PLUMBING FIXTURE SCHEDULE
<br />FIXTURE DATA
<br />CONNECTION
<br />DATA
<br />EQUIP. &
<br />MFG./
<br />0
<br />E
<br />R
<br />INDIRECT
<br />WATER
<br />GAS
<br />REMARKS
<br />ITEM ID
<br />FIXTURES
<br />MODEL #
<br />I
<br />N
<br />A
<br />WASTE
<br />(MBH)
<br />L
<br />T
<br />P
<br />CW
<br />HW
<br />TW
<br />TMV
<br />THERMOSTATIC
<br />WATTS/
<br />_
<br />_
<br />_
<br />_
<br />_
<br />_
<br />_
<br />_
<br />THERMOSTATIC MIXING VALVE, MIN. TEMP 105- F.
<br />MIXING VALVE
<br />LFMMV
<br />T.P.
<br />TRAP PRIMER
<br />JOSAM—
<br />88250-10
<br />—
<br />—
<br />—��
<br />—
<br />—
<br />—
<br />MOUNT UNDER CLOSEST SINK OR CLOSEST PIECE OF EQUIPMENT.
<br />BFP1
<br />BACK FLOW
<br />PREVENTER
<br />WATTS/ SD-3
<br />—
<br />—
<br />—
<br />—
<br />—
<br />—
<br />—
<br />—
<br />DOUBLE CHECK VALVE ASSEMBLY
<br />WCO
<br />WALL
<br />JOSAM/58600
<br />—
<br />—
<br />—
<br />—
<br />—
<br />—
<br />—
<br />—
<br />CLEANOUT
<br />FCO
<br />FLOOR
<br />CLEANOUT
<br />SIOUX CHIEF
<br />834 SERIES
<br />_
<br />_
<br />_
<br />_
<br />_
<br />_
<br />_
<br />—
<br />4" SQUARE FLOOR CLEANOUT.
<br />S.A.
<br />SHOCK ABSORBER
<br />JOSAM /
<br />—
<br />—
<br />—
<br />—
<br />—
<br />PROVIDE ACCESS WALL PANEL.
<br />FD
<br />FLOOR DRAIN
<br />ZURN
<br />3"
<br />1Y2"
<br />3"
<br />—
<br />—
<br />_
<br />_
<br />_
<br />ROUND 4" DRAIN, 5" DIAMETER WITH TRAP PRIMER CONNECTION, OR EQUAL.
<br />GR—FR05N1—
<br />PROVIDE TRAP GUARD.
<br />C2N—PS—CC,
<br />FS
<br />FLOOR SINK
<br />OATEY PVC
<br />3"
<br />1h"
<br />3"
<br />GRATE, SQUARE. USE IN LIGHT TRAFFIC AREAS.
<br />FLOOR SINK
<br />PROVIDED BY
<br />PROVIDED BY KITCHEN SUPPLIER, INSTALLED BY TENANT'S PLUMBING
<br />HS
<br />HAND SINK
<br />KITCHEN
<br />2"
<br />1kz"
<br />1Ya"
<br />—
<br />Y2"
<br />—
<br />Yi"
<br />—
<br />CONTRACTOR. MIXING VALVES: POWERS #LM495-1; ASSE 1070, SET AT
<br />SUPPLIER
<br />1107.
<br />PROVIDED BY
<br />PROVIDED BY KITCHEN SUPPLIER, INSTALLED BY TENANT'S PLUMBING
<br />3—COMP
<br />3—COMP SINK
<br />KITCHEN
<br />2"
<br />1"
<br />1Ya"
<br />—
<br />Y2"
<br />—
<br />Y2"
<br />—
<br />CONTRACTOR, EXCEPT SANITIZE, REFURBISH, AND REUSE EXISTING IF
<br />SUPPLIER
<br />PRESENT.
<br />MS
<br />MOP SINK
<br />FIAT MSB2424
<br />31
<br />1Y2"
<br />3"
<br />PROVIDE WITH FIAT 830—AA VACUUM RELIEF MOP FAUCET WITH WALL
<br />HANGER, EXCEPT SANITIZE, REFURBISH, AND REUSE EXISTING IF PRESENT.
<br />NOT ALL FIXTURES USED ON ALL JOBS. * THIS PROJECT
<br />DOES NOT HAVE
<br />A DISH
<br />MACHINE.*
<br />PLUMBING NOTES
<br />A. HOT AND COLD WATER PIPING SHALL BE NEW UP TO THE CONNECTION TO THE EXISTING COLD WATER
<br />MAIN LINE.
<br />B. CONTRACTOR SHALL FURNISH AND INSTALL HANGER SUPPORTS AND ACCESSORIES REQUIRED FOR THE
<br />PROPER INSTALLATION AND OPERATION OF THE PLUMBING SYSTEM AS REQUIRED BY CODE.
<br />C. CONTRACTOR SHALL FURNISH AND INSTALL SHUT-OFF VALVES AT HOT AND COLD WATER CONNECTIONS.
<br />D. THE CONTRACTOR SHALL COORDINATE ALL NEW WORK WITH EXISTING FIELD CONDITIONS AND ALL OTHER
<br />TRADES INVOLVED.
<br />E. HOT AND COLD WATER PIPING AND INSTALLATION SHALL COMPLY WITH LOCAL CODE REQUIREMENTS.
<br />F. HOT AND COLD WATER PIPING AND INSTALLATION SHALL BE TESTED, INSPECTED AND APPROVED
<br />BEFORE BEING COVERED AND CONCEALED AS REQUIRED.
<br />G. CONTRACTOR SHALL FURNISH AND INSTALL THE NECESSARY FITTINGS FOR THE CONNECTION OF THE
<br />NEW EQUIPMENT AND FIXTURES INCLUDING VACUUM BREAKERS AND BACK FLOW PREVENTERS AS
<br />REQUIRED BY CODE.
<br />H. COLD, HOT, AND TEMPERED WATER PIPING SHALL BE INSULATED.
<br />I. CONDENSATE AND OVERFLOW PIPING SHALL BE INSULATED.
<br />J. INTERIOR OR PERIMETER STRUCTURAL GRADE BEAMS MAY NOT BE CUT, IF PRESENT.
<br />K. WATER LINES IN EXTERIOR BUILDING WALLS SHALL BE ON WARM (CONDITIONED) SIDE OF BUILDING
<br />INSULATION. ALL PIPING SHALL BE CONCEALED FROM VIEW.
<br />L. HEAT TRACE ALL PIPING IN EXTERIOR WALLS, AND AREAS SUBJECT TO FREEZING CONDITIONS.
<br />M. FURR OUT WALLS FOR ELECTRICAL AND PLUMBING AS NEEDED, OR AS REQUIRED BY LANDLORD FOR
<br />ELECTRICAL AND PLUMBING CONNECTIONS.
<br />N. PROVIDE ADDITIONAL CUTOFFS ABOVE CEILING IF REQUIRED BY LOCAL CODE.
<br />0. IF DESIGN CALLS FOR NEW FLOOR DRAIN IN A RESTROOM THAT IS EXISTING AND DOES NOT HAVE A
<br />DRAIN AND IS NOT REQUIRED BY A.H.J. TO HAVE A FLOOR DRAIN, THEN THE PLUMBER CAN SKIP
<br />INSTALLING IT IN THAT ROOM.
<br />P. BASE BID TO ASSUME THAT THE JURISDICTION REQUIRES CONTAINMENT BACK FLOW PREVENTION. P.C.
<br />SHALL CONFIRM WITH PLUMBING INSPECTOR IF BUILDING HAS MAIN RPZBFP AND DOES NOT REQUIRE
<br />ADDITIONAL BFP IN SPACE, THE PLUMBER MAY OMIT BFP. IF JURISDICTION REQUIRES ISOLATION BFP,
<br />THE PLUMBING CONTRACTOR SHALL OMIT THE RPZ BFP NEAR THE MOP SINK AND INSTEAD SHALL
<br />PROVIDE A POINT OF USE BFP AT THE WATER BAR, AT THE DRINKING FOUNTAIN. AS APPLICABLE/AS
<br />REQUIRED AND ELSEWHERE AS DETERMINED BY THE PLUMBING INSPECTOR.
<br />Q. WHERE NEW BELOW SLAB PLUMBING MODIFICATIONS ARE PROPOSED, TENANT SHALL REPLACE ANY BASE
<br />MATERIAL AND COMPACT TO MATCH EXISTING. MATCH FLOOR SLAB THICKNESS AND FINISH WITH 3,000
<br />PSI CONCRETE. - TENANT SHALL FIRST DO TEST DEMOLITION OF SLAB OF NO MORE THAN 5 SF TO
<br />CONFIRM THAT THE EXISTING SLAB CONDITION IS NOT A STRUCTURAL SLAB. IF THE EXISTING SLAB
<br />CONDITION IS A STRUCTURAL SLAB, TENANT SHALL IMMEDIATELY STOP UNDER SLAB WORK AND PROVIDE
<br />SLAB PENETRATION/REMEDIATION DRAWINGS BY A LICENSED STRUCTURAL ENGINEER, LICENSED IN THE
<br />STATE IN WHICH THE TENANT WORK IS TAKING PLACE.
<br />R. CONTRACTOR TO USE LANDLORD/OWNER APPROVED ROOFING CONTRACTOR FOR ALL NEW TROUGH ROOF
<br />PLUMBING VENT PENETRATIONS TO MAINTAIN ROOF WARRANTY.
<br />S. ALL FLOOR SINKS, FLOOR DRAINS, FLOOR CLEANOUTS, AND GREASE TRAP (WHERE APPLICABLE) SHALL
<br />BE INSTALLED SO THAT TOPS ARE FLUSH WITH FLOOR FINISH TILE.
<br />T. CONTRACTOR TO COORDINATE / VERIFY EXACT LOCATIONS FOR ALL FLOOR FIXTURES PRIOR TO
<br />SAW -CUTTING.
<br />U. COORDINATE WATER LINES WITH ELECTRICAL CONTRACTOR. NEW WATER PIPING SHALL NOT BE ROUTED
<br />OVER ELECTRICAL PANEL GEAR.
<br />V. ALL BACKFLOW PREVENTERS SHOULD BE INSTALLED ABOVE THE KITCHEN DROP CEILING OR WITHIN
<br />MILLWORK WHENEVER POSSIBLE OR COMPLETELY OUT OF CUSTOMER VIEW IN THE BACK OF THE
<br />KITCHEN. BFP SHOULD REMAIN ACCESSIBLE, AS DEFINED BY LOCAL INSPECTOR (VERIFY BEFORE
<br />INSTALLATION). BFP SHOULD NOT INTERFERE IN ANY WAY WITH THE OPERATION OF THE KITCHEN. IF
<br />AN EXISTING BACKFLOW PREVENTER IS IN A LOCATION OTHER THAN WHAT IS SHOWN ON THESE
<br />DRAWINGS, CONTACT THE ARCHITECT IMMEDIATELY FOR DIRECTION ON HOW TO PROCEED.
<br />W. ALL PLUMBING AND GAS LINES MUST BE RECESSED WITHIN WALL CAVITIES, UNLESS SPECIFICALLY NOTED
<br />OTHERWISE.
<br />X. THE CONTRACTOR SHALL CONFIRM WASTE LINES FOUND IN FIELD AND SHALL VERIFY THAT THE
<br />SANITARY WASTE LINES ARE CONNECTED TO BUILDING SANITARY WASTE LINE, AND NOT INTO A
<br />BUILDING COMMON GREASE WASTE LINE.
<br />Y. PROVIDE MINIMUM 6" AIR GAP AT DISCHARGE OF A T&P AT WATER HEATER.
<br />Z. ALL PLUMBING SUPPLY LINES SHALL BE 1/2" UNLESS INDICATED OTHERWISE.
<br />AA. ALL FIXTURES SHALL HAVE CLEANOUTS, WHETHER GRAPHICALLY INDICATED ON DRAWINGS OR NOT.
<br />BB. PLUMBING CONTRACTOR SHALL MAKE ADJUSTMENTS WHERE NECESSARY TO KEEP PLUMBING VENTS A
<br />MINIMUM OF 10'-0" AWAY FROM RTUS. WAIT FOR FINAL RTU LOCATIONS PRIOR TO CUTTING
<br />ROOF PENETRATIONS.
<br />CC. REUSE SUPPLY DROPS TO EXISTING FIXTURES WHERE POSSIBLE. PROVIDE NEW SUPPLY DROPS
<br />DOWN TO NEW FIXTURES.
<br />DD. REUSE WASTE CONNECTIONS SERVING EXISTING WASTE FIXTURES THAT ARE TO REMAIN FOR REUSE.
<br />REWORK WASTE CONNECTIONS WHERE REQUIRED BY AHJ. PROVIDE NEW WASTE CONNECTIONS AT
<br />NEW FIXTURES.
<br />NOTES BY SYMBOL:
<br />ZEPHYRHILLS, FL NOTE:
<br />WATER, WASTE AND GAS POINTS
<br />OF CONNECTION ARE ASSUMED
<br />BASED ON TYPICAL WALMART
<br />CONNECTIONS. GC SHALL VERIFY
<br />ALL POINTS OF CONNECTION
<br />AND MAKE ADJUSTMENTS AS
<br />NEEDED.
<br />Oj PROVIDE POINT OF USE RPZBFP, ROUTE DISCHARGE
<br />THROUGH AIR GAP TO APPROVED RECEPTOR SUCH AS A
<br />MOP SINK OR FLOOR SINK. MOUNT AT HEIGHT REQUIRED BY
<br />A.H.J. FOR INSPECTION.
<br />OFURROUT WALL AS NEEDED. VERIFY LANDLORD'S REQUIREMENTS
<br />PRIOR TO ROUGH -IN.
<br />OPOINT OF CONNECTION (DIAGRAMMATIC) TO EXISTING WATER MAIN IN
<br />CEILING SPACE OR ELSEWHERE AS STUBBED IN. FROM POINT OF
<br />CONNECTION, ROUTE NEW C.W. PIPING IN JOIST(S) SPACE. VERIFY
<br />EXACT LOCATION AND SIZE OF EXISTING LINES IN FIELD.
<br />OPROVIDE VACUUM RELIEF AT MOP SINK VIA NSF LISTED
<br />ANTI -SIPHON FAUCET.
<br />OGAS CONNECTION TO COOKING APPLIANCE. PROVIDE GAS COCK,
<br />UNION AND DIRT LEG AT EACH PIECE OF EQUIPMENT. REFER TO
<br />RISER DIAGRAM, THIS SHEET FOR PIPE SIZE.
<br />O6 DO NOT ROUTE WATER LINES ABOVE PANELS OR ELECTRICAL GEAR.
<br />PROVIDE WATER DIVERTING BARRIER OR SHIELD IF EXISTING LINES
<br />TRAVERSE ABOVE GEAR LOCATION OR NEMA 3R PANEL AND
<br />CONDUIT/FITTINGS.
<br />OPROVIDE SHOCK ABSORBER ON ALL FAST -CLOSING VALVES [FLUSH
<br />VALVES, 3-COMP SPRAYER (IF USED), ETC. AS APPLICABLE].
<br />OPROVIDE ASSE APPROVED THERMOSTATIC MIXING VALVE IF NOT
<br />PRESENT AT ALL NEW LAVS AND HAND SINKS. SET TEMPERATURE
<br />TO 105°F.
<br />O1/2" UNDERGROUND TRAP PRIMER LINE TO NEW FLOOR DRAINS,
<br />FLOOR SINKS, HUB DRAINS AND TRENCH DRAINS (AS NEEDED).
<br />1-1/2" 140-F HW&CW
<br />STUB —INS SERVING
<br />CHARLEYS TENANT SPACE.
<br />VERIFY EXACT LOCATION.
<br />1 /2V)EX
<br />P4E H S
<br />1 /2'N
<br />PLUMBING SUPPLY RISER l`o
<br />SCALE: NOT TO SCALE
<br />r/
<br />w
<br />0
<br />En
<br />ry
<br />Q
<br />3
<br />PLAN
<br />NORTH
<br />WALMART STORE
<br />PLUMBING SUP
<br />SCALE: 1 /4" = 1'-0"
<br />PLY PLAN
<br />Peter A. Leptuch, P.E.
<br />300 N. Carroll Blvd. #20
<br />Denton, TX 76201
<br />(940) 735-5127
<br />' 140°F HW&CW
<br />INS SERVING
<br />EYS TENANT SPACE.
<br />EXACT LOCATION.
<br />Studio RG.,.
<br />MAIN OFFICE:
<br />1 HUNTINGTON QUADRANGLE
<br />SUITE 2CO3
<br />MELVILLE, NY 11747
<br />P: 631.226-7700 F: 631.226.7175
<br />© Copyright 2018: RGBK, INC.
<br />Seal:
<br />Lan,dry
<br />ARC]-IIIEOUK "NNING INTERIOR Dt?5GN
<br />1202 Richardsm Dr. #106 Tel: 214.631.6941
<br />Rchardsan, Texas 75080 Fax: 214.634.1814
<br />4.S'61
<br />rU.
<br />No 72679
<br />Owner:
<br />George Morkos
<br />2520 Colony Reed Lane
<br />Clearwater, FL33763
<br />It is the responsibility of the Construction
<br />Manager/General Contractor and all
<br />Sub -Contractors to verify all dimensions and
<br />accept conditions of prior work by related
<br />trades before proceeding with any work.
<br />Date
<br />07-22-2020
<br />Drawn By Check By
<br />MRP TN
<br />Scale
<br />AS SHOWN
<br />Issued:
<br />Project Title
<br />Charleys
<br />Zephyrhills
<br />WM706
<br />Project Address
<br />7631 Gall Blvd,
<br />Zephyrhills, FL 33541
<br />Project Number
<br />WM706
<br />Drawing Title and Number
<br />PLUMBING SUPPLY
<br />PLAN
<br />P1.0