<br />GENERAL DEMOLITION NOTES
<br />❑A FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES IN WRITING PRIOR TO ONSET OF DEMOLITION.
<br />© DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH THE LOCAL BUILDING CODE AND LANDLORD'S STANDARD PROCEDURES.
<br />© EXERCISE EXTREME CAUTION IN DEMOLITION, COST OF REPAIR TO ANY ADJACENT CONDITIONS DAMAGED AS A RESULT OF THIS DEMOLITION
<br />SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
<br />a ALL MATERIAL TO BE DISPOSED OF IS TO BE DONE BY THE CONTRACTOR OFF THE PROJECT SITE IN ACCORDANCE WITH L.L. REQUIREMENTS &
<br />LOCAL RESTRICTIONS UNLESS OTHERWISE NOTED HEREIN.
<br />❑E ALL AREAS SHALL BE KEPT IN A BROOM CLEAN CONDITION AT ALL TIMES.
<br />FTJ IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREIN OR NOT, AND TO
<br />PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL THE EXPENSES OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER
<br />PROPERTY DAMAGE BY OPERATIONS IN CONNECTION WITH EXECUTION OF THE WORK. INACTIVE OR ABANDONED UTILITIES SHALL BE CAPPED
<br />IN ACCORDANCE WITH LOCAL RESTRICTIONS, REMOVE INACTIVE SERVICES (PLUMBING, ELECTRICAL, MECHANICAL, ETC.) AS REQUIRED TO
<br />MAINTAIN OPERATION.
<br />© MAINTAIN COMPLETE SECURITY OF THE JOB SITE WHILE JOB IS IN PROGRESS AND UNTIL JOB IS COMPLETE,
<br />OH PROTECT ALL STRUCTURAL MEMBERS FROM DAMAGE, AND BRACE ALL EXISTING STRUCTURES AS NEEDED DURING THE DEMOLITION.
<br />�I DO NOT CUT ON EXISTING STRUCTURAL WORK IN A MANNER RESULTING IN A REDUCTION OF LOAD CARRYING CAPACITY OR LOAD/DEFLECTION
<br />RATIO. NOTIFY LANDLORD REP. OF ALL STRUCTURAL PROPOSED CUTS PRIOR TO EXECUTION TO OBTAIN APPROVAL.
<br />�J IN ALL AREAS WHERE DEMOLITION CAUSES UNEVENNESS IN THE FLOOR SLAB, PERFORM THE NECESSARY WORK REQUIRED TO PROVIDE A
<br />SMOOTH SLAB PREPARED TO RECEIVE NEW FINISHES.
<br />❑K ANY EXISTING TO REMAIN FIRE ASSEMBLIES DAMAGED DURING DEMOLITION SHALL BE REPAIRED TO MEET ORIGINAL FIRE PROTECTION
<br />REQUIREMENT.
<br />© IT WILL BE THE GENERAL CONTRACTORS RESPONSIBILITY TO COORDINATE WITH LANDLORD ON -SITE OPERATIONS DIRECTOR AND TENANT
<br />BELOW, BEFORE BELOW SLAB WORK IS TO BE DONE.
<br />FM-] IT WILL BE THE GENERAL CONTRACTORS RESPONSIBILITY TO COORDINATE ANY WORK ON THE FIRE SUPRESSION, FIRE ALARM, OR SAFETY
<br />SYSTEM WITH OWNER AND WALMART. SPRINKLER, STRUCTURAL, FIRES ALARM, AND FIRE SUPPRESSION DRAWINGS BY OTHERS
<br />DEMOLITION NOTES
<br />F11u GENERAL CONTRACTOR SHALL REMOVE EXISTING NONBEARING PARTITION WALLS AS INDICATED, DISCONNECT AND REMOVE ALL EXISTING
<br />ELECTRIC, CAP OFF PLUMBING (IF ANY) WITHIN REMAINING WALLS OR ABOVE CEILING, AS REQUIRED. PATCH AND REPAIR REMAINING WALL,
<br />CEILING, AND FLOOR SURFACES TO ACCEPT FINISHES AS INDICATED.
<br />1A GENERAL CONTRACTOR SHALL REMOVE PORTION OF EXISTING INTERIOR LOW WALL. THE REMAINING OF THE EXISTING LOW WALL SHALL
<br />REMAIN, SEE FLOOR PLAN
<br />U GENERAL CONTRACTOR SHALL REMOVE EXISTING TILE FLOOR FINISHES IN DINING ROOM AND RESTROOMS, CLEAN AND REPAIR EXISTING
<br />CONC. SLAB TO RECEIVE NEW FINISHES PER FLOOR FINISHES PLAN.
<br />® GENERAL CONTRACTOR SHALL VERIFY CONDITION OF EXISTING QUARRY TILE FLOORING IN KITCHEN AND PREP AREA TO BE REUSED, INSTALL
<br />NEW QUARRY TILE AS REQUIRED, SEE FLOOR FINISH PLAN.
<br />u GENERAL CONTRACTOR SHALL REMOVE EXISTING CEILING LIGHT FIXTURES AND FANS IN DINING ROOM, SEE REFLECTED CEILING PLAN FOR
<br />NEW CEILING AND LIGHTING CONFIGURATION.
<br />3A GENERAL CONTRACTOR SHALL VERIFY CONDITION OF EXISTING SUSPENDED CEILING TILE/ LIGHT FIXTURES IN KITCHEN AREA. REPLACE AS
<br />REQUIRED.
<br />F41U EXISTING A/C UNIT TO REMAIN, REUSE EXISTING DUCTWORK, SEE SHEET M1.0 FOR MODIFICATION TO EXISTING HVAC SYSTEM.
<br />5❑ EXISTING SERVICE DOOR TO REMAIN.
<br />F61 EXISTING STOREFRONT GLASS WINDOWS AND DOORS TO REMAIN.
<br />6A REMOVE EXISTING STOREFRONT METAL AWNING FRAME.
<br />® EXISTING ELECTRICAL POWER SUPPLY TO REMAIN, SEE ELECTRICAL DRAWING.
<br />L� EXISTING RESTROOM DOORS TO REMAIN, SEE DOOR SCHEDULE FOR FINISHES.
<br />10 REMOVE EXISTING DINING ROOM FIXTURES, SALES COUNTER, MILWORK AND METAL POLES.
<br />1111 EXISTING MOP SINK TO REMAIN, RESTORE TO LIKE NEW CONDITION. SEE PLUMBING DRAWING.
<br />[121 REMOVE HAND SINK PLUMBING PIPING AND FURRED WALL.
<br />13 VERIFY CONDITION OF ALL WALL FINISHES FRP IN KITCHEN, COORDINATE WITH OWNER FOR REPLACING FRP WITH NEW.
<br />[141 COORDINATE WITH OWNER AND REMOVE EXISTING HOOD, DUCT WORK AND ROOF FANS.
<br />15 REMOVE DINING ROOM TILE FINISHES. INSTALL NEW FINISHES PER INTERIOR ELEVATIONS.
<br />16 REMOVE PREP AREA TILE FINISHES. INSTALL NEW FINISHES PER INTERIOR ELEVATIONS.
<br />16 EXISTING WALL BRICK FINISH TO REMAIN, RESTORE BRICK TO LIKE NEW CONDITION.
<br />[171 COORDINATE WITH OWNER AND REMOVE EXISTING CO2 TANK.
<br />[181 REMOVE PORTION OF EXISTING SOFFIT, SEE REFLECTED CEILING PLAN FOR NEW SOFFIT CONFIGURATION.
<br />[191 EXISTING FLOOR RECESSED GREASE INTERCEPTOR TO REMAIN, VERIFY CONDITION AND CODE COMPLIANCE. RESTORE TO LIKE NEW
<br />CONDITION.
<br />[201 EXISTING WATER HEATER TO BE REMOVED, INSTALL NEW GAS WATER HEATER PER PLUMBING PLANS.
<br />WALMART DEMOLITION NOTES
<br />1. TENANT PROPOSES BELOW SLAB PLUMBING WORK. TENANT
<br />SHALL REPLACE ANY BASE MATERIAL AND COMPACT TO
<br />MATCH EXISTING. MATCH FLOOR SLAB THICKNESS AND FINISH
<br />WITH 4,000 PSI CONCRETE. REF STRUCT. -- TENANT SHALL
<br />FIRST DO TEST DEMOLITION OF SLAB OF NO MORE THAN 5SF
<br />TO CONFIRM THAT THE EXISTING SLAB CONDITION IS NOT A
<br />STRUCTURAL SLAB. IF THE EXISTING SLAB CONDITION IS A
<br />STRUCTURAL SLAB TENANT SHALL IMMEDIATELY STOP
<br />UNDERSLAB WORK AND PROVIDE SLAB
<br />PENETRATION/REMEDIATION DRAWINGS TO WALMART BY A
<br />LICENSENED STRUCTURAL ENGINEER, LICENSED IN THE STATE
<br />IN WHICH THE TENANT WORK IS TAKING PLACE.
<br />2. NO ROOF STRUCTURAL MEMBERS SHALL BE REMOVED OR
<br />DAMAGED DURING THE TENANT SPACE DEMOLITION.
<br />Demolitic
<br />SCALE: 1/4" = V-0"
<br />Demolition Ceiling Plan
<br />SCALE: 1/4" = V-0"
<br />BE
<br />IOOD
<br />0 BE
<br />TO
<br />0
<br />StudioRG_
<br />MAIN OFFICE:
<br />1 HUNTINGTON QUADRANGLE
<br />SUITE 2CO3
<br />MELVILLE, NY 11747
<br />P:631.226-7700 F:631.226.7175
<br />0 Copyright 2018: RGBK, INC.
<br />Landry
<br />GREG LANDRY
<br />ARCHITECTURE PIANNING INTERIOR DESIGN
<br />1202 Richardson Dr. #106 Tel: 214,631.6941
<br />Richardson, Texas 75080 Fax: 214.634.1814
<br />Seal:
<br />Gregory
<br />G.
<br />'(�•O F• F� ��
<br />G Landry
<br />AR95731 C~i
<br />Digitally signed
<br />E' by Gregory G
<br />Landry
<br />6/ 112 I Date: 2021.06.01
<br />Architects. Cert. No. AR95731
<br />Expiration Date: 2.28.23 11:41:01-05'00'
<br />Owner:
<br />Charley's Steakery Inc.
<br />ATTN: Amgad Attalla
<br />2952 Carrickton Cir.
<br />Orlando, FL 32824
<br />(201) 668-6672
<br />It is the responsibility of the Construction
<br />Manager/General Contractor and all
<br />Sub -Contractors to verify all dimensions and
<br />accept conditions of prior work by related
<br />trades before proceeding with any work.
<br />Date
<br />07-22-2020
<br />Drawn By Check By
<br />MRP TN
<br />Scale
<br />AS SHOWN
<br />Issued:
<br />Project Title
<br />Charleys
<br />Zephyrhills, FL
<br />WM706
<br />Project Address
<br />7631 Gall Blvd,
<br />Zephyrhills, FL 33541
<br />Project Number
<br />WM706
<br />Drawing Title and Number
<br />DEMOLITION PLANS
<br />A0.4
<br />
|