My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7631 Gall Blvd (21)
Zephyrhills
>
Building Department
>
Building Plans
>
7631 Gall Blvd (21)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:43:28 AM
Creation date
2/25/2025 4:19:13 PM
Metadata
Fields
Template:
Building Plans
Street #
7631
Location
Gall Blvd
Contractor
AAA Plumb and Septic
Building Plans - Permit #
3261
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ZEPHYRHILLS, FL NOTE: <br />REUSE EXISTING <br />ROOF -MOUNTED GALVANIZED <br />METAL CONDENSATE HANDLING <br />PIPE REPAIR CONNECTIONS AT <br />RTU AS EACH UNIT. <br />LINE SIZES SHOWN HERE ARE BASED ON HIGH PRESSURE GAS <br />UP TO REGULATOR (300' TOTAL DEVELOPED LENGTH) AND <br />LOW PRESSURE GAS PIPE BEYOND (60' TOTAL DEVELOPED <br />LENGTH). THESE SIZES REPRESENT MINIMUM LINE SIZES. <br />NOTIFY ENGINEER FOR RESIZING IF CONDITIONS IN FIELD <br />DIFFER FROM WHAT IS SHOWN HERE. <br />WALMART <br />TENANT <br />SPACE <br />ASSUMED <br />RTU-1 <br />(ELECTRIC) <br />375 CFH <br />I <br />SOLENOID <br />VALVE. <br />I <br />I <br />PROVIDE REGULATOR S <br />EXISTING 5PSI GAS a 1AS NEEDED. <br />METER 3-/ <br />EXTEND PIPING FROM <br />1-1/2" <br />o AREA OF OLD HOOD TO <br />375/CFH <br />1- 1 2" Fr AREA OF NEW HOOD. <br />1- I �`' <br />CONCEAL NEW PIPING <br />CFH <br />w FROM VIEW, EXCEPT FOR <br />PIPING BEHIND COOKING <br />Oj <br />EQUIPMENT. <br />#K2 1 <br />— — <br />PR -1 M "'(, J <br />LG. FRYER <br />L — — J <br />L J 170 CFH <br />TENANT'S G.C. SHALL COORDINATE INSTALLATION OF <br />NEW GAS METER <br />ISOLATION <br />VALVE (WHERE NECESSARY) WITH LOCAL UTILITY COMPANY. <br />TYPICALLY <br />EXISTING SERVICE IS ADEQUATE FOR CHARLEYS NEEDS WITHOUT <br />UPGRADING. LINES ARE SIZED FOR HIGH PRESSURE <br />GAS, 5 PSI <br />PRESSURE UP TO REGULATOR, AND LOW PRESSURE <br />GAS, LESS THAN <br />2 PSI WITH 0.5 IN. W.C. PRESSURE DROP BEYOND REGULATOR. <br />PROVIDE ADDITIONAL REGULATORS AS NEEDED. <br />GAS SUPPLY DIAGRAM <br />SCALE: NOT TO SCALE <br />I HVAC SEQUENCE OF OPERATION <br />ASSUMED <br />RTU-2 <br />(ELECTRIC) <br />ROOF <br />#K2.2 I #K1.1 <br />SM. FRYERJ GRIDDLE <br />85 CFH 120 CFH <br />DIRT LEG. TYPICAL AT <br />EACH PIECE OF GAS <br />UTILIZING EQUIPMENT. <br />GAS LOAD SUMMARY <br />COOKLINE #1 <br />SM FRYER 85 CFH <br />LG FRYER 170 CFH <br />GRIDDLE 120 CFH <br />TOTAL 375 CFH <br />NOTES BY SYMBOL: <br />OCCUPIED MODE <br />O1 ROOFTOP UNIT, REFER TO EQUIPMENT SCHEDULE SHEET M1. PROVIDE <br />RTU 1 (KITCHEN <br />AREA) SEQUENCE: <br />FLEXIBLE CONNECTORS FOR THE SUPPLY AND RETURN AIR DUCT <br />COOLING MODE: <br />COMMAND FROM TEMP SENSOR (RTU-1 SET AT 72'F, <br />ADJUSTABLE) CALLS <br />FOR COOLING, <br />CONNECTIONS. TRANSITION TO DUCT SIZES SHOWN. <br />THE OSA DAMPER SHALL BE OPEN TO MIN POSITION. <br />SUPPLY FAN SHALL <br />ENERGIZE AND <br />THE UNIT SHALL CYCLE COMPRESSOR ON AS NEEDED <br />TO MAINTAIN SPACE <br />TEMPERATURE <br />O 18"0 (2850 CFM) EXHAUST RISER UP FROM TYPE 1 HOOD COLLAR, <br />SET POINT. <br />TRANSITION TO EXHAUST FAN DUCT OPENING. OFFSET AS <br />HEATING MODE: <br />COMMAND FROM TEMP SENSORS (RTU-1 SET AT 68'F, <br />ADJUSTABLE) CALLS FOR HEATING, <br />NECESSARY TO CLEAR OUTSIDE AIR INTAKE ON RTU AND/OR <br />THE OSA DAMPER SHALL BE OPEN TO MIN POSITION. <br />SUPPLY FAN SHALL <br />ENERGIZE AND <br />JOIST/BEAM LOCATIONS BY 10'-0". A DIRECT VERTICAL RUN IS <br />THE ELECTRIC STRIP SHALL ENERGIZE AS NEEDED TO <br />MAINTAIN SPACE TEMPERATURE SET <br />ANTICIPATED EXCEPT AS NEEDED TO AVOID STRUCTURAL ELEMENTS. <br />POINT. <br />RTU 2 (DINING AREA) SEQUENCE: <br />COOLING MODE: COMMAND FROM TEMP SENSOR (RTU-2 SET AT 72'F, ADJUSTABLE). ADJUSTABLE CALLS <br />FOR COOLING, <br />THE <br />OSA DAMPER <br />SHALL BE OPEN TO <br />MIN POSITION. <br />SUPPLY FAN <br />SHALL <br />ENERGIZE AND <br />THE <br />UNIT SHALL <br />CYCLE COMPRESSOR <br />ON AS NEEDED <br />TO MAINTAIN <br />SPACE <br />TEMPERATURE <br />SET <br />POINT. <br />HEATING MODE: COMMAND FROM TEMP <br />SENSORS <br />(RTU-2 SET AT 687, ADJUSTABLE), <br />ADJUSTABLE <br />CALLS <br />FOR HEATING, <br />THE <br />OSA DAMPER <br />SHALL BE OPEN TO <br />MIN POSITION. <br />SUPPLY FAN <br />SHALL <br />ENERGIZE AND <br />THE <br />ELECTRIC STRIP <br />SHALL ENERGIZE <br />AS NEEDED TO <br />MAINTAIN SPACE <br />TEMPERATURE <br />SET <br />POINT. <br />UNOCCUPIED MODE <br />RTU SEQUENCE: <br />OSA DAMPER SHALL BE CLOSED, RETURN AIR DAMPER SHALL BE FULLY OPEN. RTU-1 AND <br />RTU-2 FANS WILL CYCLE ON AS NEEDED TO MAINTAIN AS NEEDED UNOCCUPIED SPACE <br />TEMP SET POINTS. THE UNIT WILL CYCLE HEAT OR CONDENSING UNIT AS NEEDED. <br />ECONOMIZER MODE (WHERE EXISTING UNITS HAVE AN ECONOMIZER). <br />OUTSIDE AIR CONDITIONS ARE 50 TO 60 DEGREE F (ADJUSTABLE) <br />RTU SEQUENCE: <br />COMMAND FROM TEMP SENSOR CALLS FOR COOLING, THE DIFFERENTIAL ENTHALPY SENSOR <br />INDICATES COOL DRY OUTSIDE AIR CONDITIONS / FREE COOLING IS AVAILABLE, THE OSA <br />DAMPER SHALL BE FULLY OPEN. SUPPLY FAN SHALL ENERGIZE TO MAINTAIN SPACE <br />TEMPERATURE SET POINT. HEATER AND COMPRESSORS ARE OFF. BASIS OF DESIGN IS A <br />LENNOX TYPE ECONOMIZER. <br />I MEP ROOF PLAN MISC. NOTES I <br />A. STRUCTURAL ENGINEERING IS BY OTHERS. <br />B. THE G.C. SHALL VERIFY EXACT W.I.C. AND W.I.F. SPECS WITH VENDOR AND ADJUST INSTALLATION <br />LOCATION AS NEEDED. VERIFY PRIOR TO PULLING WIRE. <br />O3 GAS PIPING TO COOKLINE, SEE GAS RISER, THIS SHEET FOR SIZING. <br />PROVIDE SOLENOID VALVE INTERLOCKED WITH HOOD CONTROLS TO <br />SHUT OFF GAS UPON SIGNAL FROM HOOD CONTROL CABINET. <br />O4 CONTRACTOR SHALL ENSURE THAT ALL FRESH AIR INTAKES ARE AT <br />LEAST 10'-0" AWAY FROM EXHAUST SOURCES (PLUMBING VENTS, <br />EXHAUST FANS, COMBUSTION EXHAUST, ETC.). CONTRACTOR SHALL <br />ENSURE THAT ALL NEW EXHAUST SOURCES ARE INSTALLED AT <br />LEAST 10'-0" FROM FROM FRESH AIR INTAKES OF ADJACENT UNITS. <br />PROVIDE OFFSETS AND ADJUST/RELOCATE EQUIPMENT AS NEEDED. <br />O TYPE 1 HOOD ABOVE COOKLINE, BELOW ROOF, MECHANICAL <br />CONTRACTOR SHALL INSTALL COMPLETE SYSTEM AS REQUIRED. PER <br />MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br />© INTERLOCK RTU-1 AND RTU-2 (FANS) WITH HOOD EXHAUST FANS <br />SO THAT WHEN THE HOOD IS IN USE THE EXHAUST FAN (EF-1) <br />AND RTUS OUTSIDE AIR/FANS WILL RUN TOGETHER. COMPRESSORS <br />WILL CYCLE AS NEEDED. <br />O VERIFY GAS PRESSURE SIZE AND PROVIDE PRESSURE REGULATOR IF <br />NECESSARY. LINE SIZES FROM SHELL DRAWINGS APPEAR TO BE <br />FOR LOW-PRESSURE GAS LESS THAN 2 PSI, VERIFY INLET <br />PRESSURE IN FIELD AND OUTLET PRESSURE WITH MANUFACTURER'S <br />REQUIREMENTS. ALL PIPING ON ROOF IS EXISTING TO REMAIN FOR <br />REUSE. GAS LOADS WILL NOT INCREASE ABOVE PREVIOUS TENANT'S <br />PEAK USAGE. <br />® CONDENSATE SHALL RUN FROM RTU TO APPROVED RECEPTOR BY <br />AHJ. ANY NEW CONDENSATE SHALL BE INSULATED WHERE WITHIN <br />THE BUILDING ENVELOPE. WHERE CONDENSATE DISCHARGE IS <br />EXISTING, LEAVE AS -IS. <br />O PROVIDE WINDBAND EXTENSION WITH GUY WIRES FOR EF-1 AS <br />NEEDED. ANY EXTENSION SHOULD BE HURRICANE -RATED. <br />COORDINATE WITH A STRUCTURAL ENGINEER AS REQUIRED. <br />w <br />0 <br />W <br />H <br />Q <br />J <br />Q <br />3 <br />OUTDOORS <br />WALMART STORE <br />MEP GAS & ROOF PLAN <br />SCALE: 1/4" = 1'-0" <br />StudioRG._ <br />MAIN OFFICE: <br />1 HUNTINGTON QUADRANGLE <br />SUITE 2CO3 <br />MELVILLE, NY 11747 <br />P: 631.226-7700 F:631.226.7175 <br />©Copyright 2018: RGBK, INC. <br />Land <br />_ GREG LAN DRY <br />ARCHU NE RANKING INTERIOR DESIGN <br />ry <br />1202 Richardsm Dr. #106 Tel 214.631.6941 <br />14chardson, Texas 75080 Fax:.214.634.1814 <br />Seal: <br />Pam. J" <br />a: <br />No 72679 •,, ` <br />:' <br />SfAY;- OF •� <br />N 1 <br />Owner: <br />George Morkos <br />2520 Colony Reed Lane <br />Clearwater, FL33763 <br />It is the responsibility of the Construction <br />Manager/General Contractor and all <br />Sub -Contractors to verify all dimensions and <br />accept conditions of prior work by related <br />trades before proceeding with any work. <br />Date <br />07-22-2020 <br />Drawn By Check By <br />MRP TN <br />Scale <br />AS SHOWN <br />Issued: <br />Project Title <br />Charleys <br />Zephyrhills <br />WM706 <br />Project Address <br />7631 Gall Blvd, <br />Zephyrhills, FL 33541 <br />Project Number <br />WM706 <br />Drawing Title and Number <br />MEP GAS & ROOF <br />PLAN <br />MEP1.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.