Laserfiche WebLink
F- — — — — — <br />I <br />I <br />I <br />I <br />- -- - - --- - ----------------- ----------- <br />8 <br />A-9.1 <br />EQ EQ <br />M <br />I <br />CONSTRUCTION KEYNOTES: <br />'1 PROVIDE NEW UPSEND VAT SYSTEM. UTILIZE EXISTING POWER/DATA <br />FEEDS FROM REMOVED ITM FOR POWER AND DATA AT UPSEND VAT. <br />2 j NEW CONCRETE ISLAND INFILL. MATCH EXISTING DEPTH, TOP TO BE <br />FLUSH WITH EXISTING ISLAND. REFER TO 5/A-9.1 FOR EXPANSION JOINT <br />DETAIL. <br />3 i DIAGRAMMATICAL ROUTE OF VAT TUBE ABOVE CANOPY/CEILING INTO <br />BAKING CENTER. VENDOR TO FIELD FIT VAT TUBE AROUND EXISTING <br />HAVC AND ELECTRICAL WORK AS REQUIRED TO ACHIEVE FINAL <br />PLACEMENT AT TELLER LINE AS SHOWN ON 1/A-2.2. <br />4 `, VAT ENCLOSURE SEE SHEET A-9.1 FOR MORE INFORMATION. ALIGNMENT <br />AND POSITION OF ENCLOSURE IS TO BE CENTERED AROUND VAT TUBE. <br />COORDINATE ENCLOSURE LOCATION WITH VAT VENDOR & TUBE <br />ROUTING. <br />5 'j 4" STEEL PIPE BOLLARD FILLED WITH CONCRETE. REFER TO 3/A-9.1 FOR <br />MORE INFORMATION AND DIMENSIONS. REFER TO 7/A-9.1 FOR LAYOUT <br />DIMENSIONS. <br />"6 ' NEW LED LANE SIGNAGE BY VENDOR. UTILIZE EXISTING POWER/DATA <br />FROM REMOVED SIGNAGE PER 1/A-2.1. SEE 2/A-2.2 FOR MORE <br />INFORMATION. <br />2 <br />%�22 <br />1.9 <br />SCALE CONSTRUCTION PLAN - CANOPY 1/4"=1'-0" 2 — <br />CONSTRUCTION SHEET NOTES <br />A. AT NO TIME DURING CONSTRUCTION SHALL WORK IN PROGRESS BE LEFT IN A <br />CONDITION THAT WILL REDUCE OR IMPEDE REQUIRED ACCESS TO PATH OF <br />EGRESS OR EXIT. <br />B. ALL WORK SHALL BE IN COMPLIANCE WITH APPLICABLE FEDERAL, STATE AND <br />LOCAL BUILDING CODES, REGULATIONS, ORDINANCES AND STANDARDS <br />INCLUDING ADA AND OR OTHER HANDICAP ACCESSIBILITY CODES. <br />C. CONTRACTOR SHALL COORDINATE WITH THE OWNER'S VENDORS REGARDING <br />SCHEDULING AND SEQUENCING OF THE WORK. <br />D. REVIEW ALL DRAWINGS, MANUALS AND NOTES BEFORE COMMENCING WORK. <br />E. ALL DIMENSIONS ARE TO FINISH FACE OF WALL U.N.O. <br />F. DIMENSIONS SHOWN AS V.I.F SHALL BE VERIFIED BY THE CONTRACTOR IN THE <br />FIELD. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCY IN <br />DIMENSIONS PRIOR TO PROCEEDING WITH THE WORK IN THAT AREA. <br />G. DRYWALL FINISHING: COMPLY WITH MANUFACTURE'S PRINTED INSTRUCTIONS <br />AND SPECIFICATIONS, EXCEPTION: COMPLY WITH MORE STRINGENT <br />REQUIREMENTS OF GYPSUM ASSOCIATION GA-216 RECOMMENDED <br />SPECIFICATION FOR THE APPLICATION AND FINISHING OF GYPSUM BOARD. <br />H. CONTRACTOR SHALL CONFIRM AND COORDINATE PLACEMENT OF ALL <br />BLOCKING FOR MILLWORK, LIGHTS, EQUIPMENT, SHELVING, ETC. PRIOR TO <br />CLOSING WALLS. <br />I. PENETRATIONS IN GYPSUM BOARD CONSTRUCTION ABOVE FINISHED CEILING <br />SHALL BE EFFECTIVELY SEALED TO PREVENT SOUND LEAKAGE AT <br />ACOUSTICAL PARTITIONS AND AT DEMISING PARTITIONS, UNLESS OTHERWISE <br />NOTED. <br />J. CONTRACTOR SHALL COORDINATE STUD LOCATIONS W/OUTLET DIMENSIONS <br />PRIOR TO CLOSING WALLS WITH GYPSUM BOARD. <br />K. WHERE A CHANGE OF PLANE OF a " OR MORE OCCURS, SUBMIT NOTIFICATION <br />OF THE INSTANCE AND RECOMMENDATION FOR PROVIDING A CORRECTION <br />AND SMOOTH TRANSITION TO THE A/E FOR REVIEW. <br />L. FIXTURES AND/OR EQUIPMENT FURNISHED AND INSTALLED BY G.C. UNLESS <br />OTHERWISE SPECIFIED. SEE EQUIPMENT AND FIXTURE SCHEDULE. <br />M. SEE MEP DRAWINGS FOR LOCATIONS OF ALL CONDUIT. <br />/MA <br />DEMOLITION KEYNOTES: <br />REMOVE EXISTING ITM. SALVAGE DATA AND ELECTRICAL FOR NEW VAT <br />PER 2/A2.1. COORDINATE WITH OWNER FOR ITM STORAGE LOCATION. <br />2 REMOVE EXISTING BOLLARDS ASSOCIATED WITH ITM. PATCH AND <br />REPAIR CONCRETE ISLAND TO LIKE NEW FINISH. <br />3 i EXISTING CURB TO REMAIN - PROTECT DURING CONSTRUCTION. <br />(4 EXISTING BUILDING COLUMN TO REMAIN - PROTECT DURING <br />CONSTRUCTION. <br />5l? EXISTING BOLLARD TO REMAIN - PROTECT DURING CONSTRUCTION. <br />6 i EXISTING CANOPY ABOVE TO REMAIN. REFER TO 2/A2.1 & 1/A4.1 FOR NEW <br />CONSTRUCTION AT CANOPY. <br />\71, EXISTING ATM, BOLLARDS AND ISLAND TO REMAIN. <br />j 8 SAWCUT AND REMOVE PORTION OF ATM ISLAND AS REQUIRED TO RUN <br />NEW POWER AND DATA FROM EXISTING ITM STUB UP TO NEW VAT <br />LOCATION. <br />g REMOVE EXISTING TELLER CONNECT SIGNAGE. SALVAGE POWER/DATA <br />- FOR REUSE AT NEW SIGNAGE PER 2/A-2.1. <br />E <br />SCAL <br />DEMOLITION PLAN - CANOPY SCALE <br />1 <br />DEMOLITION SHEET NOTES <br />A. DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN ON <br />DRAWINGS. THE INTENT IS TO INDICATE THE GENERAL SCOPE OF <br />DEMOLITION REQUIRED TO COMPLETE THE WORK IN ACCORDANCE W/ <br />THE CONTRACT DRAWINGS. <br />B. PRIOR TO DEMOLITION WORK, REVIEW ALL DRAWINGS W/ OWNER'S <br />REPRESENTATIVE REGARDING DEMOLITION OR PRESERVATION OF ANY <br />CRITICAL SYSTEMS AND HOW TO HANDLE THESE DURING THE <br />DEMOLITION PERIOD. <br />C. PRIOR TO DEMOLITION WORK CONSULT W/ DATA AND TELEPHONE <br />COORDINATOR TO IDENTIFY SPECIFIC ITEMS TO BE LEFT IN PLACE. <br />D. GENERAL CONTRACTOR SHALL PROTECT AND MAINTAIN OPERATION OF <br />ALL FIRE PROTECTION SYSTEMS AND DEVICES, INCLUDING BUT NOT <br />LIMITED TO SMOKE DETECTION DEVICES, SPEAKERS AND FIRE ALARM <br />BOXES. ALL DEVICES DAMAGED DURING DEMOLITION SHALL BE <br />IMMEDIATELY REPAIRED TO OPERATIONAL STATUS. ALL REPAIRS SHALL <br />BE IN COMPLIANCE W/ ALL APPLICABLE CODES. <br />E. PATCH AND REPAIR EXISTING CONSTRUCTION WHERE AFFECTED BY <br />DEMOLITION. WORK SHALL BE PROPERLY RESTORED, ALIGNED AND <br />REPAIRED SO AS TO LEAVE NO EVIDENCE OF DEMOLITION OR <br />REMODELING WORK. AREAS OUTSIDE OF THE CONTRACT LIMITS <br />AFFECTED BY DEMOLITION AND NEW CONSTRUCTION TO BE REPAIRED <br />SO AS TO LEAVE NO EVIDENCE OF THE WORK. REFINISH TO MATCH <br />EXISTING ADJACENT FINISH, OR AS NOTED HEREIN. <br />NORTH <br />0 2'-0" 4'-0" 8'-0" <br />SCALE: 1 /4" = 1 "-0" <br />N <br />O <br />N <br />h <br />MMOIN <br />2 <br />M <br />z <br />U <br />a <br />z <br />z <br />n <br />o <br />� <br />w <br />Mn <br />a <br />m <br />0 <br />w <br />w <br />n <br />U) <br />b <br />z <br />INFINITY ENGINEERING <br />GROUP, LLC <br />1208 East Kennedy Boulevard <br />Suite 230 <br />Tampa, Florida 33602 <br />[p]: 813.434.4770 <br />[4:813,445.4211 <br />www.iegroup.net <br />FL Cert. of Auth. No. 27889 <br />aTa❑ <br />.... ........ <br />NISIT SAPPARKHAO, P.E. <br />FL• REC. NO. 64085 <br />4 <br />No 640' <br />a <br />i w <br />3� E O F <br />s : , <br />0 <br />4 0 on <br />\O, <br />hater - <br />r <br />d' <br />Ln <br />z <br />� <br />co M <br />U- <br />Q <br />J <br />z <br />Q <br />O <br />Z <br />z <br />i <br />O_z <br />C <br />_ <br />�O <br />J <br />a <br />J <br />I— <br />= <br />N <br />OU <br />W <br />= <br />m <br />Q <br />�— <br />W <br />J <br />Q <br />Z <br />a <br />N <br />0 <br />O <br />C <br />00 <br />~ <br />o <br />z <br />U <br />a) <br />asz <br />o <br />F <br />(U <br />(D <br />n <br />u) <br />Project No. Sheet <br />280-22.00 <br />Date <br />AS NOTED A-2. 1 <br />Scale <br />AS NOTED <br />