Laserfiche WebLink
GRAPHICS SYMBOLS LEGEND <br />GENERAL PLAN SYMBOLS CEILING / LIGHTING SYMBOLS POWER / COMMUNICATION SYMBOLS <br />EXISTING PARTITION TO CEILING MOUNTED EXIT <br />REMAIN SIGN WALL DUPLEX OUTLET <br />EXISTING PARTITION TO SPRINKLER WALL QUAD OUTLET <br />T - - BE REMOVED X <br />X <br />EXISTING DOOR TO sp; SPEAKER WALL DUPLEX - <br />REMAIN `-' DEDICATED <br />X <br />EXISTING DOOR TO BE O CAMERA WALL TELE-DATA - <br />�.� REMOVED C X SINGLE <br />ROUND RECESSED WALL TELE-DATA - DUAL <br />NEW DOOR OX FIXTURE X <br />-� SQUARE RECESSED WALL TELEPHONE <br />X FIXTURE X <br />INTERIOR PARTITION <br />n SQUARE RECESSED oX FLOOR DUPLEX OUTLET <br />v <br />TOP / B OT.O ELEVATION MARKER X WALL -WASH FIXTURE <br />PARTITION TAG `�" X PENDANT FIXTURE OX FLOOR QUAD OUTLET <br />f WALL MOUNTED FIXTURE AV FLOOR AV OUTLET <br />ROOM NAME X X <br />NUMBERI-� ROOM TAG UNDER -CABINET X <br />F------ s CQ WALL JUNCTION BOX <br />X FIXTURE <br />1 KEYNOTE TAG 2X4 LED FIXTURE JIQ FLOOR JUNCTION BOX <br />X X <br />UMBE DOOR TAG FLOOR TELE-DATA - <br />X 1X4 LED FIXTURE *X SINGLE <br />P WINDOW/ GLAZING TAG ® FLOOR TELE-DATA - <br />®X FLOOR <br />X 2X2 LED FIXTURE <br />RX REQUEST TO EXIT <br />X BUTTON <br />EXTERIOR ELEVATION TAG <br />A-X.X <br />UTILITY STRIP FIXTURE M� MOTION SENSOR <br />X SURFACE MOUNTED <br />EMERGENCY FIXTURE ® MAGNETIC LOCK <br />X A-X.X X X INTERIOR ELEVATION TAG <br />ACCESS PANEL CARD READER <br />� <br />i <br />ES ELECTRIC STRIKE <br />L,( X SECTION TAG <br />A-X.X <br />SUPPLY GRILLE EH ELECTRIC HINGE <br />X EL ELECTRIC LOCK <br />A-X.X <br />'~I DETAIL TAGS HT AV WALL AV OUTLET <br />XX RETURN GRILLE <br />�.�. A-X.X HTC AV WALL AV CONTROL <br />SIM PANEL <br />ALIGN EXHAUST FAN HTa- WALL CABLE OUTLET <br />ALIGN TO ESTABLISHED ❑O <br />SURFACES <br />EQUIPMENT TAG <br />FIRE SAFETY SYMBOLS <br />TYPE CEILING TAG R FIRE ALARM PULL STATION <br />NEIGH <br />FINISH w FIRE ALARM STROBE <br />WALL FINISH TAG <br />BASE FIRE ALARM <br />FLOOR IN411 HORN/STROBE <br />�J PATTERN / GRAIN © FIRE ALARM PHONE <br />DIRECTION <br />MATERIAL TRANSITION FEC FIRE EXTINGUISHER <br />CABINET <br />FE FIRE EXTINGUISHER <br />CANISTER <br />REVISION BUBBLE <br />so SMOKE DETECTOR <br />REVISION DELTA HEAT DETECTOR <br />NOT IN CONTRACT <br />WOOD BLOCKING <br />OR SHIM <br />WOOD FRAMING <br />-CONTINUOUS <br />FINISHED <br />WOOD <br />BATT INSULATION <br />i <br />SEMI -RIGID <br />INSULATION - FIRE <br />SAFING <br />RIGID <br />INSULATION <br />SPRAY -ON FIRE <br />SAFING OR <br />INSULATION <br />COMPRESSIBLE <br />FILLER <br />CERAMIC TILE <br />PLASTER WITH <br />METAL LATH <br />GYPSUM BOARD <br />FINISH <br />WOOD FLOORING <br />TERRAZZO FINISH <br />I <br />CARPET & PAD , <br />i <br />1. <br />THE WORK SHALL CONFORM TO THE APPLICABLE BUILDING CODE AND OTHER <br />CONSTRUED AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE, AND <br />40. <br />THE CONTRACTOR SHALL CONFIRM THE AVAILABILITY AND DELIVERY TIMES <br />ORDINANCES, CODES AND REGULATIONS LISTED IN THE SPECIFICATIONS OR <br />LATER CLAIMS WILL NOT BE RECOGNIZED FOR EXTRA LABOR, EQUIPMENT, OR <br />FOR ALL SPECIFIED MATERIALS & EQUIPMENT REQUIRED TO PERFORM THE <br />ON THE DRAWINGS, AND REQUIRED BY LOCAL BUILDING AUTHORITIES. THE <br />MATERIALS, REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WHICH <br />WORK UPON RECEIPT OF THE CONTRACT DOCUMENTS. SHOULD THE <br />GOVERNING CODES, RULES AND REGULATIONS ARE COLLECTIVELY REFERRED <br />COULD HAVE BEEN REASONABLY FORESEEN HAD SUCH AN EXAMINATION BEEN <br />AVAILABILITY OF SPECIFIED ITEMS POSE A DELAY TO THE ON -TIME <br />TO AS "THE CODE." THE CONTRACTOR SHALL REPORT ANY INCONSISTENCIES, <br />MADE. THE GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AND <br />COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL NOTIFY THE <br />CONFLICTS OR OMISSIONS DISCOVERED TO THE ARCHITECT FOR <br />DIMENSIONS ON THE JOB SITE AND REPORT ANY AND ALL DISCREPANCIES <br />ARCHITECT IMMEDIATELY AND PROPOSE AN EQUIVALENT SUBSTITUTION TO <br />INTERPRETATION PRIOR TO PERFORMING THE WORK. <br />AND/OR UNUSUAL CONDITIONS TO THE ARCHITECT PRIOR TO FINALIZING <br />BE REVIEWED BY THE ARCHITECT IF SUCH A DELAY IS NOT ACCEPTABLE. <br />BIDS OR COMMENCEMENT OF ANY CONSTRUCTION. <br />2. <br />WHERE APPLICABLE TO PROJECT SCOPE, THE GENERAL CONTRACTOR SHALL <br />41. <br />SUBSTITUTION OF ALL "EQUALS" SHALL BE ONLY AS APPROVED BY THE <br />CONTACT BUILDING MANAGEMENT TO DETERMINE THE RULES OF THE <br />16. <br />THE GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS <br />ARCHITECT. WHERE THE TERM "OR EQUAL" IS USED THE ARCHITECT SHALL BE <br />BUILDING RELATIVE TO CONSTRUCTION; WHEN AND HOW DELIVERIES CAN BE <br />ON THE JOB SITE AND REPORT ANY AND ALL DISCREPANCIES AND/OR <br />THE SOLE JUDGE OF EQUALITY BASED UPON THE INFORMATION FURNISHED <br />MADE, WHAT PHASES AND TYPES OF CONSTRUCTION MAY BE DONE ON <br />UNUSUAL OR HIDDEN CONDITIONS TO THE ARCHITECT PRIOR TO FINALIZING <br />BY THE CONTRACTOR. SUBSTITUTIONS MUST BE ACCEPTED IN WRITING <br />REGULAR OR OVERTIME BASIS, AND IN GENERAL ANY SPECIAL BUILDING <br />BIDS OR COMMENCEMENT OF ANY CONSTRUCTION. THE GENERAL <br />BEFORE THEY MAY BE USED. <br />REQUIREMENTS WHICH WILL AFFECT THE COST OF ALL WORK BORNE BY THE <br />CONTRACTOR SHALL MAKE KNOWN ANY AND ALL LIMITATIONS, EXCLUSIONS, <br />GENERAL CONTRACTOR. ALL WORK SHALL CONFORM TO ALL BASE BUILDING <br />OR MODIFICATIONS TO THE PROJECT DURING THE BID SELECTIONS PERIOD. <br />42. <br />THE CONTRACTOR SHALL PREPARE SUBMITTALS FOR REVIEW BY THE <br />STANDARD SPECIFICATIONS AND BUILDING REGULATIONS, WHICH THE <br />ANY AND ALL LIMITATIONS, EXCLUSIONS, OR MODIFICATIONS NOT ITEMIZED <br />ARCHITECT, FOR ALL MATERIALS AND EQUIPMENT SPECIFIED. IF THE <br />CONTRACTOR SHALL OBTAIN PRIOR TO SUBMISSION OF BID. <br />IN THE BID PROPOSAL DOCUMENTS ARE PRESUMED "INCLUDED", IN WHICH <br />CONTRACTOR, THE OWNER, OR THE OWNER'S REPRESENTATIVE SUBSTITUTES <br />CASE NO ADDITIONAL MONIES WILL BE ALLOCATED FOR THIS WORK. <br />A MATERIAL, METHOD OF ATTACHMENT, REVISES A CONSTRUCTION DETAIL, <br />3. <br />THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE <br />OR IN ANY WAY ALTERS THE WORK SUCH THAT IT NO LONGER CONFORMS TO <br />SUB -CONTRACTORS' RECEIPT OF COMPLETE SETS OF CONSTRUCTION <br />17. <br />ALL WORK COSTS SUBMITTED FOR THIS PROJECT ARE FURNISHED WITHOUT <br />THESE DOCUMENTS, WITHOUT THE WRITTEN ACCEPTANCE OF THE <br />DOCUMENTS, AS WELL AS ALL FUTURE ADDENDA, BULLETINS, FIELD <br />OBLIGATION; THE CLIENT RESERVES THE RIGHT TO ACCEPT OR REJECT ANY <br />ARCHITECT, SUCH ACTION WILL RELIEVE THE ARCHITECT OF ANY <br />DIRECTIVES AND CHANGE ORDERS. <br />PROPOSAL OR PART OF ANY COST SUBMITTED. <br />RESPONSIBILITY OR LIABILITY INCLUDING, BUT NOT LIMITED TO, AESTHETIC <br />CONSEQUENCES, SUBSEQUENT FAILURES) AND PERSONAL OR PROPERTY <br />4. <br />THE CONTRACTOR SHALL COORDINATE THE STORAGE OF MATERIALS AND <br />18. <br />WHERE APPLICABLE TO PROJECT SCOPE, EXISTING CONSTRUCTION AND <br />DAMAGE ATTRIBUTABLE TO THIS CHANGE. <br />SHALL PROVIDE PROTECTION AS NECESSARY TO PREVENT VANDALISM AND <br />DIMENSIONS SHOWN ARE PER EXISTING DRAWINGS. ALL EXISTING <br />LOSS OF MATERIALS BY THEFT OR DAMAGE SUSTAINED DUE TO EXPOSURE TO <br />INFORMATION MUST BE VERIFIED IN THE FIELD. NEITHER THE OWNER NOR <br />43. <br />REVIEW OF A SPECIFIC ITEM SHALL NOT CONSTITUTE A REVIEW OF AN <br />INAPPROPRIATE ENVIRONMENTAL CONDITIONS AND WILL REPAIR & REPLACE <br />THE ARCHITECTS ARE RESPONSIBLE FOR ACCURACY OF EXISTING <br />ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. <br />DAMAGE OR LOSSES AT THE CONTRACTOR'S EXPENSE WITHOUT CHARGE TO <br />INFORMATION. EXISTING CONSTRUCTION CONDITIONS IN AREAS WHERE NEW <br />THE OWNER. <br />WORK IS NOT PLANNED MAY BE NOT COMPLETELY SHOWN. <br />44. <br />SUBMITTALS THAT CONTAIN EXCESSIVE ERRORS OR ARE INCOMPLETE OR <br />INADEQUATE MAY BE RETURNED WITHOUT ACTION. COSTS INCURRED FOR <br />5. <br />WHERE ADJACENT AREAS BEYOND THE IMMEDIATE CONSTRUCTION AREA WILL <br />19. <br />WITHIN ONE (1) WEEK (5 BUSINESS DAYS), OF THE AWARD OF THIS <br />THE RESULTANT DELAYS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. <br />BE OCCUPIED DURING THE CONSTRUCTION PERIOD, THE CONTRACTOR SHALL: <br />CONTRACT, PRIOR TO MOBILIZATION FOR ANY WORK, THE CONTRACTOR <br />A. CONFORM TO OWNERS AND TENANT REQUIREMENTS FOR HOURS OF <br />SHALL FURNISH A CONSTRUCTION SCHEDULE SHOWING CHRONOLOGICALLY <br />45. <br />REVIEW OF SUBMITTALS SHALL NOT RELIEVE THE CONTRACTOR OF <br />CONSTRUCTION OPERATIONS, ACCESS TO TENANT SPACES AND <br />THE PHASES OF THE WORK, AND ALL RELATED WORK FOR THE COMPLETION <br />OBLIGATIONS OR RESPONSIBILITIES FOR DEVIATIONS FROM THE <br />ALLOWABLE NOISE LEVEL DURING TENANT BUSINESS HOURS, <br />OF THE PROJECT. THIS SCHEDULE SHALL INDICATE ALL ORDERING LEAD <br />REQUIREMENTS OF THESE CONTRACT DOCUMENTS, UNLESS THE ARCHITECT <br />B. CONSTRUCTION OPERATIONS SHALL NOT BLOCK HALLWAYS ACCESSIBLE <br />TIMES, LENGTH OF TIME FOR EACH PHASE, ITS START AND COMPLETION, <br />IS NOTIFIED, AND SPECIFICALLY APPROVES, OF THE DEVIATIONS AT THE TIME <br />ROUTES OR MEANS OF EGRESS FOR TENANTS OF BUILDING. <br />WITH A PROJECTED COMPLETION DATE. <br />OF SUBMISSION. <br />C. CONSTRUCTION OPERATIONS SHALL NOT CAUSE INTERRUPTIONS OF <br />ELECTRICAL SERVICES TO THE TENANTS OF THE BUILDING WITHOUT <br />20. <br />CONTRACTOR AND SUBCONTRACTORS SHALL ATTEND JOB MEETINGS <br />46. <br />REVIEW OF SUBMITTALS SHALL NOT RELIEVE THE CONTRACTOR'S OBLIGATION <br />PRIOR NOTIFICATION AND APPROVALS. PROPERLY PROTECT ALL FLOORS, <br />REQUIRED BY THIS CONTRACT. <br />FOR COORDINATION NOR WAIVE RESPONSIBILITY FOR ERRORS AND <br />MAIL CHUTES AND STAIR DOORS IN PUBLIC AREAS SUBJECT TO <br />OMISSIONS IN THE SUBMITTALS, INCLUDING "FIELD MEASURE." <br />CONSTRUCTION TRAFFIC. SHOE WIPING MATS WILL BE INSTALLED AT ALL <br />21. <br />THE CONTRACTOR SHALL OBTAIN ALL PERMITS FOR ALL SITE DEVELOPMENT <br />OPENINGS BETWEEN CONSTRUCTION AREAS AND ALL PUBLIC SPACES. ALL <br />WORK, PAY ALL FEES FOR PERMITS AND CHECK ALL GOVERNING AUTHORITIES' <br />47. <br />CHANGES IN THE SCOPE OF WORK OR IN CONSTRUCTION DETAILS, WHETHER <br />ACTIVE AREAS SHALL BE KEPT CLEAN AND FREE FROM DEBRIS. <br />SPECIFICATIONS FOR BUT NOT LIMITED TO, GUTTERS, SIDEWALKS, POLES, <br />DUE TO FIELD CONDITIONS OR OMISSIONS BY THE CONTRACTOR, ARCHITECT <br />D. ERECT AND MAINTAIN TEMPORARY BRACING, LIGHTS, DUSTPROOF <br />AND OTHER STRUCTURES, INCLUDING THE REMOVAL OR RELOCATION OF <br />OR OWNER, SHALL BE DOCUMENTED BY THE ARCHITECT AND APPROVED, <br />PARTITIONS, BARRICADES, FENCES AND WARNING SIGNS AS NECESSARY <br />EXISTING UTILITIES OR OTHER PHYSICAL OBJECTS SHOWN ON PLANS OR <br />PRIOR TO EXECUTION. <br />TO PREVENT INJURY, NOISE, DUST AND INCONVENIENCE TO OTHER <br />NOTED OTHERWISE. <br />TENANTS, THE PUBLIC, AND TO PREVENT DAMAGE TO ADJACENT <br />48. <br />SHOULD THE GENERAL CONTRACTOR CLAIM THAT AN ISSUE, DIRECTED <br />CONSTRUCTION WHICH IS TO BE LEFT IN PLACE. <br />22. <br />CREATE AND IMPLEMENT AN EROSION AND SEDIMENTATION CONTROL PLAN <br />REVISION, OR CHANGE TO THE ORIGINAL CONTRACT INVOLVES ADDITIONAL <br />E. CONTRACTOR SHALL FOLLOW THE RECOMMENDED CONTROL MEASURES <br />FOR ALL SITE CONSTRUCTION ACTIVITIES ASSOCIATED WITH THE PROJECT. <br />COST UNDER HIS CONTRACT, HE SHALL GIVE WRITTEN NOTICE WITHIN A <br />OF THE SHEET METAL AND AIR CONDITIONING NATIONAL CONTRACTORS <br />THE PLAN MUST CONFORM TO THE EROSION AND SEDIMENTATION <br />PERIOD OF NOT MORE THAN THREE (3) WEEKS (15 BUSINESS DAYS), BUT <br />ASSOCIATION (SMACNA) IAQ GUIDELINES FOR OCCUPIED BUILDINGS <br />REQUIREMENTS OF THE 2003 EPA CONSTRUCTION GENERAL PERMIT OR LOCAL <br />SHALL NOT PROCEED TO EXECUTE THE WORK UNTIL WRITTEN APPROVAL FOR <br />UNDER CONSTRUCTION, 2ND EDITION 2007, ANSI/SMACNA 008-2008 <br />STANDARDS AND CODES, WHICHEVER IS MORE STRINGENT. <br />THE CHANGE REQUEST IS RECEIVED. NO SUCH CLAIMS WILL BE VALID UNLESS <br />(CHAPTER 3). PROTECT STORED ON -SITE AND INSTALLED ABSORPTIVE <br />SO MADE. NO PAYMENT FOR SUCH CLAIMS WILL BE MADE UNTIL FINAL <br />MATERIALS FROM MOISTURE DAMAGE. <br />23. <br />ALL REQUIRED PERMITS MUST BE OBTAINED FROM ALL APPLICABLE <br />SETTLEMENT. <br />F. IF PERMANENTLY INSTALLED AIR HANDLERS ARE USED DURING <br />AUTHORITIES HAVING JURISDICTION PRIOR TO START OF CONSTRUCTION. <br />CONSTRUCTION, FILTRATION MEDIA WITH A MINIMUM EFFICIENCY <br />49. <br />ALL CLAIMS FOR ADDITIONAL WORK WILL BE SUBMITTED IN WRITING FOR <br />REPORTING VALUE (MERV) OF 8 MUST BE USED AT EACH RETURN AIR <br />24. <br />ALL COSTS FOR INSPECTIONS AND/OR TESTS SHALL BE THE RESPONSIBILITY <br />THE CLIENT'S APPROVAL. THE CONTRACTOR SHALL INCLUDE A COMPLETE <br />GRILLE. <br />OF THE CONTRACTOR, U.N.O. <br />NARRATIVE DESCRIPTION OF THE WORK TO BE PERFORMED AS WELL AS <br />MATERIALS TO BE USED, THE AREA OR SPACE BEING WORKED IN, AND UNDER <br />6. <br />AS APPLICABLE TO PROJECT SCOPE, ALL CUTTING, CHASING, DRILLING OR <br />25. <br />THE GENERAL CONTRACTOR SHALL PAY THE EXPENSES FOR ALL <br />WHOSE AUTHORIZATION THE WORK TO BE PERFORMED WAS INITIATED. <br />DEMOLITION OF WALLS, SLABS, ETC. REQUIRING THE USE OF JACKHAMMERS <br />TRANSPORTATION, HOISTING AND ELEVATOR USE CHARGES ON ALL <br />OR OTHER HEAVY HAND OR POWER TOOLS SHALL BE PERFORMED AFTER <br />MATERIALS OR EQUIPMENT TO THE POINT OF USE, AND SHALL BE <br />50. <br />THE PRESENCE OF A REPRESENTATIVE OF THE ARCHITECT ON THE JOB SITE <br />REGULAR BUSINESS HOURS ON AN OVERTIME BASIS IF NECESSARY, UNLESS <br />RESPONSIBLE FOR ALL UNLOADING, CHECKING AND STORAGE OF THE SAME IN <br />DOES NOT IMPLY CONCURRENCE WITH OR THE APPROVAL OF ANY WORK. THE <br />THE BUILDING MANAGEMENT AND ANY AFFECTED TENANTS PROVIDE A <br />CONNECTION WITH THIS CONTRACT. <br />CONTRACTOR SHALL CALL TO THE ATTENTION OF THE ARCHITECT, IN <br />WRITTEN WAIVER EXPRESSLY PERMITTING OTHERWISE. <br />WRITING, ALL SPECIFIC ITEMS FOR WHICH ARCHITECT'S REVIEW IS <br />26. <br />THE CONTRACTOR SHALL MAKE ALL ARRANGEMENTS, MAINTAIN AND PAY ALL <br />REQUIRED. <br />7. <br />THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR <br />COSTS FOR TEMPORARY WATER, PLUMBING, POWER, LIGHTING, HEATING OR <br />JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS <br />VENTILATION REQUIRED TO PROPERLY CONDUCT THE WORK. <br />51. <br />UPON SUBSTANTIAL COMPLETION OF WORK THE CONTRACTOR SHALL <br />PROJECT INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS <br />PREPARE A "PUNCHLIST" OF CORRECTIONS AND UNSATISFACTORY AND/OR <br />REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO <br />27. <br />DO NOT SCALE THESE DRAWINGS; WRITTEN DIMENSIONS SHALL GOVERN. <br />INCOMPLETE WORK FOR REVIEW BY THE ARCHITECT. <br />NORMAL WORKING HOURS. THE CONTRACTOR SHALL PROVIDE PUBLIC <br />SHOULD ANY DIMENSIONAL DISCREPANCIES BE ENCOUNTERED, <br />PROTECTION, AS NECESSARY AND REQUIRED BY GOVERNING AGENCIES <br />CLARIFICATIONS SHALL BE OBTAINED FROM THE OFFICE OF THE ARCHITECT. <br />52. <br />THE CONTRACTOR SHALL MAINTAIN AT THE SITE, ONE RECORD COPY OF ALL <br />HAVING JURISDICTION, UNTIL CLIENT ACCEPTANCE OF THE PREMISES. <br />DRAWINGS, PERMITS, SUBMITTALS AND SAMPLES ON WHICH TO RECORD ALL <br />28. <br />LARGE SCALE DETAILS SHALL GOVERN OVER SMALLER SCALE PLANS AND <br />CHANGES DURING CONSTRUCTION. ACCESS TO THESE SHALL BE PROVIDED <br />8. <br />THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR THE PROVISION <br />ELEVATIONS. INFORM ARCHITECT OF DISCREPANCIES PRIOR TO PROCEEDING <br />FOR THE USE OF ALL TRADES, CLIENT REPRESENTATIVES AND THE <br />AND MAINTENANCE OF ALL BRACING, SHORING, ENCLOSURES, BARRIERS OR <br />WITH WORK. <br />ARCHITECT, DURING ALL PHASES OF CONSTRUCTION. <br />SCAFFOLDING REQUIRED TO PROVIDE A SAFE WORKING ENVIRONMENT AS <br />DICTATED BY SITE CONDITIONS AND THE PROGRESS OF WORK. <br />29. <br />INSTALL ALL EQUIPMENT AND MATERIALS PER MANUFACTURERS' <br />53. <br />DURING THE COURSE OF CONSTRUCTION, ACTUAL LOCATIONS SHALL BE <br />RECOMMENDATIONS. ANY DIFFICULTIES ARE TO BE REPORTED TO THE <br />INDICATED TO SCALE IN RED INK ON THE OWNERS RECORD DRAWINGS FOR <br />9. <br />WHERE APPLICABLE BY PROJECT SCOPE, DURING THE ENTIRE CONSTRUCTION <br />ARCHITECT IMMEDIATELY. <br />ALL RUNS OF MECHANICAL AND ELECTRICAL WORK INCLUDING CONCEALED <br />PERIOD, ALL EXITS, EXIT LIGHTING, FIRE PROTECTION DEVICES AND ALARMS <br />WORK WHICH DEVIATES FROM THE DRAWINGS. UPON COMPLETION OF THE <br />SHALL BE CONTINUOUSLY MAINTAINED IN CONFORMANCE WITH LOCAL <br />30. <br />THE CONTRACTOR AND EACH SUBCONTRACTOR SHALL WARRANTEE ALL WORK <br />PROJECT, INCLUDING ALL PUNCH -LIST ITEMS, THIS INFORMATION SHALL BE <br />BUILDING CODE AND OTHER GOVERNING ENTITY REQUIREMENTS. U.N.O., ALL <br />PERFORMED FOR A MINIMUM PERIOD OF ONE (1) YEAR AS SPECIFIED IN THE <br />NEATLY TRANSFERRED BY THE CONTRACTOR TO A SET OF DRAWINGS, WHICH <br />EXISTING, SERVICES AND DEVICES SHALL REMAIN ACTIVE. <br />CONSTRUCTION CONTRACT. ALL DEFECTS OCCURRING IN THE WARRANTEE <br />SHALL BE MARKED "AS BUILT SET" AND COPIES SHALL BE PROVIDED TO BOTH <br />PERIOD SHALL BE CORRECTED AT NO ADDITIONAL COST.. <br />THE OWNER AND THE ARCHITECT. WITHIN THREE (3) WEEKS (15 BUSINESS <br />10. <br />THE CONTRACTOR SHALL PROTECT THE PROPERTY OF THE CLIENT AND THE <br />DAYS) OF THE RECEIPT OF THE "AS BUILT SET," APPROVAL FOR FINAL <br />BUILDING OWNER. INCLUDING, BUT NOT LIMITED TO, WINDOWS, FLOOR AND <br />31. <br />THE CLIENT, ARCHITECT, CONSULTANTS AND ALL INSPECTORS FROM <br />PAYMENT TO THE CONTRACTOR SHALL BE GRANTED OR REASONABLE CAUSE <br />CEILING FINISHES, PUBLIC TOILETS, ELEVATORS, DOORS & BUCKS, <br />PERTINENT AGENCIES SHALL BE PERMITTED ACCESS TO THE JOB SITE AT ALL <br />SHOWN WHY SUCH APPROVAL HAS BEEN DENIED. <br />ELECTRICAL AND AIR-CONDITIONING EQUIPMENT. THE CONTRACTOR SHALL <br />TIMES DURING NORMAL WORKING HOURS. <br />PROTECT ADJOINING PROPERTY. DAMAGE CAUSED BY THE CONTRACTOR'S <br />54. <br />PRIOR TO THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL <br />WORK OR WORKMEN MUST BE MADE GOOD, IN A TIMELY FASHION. PATCHING <br />32. <br />THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT <br />ASSEMBLE AND FURNISH THE CLIENT A COMPLETE SET OF MANUFACTURERS' <br />AND REPLACEMENT OF DAMAGED WORK SHALL BE PERFORMED AT THE COST <br />NECESSARY TO EXECUTE ALL WORK, EXCEPT WHERE NOTED AS NOT IN <br />CATALOG, OPERATING INSTRUCTIONS, START-UP CHECK LISTS, MAINTENANCE <br />OF THE CONTRACTOR.THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR <br />CONTRACT (N.I.C.). UNLESS OTHERWISE NOTED ON THESE DRAWINGS OR IN <br />INSTRUCTIONS AND SIMILAR DATA, AS WELL AS ALL GUARANTEE(S) FOR ALL <br />ALL SUB -CONTRACTORS. IF THE CONTRACTOR FAILS TO COMPLETE THE <br />THE SPECIFICATIONS AS BEING NOT IN CONTRACT OR EXISTING, ALL ITEMS, <br />EQUIPMENT AND OPERABLE DEVICES FURNISHED OR INSTALLED BY THE <br />REPAIRS IN A TIMELY FASHION, SAID REPAIRS WILL BE MADE BY A <br />MATERIALS, ETC. AND THE INSTALLATION OF SAME ARE A PART OF THE <br />CONTRACTOR UNDER THIS CONTRACT, AND SHALL ORIENT AND INSTRUCT <br />CONTRACTOR SELECTED BY THE OWNER'S REPRESENTATIVE AND BACK <br />CONTRACT DEFINED BY THESE DRAWINGS AND SPECIFICATIONS. <br />THE PERSONNEL DESIGNATED BY THE CLIENT IN THE OPERATION OF ALL SUCH <br />CHARGED ACCORDINGLY. <br />EQUIPMENT. <br />33. <br />MINOR DETAILS NOT SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER <br />11, <br />THE CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLESS THE OWNER, THE <br />CONSTRUCTION OF ANY PART OF THE WORK, SHALL BE INCLUDED AS IF THEY <br />55. <br />THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER IN THE EVENT <br />TENANT, AND ARCHITECT AGAINST ANY AND ALL CLAIMS AND DEMANDS FOR <br />WERE INDICATED IN THE DRAWINGS, UNLESS OTHERWISE AGREED UPON. <br />THAT MOLD, ASBESTOS, OR OTHER ENVIRONMENTAL HAZARD IS UNCOVERED. <br />THE DAMAGE TO THE PROPERTY OF ANY PERSON, FIRM OR INDIVIDUAL OR <br />WHERE THE CONTRACT, CONSTRUCTION NOTES OR DRAWINGS CALL FOR ANY <br />THE OWNER SHALL RETAIN A QUALIFIED CONSULTANT WHO SHALL ARRANGE <br />FOR PERSONAL INJURIES (INCLUDING DEATH) ARISING OUT OF, OR SUFFERED <br />WORK OF A MORE STRINGENT NATURE THAN THAT REQUIRED BY THE <br />FOR THE PROMPT IDENTIFICATION, TESTING, TREATMENT, REMEDIATION AND <br />WHILE ENGAGED IN, OR CAUSED, IN WHOLE OR IN PART, BY THE EXECUTION <br />BUILDING CODE, OR ANY OTHER ENTITY HAVING JURISDICTION OVER THE <br />STORAGE OF THE MOLD OR ASBESTOS AS REQUIRED BY LAW AND GOOD <br />OF THE WORK; THE CONTRACTOR SHALL WELL AND TRULY DEFEND THE <br />WORK, THE WORK OF THE MORE STRINGENT NATURE CALLED SHALL BE <br />CONSTRUCTION PRACTICES. THE ARCHITECT SHALL BEAR NO RESPONSIBILITY <br />OWNER, TENANT AND ARCHITECT AND SHALL PAY ALL MONIES AWARDED FOR <br />FURNISHED IN ALL CASES. <br />FOR WORK RELATED TO THESE MATERIALS. <br />SUCH DAMAGES OR INJURIES (INCLUDING DEATH), ALL COSTS INCLUDING <br />ATTORNEY'S FEES SUSTAINED, AND SHALL OBTAIN A FULL ACQUAINTANCE <br />34. <br />FOR ALL MATERIALS PURCHASED THE CONTRACTOR SHALL FURNISH <br />56. <br />THE CONTRACTOR IS ADVISED THAT THE PREMISE HAS NOT BEEN TESTED FOR <br />AND RELEASE IN FAVOR OF THE OWNER, TENANT AND ARCHITECT, UNLESS <br />MATERIALS WHICH YIELD THE HIGHEST PERCENT OF PRE -CONSUMER <br />LEAD PAINT OR OTHER POTENTIALLY HAZARDOUS MATERIALS. THE <br />SUCH LIABILITY RESULTS SOLELY FROM THE NEGLIGENCE OF THE OWNER, <br />(POST-INDUSTRIAL) AND POST -CONSUMER RECYCLED CONTENT. THE <br />CONTRACTOR SHALL USE ALL APPROPRIATE PRECAUTIONS IN THE CARRYING <br />TENANT, ARCHITECT, ITS AGENTS OR EMPLOYEES. <br />CONTRACTOR SHALL FURNISH THESE MATERIALS WITHIN THE PARAMETERS <br />OUT OF ALL CONSTRUCTION OPERATIONS WHICH MIGHT DISTURB SUCH <br />OF THE BUDGET AND SHALL NOT PURCHASE ANY COST -ADDING MATERIAL OR <br />MATERIALS. <br />12. <br />THE ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR THE PERFORMANCE <br />PAY A PREMIUM (MORE THAN FAIR MARKET VALUE) WITHOUT ARCHITECT AND <br />OF ANY WORK, NOR FOR THE MEANS AND METHODS OF CONSTRUCTION <br />OWNER ACKNOWLEDGEMENT AND APPROVAL. <br />57. <br />ALL CONTRACTORS SHALL CARRY PROPERTY DAMAGE AND PUBLIC LIABILITY <br />CHOSEN BY THE CONTRACTOR OR ANY SUB -CONTRACTORS, NOR SHALL THE <br />INSURANCE AS REQUIRED BY ANY GOVERNING AGENCIES HAVING <br />ARCHITECT GUARANTEE THE PERFORMANCE OF THEIR CONTRACTS. <br />35. <br />FOR ALL MATERIALS PURCHASED THE CONTRACTOR SHALL FURNISH <br />JURISDICTION AND COMPLYING WITH STATUTORY REQUIREMENTS FOR <br />MATERIALS MANUFACTURED WITHIN A 500 MILE RADIUS OF THE PROJECT <br />DISABILITY AND WORKMEN'S COMPENSATION. <br />13. <br />THE CONTRACTOR SHALL PERFORM DAILY CLEANING OF THE JOB SITE DURING <br />SITE WHERE AVAILABLE, WITHIN BUDGET, WITHIN FAIR MARKET VALUE AND <br />THE CONSTRUCTION PERIOD AND SHALL PROTECT FINISHED WORK FROM <br />DO NOT PRESENT RISK TO THE PROJECT SCHEDULE. <br />DAMAGE. IMMEDIATELY PRIOR TO OCCUPANCY, THE CONTRACTOR SHALL <br />PERFORM FINAL CLEANING OF THE WORK AREA INCLUDING, BUT NOT LIMITED <br />36. <br />FOR ALL NEW WOOD PRODUCTS INCLUDING BUT NOT LIMITED TO PARTICLE <br />TO, WET WIPING OF FURNITURE, AND CASEWORK, WASHING AND WAXING OF <br />BOARD, MDF, PLYWOOD, OSB AND WOOD DOORS, THE CONTRACTOR SHALL <br />VCT FLOORING AND THE VACUUMING OF CARPET. ALL CLEANING SHALL BE IN <br />FURNISH MATERIALS THAT CONTAIN NO ADDED UREA-FORMADALHYDE. <br />ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. <br />37. <br />DETAILS ARE INTENDED TO SHOW THE INTENT OF THE DESIGN. MINOR <br />14. <br />THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL <br />MODIFICATIONS MAY BE REQUIRED TO SUIT FIELD CONDITIONS. REQUIRED <br />SUB -CONTRACTORS AND SHALL PERFORM SUCH MISCELLANEOUS WORK AS <br />MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. <br />MAY BE NECESSARY FOR THEM TO COMPLETE THEIR WORK. IT IS EXPECTED <br />THAT THE CONTRACTOR SHALL ALSO CLOSELY COORDINATE THE WORK WITH <br />38. <br />ALL WORK SHALL BE EXECUTED IN A PROFESSIONAL MANNER BY TRADES <br />THAT OF ALL OTHER VENDORS RETAINED BY THE CLIENT TO ASSURE THAT <br />PERSONS SKILLED IN THEIR RESPECTIVE TRADES AND IN ACCORDANCE WITH <br />ALL SCHEDULES ARE MET AND THAT WORK PROCEEDS WITHOUT DELAY. <br />THE INDUSTRY STANDARD TRADE PRACTICES. <br />15. <br />BIDDERS, BEFORE SUBMITTING PROPOSALS, SHALL VISIT AND CAREFULLY <br />39. <br />ALL WORK SHALL BE PLUMB, LEVEL AND TRUE. THE CONTRACTOR SHALL LAY <br />EXAMINE THE AREA AFFECTED BY THE WORK TO FAMILIARIZE THEMSELVES <br />OUT ALL WORK AND ESTABLISH ALL POINTS, GRADES, LINES AND LEVELS AND <br />WITH THE EXISTING CONDITIONS AND THE DIFFICULTIES THAT WILL AFFECT <br />ASSUME FULL RESPONSIBILITY FOR THE SAME. <br />THE EXECUTION OF THE WORK. SUBMISSION OF A PROPOSAL WILL BE <br />N <br />o <br />N <br />ti <br />0 <br />0 <br />z <br />U <br />a <br />0 <br />m <br />o <br />� <br />N <br />w <br />d <br />� <br />0 <br />LL <br />w <br />D <br />U) <br />0 <br />z <br />INFINITY ENGINEERING <br />GROTTY', LLC <br />1208 East Kennedy Boulevard <br />Suite 230 <br />Tampa, Florida 33602 <br />[p]. 813,434.4770 <br />[fl: 813.445.4211 <br />www.iegroup.net <br />FL Cert. of Auth. No. 27889 <br />r <br />NISIT SAPPARKHAO, P.E. <br />FL EG. NO . 64085 <br />No b408ST <br />.�. <br />nt <br />LO <br />TZ <br />M <br />L+_ <br />O <br />J <br />z = <br />U <br />_J a. <br />W <br />= N <br />j <br />00 <br />0 J <br />W <br />N <br />a <br />a o <br />@ 00 <br />a) I- <br />E <br />M <br />z <br />a <br />0 <br />n <br />am <br />F- <br />W <br />W <br />F_ <br />O <br />z <br />J <br />ct <br />W <br />z <br />W <br />IF -Project No. <br />Sheet <br />280-22.00 <br />/� <br />A-N. 1 <br />_ <br />Date <br />AS NOTED <br />Scale <br />AS NOTED <br />