PLUMBING FIXTURE SCHEDULE <br />FIXTURE DATA <br />CONNECTION <br />DATA <br />EQUIP. & <br />MFG./ <br />0 <br />E <br />R <br />INDIRECT <br />WATER <br />GAS <br />REMARKS <br />ITEM ID <br />FIXTURES <br />MODEL # <br />I <br />N <br />A <br />WASTE <br />(MBH) <br />L <br />T <br />P <br />CW <br />HW <br />TW <br />TMV <br />THERMOSTATIC <br />WATTS/ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />THERMOSTATIC MIXING VALVE, MIN. TEMP 105- F. <br />MIXING VALVE <br />LFMMV <br />T.P. <br />TRAP PRIMER <br />JOSAM— <br />88250-10 <br />— <br />— <br />—�� <br />— <br />— <br />— <br />MOUNT UNDER CLOSEST SINK OR CLOSEST PIECE OF EQUIPMENT. <br />BFP1 <br />BACK FLOW <br />PREVENTER <br />WATTS/ SD-3 <br />— <br />— <br />— <br />— <br />— <br />— <br />— <br />— <br />DOUBLE CHECK VALVE ASSEMBLY <br />WCO <br />WALL <br />JOSAM/58600 <br />— <br />— <br />— <br />— <br />— <br />— <br />— <br />— <br />CLEANOUT <br />FCO <br />FLOOR <br />CLEANOUT <br />SIOUX CHIEF <br />834 SERIES <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />— <br />4" SQUARE FLOOR CLEANOUT. <br />S.A. <br />SHOCK ABSORBER <br />JOSAM / <br />— <br />— <br />— <br />— <br />— <br />PROVIDE ACCESS WALL PANEL. <br />FD <br />FLOOR DRAIN <br />ZURN <br />3" <br />1Y2" <br />3" <br />— <br />— <br />_ <br />_ <br />_ <br />ROUND 4" DRAIN, 5" DIAMETER WITH TRAP PRIMER CONNECTION, OR EQUAL. <br />GR—FR05N1— <br />PROVIDE TRAP GUARD. <br />C2N—PS—CC, <br />FS <br />FLOOR SINK <br />OATEY PVC <br />3" <br />1h" <br />3" <br />GRATE, SQUARE. USE IN LIGHT TRAFFIC AREAS. <br />FLOOR SINK <br />PROVIDED BY <br />PROVIDED BY KITCHEN SUPPLIER, INSTALLED BY TENANT'S PLUMBING <br />HS <br />HAND SINK <br />KITCHEN <br />2" <br />1kz" <br />1Ya" <br />— <br />Y2" <br />— <br />Yi" <br />— <br />CONTRACTOR. MIXING VALVES: POWERS #LM495-1; ASSE 1070, SET AT <br />SUPPLIER <br />1107. <br />PROVIDED BY <br />PROVIDED BY KITCHEN SUPPLIER, INSTALLED BY TENANT'S PLUMBING <br />3—COMP <br />3—COMP SINK <br />KITCHEN <br />2" <br />1" <br />1Ya" <br />— <br />Y2" <br />— <br />Y2" <br />— <br />CONTRACTOR, EXCEPT SANITIZE, REFURBISH, AND REUSE EXISTING IF <br />SUPPLIER <br />PRESENT. <br />MS <br />MOP SINK <br />FIAT MSB2424 <br />31 <br />1Y2" <br />3" <br />PROVIDE WITH FIAT 830—AA VACUUM RELIEF MOP FAUCET WITH WALL <br />HANGER, EXCEPT SANITIZE, REFURBISH, AND REUSE EXISTING IF PRESENT. <br />NOT ALL FIXTURES USED ON ALL JOBS. * THIS PROJECT <br />DOES NOT HAVE <br />A DISH <br />MACHINE.* <br />PLUMBING NOTES <br />A. HOT AND COLD WATER PIPING SHALL BE NEW UP TO THE CONNECTION TO THE EXISTING COLD WATER <br />MAIN LINE. <br />B. CONTRACTOR SHALL FURNISH AND INSTALL HANGER SUPPORTS AND ACCESSORIES REQUIRED FOR THE <br />PROPER INSTALLATION AND OPERATION OF THE PLUMBING SYSTEM AS REQUIRED BY CODE. <br />C. CONTRACTOR SHALL FURNISH AND INSTALL SHUT-OFF VALVES AT HOT AND COLD WATER CONNECTIONS. <br />D. THE CONTRACTOR SHALL COORDINATE ALL NEW WORK WITH EXISTING FIELD CONDITIONS AND ALL OTHER <br />TRADES INVOLVED. <br />E. HOT AND COLD WATER PIPING AND INSTALLATION SHALL COMPLY WITH LOCAL CODE REQUIREMENTS. <br />F. HOT AND COLD WATER PIPING AND INSTALLATION SHALL BE TESTED, INSPECTED AND APPROVED <br />BEFORE BEING COVERED AND CONCEALED AS REQUIRED. <br />G. CONTRACTOR SHALL FURNISH AND INSTALL THE NECESSARY FITTINGS FOR THE CONNECTION OF THE <br />NEW EQUIPMENT AND FIXTURES INCLUDING VACUUM BREAKERS AND BACK FLOW PREVENTERS AS <br />REQUIRED BY CODE. <br />H. COLD, HOT, AND TEMPERED WATER PIPING SHALL BE INSULATED. <br />I. CONDENSATE AND OVERFLOW PIPING SHALL BE INSULATED. <br />J. INTERIOR OR PERIMETER STRUCTURAL GRADE BEAMS MAY NOT BE CUT, IF PRESENT. <br />K. WATER LINES IN EXTERIOR BUILDING WALLS SHALL BE ON WARM (CONDITIONED) SIDE OF BUILDING <br />INSULATION. ALL PIPING SHALL BE CONCEALED FROM VIEW. <br />L. HEAT TRACE ALL PIPING IN EXTERIOR WALLS, AND AREAS SUBJECT TO FREEZING CONDITIONS. <br />M. FURR OUT WALLS FOR ELECTRICAL AND PLUMBING AS NEEDED, OR AS REQUIRED BY LANDLORD FOR <br />ELECTRICAL AND PLUMBING CONNECTIONS. <br />N. PROVIDE ADDITIONAL CUTOFFS ABOVE CEILING IF REQUIRED BY LOCAL CODE. <br />0. IF DESIGN CALLS FOR NEW FLOOR DRAIN IN A RESTROOM THAT IS EXISTING AND DOES NOT HAVE A <br />DRAIN AND IS NOT REQUIRED BY A.H.J. TO HAVE A FLOOR DRAIN, THEN THE PLUMBER CAN SKIP <br />INSTALLING IT IN THAT ROOM. <br />P. BASE BID TO ASSUME THAT THE JURISDICTION REQUIRES CONTAINMENT BACK FLOW PREVENTION. P.C. <br />SHALL CONFIRM WITH PLUMBING INSPECTOR IF BUILDING HAS MAIN RPZBFP AND DOES NOT REQUIRE <br />ADDITIONAL BFP IN SPACE, THE PLUMBER MAY OMIT BFP. IF JURISDICTION REQUIRES ISOLATION BFP, <br />THE PLUMBING CONTRACTOR SHALL OMIT THE RPZ BFP NEAR THE MOP SINK AND INSTEAD SHALL <br />PROVIDE A POINT OF USE BFP AT THE WATER BAR, AT THE DRINKING FOUNTAIN. AS APPLICABLE/AS <br />REQUIRED AND ELSEWHERE AS DETERMINED BY THE PLUMBING INSPECTOR. <br />Q. WHERE NEW BELOW SLAB PLUMBING MODIFICATIONS ARE PROPOSED, TENANT SHALL REPLACE ANY BASE <br />MATERIAL AND COMPACT TO MATCH EXISTING. MATCH FLOOR SLAB THICKNESS AND FINISH WITH 3,000 <br />PSI CONCRETE. - TENANT SHALL FIRST DO TEST DEMOLITION OF SLAB OF NO MORE THAN 5 SF TO <br />CONFIRM THAT THE EXISTING SLAB CONDITION IS NOT A STRUCTURAL SLAB. IF THE EXISTING SLAB <br />CONDITION IS A STRUCTURAL SLAB, TENANT SHALL IMMEDIATELY STOP UNDER SLAB WORK AND PROVIDE <br />SLAB PENETRATION/REMEDIATION DRAWINGS BY A LICENSED STRUCTURAL ENGINEER, LICENSED IN THE <br />STATE IN WHICH THE TENANT WORK IS TAKING PLACE. <br />R. CONTRACTOR TO USE LANDLORD/OWNER APPROVED ROOFING CONTRACTOR FOR ALL NEW TROUGH ROOF <br />PLUMBING VENT PENETRATIONS TO MAINTAIN ROOF WARRANTY. <br />S. ALL FLOOR SINKS, FLOOR DRAINS, FLOOR CLEANOUTS, AND GREASE TRAP (WHERE APPLICABLE) SHALL <br />BE INSTALLED SO THAT TOPS ARE FLUSH WITH FLOOR FINISH TILE. <br />T. CONTRACTOR TO COORDINATE / VERIFY EXACT LOCATIONS FOR ALL FLOOR FIXTURES PRIOR TO <br />SAW -CUTTING. <br />U. COORDINATE WATER LINES WITH ELECTRICAL CONTRACTOR. NEW WATER PIPING SHALL NOT BE ROUTED <br />OVER ELECTRICAL PANEL GEAR. <br />V. ALL BACKFLOW PREVENTERS SHOULD BE INSTALLED ABOVE THE KITCHEN DROP CEILING OR WITHIN <br />MILLWORK WHENEVER POSSIBLE OR COMPLETELY OUT OF CUSTOMER VIEW IN THE BACK OF THE <br />KITCHEN. BFP SHOULD REMAIN ACCESSIBLE, AS DEFINED BY LOCAL INSPECTOR (VERIFY BEFORE <br />INSTALLATION). BFP SHOULD NOT INTERFERE IN ANY WAY WITH THE OPERATION OF THE KITCHEN. IF <br />AN EXISTING BACKFLOW PREVENTER IS IN A LOCATION OTHER THAN WHAT IS SHOWN ON THESE <br />DRAWINGS, CONTACT THE ARCHITECT IMMEDIATELY FOR DIRECTION ON HOW TO PROCEED. <br />W. ALL PLUMBING AND GAS LINES MUST BE RECESSED WITHIN WALL CAVITIES, UNLESS SPECIFICALLY NOTED <br />OTHERWISE. <br />X. THE CONTRACTOR SHALL CONFIRM WASTE LINES FOUND IN FIELD AND SHALL VERIFY THAT THE <br />SANITARY WASTE LINES ARE CONNECTED TO BUILDING SANITARY WASTE LINE, AND NOT INTO A <br />BUILDING COMMON GREASE WASTE LINE. <br />Y. PROVIDE MINIMUM 6" AIR GAP AT DISCHARGE OF A T&P AT WATER HEATER. <br />Z. ALL PLUMBING SUPPLY LINES SHALL BE 1/2" UNLESS INDICATED OTHERWISE. <br />AA. ALL FIXTURES SHALL HAVE CLEANOUTS, WHETHER GRAPHICALLY INDICATED ON DRAWINGS OR NOT. <br />BB. PLUMBING CONTRACTOR SHALL MAKE ADJUSTMENTS WHERE NECESSARY TO KEEP PLUMBING VENTS A <br />MINIMUM OF 10'-0" AWAY FROM RTUS. WAIT FOR FINAL RTU LOCATIONS PRIOR TO CUTTING <br />ROOF PENETRATIONS. <br />CC. REUSE SUPPLY DROPS TO EXISTING FIXTURES WHERE POSSIBLE. PROVIDE NEW SUPPLY DROPS <br />DOWN TO NEW FIXTURES. <br />DD. REUSE WASTE CONNECTIONS SERVING EXISTING WASTE FIXTURES THAT ARE TO REMAIN FOR REUSE. <br />REWORK WASTE CONNECTIONS WHERE REQUIRED BY AHJ. PROVIDE NEW WASTE CONNECTIONS AT <br />NEW FIXTURES. <br />NOTES BY SYMBOL: <br />ZEPHYRHILLS, FL NOTE: <br />WATER, WASTE AND GAS POINTS <br />OF CONNECTION ARE ASSUMED <br />BASED ON TYPICAL WALMART <br />CONNECTIONS. GC SHALL VERIFY <br />ALL POINTS OF CONNECTION <br />AND MAKE ADJUSTMENTS AS <br />NEEDED. <br />Oj PROVIDE POINT OF USE RPZBFP, ROUTE DISCHARGE <br />THROUGH AIR GAP TO APPROVED RECEPTOR SUCH AS A <br />MOP SINK OR FLOOR SINK. MOUNT AT HEIGHT REQUIRED BY <br />A.H.J. FOR INSPECTION. <br />OFURROUT WALL AS NEEDED. VERIFY LANDLORD'S REQUIREMENTS <br />PRIOR TO ROUGH -IN. <br />OPOINT OF CONNECTION (DIAGRAMMATIC) TO EXISTING WATER MAIN IN <br />CEILING SPACE OR ELSEWHERE AS STUBBED IN. FROM POINT OF <br />CONNECTION, ROUTE NEW C.W. PIPING IN JOIST(S) SPACE. VERIFY <br />EXACT LOCATION AND SIZE OF EXISTING LINES IN FIELD. <br />OPROVIDE VACUUM RELIEF AT MOP SINK VIA NSF LISTED <br />ANTI -SIPHON FAUCET. <br />OGAS CONNECTION TO COOKING APPLIANCE. PROVIDE GAS COCK, <br />UNION AND DIRT LEG AT EACH PIECE OF EQUIPMENT. REFER TO <br />RISER DIAGRAM, THIS SHEET FOR PIPE SIZE. <br />O6 DO NOT ROUTE WATER LINES ABOVE PANELS OR ELECTRICAL GEAR. <br />PROVIDE WATER DIVERTING BARRIER OR SHIELD IF EXISTING LINES <br />TRAVERSE ABOVE GEAR LOCATION OR NEMA 3R PANEL AND <br />CONDUIT/FITTINGS. <br />OPROVIDE SHOCK ABSORBER ON ALL FAST -CLOSING VALVES [FLUSH <br />VALVES, 3-COMP SPRAYER (IF USED), ETC. AS APPLICABLE]. <br />OPROVIDE ASSE APPROVED THERMOSTATIC MIXING VALVE IF NOT <br />PRESENT AT ALL NEW LAVS AND HAND SINKS. SET TEMPERATURE <br />TO 105°F. <br />O1/2" UNDERGROUND TRAP PRIMER LINE TO NEW FLOOR DRAINS, <br />FLOOR SINKS, HUB DRAINS AND TRENCH DRAINS (AS NEEDED). <br />1-1/2" 140-F HW&CW <br />STUB —INS SERVING <br />CHARLEYS TENANT SPACE. <br />VERIFY EXACT LOCATION. <br />1 /2V)EX <br />P4E H S <br />1 /2'N <br />PLUMBING SUPPLY RISER l`o <br />SCALE: NOT TO SCALE <br />r/ <br />w <br />0 <br />En <br />ry <br />Q <br />3 <br />PLAN <br />NORTH <br />WALMART STORE <br />PLUMBING SUP <br />SCALE: 1 /4" = 1'-0" <br />PLY PLAN <br />Peter A. Leptuch, P.E. <br />300 N. Carroll Blvd. #20 <br />Denton, TX 76201 <br />(940) 735-5127 <br />' 140°F HW&CW <br />INS SERVING <br />EYS TENANT SPACE. <br />EXACT LOCATION. <br />Studio RG.,. <br />MAIN OFFICE: <br />1 HUNTINGTON QUADRANGLE <br />SUITE 2CO3 <br />MELVILLE, NY 11747 <br />P: 631.226-7700 F: 631.226.7175 <br />© Copyright 2018: RGBK, INC. <br />Seal: <br />Lan,dry <br />ARC]-IIIEOUK "NNING INTERIOR Dt?5GN <br />1202 Richardsm Dr. #106 Tel: 214.631.6941 <br />Rchardsan, Texas 75080 Fax: 214.634.1814 <br />4.S'61 <br />rU. <br />No 72679 <br />Owner: <br />George Morkos <br />2520 Colony Reed Lane <br />Clearwater, FL33763 <br />It is the responsibility of the Construction <br />Manager/General Contractor and all <br />Sub -Contractors to verify all dimensions and <br />accept conditions of prior work by related <br />trades before proceeding with any work. <br />Date <br />07-22-2020 <br />Drawn By Check By <br />MRP TN <br />Scale <br />AS SHOWN <br />Issued: <br />Project Title <br />Charleys <br />Zephyrhills <br />WM706 <br />Project Address <br />7631 Gall Blvd, <br />Zephyrhills, FL 33541 <br />Project Number <br />WM706 <br />Drawing Title and Number <br />PLUMBING SUPPLY <br />PLAN <br />P1.0 <br />