Laserfiche WebLink
PROVIDE NEW WIR-2020 <br />TO EXISTING EP/2 IN <br />ELECTRICAL ROOM 1 <br />1 2 3 4 5 6 8 9 <br />PROVIDE NEW WIR-2020 REFURBISH <br />FROM NEW RTU TO <br />ELECTRICAL ROOM 1 EXISTING ES1 IN 7 RTU-34 <br />ELECTRICAL ROOM 1- F15.813- I - I 15.813 -I _ <br />REFURBISH <br />RTU-28 <br />15.814 <br />® S-29 <br />- - <br />0 <br />15.814 <br />° I REFURBISH I <br />RTU-30 S-33 <br />'Lc <br />15.814 S-32 REPLACE RTU-33 <br />REPLACE <br />RTU-31 15.817 <br />- - REPLACE 15.817 <br />RTU-29 IAQ REPLACE RTU-32 <br />PROVIDE NEW WIR-2620 = <br />TO EXISTING EP/2 IN <br />ELECTRICAL ROOM 1 <br />ETR <br />AHU-2 <br />REFURBISH <br />RTU-24 <br />REFURBISH <br />I / RTU-21 I I I <br />1 <br />ETR <br />15.813 AHU-1 <br />I <br />I► I I I I <br />i <br />- REPLACE C <br />RTU-13- <br />15.817 <br />REFURBISH <br />RTU-25 <br />i I <br />I I <br />ETR <br />AHU-3 <br />I I <br />0-13 15.817 1 1 1 REFURBISH REFURBISH I REFURBISH <br />RTU-16 RTU-17 RTU-18 <br />I I <br />I I <br />REFURBISH <br />RTU-22 <br />i I <br />REPLACE REPLACE <br />RTU-14 m 13;:. HS-12 RTU-12 <br />OS-12 <br />S-14 "` I ' 15.817 I <br />REPLACE <br />S-15 S_1 15.814 REPLACE REPLACE 15.814 <br />RTU-11 ° <br />RTU-6 RTU-8 <br />10 11 12 13 14 15 <br />REFURBISH <br />RTU-35 <br />I I I I I I <br />_ <br />REFURBISH REPLACE ° <br />RTU-26 RTU-27 27 <br />I I I I I I <br />I I I I I <br />REFURBISH_ - - - - <br />RTU-23 <br />/ 15.814 <br />15.813 I <br />I <br />15.814 <br />I <br />2 I <br />I 115.813 1 1 REFURBISH I <br />3AS2 RTU-20 <br />TYP <br />m REPLACE <br />RTU-19 <br />REPLACE 15.817 _ 15.817 - - - 15.817 15.817 S-11 - - <br />1 RTU-15 4 I I I ° 15.817 <br />15.81 SA 15.817 15.817 S-9 <br />REPLACE 1 <br />15.814 I <br />RTU-1 ° - 0 ° 0 0 <br />\ REPLACE REPLACE <br />REPLAC RTU-2 1IAQ I RTU-7 I 15.813 <br />RTU-4 IAQ S-7 S_g <br />15.813 -- <br />S-2 15.813 , <br />A REFURBISH - REPLACE 3_5 TM REPLACE 15.813 REFURBISH <br />I RTU-3 RTU-5 I I RTU-9 I RTU-10 <br />HVAC BAS PLAN_ <br />1 1" = 30'-0" <br />W <br />w <br />w <br />w <br />a <br />U <br />G7 <br />J <br />w <br />a <br />U <br />PE� <br />r- <br />i <br />TYP <br />i <br />BAS SYMBOLS <br />BAS GENERAL NOTES <br />10.30.15 <br />03.30.18 <br />AHUC <br />AHU CONTROLLER <br />1. BAS CONTRACTOR SHALL INSTALL EACH SENSOR IN <br />SAME LOCATION AS EXISTING OR AS SHOWN ON <br />AHUS# <br />AHU TEM/RH SENSOR <br />PLAN. SENSORS NOTED AS EXISTING TO REMAIN <br />(ETR). BAS CONTRACTOR SHALL VERIFY THAT <br />ALS <br />ANALOG LIGHT SENSOR <br />SENSOR IS OPERATIONAL AND IF NOT, ALERT <br />OWNER CONSTRUCTION MANAGER. <br />2• SENSORS NOTED AS RELOCATED. BAS CONTRACTOR <br />ETM <br />ELECTRONIC THERMOSTAT MODULE <br />IDS <br />INDOOR DEWPOINT SENSOR <br />SHALL INSTALL NEW CABLES, EXTEND CONDUIT AND <br />RECONNECT TO EXISTING UNITS. REFER TO <br />IHS <br />INDOOR HUMIDITY SENSOR <br />MECHANICAL SHEETS FOR LOCATION ON ROOF TOP <br />UNIT LOCATION IF NOT SHOWN ON THIS PLAN. <br />ITS <br />INDOOR TEMPERATURE SENSOR <br />3. TEMPERATURE AND CO2 SENSOR MOUNTING: <br />ODS <br />OUTDOOR DEWPOINT SENSOR <br />PROVIDE 1/2" CONDUIT AND INSTALL BAS CABLE <br />FROM SENSOR TO CONTROL MODULE. MOUNT <br />SENSOR ON BOX. ALL SENSORS TO BE MOUNTED AT <br />OS-X <br />OVERRIDE TEMPERATURE SENSOR <br />+84" UNLESS NOTED OTHERWISE. SENSORS ON <br />SALES FLOOR SHALL BE INSTALLED ON THE BACK <br />OTS <br />OUTDOOR TEMPERATURE SENSOR <br />SIDE OF COLUMN. DO NOT INSTALL SENSORS IN HVAC <br />SUPPLY AIR PATH OR IN DIRECT SUNLIGHT. REF <br />HS-X <br />WALL HUMIDITY SENSOR <br />MECHANICAL DRAWINGS FOR EXACT LOCATIONS. <br />S-X <br />WALL TEMPERATURE SENSOR <br />A. GYPSUM BOARD WALLS: PROVIDE A 4" SQUARE <br />RECESSED BOX WITH A SINGLE GANG PLASTER <br />O <br />UNIT HEATER TEMPERATURE SENSOR <br />RING FLUSH MOUNTED VERTICALLY. <br />B. BLOCK WALLS AND COLUMNS: PROVIDE A 2"X4" <br />BOX SURFACE MOUNTED VERTICALLY. <br />RTUC <br />ROOFTOP UNIT CONTROLLER <br />BAP <br />BUILDING ALARM PANEL <br />C. INSULATE BEHIND SENSORS MOUNTED ON <br />Eg <br />CARBON DIOXIDE SENSOR <br />EXTERIOR WALLS WITH 1/2" POLYSTYRENE <br />SPACER. <br />EP/2 <br />BUILDING BAS CONTROLLER <br />D. MOUNT CO2 SENSORS 6" ABOVE TEMPERATURE <br />SENSORS. <br />ES1 <br />BUILDING EXECUTIVE BAS CONTROLLER <br />4. TERMINATIONS SHALL BE MADE IN ACCORDANCE <br />FDI <br />FLUORESCENT DIMMER INTERFACE <br />WITH BAS SUPPLIER INSTALLATION INSTRUCTIONS. <br />NO FOIL OR UNUSED WIRE(S) SHALL BE EXPOSED <br />HIR <br />HUMIDITY INTERFACE RELAY <br />AFTER APPLICATION OF HEAT SHRINK. <br />IAO <br />INTERFACE ANALOG OUTPUT <br />5. CABLE: PROVIDE CABLE ACCORDING TO DRAWINGS. <br />NO DEVIATION FROM DRAWINGS WILL BE ACCEPTED. <br />IFP <br />INTERFACE PANEL <br />CABLES SHALL HAVE EACH END LABELED INDICATING <br />WHERE THE OPPOSITE END TERMINATES. CABLE <br />IOM <br />INPUT/OUTPUT MODULE <br />SHALL BE INSTALLED IN CONDUIT OR CABLE TRAY IN <br />FINISHED AREAS OF BUILDING. EXCEPT HVAC CABLE <br />IR <br />INTERFACE RELAY <br />IN SALES FLOOR AREA AT BAR JOISTS. <br />6. MINOR CHANGES IN MATERIALS OR TERMINATION <br />CONTACTOR <br />POINTS SHALL NOT INCREASE CONTRACT COST. <br />MINio <br />AHU INTERFACE AND/OR UO MODULE <br />7. ROUTE BAS CONDUITS IN CONCEALED LOCATIONS (IN <br />WALLS, PIPE RACKS AND/OR CHASES). PROVIDE A <br />PLM <br />PHASE LOSS MONITOR <br />TRANSITION FROM THE PVC UNDERSLAB BAS <br />CONDUIT TO EMT OR FLEX. BAS CABLES SHALL BE <br />PSO <br />POWER SWITCHING OVERRIDE PANEL <br />RUN IN CONDUIT FULL LENGTH, BENEATH <br />REFRIGERATED CASES. BAS CABLES AT BAR JOIST <br />PSP <br />POWER SWITCHING PANEL <br />LEVEL IN OPEN SALES AREA AND THE STOCKROOM <br />CAN BE EXPOSED. <br />8. BAS CONDUIT CABLES, AND WIRING SHALL BE <br />ROP <br />REMOTE OVERRIDE PANEL <br />ELDP <br />ECLIPSE LIGHT DIMMING PANEL <br />INSTALLED AND CONNECTED BY BAS CONTRACTOR. <br />THE INSTRUMENT AND SIGNAL CABLES SHALL BE <br />UCM <br />UNITARY CONTROL MODULE <br />ISOLATED AND LOCATED AS FAR AWAY AS POSSIBLE <br />FROM ANY HIGH VOLTAGE CONDUCTORS OR OTHER <br />XCM.20R <br />BUILDING BAS CONTROLLER <br />WIRE RACEWAYS THAT MAY CAUSE <br />ELECTROMAGNETIC INTERFERENCE INCLUDING <br />O <br />NIGHTTIME OVERRIDE SWITCH <br />UNPROTECTED CABLES FIELD ROUTED INSIDE <br />ROOFTOP EQUIPMENT (RTU). REFER TO AND READ <br />QS <br />MOMENTARY PUSH BUTTON SWITCH <br />THE SENSOR MANUFACTURER'S ELECTRICAL <br />INSTALLATION GUIDELINES FOR MORE INFORMATION. <br />OP <br />POTENTIOMETER <br />9. BAS CONTRACTOR SHALL COORDINATE WITH OTHER <br />NEW EQUIPMENT <br />TRADES TO INSTALL ONLY CODE APPROVED <br />PENETRATIONS OF FIRE WALLS. BAS SUPPLIER <br />EXISTING EQUIPMENT <br />RESERVES THE RIGHT TO CHANGE AND/OR MODIFY <br />ANY/ALL COMPONENTS AND TO MAKE CHANGES TO <br />THE EQUIPMENT DESIGN. REFER TO BAS SUPPLIER <br />-BAS EQUIPMENT SALVAGE <br />EQUIPMENT INSTALLATION. INSTRUCTIONS FOR <br />REQUIREMENTSED11.uz-w <br />CURRENT LAYOUT AND CONFIGURATION. <br />10. DEMOLITION: COORDINATE WITH DEMOLITION PLAN <br />ALL DEMOLISHED NOVAR BAS EQUIPMENT SHALL BE <br />NOTES THE EXTENT OF BAS DEMOLITION. REMOVE <br />RETURNED TO OWNER'S CONSTRUCTION MANAGER. <br />CONDUIT AND WIRES ALL THE WAY BACK TO <br />EQUIPMENT TO BE RETURNED INCLUDES: EXECUTIVE <br />ORIGINATING JUNCTION BOXES OR DEVICES. <br />CONTROLLER(S), IOM(S), CIM(S), CCM(S), ETC. <br />DEMOLITION SHALL NOT AFFECT ACTIVE CIRCUITS. <br />PROVIDE DOCUMENTATION FOR ALL EQUIPMENT <br />REMOVED IN ACCORDANCE WITH SPECIFICATIONS <br />11. BAS CONTRACTOR SHALL PROVIDE ASSISTANCE TO <br />AND REQUIRED CLOSE-OUT DOCUMENTS. <br />THE BAS SUPPLIER ON PERFORMING EQUIPMENT <br />TESTS ON POWER SWITCHING PANELS AS <br />NECESSARY. <br />KEYNOTES <br />12. DIMMING CONTROL WIRING MUST TERMINATE IN <br />HOME RUN FIXTURES ONLY, AS SHOWN ON BAS <br />PLANS, PER THE MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS. DO NOT MODIFY THE LISTED <br />FIXTURE'S WIRING HARNESS OR TERMINATE <br />15.813 DISCONNECT AND REMOVE COMM LOOP <br />CONTROL WIRING IN THE ADJACENT FIXTURES. <br />SECTION (SHOWN DASHED) TO PROVIDE TRUE <br />DAISY CHAIN CONNECTION COMPATIBLE WITH <br />13. DO NOT INSTALL EQUIPMENT OR CONDUITS <br />NEW FACTORY INSTALLED RTU CONTROLLERS. <br />DIRECTLY UNDER SKYLIGHT WELLS UNLESS <br />15.814 PROVIDE NEW NOVAR WIR-2020 COMM LOOP <br />INDICATED OTHERWISE ON PLANS. <br />BETWEEN UNITS SHOWN TO COMPLETE TRUE <br />DAISY CHAINED CONNECTION COMPATIBLE WITH <br />14. WHERE GROUPED CONDUITS ARE INSTALLED WITHIN <br />NEW FACTORY INSTALLED RTU CONTROLLERS. <br />THE JOIST SPACE, COORDINATE WITH SPRINKLER <br />15.814A PROVIDE NEW NOVAR WIR-2020 COMM LOOP <br />CONTRACTOR PRIOR TO INSTALLATION IN ORDER TO <br />BETWEEN UNITS SHOWN TO MAINTAIN EXISTING <br />MAINTAIN REQUIRED CLEARANCES FROM <br />COMMUNICATION LOOP WHERE LOOP IS BROKEN <br />SPRINKLERS. <br />DUE TO REMOVAUREPLACEMENT OF EXISTING <br />RTU. <br />15. 24 HOURS PRIOR TO SHUTTING DOWN HVAC <br />15.817 EXISTING COMMUNICATION LOOP TO REMAIN. <br />SYSTEMS OR ENERGY MANAGEMENT CONTROLS <br />SYSEMS, SEND EMAIL TO NSRM@WALMART.COM. <br />THE E-MAIL SHALL STATE WHAT, WHY, AND WHEN IT <br />IS BEING SHUT DOWN AND HOW LONG IT IS <br />ANTICIPATED TO BE SHUT DOWN. THEN SEND A <br />FOLLOW UP EMAIL TO NSRM@WALMART.COM AFTER <br />THE WORK IS COMPLETE AND THE SYSTEM IS BACK <br />UP AND RUNNING. <br />NOTE: ALL WORK ON THIS SHEET IS TO BE <br />COMPLETED BY AN OWNER APPROVED <br />CONTRACTOR <br />EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND <br />EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL <br />MAY NOT REFLECT EXACT "AS -BUILT" CONDITIONS. CONTRACTOR SHALL <br />DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT <br />FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL <br />THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING <br />BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND <br />THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF <br />DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. <br />CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. <br />0 <br />W no WWo0> <br />O y F W m Z H o <br />W W xZLLP I�aW�vo <br />ww <br />O m55 0,1 oW j�Hit <br />a¢ <br />z ¢Q w¢"Fa!vLLwi <br />0 ?�LLLLLLJV 0z0'w 0Fa <br />To �I�n w w ZOZ <br />?� jOo0V590E- w <br />is 20 ow-jwwoow <br />a. Z(zxr o�w_ag�nowog <br />coWn�w►_3F 3Wa: <br />iw0mowZjw=FG7 mnw <br />w <br />aZ <br />0 <br />m <br />0 <br />00 J <br />CO C7 <br />ElD <br />o O <br />cC a <br />O N <br />O c <br />Z o <br />W o <br />Lo <br />0 N <br />0 T H <br />1 fA <br />W <br />N w <br />w <br />m <br />z <br />m <br />0 <br />ISSUE BLOCK <br />CHECKED BY: TDD <br />DRAWN BY: RR <br />DOCUMENT DATE: 06/30/23 <br />THIS ITEM HAS BEEN <br />ELECTRONICALLY SIGNED <br />AND SEALED BY MICHAEL <br />DEAN SCHAEFER ON THE <br />DATE LISTED BELOW <br />USING A DIGITAL <br />SIGNATURE. <br />PRINTED COPIES OF THIS <br />DOCUMENT ARE NOT <br />CONSIDERED SIGNED AND <br />SEALED AND THE <br />SIGNATURE MUST BE <br />VERIFIED ON ANY <br />ELECTRONIC COPIES. <br />MICHAEL D. SCHAEFER <br />LICENSE # 89591 <br />`% 'toj%;11fjt`fno. Boni <br />M <br />•10 <br />'STATE OF <br />��i_i��'•••.tO.•• .tom <br />fJA, , <br />06/30/2023 <br />HVAC <br />BUILDING <br />AUTOMATION <br />SYSTEM PLAN <br />I mO)W@)LJ• <br />6XE BAS1 <br />