Laserfiche WebLink
1" TEE WITH PLUG <br />FIRE PROTECTION CONTRACTOR <br />SHALL INSTALL PIPE THROUGH <br />HOLE RESERVED FOR <br />SPRINKLER INSTALLATION. <br />NOTE TO CONTRACTOR: <br />PROVIDE A SIGN WITH THE <br />FOLLOWING STATEMENT AND <br />ATTACH TO THE TOP OF THE <br />AUTOMATED EQUIPMENT. <br />"FLEXIBLE DROP IS <br />PRESSURIZED. PRIOR TO <br />REMOVING FIRE SPRINKLER <br />DRAIN FIRE PROTECTION <br />SYSTEM AND 1" DROP" <br />L L = W/4, 4" MIN <br />NOTES: <br />1. SPIN -IN FITTINGS W/ SCOOPS ARE NOT <br />ACCEPTABLE. <br />2. REF PLANS FOR RUNOUT SIZES. <br />3. 450 LEAD IN. <br />SELF TAPPING <br />SCREWS <br />BRANCH DUCT FITTING <br />12" = 1'-0" <br />SUPPLY FROM WET <br />PIPE SPRINKLER SYSTEM INSTITUTIONAL MODEL <br />FLEXIBLE SPRINKLER DROP <br />CORRUGATED STAINLESS <br />STEEL HOSE WITH STAINLESS <br />STEEL BRAID 4' LENGTH. <br />WALL PLATE <br />DO NOT ATTACH TO UNIT <br />ADJUSTABLE HUB MULTI -PORT BRACKET INSTALL AS LOW AS <br />POSSIBLE INSTALL AS LOW AS POSSIBLE <br />METAL STUD E). APPROPRIATE <br />RIGID SURFACE). <br />I <br />IS <br />1" <br />PENDENT SPRINKLER <br />NO ESCUTHEON <br />REQUIRED <br />PHARMACY CEILING <br />3" <br />LOADS MUST BE HUNG <br />WITHIN 3" OF PANEL <br />POINTS OF EXISTING <br />STRUCTURAL JOISTS - <br />TOP BEAM <br />CLAMP TYP <br />TOP CHORD OF JOIST <br />ROOF <br />THREADED ROD <br />TYP <br />RECTANGULAR DUCT -J �-2"x2"x1/4" ANGLE <br />BOTTOM OF OR 1 5/8"x1 5/8" <br />STRUCTURE RECTANGULAR DUCT UNISTRUT <br />PERPENDICULAR TO STRUCTURE <br />OPTIONAL ROUTING IN <br />CONCEALED AREAS -1 <br />HEALTH SERVICES <br />CEILING DIFFUSER -- <br />SUPPLIED AND INSTALLED <br />BY PANEL MANUFACTURER <br />12"x12" FACE SIZE <br />8" ROUND NECK <br />SIMILAR TO TITUS TDC <br />150 CFM <br />FINAL DUCTWORK CONNECTION <br />TO PRE -INSTALLED DIFFUSER <br />BY GENERAL CONTRACTOR <br />SPRINKLER HEAD SUPPLIED <br />AND INSTALLED BY PANEL <br />MANUFACTURER <br />CEILING RETURN GRILLE - <br />SUPPLIED AND INSTALLED <br />BY PANEL MANUFACTURER <br />12"x12" FACE SIZE <br />8" ROUND NECK <br />SIMILAR TO TITUS 50F <br />150 CFM <br />BOTTOM OF <br />STRUCTURE <br />TWIST STRAP <br />16 GAUGE GALV STEEL <br />BAND (2" WIDE) <br />ROUND DUCT <br />3" <br />LOADS MUST BE HUN <br />WITHIN 3" OF PANEL <br />POINTS OF EXISTING <br />STRUCTURAL JOISTS <br />ROUND SUPPLY <br />AIR DUCT <br />450 LOAD RATED <br />FASTENERS <br />ROOF <br />2"x7x1/4" ANGLE <br />OR 1 5/8"x1 5/8" <br />6" UNISTRUT <br />lo <br />HANGER STRAP - <br />1" MIN. <br />60" MAX. <br />L•J <br />SHEET METAL <br />SCREWS TYP <br />RECTANGULAR DUCT <br />PARALLEL TO STRUCTURE <br />LOAD RATED <br />FASTENERS <br />ROOF <br />L-9 <br />ANGLE OR <br />1 5/8"x1 5/8" UNISTRUT <br />DUCT SUPPORT BAND <br />SAME SIZE AS STRAP <br />a2"x2"x1/4" <br />010 <br />0� <br />�6° <br />45° <br />SUPPLY REGISTER, REF FLOOR PLAN FOR SIZE AND <br />LOCATION, MOUNT REGISTERS @ 30 DEGREE ANGLE <br />DOWN FROM HORIZONTAL IN STOCKROOM AREA AND <br />@ 15 DEGREE ANGLE DOWN FROM HORIZONTAL IN <br />SALES AREA, EXCEPT THOSE SHOWN ON BOTTOM OF <br />DUCT ON THE PLAN <br />PERPENDICULAR TO JOIST <br />PARALLEL TO JOIST <br />DUCT SUPPORT AND GRILLE <br />12" = V-0" <br />INSTALL DAMPER IN VERTICAL <br />AT 24" MAX ABOVE CEILING <br />BALANCE TO 930 CFM _ <br />REMOVE DIFFUSER <br />AND PORTION OF <br />EXISTING DUCTWORK <br />SHOWN DASHED <br />RTU <br />ETR <br />GENERAL NOTES <br />1. THE DESIGN SHOWN ON THESE CONTRACT <br />DOCUMENTS HAS BEEN PREPARED FOR APPROVAL <br />BY THE AUTHORITY HAVING JURISDICTION AND TO <br />PROVIDE GUIDANCE FOR BIDDING. SUBMIT <br />COMPLETE FIRE SPRINKLER SHOP DRAWINGS AS <br />REQUIRED BY CONTRACT DOCUMENTS TO THE <br />OWNERS DESIGNATED REVIEWERS. BASE <br />SPRINKLER DESIGN UPON THESE DRAWINGS AND <br />AS REQUIRED BY THE SPECIFICATIONS. SHOP <br />DRAWINGS MUST INCLUDE ELEVATIONS, HANGER <br />LOCATIONS, PIPE LENGTHS, DIMENSIONS, <br />FABRICATIONS METHODS, MATERIAL DATA, AND <br />ADDITIONAL INFORMATION NECESSARY TO CLARIFY <br />THE INTENT OF INSTALLATION. CONTRACTOR SHALL <br />PROVIDE PIPE SIZE, SPRINKLER SPACING, AND <br />SYSTEM CONFIGURATION AS SHOWN. ALTERNATE <br />MATERIALS MUST BE SENT TO THE FIRE <br />PROTECTION ENGINEER OF RECORD OR VIA THE RFI <br />PROCESS AND MUST BE APPROVED IN RECORD <br />DOCUMENTS PRIOR TO BID. <br />2. COORDINATE LOCATIONS OF FIRE PROTECTION <br />COMPONENTS, INCLUDING PIPING, ALARMS, DRAINS, <br />TEST POINTS, ETC. WITH ARCHITECTURAL, <br />STRUCTURAL, MECHANICAL, AND ELECTRICAL <br />COMPONENTS. OBSTRUCTION TO SPRINKLER <br />DISCHARGE MUST BE CONSIDERED DURING SHOP <br />DRAWING PRODUCTION AND INSTALLATION; <br />ADDITIONAL SPRINKLERS MAY BE REQUIRED AT NO <br />ADDITIONAL COST TO OWNER. REFER TO <br />SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. <br />3. CONTRACTOR MUST VISIT THE BUILDING SITE TO <br />DETERMINE THE FULL EXTENT OF THE EXISTING <br />FIRE PROTECTION WORK AND EXISTING <br />CONDITIONS, BECOME TOTALLY FAMILIAR WITH THE <br />DISCONNECTIONS, REMOVALS, RELOCATIONS <br />AND/OR RECONNECTIONS OF EXISTING FIRE <br />PROTECTION EQUIPMENT REQUIRED, AND <br />CONDITIONS IN THE PROPOSAL FOR THIS PROJECT. <br />NO EXTRA COMPENSATION WILL BE PAID FOR LACK <br />OF SUCH DETERMINATION, FAMILIARIZATION, <br />AND/OR ALLOWANCE. <br />4. SUBMIT A REQUEST FOR INFORMATION FOR <br />QUESTIONS REGARDING THE FIRE PROTECTION <br />DOCUMENTS PER RFI PROCESS LOCATED IN THE <br />FIRE PROTECTION SPECIFICATIONS. <br />5. NEUTRALIZATION WALLS, IF PROVIDED, ARE SHOWN <br />ON THE ARCHITECTURAL DRAWINGS. REFER TO <br />MECHANICAL DRAWINGS FOR NEUTRALIZATION <br />WALL PENETRATION DETAIL. <br />6. PENETRATIONS OF "RATED ASSEMBLIES" SHALL BE <br />FIRE STOPPED WITH AN APPROVED MATERIAL PER <br />METHODS REQUIRED BY PROJECT SPECIFICATIONS <br />AND THE AUTHORITY HAVING JURISDICTION. <br />MECHANICAL SYMBOLS <br />18"x12" <br />RECTANGULAR DUCT 18" WIDE <br />BY 12" DEEP <br />12" 0 <br />12" DIAMETER ROUND DUCT <br />SUPPLY DUCT IN SECTION <br />RETURN OR EXHAUST DUCT IN <br />SECTION <br />ELBOW WITH TURNING VANES <br />TEE WITH TURNING VANES <br />ROUND (OR OVAL) ELBOW <br />VOLUME/BALANCE DAMPER <br />SUPPLY AIR DIFFUSER WITH <br />ROUND SUPPLY DUCT <br />RETURN OR EXHAUST AIR DIFFUSER <br />WITH ROUND DUCT <br />24"x24" <br />CD <br />450 <br />BRANCH DUCT AND/OR NECK SIZE <br />DIFFUSER OR GRILLE TYPE <br />CFM <br />0 <br />THERMOSTAT <br />@S <br />TIMER <br />O <br />TEMPERATURE SENSOR <br />CONNECT TO EXISTING <br />ETR <br />EXISTING TO REMAIN <br />FD <br />FIRE DAMPER <br />EXISTING CONDITIONS WERE TAKEN FROM <br />ORIGINAL DRAWINGS AND MAY NOT REFLECT <br />EXACT "AS -BUILT" CONDITIONS. CONTRACTOR <br />SHALL FIELD VERIFY ALL EXISTING CONDITIONS <br />PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR <br />SHALL CAREFULLY COORDINATE NEW WORK AND <br />DEMOLITION WITH ALL OTHER DISCIPLINES AND <br />EXISTING CONDITIONS. <br />GENERAL NOTES CONT. <br />7. THE FIRE PROTECTION ENGINEER OF RECORD <br />SHALL NOT BE RESPONSIBLE FOR THE <br />CONTRACTOR'S FAILURE TO CARRY OUT THE <br />CONSTRUCTION WORK IN ACCORDANCE WITH THE <br />CONTRACT DOCUMENTS, NOR SHALL THEY BE <br />REQUIRED TO SUPERVISE THE CONDUCT OF THE <br />WORK, THE CONSTRUCTION PROCEDURES <br />FOLLOWED BY THE CONTRACTOR, <br />SUBCONTRACTORS, THEIR RESPECTIVE <br />EMPLOYEES OR ANY OTHER PERSON AT THE JOB <br />SITE OTHER THAN THAT OF THE ENGINEERING <br />FIRM'S EMPLOYEES. <br />8. CONTRACTOR MUST REVIEW ALL CONSTRUCTION <br />DOCUMENTS PRIOR TO BID. SHOULD <br />MODIFICATIONS TO THESE PLANS BECOME <br />NECESSARY TO PROPERLY COORDINATE THE <br />SYSTEM WITH ALL OTHER TRADES, IT WILL BE THE <br />CONTRACTOR'S RESPONSIBILITY TO OBTAIN <br />APPROVAL OF THE CHANGES FROM BOTH THE <br />AUTHORITY HAVING JURISDICTION AND THE <br />OWNER'S DESIGNATED REVIEW CONSULTANT IN <br />ADDITION TO OBTAINING THE NECESSARY <br />APPROVALS, THE CONTRACTOR MUST MAKE NOTE <br />OF ANY FIELD OR COORDINATION CHANGES ON THE <br />INSTALLATION DRAWINGS, AND THEN MUST <br />PROVIDE A SET OF AS -BUILT DRAWINGS ONCE <br />COMPLETE. <br />9. CONTRACTOR MUST VERIFY ALL DROP DOWN <br />LOCATIONS AT EXTERIOR WALLS WITH THE <br />PROJECT MANAGER PRIOR TO INSTALLATION. <br />10. ALL PIPING MUST BE COORDINATED AROUND <br />FRAMING MEMBERS AND PROPERLY INSTALLED <br />INSIDE THE BAR JOIST. <br />11. CONTRACTOR SHALL ROUTE PIPING AROUND ALL <br />OBSTRUCTIONS AND PROVIDE SPRINKLER <br />PROTECTION UNDER OBSTRUCTIONS, AS DETAILED <br />IN NFPA 13 STANDARDS AS PART OF THE FIELD <br />COORDINATION AT NO ADDITIONAL COST TO <br />OWNER. <br />12. ALL SPRINKLER DEFLECTOR DISTANCE <br />REQUIREMENTS SHALL BE IN ACCORDANCE TO THE <br />STANDARDS OUTLINED IN NFPA 13. <br />13. ALL PIPING PASSING THROUGH CMU WALLS SHALL <br />BE INSTALLED WITH ONE INCH CLEARANCE ON ALL <br />SIDES. (CORE DIAMETER EQUAL TO PIPE +2"). ALL <br />CORES SHALL BE COORDINATED WITH STRUCTURAL <br />REINFORCING. CONTRACTOR IS RESPONSIBLE FOR <br />PROVIDING ALL CORING WITH PROPER CLEARANCE <br />AT ALL CMU WALLS. GENERAL CONTRACTOR SHALL <br />BE RESPONSIBLE FOR PROVIDING A TWO INCH <br />CLEARANCE AROUND ALL PIPING PASSING <br />THROUGH CONCRETE SLABS. THE SPRINKLER <br />CONTRACTOR SHALL FILL ALL CLEARANCES WITH <br />APPROVED MASTIC. <br />14. PROVIDE FLUSHING CONNECTIONS IN ACCORDANCE <br />WITH THE STANDARDS OUTLINED IN NFPA 13. <br />15. PROVIDE ALL NECESSARY OFFSETS, RISES OR <br />DROPS IN PIPING AND AUXILIARY DRAINS REQUIRED <br />BY BUILDING CONDITIONS. <br />16. EXAMINE THE JOB CONDITIONS AND VERIFY ALL <br />MEASUREMENTS, DISTANCES, ELEVATIONS, <br />CLEARANCES, ETC. <br />17. ARCHITECTURAL AND ELECTRICAL BACKGROUND <br />INFORMATION IS SHOWN FOR COORDINATION <br />PURPOSES ONLY. REFER TO THE CONTRACT <br />DOCUMENTS FOR LOCATIONS, SIZES AND <br />QUANTITIES OF OTHER TRADE WORK. <br />18. SPRINKLER SPACING SHALL BE PER NFPA 13 <br />UNLESS OTHERWISE NOTED ON PLANS AND/ OR <br />PROTECTION CRITERIA LEGEND. <br />19. INTERFACE SPRINKLER SYSTEM WITH FIRE <br />PROTECTION SUPERVISORY SYSTEM. <br />20. ALL MATERIALS SHALL BE UL LISTED OR FM <br />APPROVED. SPRINKLER PIPE SHALL BE <br />MANUFACTURED TO STANDARDS RECOGNIZED BY <br />NFPA 13., THREADED PIPE SHALL HAVE A <br />CORROSION RESISTANCE RATING OF 1.0 OR <br />GREATER. CRIMP -TYPE COUPLINGS SHALL NOT BE <br />USED. THREADABLE THINWALL PIPE WITH <br />CORROSION RESISTANCE RATING OF LESS THAN 1.0 <br />SHALL BE USED ONLY WITH ROLL GROOVE FITTINGS. <br />21. IF REQUIRED, PROVIDE 24 VOLT AC, ELECTRIC BELL, <br />MODEL NO. PBA248, ELECTRIC BELL BY POTTER <br />ELECTRIC SIGNAL OF ST. LOUIS, MISSOURI, LOCATE <br />AS REQUIRED BY AUTHORITIES HAVING <br />JURISDICTION. PROVIDE NEW DOUBLE POLE VANE <br />TYPE FLOW DETECTOR, MODEL NO. VSR-F, BY <br />POTTER ELECTRIC SIGNAL OF ST. LOUIS, MISSOURI. <br />SET ADJUSTABLE DELAYED SIGNAL AT 30 SECONDS. <br />MOUNT WATER FLOW INDICATORS NO HIGHER THAN <br />6 FEET ABOVE FINISH FLOOR. <br />22. ALL SPRINKLER SYSTEMS THAT ARE TO BE <br />MODIFIED SHALL BE HYDROSTATICALLY TESTED PER <br />NFPA 13 PRIOR TO SPRINKLER SYSTEM <br />MODIFICATION AND SHALL BE RE -HYDROSTATICALLY <br />TESTED AFTER COMPLETION OF WORK. <br />23. DO NOT HANG OR SUPPORT ANY LOADS OR MAKE <br />ANY ATTACHMENTS TO THE METAL ROOF DECK OR <br />JOIST BRIDGING. <br />24. SAMMY SCREWS ARE NOT PERMITTED. <br />25. CEILING FLANGES ARE NOT PERMITTED. <br />26. PROVIDE RETAINING STRAPS ON HANGERS WHERE <br />REQUIRED. <br />27. CONTRACTOR IS TO COORDINATE FINAL SPRINKLER <br />HEAD LOCATIONS AND PIPE ROUTING SUCH THAT <br />THEY DO NOT INTERFERE WITH NOR RECEIVE <br />DAMAGE FROM THE NORMAL OPERATIONS OF THE <br />AREA. <br />28. THE CONTRACTOR SHALL DIVERT ALL DRAINS AND <br />INSPECTORS TEST CONNECTION DISCHARGE AWAY <br />FROM FINISHED SURFACES AND PIPE TO APPROVED <br />DRAIN LOCATIONS. ROUTE DISCHARGE TO NEARBY <br />GREENSPACE OR STORM WATER DRAIN BY USE OF <br />BACKWASH HOSE.. THE CONTRACTOR WILL BE <br />BACKCHARGED FOR ANY REPAIR, REPLACEMENT, <br />OR CLEANING OF RUST STAINS ON <br />PAVEMENT,/CONCRETE DUE TO WATER DISCHARGE <br />FROM SPRINKLER SYSTEM DRAINS. <br />EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING <br />A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br />SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE <br />TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES <br />NOT RELIEVE THE RESPONSIBILITY OF PERFORMING <br />THE WORK PROPERLY. NO ADDITIONAL <br />COMPENSATION SHALL BE ALLOWED BECAUSE OF <br />CONDITIONS THAT OCCUR DUE TO FAILURE TO <br />FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. <br />p+enb2 <br />hitecture <br />ginee(ng <br />2809 Ajax Avenue Suite 100 <br />Rogers Arkansas 72758 <br />Phone: 479.636.3545 <br />Fax: 479.636.1209 <br />Engineer of Record <br />Joshua Dale McCall, P.E. <br />Florida License No. 79905 <br />COA License No. 26880 <br />w uw w �"6w <br />w Do Wwop> <br />� <br />co O W,-) aw""R� <br />J ­ww�z�-aazm <br />w w <br />wz <br />F-tnLLlllLLp�p W� <br />wa~¢g�awaaiom <br />0 ��c�Zza�W��=a> <br />U_ aFEmaot-O=>a~� <br />z <990 -u we oW�o=p <br />~ ZdJ�oot,TwFQp <br />�Qia-w��w`no�ZN <br />0 w 0-JUtgJ�Wp0E <br />4 pOiww¢�x�QMzacwn=g <br />~ T U)W oQ p cr U. X W U Uj W WS2 <br />� HpNUpwmoWmJwKa1- <br />m <br />H <br />z <br />J <br />Cl) <br />z <br />0 <br />U <br />N <br />rn <br />00 <br />Q <br />CD C:D <br />Q <br />0 O <br />0 <br />LjL <br />0 <br />ti <br />O <br />0 <br />m <br />N <br />o <br />w <br />O <br />J <br />o <br />a <br />J <br />J <br />Q <br />z <br />w <br />N= <br />LL <br />COO <br />00 <br />o <br />O <br />CL <br />N <br />N <br />w <br />N <br />w <br />m <br />0 <br />z <br />m <br />0 <br />ISSUE BLOCK <br />CHECKED BY: <br />JDM <br />DRAWN BY: <br />CMW <br />PROTO: <br />192 <br />PROTO CYCLE: <br />08-27-21 <br />DOCUMENT DATE: <br />10-01-21 <br />�Q N - E MCC'9 <br />No. 79905 <br />0 STATE of <br />�ORIDP �k <br />10/5/2021 <br />DOCUMENTS THAT DO NOT <br />HAVE THE ARCHITECT OR <br />ENGINEER OF RECORD SEAL <br />AND SIGNATURE SHALL BE <br />CONSIDERED NOT FOR <br />CONSTRUCTION <br />ENLARGED <br />MECHANICAL <br />PLANS <br />PENDENT SPRINKLER WITH FLEXIBLE PIPING <br />12" = 1'-0" <br />PHARMACY HVAC- PLAN <br />1/4" = 1'-0" <br />SHEET: <br />m 1 <br />