ELECTRICAL SYMBOLS GENERAL MODULAR NOTES <br />LEGEND <br />04.24.20 <br />(SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS) <br />1. COORDINATE AREA OF EXISTING CEILING GRID TO <br />SYMBOL DESCRIPTION BE REPLACED WITH GENERAL CONTRACTOR. <br />LIGHT FIXTURE COORDINATE ANY REQUIRED ELECTRICAL WORK <br />FO =1/0 O (WALL MOUNTED/CEILING MOUNTED) INCLUDING REMOVAL OF EXISTING FIXTURES. <br />MAINTAIN EXISTING LAYOUT, CIRCUITRY, AND <br />CONTROLS UNLESS OTHERWISE NOTED. <br />O <br />LIGHT FIXTURE <br />LIGHT FIXTURE, <br />NIGHT LIGHT <br />2 <br />VOLUMETRIC LIGHT FIXTURE <br />3 <br />17 <br />ZA <br />TRACK LIGHTING <br />/ ® <br />EXIT FIXTURE <br />(WALL MOUNTED/CEILING MOUNTED) <br />4 <br />/ coy <br />EMERGENCY LIGHT <br />(WALL MOUNTED/CEILING MOUNTED) <br />aN / <br />EMERGENCY LIGHT REMOTE HEADS <br />(WALL MOUNTED/CEILING MOUNTED) <br />SINGLE POLE SWITCH <br />$3 <br />3-WAY SWITCH <br />5 <br />$4 <br />4-WAY SWITCH <br />$K <br />KEYED SWITCH <br />6 <br />$D <br />DIMMER SWITCH <br />*VS <br />VARIABLE SPEED SWITCH <br />$M <br />MANUAL MOTOR SWITCH <br />$0S <br />SINGLE POLE OCCUPANCY <br />SENSOR SWITCH <br />$OS2 <br />DOUBLE POLE OCCUPANCY <br />SENSOR SWITCH <br />( <br />( OS ) <br />CEILING MOUNTED OCCUPANCY <br />SENSOR SWITCH, FOUR -DIRECTION <br />SENSING <br />7. <br />LIGHT FIXTURE SCHEDULE <br />"OW" FIXTURES AND LAMPS ARE FURNISHED BY THE OWNER FOR INSTALLATION BY THE CONTRACTOR. "GC" FIXTURES AND LAMPS ARE FURNISHED AND INSTALLED BY THE CONTRACTOR. <br />TYPE <br />SUPPLIED <br />BY <br />DESCRIPTION <br />VENDOR / <br />MANUFACTURER <br />MODEL <br />VOLTAGE <br />INPUT <br />VA <br />COLOR <br />TEMP <br />LIGHT SOURCE <br />LAMP <br />QTY <br />MOUNTING <br />COUNT <br />9 <br />OW <br />2' x 2' VOLUMETRIC TROFFER <br />CREE INC <br />ZR22C-40L-40K-10V-FD <br />120/277 <br />32 VA <br />4000K <br />INTEGRAL LED <br />RECESSED <br />2 <br />17 <br />OW <br />EMERGENCY LIGHT <br />REXEL INC <br />EVHC61DP-WM <br />120/277 <br />3 VA <br />- <br />INTEGRAL LED <br />- <br />WALL <br />1 <br />COORDINATE WITH GENERAL CONTRACTOR FOR <br />PHARMACY DEMOLITION REQUIREMENTS. <br />ELECTRICAL CONTRACTOR TO COORDINATE WITH <br />GENERAL CONTRACTOR ON ACTUAL PHASING OF <br />PHARMACY CONSTRUCTION. REUSE EXISTING <br />COUNTER BRANCH CIRCUITRY AS MUCH AS <br />POSSIBLE. <br />ELECTRICAL CONTRACTOR TO RELOCATE ALL <br />DRIVE THRU EQUIPMENT POWER AND DATA AS <br />REQUIRED. COORDINATE WITH GENERAL <br />CONTRACTOR AND CONSTRUCTION <br />MANAGER.PROVIDE LISTED HANDLE -TIE BETWEEN <br />FRONT COUNTER CIRCUIT BREAKERS THAT SHARE <br />COMMON NEUTRAL FOR SIMULTANEOUS TRIP. <br />PHARMACY REFRIGERATION SYSTEMS TO REMAIN <br />ENERGIZED DURING ALL PHASES OF <br />CONSTRUCTION. <br />PHARMACIST BENCH CAN BE RELOCATED PER THE <br />FOLLOWING MAXIMUM DIMENSIONS, AS NEEDED <br />TO RELOCATE THE POWER POLE THAT IS PLACED <br />OPPOSITE END OF BENCH FROM HEALTH SERVICE <br />ROOM TO MISS OBSTRUCTIONS IN THE CEILING <br />ABOVE POWER POLE (LIGHTING AND/OR <br />DIFFUSERS). THE BENCH CAN SLIDE A MAXIMUM 6" <br />TO EITHER SIDE. THE BENCH MUST BE A MINIMUM <br />OF 4'-0" FROM FRONT OF WILL CALL TO THE FRONT <br />COUNTER, AND A MINIMUM OF 4'-0" FROM REAR OF <br />WIRING DIAGRAM <br />BENCH TO FILL POD. COORDINATE WITH GENERAL <br />CONTRACTOR PRIOR TO PHARMACIST BENCH <br />GROUND �-) (BARE OR GREEN) <br />ANCHORING <br />LINE 1 (BLACK) <br />PROVIDE LISTED HANDLE -TIE BETWEEN FRONT <br />LINE 2 ( (RED) <br />COUNTER CIRCUIT BREAKERS THAT SHARE <br />LINE 3 ( (BLUE) <br />COMMON NEUTRAL FOR SIMULTANEOUS TRIP. <br />NEUTRAL (WHITE) <br />WALL MOUNTED OCCUPANCY SENSOR 8. BRANCH CIRCUITRY AT FRONT COUNTER TO BE <br />OS SWITCH, ONE -DIRECTION SENSING RUN THROUGH SIDEWALLS. COORDINATE DEVICE TRA <br />MOUNTING WITH JUNCTION BOXES PRE INSTALLED BUIL <br />RECEPTACLE, DUPLEX IN PANELS. MANU <br />RECEPTACLE DUPLEX 9 VENDOR FURNISHED MODULAR POWER <br />MOUNTED HORIZONTALLY <br />16 <br />RECEPTACLE, GFI <br />0 <br />RECEPTACLE, DUPLEX FLUSH FLOOR <br />RECEPTACLE, DUPLEX ISOLATED <br />0 <br />GROUND FLUSH FLOOR <br />1 <br />RECEPTACLE, DOUBLE DUPLEX <br />}� <br />RECEPTACLE, DUPLEX <br />ll <br />ISOLATED GROUND <br />1 <br />RECEPTACLE, DOUBLE DUPLEX, <br />U <br />NSITION <br />BETWEEN <br />DING WIRING AND <br />FACTURED WIRING <br />DISTRIBUTION INCLUDES ALL REQUIRED LINE N L1 G N L2 G <br />ENTRY CABLES, POWER -TO -POWER CABLE (LINE 1) (LINE 2) <br />ASSEMBLIES, POWER DISTRIBUTION MODULES, <br />POWER STRIPS AND OUTLETS. REFER TO <br />MANUFACTURER'S INSTRUCTIONS FOR PROPER MODULAR <br />MOUNTING OF MODULAR POWER DISTRIBUTION. <br />0. WHEN MAKING FINAL CONNECTIONS, ELECTRICAL 6 NTS <br />CONTRACTOR TO CONNECT DEVICES TO MODULAR <br />POWER IN THAT SECTION OF COUNTER ONLY. DO <br />NOT CONNECT TO OTHER SECTIONS OF FRONT <br />COUNTER. <br />1. ELECTRICAL CONTRACTOR TO INSTALL VENDOR <br />FURNISHED 50' WHIP FOR PHARMACIST BENCH IF <br />ISOLATED GROUND <br />PANELBOARD BEING USED TO SERVE WHIP <br />CIRCUITS IS MORE THAN 50' CIRCUIT FEET, <br />RECEPTACLE, SIMPLEX TWIST LOCK, <br />L5-15R, UNO <br />ELECTRICAL CONTRACTOR TO SPLICE FEEDER TO <br />WHIP PER NEC. DO NOT SPLICE WHIP IF <br />PANELBOARD IS LESS THAN 50' CIRCUIT FEET <br />RECEPTACLE, SIMPLEX TWIST LOCK, <br />ISOLATED GROUND, L5-15R, UNO <br />FROM PHARMACIST BENCH. <br />RECEPTACLE, DUPLEX TWIST LOCK, <br />IZPI <br />, <br />PANELBOARD NOTES Q <br />40- <br />RECE <br />RECEPTAACLCL E, DUPLEX TWIST LOCK, <br />ISOLATED GROUND, L5-15R, UNO <br />08.28.20 <br />RECEPTACLE, SPECIAL <br />1. <br />RECEPTACLE, SIMPLEX <br />2' <br />RECEPTACLE, PLUG -MOLD <br />O <br />JUNCTION BOX <br />3. <br />(WALL MOUNTED/CEILING MOUNTED) <br />THERMOSTAT <br />O <br />(WALL MOUNTED/CEILING MOUNTED) <br />4 <br />O <br />ALARM JUNCTION BOX, <br />5. <br />(WALL MOUNTED/CEILING MOUNTED) <br />ALARM JUNCTION BOX, <br />6. <br />® <br />FOR REMOTE TEST/RESET <br />(WALL MOUNTED/CEILING MOUNTED) <br />OS <br />SMOKE DETECTOR <br />7. <br />Eh <br />NON -FUSED DISCONNECT <br />8. <br />FUSED DISCONNECT <br />9. <br />EQUIPMENT CONNECTION POINT <br />1 <br />(PROVIDED WITH EQUIPMENT) <br />1 <br />CIRCUIT, CONCEALED IN WALLS OR <br />CEILING, E INDICATES EXISTING WIRING <br />CIRCUIT, CONCEALED IN SLAB FLOOR, <br />E INDICATES EXISTING WIRING <br />CIRCUIT, EXPOSED, <br />E INDICATES EXISTING WIRING <br />1 <br />------------ <br />LOW VOLTAGE WIRING <br />F--i <br />CONDUIT SLEEVE <br />1 <br />= <br />FLUSH MOUNTED PANELBOARD <br />1 <br />SURFACE MOUNTED PANELBOARD <br />1 <br />- <br />TELEPHONE / DATA BOX FOR ISD <br />1 <br />LOW VOLTAGE CABLE <br />1 <br />BOX FOR OTHER <br />© <br />TELEPHONE, FLUSH FLOOR <br />1 <br />O <br />MOTOR <br />z <br />TELEPOWER POLE <br />1 <br />PUSH BUTTON <br />2 <br />BUZZER <br />SAIL SWITCH <br />HSS <br />JUNCTION BOX <br />2 <br />( KI <br />HORN/STROBE <br />DH <br />DOOR HOLD OPEN <br />2 <br />ETC <br />TIME CLOCK <br />ABBREVIATIONS <br />2 <br />a, b, c <br />LOWER CASE LETTERS INDICATE <br />SWITCHING CONFIGURATION <br />2 <br />AFF <br />ABOVE FINISHED FLOOR <br />AFG <br />ABOVE FINISHED GRADE <br />C <br />CONDUIT <br />CCT <br />CIRCUIT <br />CIF <br />CEILING FAN <br />CW <br />CASH WRAP <br />EC <br />ELECTRICAL CONTRACTOR <br />EF <br />EXHAUST FAN <br />2 <br />ETR <br />EXISTING TO REMAIN <br />EWC <br />ELECTRIC WATER COOLER <br />G <br />GROUND <br />GC <br />GENERAL CONTRACTOR <br />GFEP <br />GROUND FAULT EQUIPMENT PROTECTION <br />G <br />GFI <br />GROUND FAULT CIRCUIT INTERRUPTER <br />1 <br />HD <br />HAND DRYER <br />IG <br />ISOLATED GROUND <br />LCU <br />LIGHTING CONTROL UNIT <br />NL <br />NIGHT LIGHT <br />NTS <br />NOT TO SCALE <br />2 <br />REC <br />REFRIGERATION ELECTRICAL CONTRACTOR <br />RC <br />REFRIGERATION CONTRACTOR <br />RH <br />RADIANT HEATER <br />Sc <br />SECURITY CAMERA <br />TR <br />TAMPER RESISTANT <br />TYP <br />TYPICAL <br />3 <br />UH <br />UNIT HEATER <br />UNO <br />UNLESS NOTED OTHERWISE <br />WH <br />WATER HEATER <br />WP <br />WEATHER PROOF <br />WR <br />WEATHER RESISTANT <br />MODULAR WHIP WIRING: <br />2 CIRCUIT WHIPS WITH UPS: ELECTRICAL CONTRACTOR TO <br />WIRE WHIP'S TO LINE 1, LINE 2, NEUTRAL AND ISOLATED <br />GROUND. <br />3 CIRCUIT WHIPS (NO UPS): ELECTRICAL CONTRACTOR TO <br />WIRE WHIP'S TO LINE 1, LINE 2, LINE 3, NEUTRAL, AND <br />GROUND. <br />REFER TO MODULAR POWER WIRING DIAGRAM 6-EPHM1. <br />TERMINATE GROUND ON ISOLATED GROUND BUS. <br />CIRCUITS FEEDING FRONT COUNTER <br />INSTALL LOCKING DEVICE (LOCK -OFF FOR <br />ARE SUPPLIED VIA ONE WHIP. EXTEND <br />° <br />MAINTENANCE). LOCKING DEVICE SHALL BE UL <br />FEEDERS AND SPLICE TO WHIP PER NEC. <br />LP-a,b,c <br />LISTED. MANUFACTURER SHALL MATCH EXISTING <br />16.145 <br />PANELBOARD MANUFACTURER. <br />LU2 w <br />INSTALL LOCKING DEVICE (LOCK -ON FOR CRITICAL <br />16.145 <br />LOAD). <br />IG w <br />2 <br />1 3 2 <br />POWER AND DATA FOR <br />GFI BREAKER FOR PERSONNEL PROTECTION (5MA). <br />DIGITAL DISPLAYS, +104" AFF. <br />GFI BREAKER FOR EQUIPMENT PROTECTION (30MA). <br />P <br />P P <br />VA <br />CONDUCTOR SIZE HAS BEEN INCREASED FOR <br />HEALTH <br />VOLTAGE DROP. SIZE EQUIPMENT GROUNDING <br />SERVICES <br />P® <br />w <br />CONDUCTOR PROPORTIONATELY PER NEC. <br />ROOM <br />LP <br />16.145 <br />16.451 <br />REFER TO ONE -LINE DIAGRAM FOR AVAILABLE FAULT <br />CURRENT FOR INTERRUPT RATINGS. <br />+24" <br />N L3 G <br />GROUND <br />LINE 1 <br />LINE 2 <br />ISOLATED <br />GROUND <br />NEUTRAL <br />TRAP <br />BUIL <br />MANU <br />WIRING DIAGRAM WITH ISOLATED GROUND <br />(BARE OR GREEN) <br />(BLACK) <br />_ (RED) <br />(GREEN WITH <br />YELLOW STRIPE) <br />(WHITE) <br />UU <br />lSITION BETWEEN <br />DING WIRING AND <br />FACTURED WIRING <br />(LINE 3) N Li IG <br />(LINE 1G) <br />POWER WIRING DIAGRAM <br />"1 3m, 2 1 <br />0 0 <br />REFER TO ONE -LINE DIAGRAMS FOR WIRE SIZES. /d <br />HEALTH SERVICES RECEPTACLES, SWITCHES, <br />FACTORY WIRED TO LOAD. DATA BOXES AND THEIR CORRESPONDING <br />COVER PLATES SHALL BE WHITE NYLON. <br />0. BREAKER SHALL BE HIGH MAGNETIC TYPE. L LP <br />1. BREAKER REMOVAL - FIELD VERIFY CIRCUIT 16.145 P® <br />BREAKER IS NOT SERVING AN EXISTING LOAD. IF NO <br />EXISTING LOAD, REMOVE CIRCUIT BREAKER AND <br />PROVIDE FILLER PLATE. IF BREAKER IS SERVING A <br />LOAD, IDENTIFY LOAD SERVED. UPDATE CIRCUIT <br />IDENTIFICATION SCHEDULE AS "SPACE" OR INDICATE <br />LOAD SERVED. <br />2. DUAL TAP SOLENOID OPERATED BREAKER. CONNECT <br />EMERGENCY/NIGHT LIGHTING TO UNSWITCHED TOILET <br />TERMINATION. <br />3. EXISTING CIRCUIT AND/OR CIRCUIT BREAKER. ■ <br />4. ROUTE CIRCUIT THROUGH CONTACTOR. <br />n <br />5. PROVIDE INTERLOCK WIRING WITH EXHAUST HOOD n <br />ANSUL SYSTEM. <br />6. RELOCATED CIRCUIT FROM EXISTING PANELBOARD. <br />7. PROVIDE BLANK CIRCUIT BREAKER FILLER PLATE PHARMACY POWER PLAN <br />FOR EXPOSED SPACE IN PANELBOARD. <br />9. <br />0. <br />1. <br />2. <br />4. <br />5. <br />/� <br />T <br />1 /4" = V-0" <br />8. PROVIDE U.L. LISTED OVERCURRENT DEVICE TO <br />COORDINATE AND MAINTAIN MANUFACTURER'S <br />SERIES RATED SYSTEM. <br />HEALTH SERVICES RECEPTACLES, SWITCHES, <br />EXISTING CIRCUIT BREAKER TO REMAIN. VERIFY <br />DATA BOXES AND THEIR CORRESPONDING <br />CONDITION OF CIRCUIT BREAKER TO ENSURE THAT IT <br />COVER PLATES SHALL BE WHITE NYLON. <br />IS OPERATIONAL AND MEETS ALL U.L. RATINGS. <br />ROUTE CIRCUIT THROUGH EXISTING LCU CABINET <br />UTILIZING EXISTING RELAY AND CONTROLS. UPDATE <br />P$ <br />JUNCTION BOX FOR <br />LCU IDENTIFICATION SCHEDULE WITH LOAD <br />P$OS/D <br />SWITCH PRE -INSTALLED <br />IDENTIFICATION. <br />BY MODULAR <br />MANUFACTURER. <br />SOLENOID OPERATED CIRCUIT BREAKER. REFER TO <br />ENERGY MANAGEMENT PLANS FOR CIRCUIT <br />LUTRON MAESTRO 0-10V DIMMER/VACANCY <br />BREAKER CONTROL. <br />SENSOR MS-Z1 01 -V-IV. PROGRAM FOR MANUAL <br />ON AT 100% LIGHT LEVEL AND 15 MINUTE <br />TIME <br />EXISTING LOAD - TRACE EXISTING CIRCUIT, IDENTIFY <br />DELAY. WIRE PER MANUFACT <br />R R'S <br />LOAD AND UPDATE CIRCUIT IDENTIFICATION <br />RECOMMENDATIONS. <br />SCHEDULE FOR LOAD SERVED. IF CIRCUIT IS NOT IN <br />P <br />USE, REFER TO PANELBOARD NOTE (11). <br />ab <br />DIMMING CONTROL ROUTED <br />3. ROUTE CIRCUIT THROUGH ENCLOSED GFI BREAKER <br />TO FIXTURE, TYP OF 2. <br />FOR PERSONNEL PROTECTION (5MA). <br />HEALTH <br />SPARE - FIELD VERIFY CIRCUIT BREAKER IS NOT <br />SERVICES <br />Q <br />a <br />SERVING AN EXISTING LOAD. IF NO EXISTING LOAD, <br />S <br />ROOMS <br />- <br />PROVIDE LOCK OFF DEVICE TO LOCK SPARE <br />17 <br />a <br />BREAKER IN THE OFF POSITION. IF BREAKER IS <br />0 <br />SERVING A LOAD, IDENTIFY LOAD SERVED. UPDATE <br />LIGHTING <br />LIGHTING FIXTURE SUPPLIED <br />C <br />CIRCUIT IDENTIFICATION SCHEDULE AS "SPARE" OR <br />OWNER AND INSTALLED BY <br />INDICATE LOAD SERVED. <br />PANEL MANUFACTURER. FINAL e <br />EXISTING LOAD - TRACE EXISTING CIRCUIT, IDENTIFY <br />CONNECTIONS BY E.C. TYP OF 2. <br />LOAD AND UPDATE CIRCUIT IDENTIFICATION <br />16.470 <br />SCHEDULE FOR LOAD SERVED. IF CIRCUIT IS NOT IN <br />o <br />USE, REFER TO PANELBOARD NOTE (24). <br />16.125 E <br />ENERAL NOTES: <br />16.102 <br />b <br />NEW OVERCURRENT PROTECTIVE DEVICES PLACE IN <br />EXISTING PANELBOARDS OR DISTRIBUTION BOARDS <br />0 <br />SHALL MATCH THE TYPE AND AIC RATING OF <br />EXISTING OVERCURRENT PROTECTION DEVICES IN <br />SAID BOARD. <br />E.C. SHALL TRACE ALL ELECTRICAL CIRCUITS FOR <br />TOILET <br />EVERY EXISTING PANELBOARD AFFECTED BY THIS <br />'I] <br />-I <br />PROJECT. IDENTIFY LOADS ON EACH CIRCUIT. <br />I <br />PROVIDE A COMPLETE TYPEWRITTEN CIRCUIT <br />° <br />C <br />N L2 G NOT <br />(LINE 2G) USED <br />EXISTING ELECTRICAL DEVICES <br />NOT SHOWN TO REMAIN D-REG40 <br />D-RXPCO2 <br />D-RXPC01 D-RXZP02 <br />D-RXZP01 V-135 <br />V-134 <br />D-RXTV01 <br />CIRCUITRY NOTED WITH "W" INDICATES PRE- <br />MONITOR <br />MANUFACTURED WHIP. E.0 TO PROVIDE <br />V-137 <br />CONNECTION TO WHIP AS SHOWN. COORDINATE <br />EXACT LOCATION AND CIRCUIT CONFIGURATION <br />OF HEALTH <br />WHIP WITH ARCHITECTURAL DRAWINGS AND <br />MANUFACTURER'S INSTALLATION INSTRUCTIONS. SERVICES <br />ROOM <br />WIRING BETWEEN MODULAR <br />OUTLETS PROVIDED BY <br />MANUFACTURER, FINAL CONNECTION <br />BY GENERAL CONTRACTOR TYP, REF <br />°ARCH DWGS. ° <br />P-d,e,f <br />pq in 16.145 <br />X�aO� ���� Q��� w <br />ROUTE MANUFACTURER <br />G1G1G1G 3 2 1 2 1 <br />PROVIDED WHIP THROUGH <br />N21 <br />WALL PENETRATION AT 2'-4" <br />AFF TO EC INSTALLED <br />® ® ® <br />JUNCTION BOX LOCATED <br />IN WALL ABOVE CEILING. <br />CONNECT TO CIRCUITRY AS <br />SHOWN, TYP OF 2. <br />ROVIDE 2" CONDUIT WITH PULL <br />_ <br />IRE IN WALL FROM EC INSTALLED <br />o <br />NCTION BOX MOUNTED 2'-6" AFF <br />O ABOVE ACCESSIBLE CEILING <br />0 o <br />SPACE, TYP OF 2. <br />PHARMACY <br />° <br />a <br />ADDITION UNLESS NOTED <br />KEYNOTES <br />GENERAL LIGHTING NOTES <br />GENERAL NOTES <br />01.31.20 <br />08.28.20 <br />1. EXIT SIGN MOUNTING <br />1. FURNISH AND INSTALL ALL MATERIALS, EQUIPMENT, AND LABOR, <br />16.101 REPLACE ALL LIGHT LENSES WITH NEW <br />A. WALL FIXTURE: CENTER 12" ABOVE DOOR <br />FOR A COMPLETE INSTALLATION IN ALL RESPECTS, READY FOR <br />PRISMATIC ACRYLIC LENS FOR ALL LAY -IN LIGHT <br />OPENING. <br />INTENDED USE AND IN STRICT ACCORDANCE WITH NEC, NESC, <br />FIXTURES IN THIS AREA. <br />B. CEILING FIXTURE: ON CEILING OR AT HEIGHT <br />STATE, AND LOCAL CODES, AND MANUFACTURER'S <br />16.102 FURNISH AND INSTALL NEW TUBE GUARDS AND <br />SPECIFIED ON DRAWINGS. <br />RECOMMENDATIONS. PAY ALL NECESSARY FEES AND PERMITS. <br />CAPS ON ALL EXPOSED LAMPS IN THIS AREA. <br />C. PENDANT FIXTURE: MATCH HEIGHT OF EXISTING <br />16.125 EXISTING LIGHT FIXTURES TO REMAIN UNLESS <br />PENDANT MOUNTED EXIT SIGNS. IF STORE DOES <br />A. NO CIRCUITRY SHALL BE ALLOWED TO BE ROUTED ACROSS THE <br />NOTED OTHERWISE. <br />NOT HAVE PENDANT MOUNTED EXIT SIGNS, THEN <br />ROOF OR THE EXTERIOR SIDE OF THE EXTERIOR WALLS. <br />16.126 EXISTING LIGHT FIXTURE TO BE DEMOLISHED. <br />PENDANT MOUNT SIGN 24" BELOW BOTTOM OF <br />B. ALL EQUIPMENT SHALL BE UL LISTED WHERE APPLICABLE. <br />16.145 CONNECT CIRCUIT(S) TO EXISTING BRANCH <br />BAR JOIST. <br />C. ARRANGE ALL WORK TO MINIMIZE DISRUPTIONS TO STORE <br />CIRCUITRY. MINIMUM WIRE SIZE AND <br />D. VERIFY MOUNTING HEIGHT WITH AHJ. <br />OPERATIONS. COORDINATE ALL DISRUPTIONS WITH WALMART <br />PANELBOARD CIRCUIT ARE NOTED. VERIFY SIZE, <br />E. COORDINATE LOCATIONS OF EXIT SIGNS TO <br />CONSTRUCTION MANAGER AND STORE MANAGER. <br />RATING AND CONDITION OF EXISTING BRANCH <br />ENSURE STORE SIGNAGE DOES NOT OBSTRUCT <br />D. CONTRACTOR SHALL VERIFY ALL WALL FINISH THICKNESS <br />CIRCUIT CONDUIT AND WIRE PRIOR TO USE TO <br />THEIR VIEW. <br />BEFORE INSTALLING BOXES. FURNISH AND INSTALL EXTENDED <br />ENSURE THAT THEY MEET REQUIRED SIZE, AND <br />F. THE USE OF TRITIUM BASED RADIOACTIVE EXIT <br />BOXES OR BOX EXTENDERS WHERE REQUIRED. <br />ALL U.L. RATINGS AND REPLACE AS REQUIRED. <br />SIGNAGE IS PROHIBITED. <br />E. CONTRACTOR SHALL VERIFY THAT ALL AFFECTED <br />PANELBOARDS HAVE CIRCUIT BREAKER KNOCKOUTS <br />16.451 PROVIDE EMT WITH PROPERLY INSTALLED <br />2. EMERGENCY LIGHT FIXTURE INSTALLATION <br />PROPERLY COVERED ANDTHAT ALL TRIM IS IN GOOD <br />COMPRESSION OR SET -SCREW TYPE FITTINGS <br />A. WALL FIXTURE: 12" BELOW FINISHED CEILING OR <br />CONDITION, ALLOWING NO ACCESS TO LIVE PARTS. <br />AND AN INSULATED EQUIPMENT GROUNDING <br />+10'-0" IN AREAS OF EXPOSED STRUCTURE, <br />CONDUCTOR FOR ALL RACEWAYS SERVING THIS <br />UNLESS NOTED OTHERWISE. <br />2. PROVIDE SEALS AT RACEWAY PENETRATIONS AS FOLLOWS: <br />ROOM TO COMPLY WITH NEC, HEALTH CARE <br />B. PENDANT FIXTURE: BOTTOM CHORD OF BAR <br />A. FIRE RATED WALLS: SEAL PER SPECIFICATIONS FOR FIRE <br />FACILITIES. <br />JOIST OR AT HEIGHT SPECIFIED ON DRAWINGS. <br />STOPPING. <br />16.470 FURNISH AND INSTALL NEW 20 AMP, 120 VOLT <br />C. REMOTE HEAD FIXTURE: HEADS CENTERED <br />B. NEUTRALIZATION AREA: SEAL PER MECHANICAL DETAIL. <br />CIRCUIT(S). FEED FROM PANELBOARD AS <br />ABOVE DOOR OPENING +9'-0", UNLESS NOTED <br />C. FREEZER/COOLER BOXES: SEAL WITH EXPANDING FOAM <br />INDICATED. PROVIDE 20A-1 P CIRCUIT BREAKER <br />OTHERWISE AND BATTERY PACK MOUNTED ON <br />SEALANT. <br />IF NEEDED. E.C. SHALL MATCH MANUFACTURER, <br />INTERIOR SIDE OF WALL 12" BELOW FINISHED <br />D. EXTERIOR: REFER TO ARCHITECTURAL DOCUMENTS FOR <br />TYPE AND AIC RATINGS OF EXISTING CIRCUIT <br />CEILING OR AT BAR JOIST IN AREAS OF EXPOSED <br />SEALING REQUIREMENTS AT ALL EXTERIOR MOUNTED DEVICES, <br />BREAKERS. <br />STRUCTURE. <br />FIXTURES, ENCLOSURES, AND RACEWAY PENETRATIONS. <br />16.492 E.C. SHALL COORDINATE WITH GENERAL <br />D. REFER TO MANUFACTURER'S WRITTEN <br />CONTRACTOR AND ARCHITECTURAL <br />INSTRUCTIONS. ALLOW BATTERY TO CHARGE <br />3. PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR (SIZE <br />DEMOLITION PLANS THE EXTENT OF ELECTRICAL <br />CONTINUOUSLY FOR A MINIMUM OF 24 HOURS <br />PER NEC) IN PVC TYPE CONDUIT, POWER AND LIGHTING CIRCUITS, <br />DEMOLITION. REMOVE UNUSED DEVICES, <br />BEFORE INITIAL TESTING. <br />ISOLATED GROUND CIRCUITS, OR AS SHOWN ON PLANS. CONDUIT <br />BOXES, CONDUITS, AND WIRING BACK TO <br />E. AFTER EMERGENCY LIGHT HAS BEEN POWERED <br />SHALL BE SIZED PER NEC BASED ON THWN 600 VOLT COPPER <br />ORIGINATING JUNCTION BOXES OR <br />DO NOT TURN OFF FOR EXTENDED PERIODS OF <br />SINGLE CONDUCTORS, PLUS THE EQUIPMENT GROUNDING <br />PANELBOARDS. REFERENCE POWER PLANS FOR <br />TIME. <br />CONDUCTOR. <br />CIRCUITRY TO BE REUSED. DEMOLITION SHALL <br />NOT AFFECT ACTIVE CIRCUITS. IF CIRCUIT IS <br />3. EXIT SIGNS, EMERGENCY LIGHTS AND NIGHT LIGHTS <br />4. WIRING DEVICES: DEVICE MOUNTING HEIGHTS ARE FROM FINISHED <br />DEMOLISHED ALL THE WAY TO PANELBOARD, <br />SHALL NOT BE SWITCHED. <br />FLOOR TO CENTER OF OUTLET BOX UNLESS NOTED OTHERWISE ON <br />REMOVE CIRCUIT BREAKER AND REPLACE WITH <br />PLANS. COORDINATE THE STANDARD MOUNTING HEIGHTS WITH <br />FILLER PLATE. UPDATE TYPEWRITTEN CIRCUIT <br />4. IN AREAS OF OPEN STRUCTURE, MOUNT STRIP <br />MASONRY: <br />DIRECTORY IDENTIFYING CIRCUIT AS "SPACE". <br />FIXTURE TO BOTTOM CHORD OF BAR JOIST, UNLESS <br />A. SWITCHES +44" <br />COORDINATE EXACT REQUIREMENTS WITH <br />NOTED OTHERWISE. <br />B. RECEPTACLES +20" <br />EXISTING CONDITIONS PRIOR TO BID. <br />C. VOICE/DATA +20" <br />16.775 E.C. SHALL DISCONNECT, EXTEND, AND <br />5. PROVIDE SEPARATE BOXES FOR GANGED SWITCHES <br />RECONNECT ALL ELECTRICAL CIRCUITRY FOR <br />ON SEPARATE BRANCH CIRCUITS. <br />5. WIRING SHALL INCLUDE FINAL CONNECTION TO ALL EQUIPMENT IN <br />NEW OR RELOCATED EQUIPMENT. REFERENCE <br />CONFORMANCE WITH EQUIPMENT SUPPLIER WIRING DIAGRAMS. <br />POWER PLANS AS APPLICABLE. VERIFY <br />6. FIXTURES DENOTED WITH "ABS' ARE TO BE <br />CONDITION OF BRANCH CIRCUIT, CONDUIT, AND <br />FASTENED ON UNISTRUT CHANNELS MOUNTED TO <br />6. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AN UPDATED AND <br />WIRE PRIOR TO USE TO ENSURE THAT THEY <br />THE BOTTOM SIDE OF THE TOP CHORD OF BAR <br />COMPLETE TYPEWRITTEN CIRCUIT IDENTIFICATION SCHEDULE FOR <br />MEET ALL U.L. RATINGS AND REPLACE AS <br />JOISTS. LOCATE THE FIXTURES RUNNING <br />EVERY PANELBOARD AFFECTED BY THIS PROJECT. <br />REQUIRED. COORDINATE THIS PROCESS WITH <br />PERPENDICULAR TO BAR JOISTS WITHIN BAR JOISTS <br />CONSTRUCTION MANAGER TO MINIMIZE <br />WEBBING SPACES. DO NOT FASTEN FIXTURE OR <br />7. NEW OVERCURRENT PROTECTIVE DEVICES INSTALLED IN EXISTING <br />DOWNTIME. LABEL ALL ASSOCIATED <br />UNISTRUT CHANNELS TO ROOF DECK. <br />PANELBOARDS OR DISTRIBUTION BOARDS SHALL MATCH THE TYPE <br />PANELBOARD SCHEDULES TO REFLECT LOAD <br />AND AIC RATING OF EXISTING OVERCURRENT PROTECTIVE <br />DESCRIPTIONS. <br />GENERAL POWER NOTES <br />DEVICES. <br />8• BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG <br />D-REG4 D-REG42 <br />UNLESS NOTED OTHERWISE IN SCHEDULES. WHERE 20A BRANCH <br />D-RXPC03 D-RXPC04 <br />07,26.19 <br />CIRCUITS HAVE #8 AND LARGER WIRE SPECIFIED, #10 AWG WIRE <br />1. TELEPOWER POLE(S): MOUNT JUNCTION BOX(ES) TO <br />D-RXZP03 D-RXZP04 <br />SHALL BE USED FOR THE FINAL CONNECTION (15-FT MAXIMUM). <br />D-RXLP02 V-138 <br />TOP SIDE OF BOTTOM CHORD OF BAR JOIST. INSTALL <br />g WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT AND <br />V-1 6 D-RXPC05 <br />FURNISHED POWER POLE AND TERMINATE WIRING <br />DERATE CURRENT CARRYING CONDUCTORS PER NEC. <br />RXZP05 <br />TO JUNCTION BOX. PROVIDE UNISTRUT SUPPORTS <br />V-141 <br />AND HARDWARE TO SECURE TELEPOWER POLE <br />10. PROVIDE UL LISTED HANDLE TIES ON ALL MULTIWIRE BRANCH <br />PLUMB TO BUILDING STRUCTURE. REF POWER POLE <br />CIRCUITS PER NEC REQUIREMENTS. <br />e e e e <br />CONNECTION DETAIL. <br />2. PROVIDE LIQUID -TIGHT FLEXIBLE METAL CONDUIT <br />11. SUPPORTS FROM STRUCTURE: NO ATTACHMENT OF ANY TYPE <br />SHALL BE MADE TO BRIDGING OR JOIST WEB MEMBERS. UTILIZE <br />R <br />AND WIRING FROM DISCONNECT SWITCH OR <br />ONLY THE TOP AND BOTTOM CHORDS FOR SUPPORTING THE <br />0 0 0 <br />JUNCTION BOX TO EQUIPMENT KNOCKOUT <br />ELECTRICAL SYSTEM INSTALLATIONS. <br />ELECTRICAL CONNECTION POINT. <br />3. WHERE EQUIPMENT NAMEPLATE PROTECTIVE <br />12. DEVICES SHOWN ON COOLER/FREEZER PANELS SHALL BE <br />SURFACE MOUNTED UNLESS NOTED OTHERWISE. SEAL DEVICES TO <br />DEVICE RATING DIFFERS FROM SIZE PROVIDED, <br />COOLER/FREEZER PANELS WITH SILICONE SEALANT. <br />NOTIFY WALMART CONSTRUCTION MANAGER <br />IMMEDIATELY TO COORDINATE RESOLUTION. <br />13. SURFACE MOUNTED CONDUIT ON COOLER/FREEZER PANELS OR IN <br />FOOD PREP AREAS SHALL BE INSTALLED WITH GALVANIZED 1/2" <br />4. ELECTRONIC FIRE PROTECTION/SECURITY ALARM <br />STANDOFF CONDUIT HANGERS TO ALLOW FOR CLEANING. <br />BOXES AND CONDUITS SHOWN ON POWER PLANS <br />SHALL BE PROVIDED UNDER THIS CONTRACT. IN <br />OTHERWISE THE <br />14. ONLY FEEDER CIRCUITS NOTED ON THE ONE LINE DIAGRAM AND <br />` L n FOLLOWING GENERAL NOTES APPLY: BRANCH CIRCUITS NOTED BY LEGEND SHALL BE INSTALLED UNDER <br />A. ALL ALARM JUNCTION BOXES SHALL BE SLAB. PROVIDE EXTERIOR COATED GRC BENDS ON ALL CONDUIT <br />PHARMACY TELECOM PLAN 4"X4"X2-1 /8" MINIMUM. RUNS THAT HAVE 45 DEGREE BENDS OR GREATER. REFER TO <br />5 B. ALARM RACEWAYS SHALL BE 3/4" MINIMUM WITH SPECIFICATION SECTION 16.100 FOR UNDER SLAB. <br />1/8" = 1'-0" PULL WIRE AND INSULATING BUSHINGS AT END <br />OF VERTICAL RACEWAY RUN. <br />15. SEISMIC ZONE REQUIREMENTS. PROVIDE EXPANSION COUPLINGS <br />AND BRACING FOR ELECTRICAL EQUIPMENT AS REQUIRED BY <br />C. VERTICAL RACEWAYS FROM ALARM BOXES <br />LOCAL CODES. <br />SHALL BE EITHER CONCEALED INSIDE WALL OR <br />SURFACE MOUNTED (TO MATCH JUNCTION BOX <br />16. EXISTING ELECTRICAL AND ALARM: <br />MOUNTING). ALL VERTICAL RUNS SHALL BE <br />A. WHERE DEMOLITION OR NEW CONSTRUCTION INTERRUPTS <br />TURNED 90-DEGREES AT TOP SIDE OF BOTTOM <br />EXISTING ELECTRICAL CIRCUITS FEEDING EXISTING EQUIPMENT, <br />CHORD OF BAR JOIST AND EXTENDED <br />DEVICES, OR LIGHTING TO REMAIN, BUT NOT SHOWN ON <br />HORIZONTALLY TO A LOCATION ACCESSIBLE BY <br />DRAWINGS, PROVIDE LABOR AND MATERIALS TO REWORK <br />VERTICAL FLOOR TYPE LIFT. <br />CIRCUITRY, AS REQUIRED, TO MAINTAIN EXISTING OPERATION. <br />5. UPON COMPLETION OF ELECTRICAL INSTALLATION <br />B. IF DEMOLITION OR NEW CONSTRUCTION WILL DISRUPT <br />AND PRIOR TO ENERGIZING CIRCUIT: <br />EXISTING UNDERGROUND SERVICES (ELECTRICAL, TELEPHONE, <br />A. INSPECT WIRE AND CABLE FOR PHYSICAL <br />PARKING LOTLIGHTING CIRCUITRY, ETC.) PROVIDE ALL <br />MATERIALS AND LABOR AS REQUIRED TO REROUTE, SLEEVE, <br />DAMAGE. <br />OR OTHERWISE REWORK THESE SERVICES TO MAINTAIN THEIR <br />B. PERFORM CONTINUITY TEST. <br />EXISTING OPERATION <br />ELECTRICAL C. VERIFY PROPER PHASING CONNECTION TO ALL C. EXERCISE CAUTION AROUND ALARM AND SECURITY CABLES <br />° DEVICES AND THREE PHASE MOTOR LOADS. DURING DEMOLITION AND CONSTRUCTION. PROTECT ALARM <br />REF 4- EPHM1 CIRCUITRY AND SECURITY CABLES FROM ACCIDENTAL DAMAGE SO THAT <br />SYSTEMS 16.775 N OPERATIONAL AT ALL TIMES. <br />- 16.492 <br />-- 20A WIRE SIZING SCHEDULE D. DISPOSE OF ALL REMOVED MATERIALS, UNLESS OTHERWISE <br />��-�I-----�£C r----T ; NOTED. <br />_ - <br />---------------------� III �� - - - - - I ����- - - - - -�-� I <br />r 17. EXISTING ELECTRICAL DEMOLITION: <br />o f _ ___ ___ _____________ _ ALL WIRE SIZES SHOWN ON PLANEL SCHEDULES AND <br />C ; -----------------------' A. GENERAL: REMOVE OR RELOCATE EXISTING ELECTRICAL <br />_ PLANS ARE INTENDED TO BE MINIMUM ACCEPTABLE EQUIPMENT, CONDUIT AND CONDUCTORS AS INDICATED ON <br />WIRE SIZE. THE DRAWINGS, OR ONLY AS REQUIRED BY DEMOLITION. <br />' I ; <br />a THE FOLLOWING SCHEDULE IS TO BE USED TO SIZE REMOVE ALL PANELBOARDS, DISCONNECT SWITCHES, BOXES, <br />'-------�---\ -- -----; WIRE FOR 20 AMP CIRCUITS (120 AND 277 VOLT). RELAYS, TIME SWITCHES, LIGHTS, DEVICES, ETC., WHICH WILL <br />�- LENGHTS (IN FEET) ARE INTENDED TO BE MAXIMUM. NOT BE REUSED. <br />`' -- PHARMACY B. SALES FLOOR: REMOVE UNUSED POWER DROP CONDUIT, <br />lyl I� Ij I <br />lyl <br />lid^ �i1^ �i <br />0 0 0 0 <br />F7 <br />NL <br />TOILET <br />n <br />FINAL CONNECTIONS: WHERE 20A BRANCH CIRCUITS CONDUCTORS AND RELATED DEVICES SERVING SALES AREA <br />HAVE #8 AND LARGER WIRE CALLED OUT, #10AWG WIRE GONDOLAS BEING RELOCATED OR REMOVED. EXISTING <br />y y MAY BE USED FOR THE FINAL CONNECTION (15' MAX.). CONDUIT AND CONDUCTORS MAY BE REUSED FOR NEW POWER <br />DROPS WHERE SIZE, RATING, AND CONDITION MEET <br />REQUIREMENTS INDICATED ON PLANS AND ALL U L RATINGS <br />REMOVE ALL UNUSED CONDUIT AND CONDUCTORS BACK TO <br />POINT OF ORIGIN WHENEVER FEASIBLE. IF CIRCUIT IS NOT <br />REUSED, REMOVE CIRCUIT BREAKER AND REPLACE WITH <br />FILLER PLATE. EXCEPTION: DISTRIBUTION AND POWER SWITCH <br />PHARMACY DEMO POWER PLAN <br />BREAKERS SHALL BE ETR AS "SPARE". PROVIDE HANDLE LOCK <br />OFF DEVICE TO LOCK "SPARE" CIRCUIT BREAKER IN THE "OFF" <br />1/8" = V-0" POSITION. UPDATE TYPEWRITTEN CIRCUIT IDENTIFICATION <br />0X 0 0 <br />° 16.125 <br />NL <br />PHARMACY 16.492 <br />16.101 <br />°U 16.126 --- � <br />I III I ° <br />UUNL <br />107 107 107 flo <br />IDENTIFICATION SCHEDULE FOR EVERY AFFECTED <br />PANELBOARD. <br />ALL NOTED OTHERWISE. <br />R ENTWISE DEVICES ARE NEW UNLESS PHARMACY LIGHTING PLAN <br />NOTED OTHERWISE. <br />n <br />1/4" = 1'-0" <br />120 VOLT <br />#12 <br />#10 <br />#8 <br />#6 <br />1-5 AMPS <br />200 FT. <br />325 FT. <br />490 FT. <br />770 FT. <br />6-10 AMPS <br />100 FT. <br />160 FT. <br />245 FT. <br />385 FT. <br />11-15 AMPS <br />70 FT. <br />110 FT. <br />165 FT. <br />255 FT. <br />277 VOLT <br />#12 <br />#10 <br />#8 <br />#6 <br />1-5 AMPS <br />480 FT. <br />760 FT. <br />1170 FT. <br />1865 FT. <br />6-10 AMPS <br />240 FT. <br />380 FT. <br />585 FT. <br />930 FT. <br />11-15 AMPS <br />1 160 FT. <br />250 FT. <br />390 FT. <br />1 620 FT. <br />SCHEDULE AS "SPACE" OR "SPARE". <br />C. CONDUIT AND WIRING TO BE ABANDONED IN CEILING SPACES <br />AND OTHER NON-PUBLIC AREAS (I.E., THROUGH STOCKROOM <br />AREA): CUT WIRING LOOSE AND REMOVE FROM RACEWAY(S), <br />LEAVING RACEWAY(S) IN PLACE. CONDUIT TO BE ABANDONED IN <br />WALLS OR FLOORS SHALL BE REMOVED BACK TO FINISHED <br />SURFACE AND CAPPED INSIDE. REPAIR SURFACE(S) TO MATCH <br />ADJACENT. <br />D ALL CIRCUIT BREAKERS EREMOVED.REMOVECIRCUITRVING BRANCH CIRCUITS TO BE <br />LEGEND FOR MODULAR <br />REMOVED SHALL A SO E. <br />COMPONENTS <br />BREAKER AND REPLACE WITH FILLER PLATE. EXCEPTION: <br />DISTRIBUTION AND POWER SWITCH BREAKERS SHALL BE ETR <br />AS "SPARE". PROVIDE HANDLE LOCK OFF DEVICE TO LOCK <br />"SPARE" CIRCUIT BREAKER IN THE "OFF" POSITION. UPDATE <br />RECEPTACLE INSTALLED <br />TYPEWRITTEN CIRCUIT IDENTIFICATION SCHEDULE AS "SPACE" <br />IN POWER STRIP <br />OR "SPARE". <br />E. DEMOLISHED FLUORESCENT LIGHT FIXTURES: REFER TO <br />POWER STRIP <br />SELECTIVE SITE DEMOLITION SPECIFICATION FOR DISPOSAL OF <br />LIGHT FIXTURE. <br />MODULAR POWER DISTRIBUTION <br />F. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK <br />1 2 3 1 SYSTEM FURNISHED BY VENDOR, <br />SHALL BE SECURED TO PREVENT FALLING, LOOSENING, OR <br />INSTALLED BY E.C. <br />CREATING DAMAGE OF ANY KIND IN THE FUTURE. <br />NUMBER DENOTES WHICH CIRCUIT <br />18. DATA AND PHONE CONDUIT INSTALLATION MILESTONE DATE: <br />THE RECEPTACLE IS ATTACHED TO. <br />ALL RACEWAY AND CONDUIT SLEEVES FOR DATA AND PHONE <br />CABLING TO BE INSTALLED 3 WEEKS PRIOR TO CONTRACT <br />VOICE/DATA BOX PRE -INSTALLED BY <br />VP <br />SUBSTANTIAL COMPLETION DATE. <br />MODULAR MANUFACTURER. <br />19. ETHERNET CABLE: <br />A FURNISH AND INSTALL JUNCTION BOXES AS SHOWN ON PLANS <br />�� <br />P <br />OUTLET, BOX, AND WIRING BETWEEN <br />DEVICES PRE -INSTALLED BY MODULAR <br />PROVIDE CONDUIT AS REQUIRED BY LOCAL CODES AND/OR <br />_ _ _ _ _ _ _ _ _ <br />_ _ III T <br />- \ �I <br />_ <br />MANUFACTURER. E.C. TO MAKE FINAL <br />ORDINANCES. <br />TYP_ 16.125 1F <br />CONNECTION AS REQUIRED. <br />B. ETHERNET CABLE IS FURNISHED BY OTHERS. <br />C. ELECTRICAL CONTRACTOR SHALL INSTALL CABLE IN POWER <br />OA <br />ALARM SYSTEM JUNCTION BOX PRE- <br />POLES. <br />D. ELECTRICAL CONTRACTOR SHALL INSTALL OTHER CABLE AS <br />P <br />INSTALLED BY MODULAR <br />16.125 <br />MANUFACTURER. <br />DIRECTED BY WALMART CONSTRUCTION MANAGER. <br />o <br />o <br />TYP <br />16.125 <br />W <br />PRE -MANUFACTURED WHIP. E.C. TO <br />ANL <br />H <br />ANL <br />TH <br />Ell <br />PROVIDE CONNECTION TO WHIP AS <br />PH RM <br />Cy <br />SHOWN. <br />25 " IG <br />W PNL-#1 G <br />W PNL-#1,#2,#3 <br />OILET <br />CIRCUITS INDICATED IN HOMERUNS <br />FOR MODULAR EQUIPMENT <br />CORRESPOND TO LINE #'S IN DETAIL 4- <br />PHARMACY DEMO LIGHTING PLAN EPHM1. <br />1 /8" = V-0" <br />2 <br />p+enb <br />hitecture <br />gineering <br />2809 Ajax Avenue Suite 100 <br />Rogers Arkansas 72758 <br />Phone: 479.636.3545 <br />Fax: 479.636.1209 <br />Engineer of Record <br />Keith Allen Williams, P.E. <br />Florida License No. 64983 <br />COA License No. 26880 <br />UJ <br />> >o irWo�� <br />j <br />WwZ�a�zczn� <br />cc <br />xzLLmW�aW¢UO <br />¢ <br />Ir <br />.. �.. fA LL_W OLLort W <br />a¢ �rorwa�Qo�w <br />wwa}o;11 w �nmm <br />O <br />LL <br />mFn r�ZzaaWg�=a> <br />a - - cn <br />LLo�Lt:,O 3W�°1ZZo <br />U --WUOaQ2dJ aa dwz=¢ <br />. <br />¢¢ao�OQ <br />w�W <br />wwz¢3iZOOa oo0MTz¢w05 <br />u <br />Nw. <br />=cn IZO;,�CWaMwHwFUo(na0wEwcJcccc¢ <br />N <br />rn <br />%0 <br />Q <br />CD C.:D 0 <br />0% <br />E <br />O <br />� <br />-1 <br />O <br />> <br />0 <br />.. N <br />(%% J o <br />a- <br />Jmo <br />Q z <br />=0w <br />a <br />CV)O <br />o <br />C/) <br />N <br />0 <br />= <br />o <br />N <br />G�g <br />w <br />N <br />6= <br />w <br />m <br />2 <br />D <br />z <br />m <br />> <br />2021 CSP <br />ISSUE BLOCK <br />CHECKED BY: <br />KAW <br />DRAWN BY: <br />BMS <br />PROTO: <br />192 <br />PROTO CYCLE: <br />08-27-21 <br />DOCUMENT DATE: <br />10-01-21 <br />Wit 4 <br />.% ,ENS <br />No. 64983 <br />t <br />11 STATE OF 44/ <br />-4 <br />10/05/2021 <br />DOCUMENTS THAT DO NOT <br />HAVE THE ARCHITECT OR <br />ENGINEER OF RECORD SEAL <br />AND SIGNATURE SHALL BE <br />CONSIDERED NOT FOR <br />CONSTRUCTION <br />PHARMACY <br />ELECTRICAL <br />PLANS <br />SHEPHM1 <br />