE COOLING
<br />I
<br />13. HIGH EFFICIENCY UNIT.
<br />VERSION OF UNITS -
<br />FAN SCHEDULE
<br />MARK
<br />EF-1 11
<br />REFER TO HOOD DRAWINGS, SHEETS M5.0 THRU M5.4.
<br />THIS PROJECT IS AN INTERIOR REMODEL OF AN EXISTING WALMART STORE LEASE SPACE. THE
<br />SPACE IS BEING DELIVERED TO CONTRACTOR IN AS —IS CONDITION. ALL WORK TO COMPLETE
<br />AND DELIVER A FULLY OPERATIONAL SPACE IS BY THE G.C. THE G.C. SHALL VISIT THE JOB
<br />SITE PRIOR TO BID AND SHALL SUPPLEMENT WHAT IS SHOWN IN THIS DOCUMENT SET WITH
<br />FIELD OBSERVATIONS TO ENSURE AN ACCURATE BID. THE INTENT OF THE DESIGN IS TO
<br />CREATE AS MUCH EXISTING HVAC SYSTEM EQUIPMENT THAT IS SUITABLE FOR REUSE (SIZE,
<br />CAPACITY & CONDITION). SUPPLEMENT EXISTING WITH NEW TO SUBSTANTIALLY REACH THE
<br />DESIGN AS INDICATED.
<br />AIR DEVICE SCHEDULE
<br />SYMBOL
<br />TAG
<br />MANUFACTURER
<br />CATALOG NUMBER
<br />FIXTURE DESCRIPTION
<br />REMARKS
<br />El
<br />A—P
<br />TITUS
<br />PAS
<br />24x24 SUPPLY GRILLE
<br />ALUMINUM PERFORATED
<br />AIR SUPPLY, BORDER
<br />TYPE 1 IN GYP, BD. CLG.
<br />17
<br />A
<br />TITUS
<br />OMNI
<br />24x24 SUPPLY GRILLE
<br />ALUMINUM, BORDER TYPE
<br />1 IN GYP, BD. CLG.
<br />D
<br />B
<br />TITUS
<br />355FLF1
<br />24x24 RETURN GRILLE
<br />1 IN GYP, BD. CLG.,
<br />I
<br />FILTER TYPE WITH HINGE.
<br />®
<br />C
<br />TITUS
<br />OMNI
<br />12x12 SUPPLY GRILLE
<br />ALUMINUM, BORDER TYPE
<br />1 IN GYP, BD. CLG.
<br />D
<br />TITUS
<br />ML-38
<br />SLOTS, 3/4", 24"
<br />BORDER, CONCEALED
<br />p
<br />MOUNTING
<br />®
<br />E
<br />TITUS
<br />350FL
<br />12x24 TRANSFER
<br />ALUMINUM, BORDER TYPE
<br />GRILLE
<br />1 IN GYP, BD. CLG.
<br />NOTE:
<br />1. ALL GRILLES IN GYP BOARD CEILING SHALL BE ORDERED WITH INTEGRAL BALANCING DAMPERS.
<br />2. NOT ALL DEVICES USED ON ALL JOBS.
<br />3. REMOVE PATTERN CONTROLLERS FROM PERFORATED SUPPLY GRILLES WITHIN 6' OF HOOD.
<br />AIR BALANCE SCHEDULE
<br />UNIT
<br />SUPPLY
<br />RETURN
<br />OUTSIDE
<br />EXHAUST
<br />PRESSURE
<br />AREA
<br />AIR
<br />AIR
<br />AIR
<br />SERVED
<br />(EX)
<br />RTU-1
<br />4,000
<br />3,200
<br />800
<br />--
<br />+800
<br />KITCHEN
<br />(EX)
<br />RTU-2
<br />2,000
<br />1,600
<br />400
<br />--
<br />+400
<br />SALES
<br />EF-1
<br />(KITCHEN HOOD)
<br />2850
<br />—2,850
<br />KITCHEN
<br />XFR. THR.
<br />STOREFRONT
<br />--
<br />--
<br />--
<br />+1,650
<br />RESTAURANT
<br />TOTAL
<br />6,000
<br />4,800
<br />1 1,200
<br />1 2,850
<br />NEUTRAL
<br />--
<br />RTUS SHALL HAVE BAROMETRIC RELIEVE AND FULL—SIZE ECONOMIZER.
<br />MECHANICAL LEGEND
<br />® SUPPLY AIR DUCT OR GRILLE
<br />z RETURN AIR DUCT OR GRILLE, FILTER TYPE
<br />RIGID TRUNK DUCT
<br />RIGID BRANCH DUCT
<br />�,- FLEX DUCT
<br />—� BALANCING DAMPER
<br />R.A. RETURN AIR
<br />S.A. SUPPLY AIR
<br />O DUCT SMOKE DETECTOR
<br />S0 REMOTE SENSOR FOR THERMOSTAT +72" AFF.
<br />H0 HUMIDITY AIR SENSOR +72" AFF.
<br />TO THERMOSTAT +48" AFF.
<br />O MOTORIZED DAMPER
<br />O.A. OUTSIDE AIR
<br />F.D. COMBINATION FIRE/SMOKE DAMPER
<br />FOR EQUIP. INFORMATION REFER TO EQUIPMENT
<br />SCHEDULES. FOR NOTE BY SYMBOL INFORMATION
<br />REFER TO NOTES BY SYMBOL EACH SHEET.
<br />*NOT ALL SYMBOLS USED ON ALL JOBS
<br />DUCT SCHEDULE
<br />AIR FLOW (CFM)
<br />ROUND NECK SIZE
<br />0 — 100
<br />6"
<br />101 — 200
<br />8»
<br />201 — 300
<br />10"
<br />301 — 500
<br />12"
<br />501 — 700
<br />14"
<br />NOTES:
<br />1. NECK SIZES SHALL BE
<br />SIZED AS PER FLEX DUCT
<br />SCHEDULE, EXCEPT RETURN GRILLES, WHICH HAVE
<br />NOMINAL SIZE NECK.
<br />2. USE THIS TABLE ONLY
<br />WHERE DUCT SIZES ARE
<br />MISSING FROM PLANS.
<br />3. USE THESE SIZES UNLESS A LARGER SIZE IS
<br />SHOWN ON THE PLANS.
<br />I CONDENSATE LINE SIZES: I
<br />3/4"
<br />UP
<br />TO
<br />20 TONS CONNECTED.
<br />1"
<br />UP
<br />TO
<br />21-40 TONS CONNECTED.
<br />1-1/4"
<br />UP
<br />TO
<br />41-90 TONS CONNECTED.
<br />1-1/2"
<br />UP
<br />TO
<br />91-125 TONS CONNECTED.
<br />2"
<br />UP
<br />TO
<br />126-250 TONS CONNECTED.
<br />*ROUTE TO APPROVED RECEPTOR VIA AIR GAP.
<br />HVAC SUMMARY:
<br />15.0 TONS
<br />1,938 SF*
<br />*TOTAL AREA
<br />129.2 SF/TON
<br />ZEPHYRHILLS, FL NOTE:
<br />THE EXISTING HVAC UNIT SCHEDULE
<br />IS ASSUMED, BASED ON LIMITED
<br />SITE DATA AND PROTOTYPICAL
<br />WALMART EQUIPMENT. CONTRACTOR
<br />SHALL FIELD VERIFY EXACT
<br />MAKE/MODEL AND GAS INPUT, ETC.
<br />AND REPORT ANY DISCREPANCIES
<br />TO THE ENGINEER IMMEDIATELY.
<br />NOTES BY SYMBOL:
<br />OROOFTOP UNIT, REFER TO EQUIPMENT SCHEDULE, THIS
<br />SHEET. PROVIDE FLEXIBLE CONNECTORS FOR THE
<br />SUPPLY AND RETURN AIR DUCT CONNECTIONS.
<br />TRANSITION TO DUCT SIZES SHOWN. PROVIDE DUCT
<br />WORK AND AIR DISTRIBUTION DEVICES AS INDICATED ON
<br />THE PLAN. REFER TO EQUIPMENT SCHEDULES FOR
<br />ADDITIONAL REQUIREMENTS. CONFIRM SUPPLY AND
<br />RETURN DROP LOCATIONS IN FIELD. VERIFY LOCATIONS
<br />OF EXISTING UNITS IN FIELD. NOTIFY ENGINEER IF
<br />NEIGHBORING EXHAUST IS WITHIN 10'-0" OF UNIT
<br />INTAKE FOR NEW UNIT PLACEMENT.
<br />O18"0 (2850 CFM.) EXHAUST RISER UP FROM TYPE-1
<br />HOOD COLLAR, TRANSITION TO EXHAUST FAN DUCT
<br />OPENING. VELOCITY OF EXHAUST DUCT AT 1500 FPM.
<br />LOCATE FAN ON ROOF 10'-0" FROM FRESH AIR
<br />INTAKES. PROVIDE BACK DRAFT DAMPER.
<br />OPROGRAMMABLE THERMOSTAT HONEYWELL VISION PRO
<br />8000 WITH REMOTE SENSOR, RELATED WIRING, NIGHT
<br />SETBACK FEATURE AND LOCKING COVER. MOUNT
<br />T—STAT ® 48"A.F.F. AND SENSOR AT 72"A.F.F..
<br />COORDINATE EXACT LOCATION WITH OWNER ON SITE.
<br />PROVIDE AND INSTALL FOR RTU-1, AND RTU-2.
<br />O GREASE DUCT SHALL BE WELDED BLACK IRON OR
<br />STAINLESS STEEL, SEALED VAPOR TIGHT, INSPECTED,
<br />THEN COVERED WITH TWO LAYERS OF LISTED FYRE
<br />WRAP OR EQUAL PRODUCT TO ALLOW FOR ZERO
<br />CLEARANCE TO COMBUSTIBLES. A UL—LISTED GREASE
<br />DUCT BY CAPTIVE AIRE MAY OMIT FYREWRAP WHERE
<br />LISTED TO DO SO, PER MANUFACTURER'S INSTALLATION
<br />INSTRUCTIONS.
<br />O 1" LINED RETURN AIR DUCT.
<br />© PROVIDE SUPPLY AIRSTREAM DUCT SMOKE DETECTOR.
<br />O7 TYPE-1 HOOD, MECHANICAL CONTRACTOR SHALL
<br />INSTALL COMPLETE SYSTEM AS REQUIRED, INCLUDING
<br />ALL ANSUL AND CONTROL SYSTEMS. REFER TO
<br />CAPTIVE AIR VENDOR DRAWINGS.
<br />O8 INTERLOCK RTU-1 & RTU-2 (FANS) WITH HOOD
<br />EXHAUST FANS SO THAT WHEN THE HOOD IS IN USE
<br />THE EXHAUST FANS (EF-1) AND RTU(S) FANS WILL RUN
<br />TOGETHER, TO MAINTAIN PROPER BUILDING
<br />PRESSURIZATION. COMPRESSOR TO CYCLE AS COOLING
<br />IS NEEDED.
<br />O VOLUME/BALANCING DAMPER (TYPICAL).
<br />10 HVAC UNIT DUCT DROP LOCATIONS ARE DIAGRAMMATIC,
<br />ADJUST DUCTWORK, DROP CONNECTIONS AND ROUTING
<br />AS NEEDED BASED ON ACTUAL FIELD CONDITIONS.
<br />11 CONTRACTOR SHALL PROVIDE PERFORATED TYPE SUPPLY
<br />GRILLE WITH PATTERN CONTROLLERS REMOVED.
<br />12 TRAP AND ROUTE 3/4" CONDENSATE LINE TO
<br />APPROVED RECEPTOR BY AHJ. ROUTE DOWN WITHIN
<br />WALL AND TERMINATE ABOVE RIM LINE OF SINK WITH 90
<br />DEGREE ELBOW.
<br />ZEPHYRHILLS, FL NOTE:
<br />THE EXISTING WATER HEATER AND HVAC
<br />UNITS WILL REMAIN AS —IS. NO
<br />MECHANICAL ENERGY CALCS ARE NEEDED.
<br />REFER TO SUPPLEMENTARY COMCHECK
<br />REPORT FOR LIGHTING ENERGY CALCS.
<br />ZEPHYRHILLS, FL NOTE:
<br />ALL CONDENSATE HANDLING SYSTEM
<br />COMPONENTS SUCH AS CONDENSATE
<br />PIPE, DRAIN PANS, ETC. SHALL BE
<br />INSULATED PER FLORIDA
<br />BUILDING/PLUMBING/MECHANICAL CODE.
<br />HVAC DUCT ROUTING SHOWN IN
<br />DIAGRAMMATIC. THE INTENT IS
<br />TO REUSE DUCTWORK WHEREVER'
<br />POSSIBLE. FIT DIFFUSERS TO
<br />NEW GRID. EQUIVALENT
<br />RECTANGULAR DUCTWORK MAY
<br />BE USED IN LIEU OF THE ROUND
<br />SIZES INDICATED ON PLANS.
<br />w
<br />X
<br />0
<br />rn
<br />a
<br />J
<br />3
<br />\—OUTDOORS--,,,\
<br />WALMART STORE
<br />PLAN
<br />NORTH
<br />MECHANICAL PLAN
<br />SCALE: 1 /4" = 1'-0"
<br />Peter A. Leptuch, P.E.
<br />300 N. Carroll Blvd. #20
<br />Denton, TX 76201
<br />(940) 735-5127
<br />FINAL PLACEMENT OF
<br />THERMOSTATS TO BE SELECTED
<br />BY CONSTRUCTION MANAGER
<br />OR OWNER'S REPRESENTATIVE
<br />AND MAY NEED TO BE
<br />MODIFIED DUE TO FIELD
<br />CONDITIONS.
<br />1//
<br />Q
<br />J
<br />3
<br />StudioRG_
<br />MAIN OFFICE:
<br />1 HUNTINGTON QUADRANGLE
<br />SUITE 2CO3
<br />MELVILLE, NY 11747
<br />P: 631.226-7700 F: 631.226.7175
<br />© Copyright 2018: RGBK, INC.
<br />Lan,dry
<br />ARCHITECTURE (MANNING INTERIOR DESIGN
<br />1202 Richardsm Dr. #106 Tek.214.631:6441
<br />Fichardson, Texas 75GBO Fax; .214.634.1814
<br />Seal:
<br />�i✓ �� ~yam 4n
<br />-79
<br />720
<br />e J y.
<br />;'. SiAT OF ••
<br />Owner:
<br />George Morkos
<br />2520 Colony Reed Lane
<br />Clearwater, FL33763
<br />It is the responsibility of the Construction
<br />Manager/General Contractor and all
<br />Sub -Contractors to verify all dimensions and
<br />accept conditions of prior work by related
<br />trades before proceeding with any work.
<br />Date
<br />07-22-2020
<br />Drawn By Check By
<br />MRP TN
<br />Scale
<br />AS SHOWN
<br />Issued:
<br />Project Title
<br />Charleys
<br />Zephyrhills
<br />WM706
<br />Project Address
<br />I�
<br />7631 Gall Blvd,
<br />Zephyrhills, FL 33541
<br />Project Number
<br />WM706
<br />Drawing Title and Number
<br />MECHANICAL PLAN
<br />
|