W?-Ilfn i <br />GENERAL DEMOLITION NOTES <br />❑A FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES IN WRITING PRIOR TO ONSET OF DEMOLITION. <br />© DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH THE LOCAL BUILDING CODE AND LANDLORD'S STANDARD PROCEDURES. <br />© EXERCISE EXTREME CAUTION IN DEMOLITION, COST OF REPAIR TO ANY ADJACENT CONDITIONS DAMAGED AS A RESULT OF THIS DEMOLITION <br />SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. <br />a ALL MATERIAL TO BE DISPOSED OF IS TO BE DONE BY THE CONTRACTOR OFF THE PROJECT SITE IN ACCORDANCE WITH L.L. REQUIREMENTS & <br />LOCAL RESTRICTIONS UNLESS OTHERWISE NOTED HEREIN. <br />❑E ALL AREAS SHALL BE KEPT IN A BROOM CLEAN CONDITION AT ALL TIMES. <br />FTJ IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREIN OR NOT, AND TO <br />PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL THE EXPENSES OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER <br />PROPERTY DAMAGE BY OPERATIONS IN CONNECTION WITH EXECUTION OF THE WORK. INACTIVE OR ABANDONED UTILITIES SHALL BE CAPPED <br />IN ACCORDANCE WITH LOCAL RESTRICTIONS, REMOVE INACTIVE SERVICES (PLUMBING, ELECTRICAL, MECHANICAL, ETC.) AS REQUIRED TO <br />MAINTAIN OPERATION. <br />© MAINTAIN COMPLETE SECURITY OF THE JOB SITE WHILE JOB IS IN PROGRESS AND UNTIL JOB IS COMPLETE, <br />OH PROTECT ALL STRUCTURAL MEMBERS FROM DAMAGE, AND BRACE ALL EXISTING STRUCTURES AS NEEDED DURING THE DEMOLITION. <br />�I DO NOT CUT ON EXISTING STRUCTURAL WORK IN A MANNER RESULTING IN A REDUCTION OF LOAD CARRYING CAPACITY OR LOAD/DEFLECTION <br />RATIO. NOTIFY LANDLORD REP. OF ALL STRUCTURAL PROPOSED CUTS PRIOR TO EXECUTION TO OBTAIN APPROVAL. <br />�J IN ALL AREAS WHERE DEMOLITION CAUSES UNEVENNESS IN THE FLOOR SLAB, PERFORM THE NECESSARY WORK REQUIRED TO PROVIDE A <br />SMOOTH SLAB PREPARED TO RECEIVE NEW FINISHES. <br />❑K ANY EXISTING TO REMAIN FIRE ASSEMBLIES DAMAGED DURING DEMOLITION SHALL BE REPAIRED TO MEET ORIGINAL FIRE PROTECTION <br />REQUIREMENT. <br />© IT WILL BE THE GENERAL CONTRACTORS RESPONSIBILITY TO COORDINATE WITH LANDLORD ON -SITE OPERATIONS DIRECTOR AND TENANT <br />BELOW, BEFORE BELOW SLAB WORK IS TO BE DONE. <br />FM-] IT WILL BE THE GENERAL CONTRACTORS RESPONSIBILITY TO COORDINATE ANY WORK ON THE FIRE SUPRESSION, FIRE ALARM, OR SAFETY <br />SYSTEM WITH OWNER AND WALMART. SPRINKLER, STRUCTURAL, FIRES ALARM, AND FIRE SUPPRESSION DRAWINGS BY OTHERS <br />DEMOLITION NOTES <br />F11u GENERAL CONTRACTOR SHALL REMOVE EXISTING NONBEARING PARTITION WALLS AS INDICATED, DISCONNECT AND REMOVE ALL EXISTING <br />ELECTRIC, CAP OFF PLUMBING (IF ANY) WITHIN REMAINING WALLS OR ABOVE CEILING, AS REQUIRED. PATCH AND REPAIR REMAINING WALL, <br />CEILING, AND FLOOR SURFACES TO ACCEPT FINISHES AS INDICATED. <br />1A GENERAL CONTRACTOR SHALL REMOVE PORTION OF EXISTING INTERIOR LOW WALL. THE REMAINING OF THE EXISTING LOW WALL SHALL <br />REMAIN, SEE FLOOR PLAN <br />U GENERAL CONTRACTOR SHALL REMOVE EXISTING TILE FLOOR FINISHES IN DINING ROOM AND RESTROOMS, CLEAN AND REPAIR EXISTING <br />CONC. SLAB TO RECEIVE NEW FINISHES PER FLOOR FINISHES PLAN. <br />® GENERAL CONTRACTOR SHALL VERIFY CONDITION OF EXISTING QUARRY TILE FLOORING IN KITCHEN AND PREP AREA TO BE REUSED, INSTALL <br />NEW QUARRY TILE AS REQUIRED, SEE FLOOR FINISH PLAN. <br />u GENERAL CONTRACTOR SHALL REMOVE EXISTING CEILING LIGHT FIXTURES AND FANS IN DINING ROOM, SEE REFLECTED CEILING PLAN FOR <br />NEW CEILING AND LIGHTING CONFIGURATION. <br />3A GENERAL CONTRACTOR SHALL VERIFY CONDITION OF EXISTING SUSPENDED CEILING TILE/ LIGHT FIXTURES IN KITCHEN AREA. REPLACE AS <br />REQUIRED. <br />F41U EXISTING A/C UNIT TO REMAIN, REUSE EXISTING DUCTWORK, SEE SHEET M1.0 FOR MODIFICATION TO EXISTING HVAC SYSTEM. <br />5❑ EXISTING SERVICE DOOR TO REMAIN. <br />F61 EXISTING STOREFRONT GLASS WINDOWS AND DOORS TO REMAIN. <br />6A REMOVE EXISTING STOREFRONT METAL AWNING FRAME. <br />® EXISTING ELECTRICAL POWER SUPPLY TO REMAIN, SEE ELECTRICAL DRAWING. <br />L� EXISTING RESTROOM DOORS TO REMAIN, SEE DOOR SCHEDULE FOR FINISHES. <br />10 REMOVE EXISTING DINING ROOM FIXTURES, SALES COUNTER, MILWORK AND METAL POLES. <br />1111 EXISTING MOP SINK TO REMAIN, RESTORE TO LIKE NEW CONDITION. SEE PLUMBING DRAWING. <br />[121 REMOVE HAND SINK PLUMBING PIPING AND FURRED WALL. <br />13 VERIFY CONDITION OF ALL WALL FINISHES FRP IN KITCHEN, COORDINATE WITH OWNER FOR REPLACING FRP WITH NEW. <br />[141 COORDINATE WITH OWNER AND REMOVE EXISTING HOOD, DUCT WORK AND ROOF FANS. <br />15 REMOVE DINING ROOM TILE FINISHES. INSTALL NEW FINISHES PER INTERIOR ELEVATIONS. <br />16 REMOVE PREP AREA TILE FINISHES. INSTALL NEW FINISHES PER INTERIOR ELEVATIONS. <br />16 EXISTING WALL BRICK FINISH TO REMAIN, RESTORE BRICK TO LIKE NEW CONDITION. <br />[171 COORDINATE WITH OWNER AND REMOVE EXISTING CO2 TANK. <br />[181 REMOVE PORTION OF EXISTING SOFFIT, SEE REFLECTED CEILING PLAN FOR NEW SOFFIT CONFIGURATION. <br />[191 EXISTING FLOOR RECESSED GREASE INTERCEPTOR TO REMAIN, VERIFY CONDITION AND CODE COMPLIANCE. RESTORE TO LIKE NEW <br />CONDITION. <br />[201 EXISTING WATER HEATER TO BE REMOVED, INSTALL NEW GAS WATER HEATER PER PLUMBING PLANS. <br />WALMART DEMOLITION NOTES <br />1. TENANT PROPOSES BELOW SLAB PLUMBING WORK. TENANT <br />SHALL REPLACE ANY BASE MATERIAL AND COMPACT TO <br />MATCH EXISTING. MATCH FLOOR SLAB THICKNESS AND FINISH <br />WITH 4,000 PSI CONCRETE. REF STRUCT. -- TENANT SHALL <br />FIRST DO TEST DEMOLITION OF SLAB OF NO MORE THAN 5SF <br />TO CONFIRM THAT THE EXISTING SLAB CONDITION IS NOT A <br />STRUCTURAL SLAB. IF THE EXISTING SLAB CONDITION IS A <br />STRUCTURAL SLAB TENANT SHALL IMMEDIATELY STOP <br />UNDERSLAB WORK AND PROVIDE SLAB <br />PENETRATION/REMEDIATION DRAWINGS TO WALMART BY A <br />LICENSENED STRUCTURAL ENGINEER, LICENSED IN THE STATE <br />IN WHICH THE TENANT WORK IS TAKING PLACE. <br />2. NO ROOF STRUCTURAL MEMBERS SHALL BE REMOVED OR <br />DAMAGED DURING THE TENANT SPACE DEMOLITION. <br />Demolitic <br />SCALE: 1/4" = V-0" <br />Demolition Ceiling Plan <br />SCALE: 1/4" = V-0" <br />BE <br />IOOD <br />0 BE <br />TO <br />0 <br />StudioRG_ <br />MAIN OFFICE: <br />1 HUNTINGTON QUADRANGLE <br />SUITE 2CO3 <br />MELVILLE, NY 11747 <br />P:631.226-7700 F:631.226.7175 <br />0 Copyright 2018: RGBK, INC. <br />Landry <br />GREG LANDRY <br />ARCHITECTURE PIANNING INTERIOR DESIGN <br />1202 Richardson Dr. #106 Tel: 214,631.6941 <br />Richardson, Texas 75080 Fax: 214.634.1814 <br />Seal: <br />Gregory <br />G. <br />'(�•O F• F� �� <br />G Landry <br />AR95731 C~i <br />Digitally signed <br />E' by Gregory G <br />Landry <br />6/ 112 I Date: 2021.06.01 <br />Architects. Cert. No. AR95731 <br />Expiration Date: 2.28.23 11:41:01-05'00' <br />Owner: <br />Charley's Steakery Inc. <br />ATTN: Amgad Attalla <br />2952 Carrickton Cir. <br />Orlando, FL 32824 <br />(201) 668-6672 <br />It is the responsibility of the Construction <br />Manager/General Contractor and all <br />Sub -Contractors to verify all dimensions and <br />accept conditions of prior work by related <br />trades before proceeding with any work. <br />Date <br />07-22-2020 <br />Drawn By Check By <br />MRP TN <br />Scale <br />AS SHOWN <br />Issued: <br />Project Title <br />Charleys <br />Zephyrhills, FL <br />WM706 <br />Project Address <br />7631 Gall Blvd, <br />Zephyrhills, FL 33541 <br />Project Number <br />WM706 <br />Drawing Title and Number <br />DEMOLITION PLANS <br />A0.4 <br />