Laserfiche WebLink
N <br />MOU <br />O <br />Ali , <br />47 /A <br />a-- E= <br />C.7 NFaJE - - - <br />O <br />u <br />Q <br />0 <br />U <br />(n <br />ELECTRICAL CONDUITS <br />MOUNTED ON UNISTRUT <br />REFRIGERATION SUCTION LINES SPACED <br />8" OC MOUNTED ON UNISTRUT TYP <br />DO NOT ATTACH <br />UNISTRUT TO CASE <br />REFRIGERATED CASE <br />(TYPICAL) <br />BOLTS TO FLOOR ONLY <br />LINE RACKING BEHIND. <br />REFRIGERATED C <br />N TS <br />36'-DX6LN <br />(REPLACE) <br />RECONNECT TO EXISTING <br />REFRIGERATION CIRCUITS WHERE <br />SHOWN. REF REFRIGERATION <br />LEGENDS FOR PIPE SIZE AND <br />VALVE REQUIREMENTS. <br />4 <br />SES <br />09.01.11 <br />REFRIGERATION PLAN11-011 <br />(REPLACE) <br />b <br />RMZC30 <br />REFRIGERATION KEYNOTES <br />09.01.11 <br />DEMOLITION NOTES <br />09.01.11 <br />15.601 SLOPE REFRIGERANT LINES BACK TO 1. <br />THE CONTRACTOR SHALL REMOVE EXISTING REFRIGERATED <br />COMPRESSORS AT 1" PER 20' OF RUN. LOCATE <br />CASES AND EQUIPMENT AS SHOWN ON DEMOLITION PLAN. <br />HIGHEST POINT OF REFRIGERATION LINES JUST <br />PROPERLY PUMP DOWN AND RECYCLE REFRIGERANT. <br />BELOW BOTTOM CHORD OF JOIST OR BEAM. <br />PREPARE FOR DISPOSAL. PROMPTLY HAUL OFF AND <br />COORDINATE ELEVATION TO AVOID CONFLICTS WITH <br />PROPERLY DISPOSE OF AND/OR RECYCLE ALL <br />DUCTWORK, LIGHTING, SKYLIGHTS, ETC. <br />EQUIPMENT REMOVED FROM STORE. <br />1 SUPPORT HORIZONTAL RUNS OF REFRIGERANT 2. <br />WHERE APPLICABLE COOLER PANEL MANUFACTURER <br />LINES ON 1-5/8" x 1-5/8" UNISTRUT <br />SHALL DEMOLISH AND PROMPTLY HAUL OFF WALK-IN <br />CHANNELS ON MAXIMUM OF 10 FOOT CENTERS. <br />PANELS AND DOORS TO BE REPLACED. <br />15.609 PROVIDE PVC DRAIN LINE FROM EACH CASE 3. <br />IMMEDIATE SALVAGE/LEGAL DISPOSAL OF ALL <br />DRAIN CONNECTION SAME SIZE AS CASE OUTLET, <br />DECOMMISSIONED EQUIPMENT SHALL BE THE <br />AND END OVER FLOOR DRAIN W/AIR GAP; PITCH <br />RESPONSIBILITY OF THE CONTRACTOR. AT THE DISCRETION <br />DRAINS 1" PER 10'. PROVIDE DRAIN COVER <br />OF THE WALMART MECHANICAL SERVICES CONSTRUCTION <br />GRATE TO MATCH EXISTING. <br />MANAGER WALMART SHALL RETAIN THE OPTION TO <br />OCCASIONALLY SALVAGE EMS EQUIPMENT, VARIABLE <br />GENERAL PIPING <br />FREQUENCY DRIVE , C, <br />DOORS, E APO ATORQS, REFRIGERATEDRESSORSCASES, EWC.LFROM <br />RE -INSULATION NOTES <br />TO BEDURING <br />CAP-XSRATION PROJJECT.QUNT THES CONTRACTORS PLACED SHALL COORDINATES <br />01.05.12 <br />WITH THE WALMART MECHANICAL SERVICES CONSTRUCTION <br />RE -INSULATION NOTES ARE ONLY APPLICABLE FOR PIPING <br />MANAGER ALL ITEMS TO BE RETAINED BY WALMART PRIOR <br />THAT IS INDICATED ON THE DRAWINGS TO BE RE -INSULATED. <br />TO REMOVAL OF THE EQUIPMENT SHOWN ON THE <br />REFER TO SPECIFICATIONS FOR NEW PIPING INSULATION <br />DEMOLITION PLANS. THE CONTRACTOR SHALL CAREFULLY <br />REQUIREMENTS. <br />REMOVE ANY ITEMS TO BE RETAINED BY WALMART AND <br />DELIVER THOSE ITEMS, READY FOR SHIPMENT, TO THE <br />1. INSULATION SHALL BE EITHER: AEROCEL-SSPT BY <br />WALMART MECHANICAL SERVICES CONSTRUCTION MANAGER. <br />AEROFLEX USA, INC (AVAILABLE IN BLACK OR WHITE) <br />ALL REMOVED ITEMS NOT ALLOCATED FOR SALVAGE BY <br />OR AP ARMAFLEX SS (FOR BLACK) OR AP ARMAFLEX <br />WALMART SHALL BE THE CONTRACTOR'S RESPONSIBILITY <br />WHITE LAPSEAL (FOR WHITE) BOTH BY ARMACELL. <br />TO IMMEDIATELY REMOVE FROM THE JOB SITE AND <br />COLOR INDICATED ON DRAWINGS. IF NO COLOR <br />ARRANGE DISPOSAL IN ACCORDANCE WITH LOCAL CODES. <br />INDICATED AND INSULATION IS CONCEALED FROM <br />PUBLIC VIEW USE BLACK. 4. <br />RECLAIMED REFRIGERANT WILL REMAIN IN THE <br />POSSESSION OF WALMART STORES, INC. ON APPLICABLE <br />2. INSULATION THICKNESS SHALL BE 1" FOR ALL SUCTION <br />PROJECTS INVOLVING GAS CONVERSION. THE CONTRACTOR <br />PIPING EXCEPT FOR LOCATIONS IN FLORIDA. (IN FLORIDA, <br />SHALL ASSIST WALMART IN THE SCHEDULING OF <br />PROVIDE 1-1/2" INSULATION ON ALL SUCTION PIPING <br />APPROPRIATE CYLINDERS FOR THE COLLECTION OF <br />GREATER THAN 1" IN DIAMETER.) INSULATION THICKNESS <br />REFRIGERANTS, WHICH WALMART WILL PROCESS THROUGH <br />SHALL BE 1/2" FOR ALL LIQUID PIPING. INSIDE <br />THEIR VENDOR RECLAMATION PROGRAM, OR USE IN <br />DIAMETER OF INSULATION SHALL MATCH PIPE DIAMETER <br />OTHER WALMART EQUIPMENT, AT THE DISCRETION OF THE <br />TO MINIMIZE AIR GAPS BETWEEN PIPING AND <br />WALMART MECHANICAL SERVICES CONSTRUCTION MANAGER. <br />INSULATION. PROVIDE FACTORY PRE -MANUFACTURED <br />THE CONTRACTOR AND WALMART INSPECTOR MUST <br />FITTINGS AT ALL TRAPS AND ELBOWS. WHERE <br />RECORD THE USAGE OR DECOMMISSIONING OF THE <br />PRE -MANUFACTURED FITTINGS ARE UNAVAILABLE, MITER <br />REFRIGERANT IN THE REFRIGERANT LOGS AT THE <br />CUT ALL FITTINGS TO ENSURE PROPER SEAL BETWEEN <br />COMPRESSOR RACKS. <br />INSULATION SEGMENTS. IF LOCAL CODE CALLS FOR <br />THICKER INSULATION, COMPLY WITH LOCAL CODE. REFER <br />TO REFRIGERATION LEGENDS FOR EXISTING PIPE SIZES <br />AND APPROXIMATE LENGTHS. <br />GENERAL NOTES <br />3. REPLACE PVC PIPE SLEEVES ON EXISTING HORIZONTAL <br />09.0111 <br />TRAPEZE -TYPE SUPPORTS WITH NEW PVC SLEEVES OF <br />ADEQUATE SIZE TO ACCOMMODATE NEW INSULATION 1. <br />REFER TO DEMOLITION PLANS FOR ADDITIONAL <br />THICKNESS. COORDINATE WITH WALMART MECHANICAL <br />DEMOLITION, REPAIRS, OR CONSTRUCTION OF <br />SERVICES CONSTRUCTION MANAGER TO EXTENT OF <br />REFRIGERATION EQUIPMENT. <br />SLEEVE REPLACEMENT. <br />2. <br />PLAN INDICATES GENERAL ROUTING OF REFRIGERANT <br />4. PUMP DOWN, DEFROST, AND CLEAN OLD COPPER <br />LINES, WITH A SINGLE LINE SHOWN INDICATING BOTH <br />BEFORE RE -INSULATING. IF POSSIBLE, DO NOT CUT <br />SUCTION AND LIQUID LINE ROUTING FOR EACH SYSTEM. <br />ANY COPPER. CONTACT WALMART MECHANICAL SERVICES <br />CONSTRUCTION MANAGER IF COPPER MUST BE CUT. 3. <br />REFRIGERATION SYSTEM INSTALLATION SHALL BE IN <br />COMPLETE CONFORMANCE WITH SPECIFICATIONS, AND <br />5. INSTALL WITH VAPOR STOPS EVERY 18' OF INSULATION <br />WITH ALL REQUIREMENTS OF REFRIGERATION EQUIPMENT <br />RUN. (GLUE INSULATION TO PIPE BY APPLYING A 2" <br />MANUFACTURER. <br />BAND OF INSULATION ADHESIVE TO THE COPPER PIPING <br />EVERY 18'). KEEP HORIZONTAL SEAMS AT OR NEAR 12 4. <br />REFRIGERATION DRAWINGS ARE PROVIDED AS AN AID TO <br />O'CLOCK POSITION. INSTALL PIPE INSULATION IN STRICT <br />BIDDERS AND TO INDICATE DESIRED ROUTING OF <br />ACCORDANCE WITH MANUFACTURERS INSTALLATION <br />REFRIGERATION LINES; CONTRACTOR SHALL ASSUME <br />INSTRUCTIONS. <br />FULL RESPONSIBILITY FOR CORRECT INSTALLATION OF <br />PIPING AND ACCESSORIES TO PROVIDE A COMPLETE <br />6. FREEZER WALK-INS AND LOW TEMP CASE <br />AND FULLY OPERATING SYSTEM. <br />PENETRATIONS REQUIRE THE OPENING TO BE FOAM <br />SEALED AND TRIMMED FLUSH, THEN COATED WITH 5. <br />CONTRACTOR SHALL COORDINATE REFRIGERATION <br />SILICONE SEALANT. <br />DEMOLITION ISSUES WITH THE FIXTURE DRAWINGS. <br />REFER TO FIXTURE PLANS FOR REFRIGERATION <br />7. PROVIDE WHITE 0.20" THICK PVC JACKETING ON ALL <br />EQUIPMENT DEMOLITION AND COOLER REPAIR AND <br />EXPOSED INSULATION WITHIN PREP AREAS. <br />REMODELING. <br />6. <br />REFRIGERATION SYSTEM SHALL REMAIN OPERATIONAL <br />DURING REMODELING. CONTRACTOR SHALL COORDINATE <br />INSTALLATION OF THE NEW EQUIPMENT WITH THE <br />WALMART MECHANICAL SERVICES CONSTRUCTION <br />• <br />MANAGER. DURING THE PHASING OF OLD TO NEW <br />SYSTEMS, BOTH NEW AND OLD REFRIGERATION SYSTEMS <br />— <br />MAY BE REQUIRED TO OPERATE AT THE SAME TIME FOR <br />A SHORT PERIOD. <br />7. <br />CONTRACTOR SHALL REPLACE CORRESPONDING RACK <br />SUCTION CORES AND OIL FILTER FOR ANY <br />SYSTEM/REFRIGERATION CIRCUIT OPENED DURING <br />PROJECT. <br />8. <br />PROVIDE REFRIGERATION CIRCUIT IDENTIFICATION TAG, <br />OF 2" BY 3" ENGRAVED PLASTIC, AT EACH <br />REFRIGERATED CASE AND WALK-IN EVAPORATOR. REF <br />SPECIFICATIONS. <br />9. <br />AT WALMART MECHANICAL SERVICES CONSTRUCTION <br />MANAGER'S OPTION, EXISTING REFRIGERATION PIPING <br />— <br />MAY BE RE -USED. REF REFRIGERATION LEGENDS FOR <br />PIPE SIZE REQUIREMENTS. <br />EXISTING CONDITIONS WERE TAKEN <br />EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING <br />FROM ORIGINAL DRAWINGS AND MAY <br />A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br />NOT REFLECT EXACT "AS -BUILT" <br />SPECIFICATIONS IN THEIR RELATED FIELD. THE <br />CONDITIONS. CONTRACTOR SHALL <br />FAILURE TO ACQUAINT HIMSELF WITH THIS <br />FIELD VERIFY ALL EXISTING CONDITIONS <br />KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY <br />PRIOR TO SUBMITTING FINAL BIDS. <br />OF PERFORMING HIS WORK PROPERLY. NO <br />NOTE: ALL WORK ON THIS SHEET IS <br />CONTRACTOR SHALL CAREFULLY <br />ADDITIONAL COMPENSATION SHALL BE ALLOWED <br />TO BE COMPLETED BY WALMART <br />APPROVED CONTRACTOR. COORDINATE NEW WORK AND <br />BECAUSE OF CONDITIONS THAT OCCUR DUE <br />DEMOLITION WITH ALL OTHER <br />TO FAILURE TO FAMILIARIZE WORKERS WITH THIS <br />DISCIPLINES AND EXISTING CONDITIONS. KNOWLEDGE. <br />In } <br />W Z)V 0ww0z <br />(n crJ(N r r ¢U� ¢��O <br />QW r 3 z W r w Q <br />W o=FZ¢¢a<a>Uw'o <br />o <br />was¢ � zw <br />¢ N} N p O N O 2 Z¢ N Q <br />0 Wry\W 00 <br />r2J WwF-ZOWJ <br />LL_ a¢�o"Nra�¢: Xw <br />N� O \� U D Q� <br />O 3�nQz0'ww�Zaofro <br />w Z O U�� w w O <br />F— zmaowa�ov��orz� <br />Q �w:2Hm, ww.�wwrNL,N< <br />�vaizo�wFzr�wc�rZ <br />cl O (j)� WUWwZU <br />F- ¢ U w w W W- d Z <br />�rw <br />H0LL(nZ0-1Xaaw0am <br />ISSUE BLOCK <br />CHECKED BY: RDF/JAL <br />DRAWN BY: ASM <br />DOCUMENT DATE: 01 /03/12 <br />REFRIGERATION <br />PLAN AND <br />DETAIL <br />SHEET: <br />R1 <br />