GENERAL NOTES <br />DESIGN LOADS <br />SOIL BEARING PRESSURE (USED FOR DESIGN) 2000 PSF <br />ROOF LIVE LOAD_-_ __ _ _ _ __ _. _-__--30 PSF <br />ROOF DEAD LOAD 20 PSF <br />CONCRETE STRENGTH (28-DAY) 3000 PSI <br />STRUCTURAL STEEL BEAMS_ .___ _ ___- ___ ___ -ASTM A992 <br />STEEL SHAPES, EXCEPT BEAMS-- - ASTM A36 <br />REINFORCING STEEL __ - ASTM A-615, OR, 60 <br />MASONRY DESIGN STRENGTH F'M = 1500 PSI <br />WIND PRESSURES, PER ASCE 7-10: <br />EXPOSURE CATEGORY._- _ _ -_ 'C' <br />WIND SPEED, Vult (Vase 137 MPH (107) <br />RISK CATEGORY _ _ CATEGORY II <br />INTERNAL PRESSURE COEFFICENTS (ENCLOSED BLDG--- ._ _ +0,18/-0J8 <br />SEISMIC CRITERIA; <br />SPECTRAL RESPONSE ACCELERATIONS <br />SDS N/A <br />SD1 -- ---- - N/A <br />R (BUILDING FRAME SYSTEM W/ ORD, REINF, MAS. SHEARWALLS) - .N/A <br />SUBSURFACE SITE CLASS _ _ N/A <br />RISK CATEGORY N/A <br />SEISMIC DESIGN CATEGORY N/A <br />ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE <br />DESIGN BASE SHEAR N/A <br />GROUND SNOW LOAD 0 PSF <br />SOIL BEARING PRESSURE = 3000 PSF AS PER SUBSURFACE INVESTIGATION BY <br />ARDAMAN & ASSOCIATES, DATED OCTOBER 8, 2007 (PROJ, # 07-55-9800). <br />THIS STRUCTURE HAS BEEN DESIGNED TO COMPLY WITH LATEST EDITION OF THE FBC 2017. <br />CONSTRUCTION SAFETY <br />1. THESE DRAWINGS DO NOT INCLUDE PROVISIONS TO SATISFY SAFETY REQUIREMENTS. CONTRACTOR <br />IS SOLELY RESPONSIBLE FOR ENSURING SAFETY DURING CONSTRUCTION, AND FOR CONFORMANCE <br />TO ALL APPLICABLE OSHA STANDARDS, JOBSITE VISITS BY ENGINEER/PUBLIX REP, SHALL NOT <br />CONSTITUTE APPROVAL, AWARENESS OR LIABILITY FOR ANY HAZARDOUS CONDITIONS. <br />2, DO NOT OVERLOAD ONE SEGMENT OR SPAN OF A BEAM CONTINUOUS OVER SEVERAL SUPPORTS, <br />BEAMS SHOULD BE LOADED AS GRADUALLY AND EVENLY AS POSSIBLE UNTIL THE FULL LOAD IS IN PLACE, <br />3, ERECTION SEQUENCE SHALL BE DETERMINED BY THE CONTRACTOR, AND SHALL NOT CAUSE OVERSTRESS <br />OR EXCESSIVE DEFORMATION OF STRUCTURAL MEMBERS, <br />4, NO PROVISION HAS BEEN MADE IN THE STRUCTURAL DESIGN FOR TEMPORARY CONDITIONS <br />OCCURING DURING CONSTRUCTION, UNLESS NOTED SPECIFICALLY ON THE STRUCTURAL DRAWINGS. <br />THE CONTRACTOR SHALL PROVIDE ALL NECESSARY SHORING AND BRACING REQUIRED TO RESIST <br />STRESSES OR INSTABILITY OCCURING FROM ANY CAUSE DURING CONSTRUCTION. THE CONTRACTOR <br />SHALL ASSUME COMPLETE RESPONSIBILTY FOR SUCH MEASURES. <br />5, ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES <br />AND ORDINANCES, <br />DRAWINGS AND SPECIFICATIONS <br />1, DO NOT SCALE THESE DRAWINGS FOR DIMENSIONS NOT GIVEN, <br />2, THE CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK AT ANY TIME WITHOUT CONTRACT <br />DOCUMENTS OR, WHERE REQUIRED, APPROVED SHOP DRAWINGS. <br />3, THESE GENERAL STRUCTURAL NOTES ARE INTENDED TO EMPHASIZE CERTAIN INFORMATION MORE <br />COMPLETELY DISCUSSED IN THE PROJECT SPECIFICATIONS (PM SHEETS), THE CONTRACTOR <br />SHOULD BE FAMILIAR WITH THE REQUIREMENTS AS STATED IN THE SPECIFICATIONS. <br />FOUNDATIONS <br />1, FOUNDATION DESIGNED FOR THE SOIL BEARING PRESSURE AS DESCRIBED IN THE DESIGN CRITERIA, <br />IF CONDITIONS AT THE SITE DO NOT PROVIDE THIS MINIMUM VALUE, NOTIFY PUBLIX STRUCTURAL <br />ENGINEER IMMEDIATELY, <br />2, FOUNDATION SIZES SHALL NOT BE REDUCED FOR ANY REASON, EVEN IF HIGHER SOIL BEARING VALUES <br />ARE ACHIEVED, <br />3, TOP OF ALL FOOTINGS TO BE A MINIMUM OF 24' BELOW FINISHED FLOOR, <br />4, PUBLIX REQUIRES THAT MAXIMUM TOTAL SOIL SETTLEMENTS NOT EXCEED 1' AND MAXIMUM <br />DIFFERENTIAL SOIL SETTLEMENTS NOT EXCEED 1/2', <br />5, PUBLIX REQUIRES SOIL COMPACTION OF 95% OF MODIFIED PROCTOR OR 98% OF STANDARD PROCTOR, <br />' REFER TO GEOTECHNICAL REPORT FOR MORE INFORMATION. <br />REINFORCED CONCRETE <br />1, CONCRETE MATERIALS, MIXING AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH <br />GOOD ENGINEERING PRACTICES AND SHALL CONFORM TO THE LATEST EDITIONS OF ACI 301, <br />ACI 318 AND ASTM C-94. <br />2, REINFORCING STEEL SHALL CONFORM TO ASTM A615; YIELD STRENGTH = 60 KSI, MINIMUM. <br />3, CONTRACTOR SHALL SUBMIT REINFORCEMENT SHOP DRAWINGS FOR REVIEW PRIOR TO CONSTRUCTION, <br />4, CONTRACTOR SHALL PROVIDE CONCRETE MIX DESIGNS FOR REVIEW PRIOR TO POURING, <br />PUBLIX MIX DESIGN REQUIREMENTS: NO CEMENT REPLACEMENT(I.E, FLY ASH), 500 LBS, MIN CEMENT <br />MAX, W/C RATIOS: 0.58 FOR 3000 PSI. ALL CONCRETE SHALL BE 3000 PSI. <br />5, CONTRACTOR SHALL PROVIDE COPIES OF ALL STRUCTURAL CONCRETE COMPRESSIVE STRENGTH <br />TEST RESULTS TO THE ENGINEER OF RECORD FOR REVIEW, ALSO, CONTRACTOR TO HAVE COPIES <br />OF CONCRETE TEST REPORTS AVAILABLE ON SITE. <br />6, FOR READY -MIX CONCRETE, THE MAXIMUM TIME PERMITTED BETWEEN BATCHING AND <br />DEPOSITING IN THE FORMS IS 90 MINUTES. CONCRETE EXCEEDING THE ABOVE SHALL BE REJECTED, <br />7, THE ADDITION OF WATER AT THE SITE TO INCREASE CONCRETE SLUMP SHALL NOT BE ALLOWED <br />AND SHALL BE JUST CAUSE FOR REJECTION OF THAT BATCH OF CONCRETE, <br />8, MINIMUM CONCRETE COVER TO REINFORCING STEEL, UNLESS NOTED OTHERWISE ON DRAWINGS: <br />CAST AGAINST EARTH = 3' <br />EXPOSED TO EARTH OR WEATHER = FOR #5 OR LESS USE 1 1/2', ALL OTHERS 2' <br />BEAMS AND COLUMNS = 1 1/2' <br />9, ALL REINFORCEMENT SHALL BE SECURELY HELD IN PLACE BY STANDARD ACCESSORIES <br />DURING CONCRETE PLACEMENT. <br />10, PROVIDE THE FOLLOWING MINIMUM LAP SPLICES: #4=29', #5=36', #6=43', #7=63', #8=72', <br />FOR ALL REINFORCING BARS, UNLESS NOTED OTHERWISE. DO NOT SPLICE TIE BEAM <br />REINFORCEMENT OVER OPENINGS. DO NOT SPLICE FOOTING REINFORCEMENT UNDER OPENINGS. <br />11, IN WALL FOOTINGS, CONCRETE BEAMS AND BOND BEAMS,PROVIDE BENT BARS AT CORNERS <br />AND INTERSECTIONS OF THE SAME NUMBER AND SIZE AS THE STRAIGHT BARS, <br />CONCRETE MASONRY UNITS <br />1. CONCRETE MASONRY UNITS SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM <br />C90 AND SHALL HAVE A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 1900 PSI, <br />2, IN ACCORDANCE WITH ACI 530, THE 1900 PSI BLOCK IN COMBINATION WITH TYPE M <br />OR S MORTAR (1800 PSI, MIN,) PROVIDE A DESIGN COMPRESSIVE STRENGTH OF F'M = 1500 PSI. <br />3. FILLED CELL GROUT IS NOT TO BE MIXED ON -SITE, BUT MUST COME FROM A READY MIX SUPPLIER. <br />4, A MIX DESIGN FOR THE FILLED CELL GROUT MUST BE SUBMITTED TO THE ENGINEER FOR APPROVAL, <br />5, COMPRESSIVE STRENGTH TESTS MUST BE CONDUCTED FOR FILLED CELL GROUT, <br />6. HOOK VERTICAL BARS INTO FOOTING, AND EXTEND INTO AND HOOK IN TOP OF WALL BOND BEAM, <br />PROVIDE STANDARD ACI 90 DEGREE HOOK AT DISCONTINUOUS END OF VERTICAL BARS. <br />(10' MIN, HOOK LENGTH), LAP VERTICAL REINFORCEMENT PER MASONRY LIFT DETAIL, <br />7, EXPANSION BOLTS AND/OR SLEEVE ANCHORS ARE NOT ALLOWED IN PUBLIX WALLS, <br />8, ALL EXTERIOR MASONRY WALLS TO BE FILLED FULL HEIGHT WITH APPROVED MASONRY WALL <br />INSULATION ABOVE FINISHED FLOOR. <br />STRUCTURAL STEEL <br />1, HOT -ROLLED STEEL BEAMS SHALL BE ASTM A992 (50 KSI), PLATES, BARS, CHANNELS, RODS AND ANGLES <br />SHALL CONFORM TO ASTM A36, <br />2. ANCHOR BOLTS SHALL CONFORM TO ASTM F1554, GR36(MIN.) AND MUST BE MECHANICALLY BENT, <br />NOT TEMPERED OR HEATED. HIGH STRENGTH BOLTS SHALL BE ASTM A325, <br />3, STEEL PIPE SHALL CONFORM TO ASTM A53, GRADE B, FY=35 KSI. <br />4, HOLLOW STRUCTURAL SECTIONS (HSS) SHALL CONFORM TO ASTM A500 GRADE B (FY=46 KSI). <br />5, ALL WELDS SHALL BE MADE WITH E70 LOW HYDROGEN ELECTRODES, BY QUALIFIED <br />WELDERS AS PER AMERICAN WELDING SOCIETY REQUIREMENTS (AWS D1.1), SUBMIT WELDERS <br />CERTIFICATES FOR WELDERS EMPLOYED ON THE PROJECT, VERIFIYING AWS QUALIFICATIONS <br />WITHIN THE PREVIOUS 12 MONTHS. ALSO, ONE OF THESE CERTIFICATIONS MUST BE AVAILABLE <br />AT THE JOB SITE. <br />6, ALL BOLTS SHALL BE HIGH -STRENGTH ASTM A325, 3/4IN. DIA., UNLESS NOTED OTHERWISE. <br />BOLTED CONNECTIONS SHALL BE SNUG -TIGHT (1/3 TURN AFTER SEATED), U.N,O, <br />7, CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY BRACING, SHORING AND GUYING OF <br />THE FRAMING AGAINST WIND, CONSTRUCTION LOADS OR OTHER TEMPORARY FORCES UNTIL <br />SUCH PROTECTION IS NO LONGER REQUIRED FOR THE SAFE SUPPORT OF THE STRUCTURE, <br />8, RETURN ALL WELDS AT CORNERS TWICE THE NOMINAL WELD SIZE MINIMUM. <br />9, FRAMING CONNECTIONS SHALL BE AISC TYPE 2 DOUBLE -ANGLE BOLTED CONNECTIONS, <br />U,N,O, SELECT CONNECTIONS TO SUPPORT ONE-HALF THE TOTAL UNIFORM LOAD <br />CAPACITY SHOWN IN THE UNIFORM LOAD TABLES, PART 3 OF THE AISC MANUAL (13th ed.), <br />FOR THE SPAN AND GRADE OF STEEL SPECIFIED, <br />10. NO HOLES, OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS, SHALL BE PERMITTED <br />WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER OF RECORD. <br />11, WELDS, NOT OTHERWISE DESIGNATED, SHALL BE 1/4IN, MINIMUM FILLET, <br />12, SEE ARCHITECTURAL ELEVATIONS, SECTIONS AND DETAILS FOR MISCELLANEOUS STEEL. <br />13. ALL HEADED STUD ANCHORS (ASTM A108) AND ANCHOR BOLTS TO HAVE A MIN, 8' EMBEDMENT, U,N,O, <br />14, CONTRACTOR SHALL ENGAGE AN INDEPENDENT TESTING LABORATORY AND INSPECTION AGENCY TO <br />PERFORM STEEL ERECTION INSPECTIONS AND TESTING. COPIES OF ALL STEEL INSPECTION REPORTS <br />SHALL BE SENT TO THE ENGINEER OF RECORD AND PUBLIX CONSTRUCTION. <br />15, CONTRACTOR SHALL COMPLY WITH ERECTION TOLERANCES AS STATED IN THE AISC CODE OF <br />STANDARD PRACTICE, AISC 303-05. <br />LIGHT GAUGE FRAMING <br />1, ALL LIGHT GAUGE STEEL FRAMING SHALL CONFORM TO THE 'SPECIFICATIONS FOR THE DESIGN OF <br />COLD -FORMED STRUCTURAL STEEL MEMBERS,' AISI.' <br />2, ALL STUDS SHALL BE EQUAL TO A MINIMUM OF 6-INCH 54 MIL THICK, U,O,N, FOR EXTERIOR APPLICATIONS <br />3, ALL STUDS SHALL BE 'C' SHAPE, U,O,N, <br />4. MATERIALS, U.O,N,: <br />54, 68 AND 97 MIL STUDS 50 KSI <br />27, 33, AND 43 GA. STUDS 33 KSI <br />RUNNERS AND ACCESSORIES 33 KSI <br />5, PROVIDE MANUFACTUERS STANDARD STEEL RUNNERS, BRIDGING, BLOCKING, LINTELS, CLIP ANGLES, <br />BRACING, REINFORCEMENTS, FASTENERS, ETC, AS REQUIRED TO PROVIDE A COMPLETE STEEL <br />FRAMING SYSTEM CAPABLE OF ACCOMMODATING THE LOADS PRESENTED IN THE CONSTRUCTION <br />DOCUMENTS. <br />6. ALL PARTS AND ACCESSORIES SHALL BE FORMED FROM STEEL HAVING A G-60 GALVANIZED COATING <br />MEETING THE REQUIREMENTS OF ASTM A525 / ASTM A653. <br />7, ALL CONNECTIONS SHALL BE (4) #10-12 TEK SCREWS AS A MINIMUM, U,O.N, OR AS REQUIRED BY <br />MANUFACTURER AND APPROVED BY STRUCTURAL ENGINEER. <br />8, INSTALL METAL FRAMING IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS AND/OR <br />SPECIFICATIONS. <br />9, SPLICES IN STUDS SHALL NOT BE PERMITTED, <br />10. ALL PROPOSED ALTERNATE CONNECTION CLIPS SHALL BE SUBMITTED TO BUILDING ENGINEER FOR <br />REVIEW. SUBMITTAL SHALL INCLUDE APPLICABLE LOAD TABLES FOR CLIPS, <br />11, ALL LIGHT GAUGE STEEL FRAMING SHALL CONFORM TO ASTM C645 AND SHALL BE 33 KSI MINIMUM <br />YIELD STRENGTH, <br />12, ALL STUD MATERIALS SHALL BE 20 GAUGE (33 MIL) OR AS NOTED ON PLANS, <br />13, ALL NON -COMPOSITE (1 SIDE DRYWALL) INTERIOR PARTITION WALLS SHALL HAVE HORIZONTAL BRIDGING <br />AT 4'-0' O.C, BETWEEN LATERAL SUPPORTS. BRIDGING ALSO REQUIRED ABOVE 2 SIDED DRYWALL THAT <br />STOPS SHORT OF THE DECK, <br />14. CONNECTION TYPES (U,O,N,); <br />A. STUD TO RUNNER TRACK: (1)#10-12 TEK SCREW EACH LEG, (2 TOTAL) <br />B. BOTTOM RUNNER TRACK TO SLAB: (2) 3/16' X 1 1/2' CONCRETE SCREWS (TAPCONS) AT EACH STUD <br />AND (1) OF SAME SPACED BETWEEN THE STUDS. <br />C. TOP RUNNER TRACK TO STEEL CHANNELS: 0,145' DIA x 1/2' SHANK PAFs <br />(HILTI X-EDNI) @ 8' O,C„STAGGERED, (ALSO REFER TO HANGING SOFFIT DETAILS ON S-3), <br />D. TOP RUNNER TRACK RUNNING PERPENDICULAR TO JOISTS (WALL BEARING ON SLAB); (4) #10-12 SCREWS <br />(OR HILTI X-EDNI) TO BOTTOM CHORD OF EACH JOIST, <br />E, TOP RUNNER TRACK TO STEEL DECKS (2) #10-12 TEK SCREWS @ EACH STUD LOCATION AND (1) OF SAME <br />SPACED BETWEEN THE STUDS, <br />F, KICKER/BRACE STUD TO VERTICAL STUD (4) #10-12 TEK SCREWS, <br />G. KICKER/BRACE STUD TO STEEL JOIST: 18 GAGE CLIP, WITH (4) #10-12 TEK SCREWS TO <br />BRACE AND (4) #12-10 TEK SCREWS TO STEEL JOIST BOTTOM CHORD, <br />15, REFER TO ARCHITECTURAL PLANS AND WALL SECTIONS FOR STUD WALL LOCATIONS AND CONFIGURATIONS, <br />EXISTING <br />CONC. SLAB <br />Of <br />NEW CONCRETE SLAB TRENCH (REF: PLANS FOR WIDTH) EXISTING <br />(MATCH EXISTING SLAB THICKNESS) CONC. SLAB <br />_ FLOOR FINISH NOT SHON. <br />MATCH EXISTING. <br />- -III-- \ <br />6- � 6- j <br />REPLACEMENT BASE AND TRENCH <br />BACKFILL SHALL BE PLACED IN 6' <br />LIFTS, EACH LIFT COMPACTED TO 98% <br />STANDARD PROCTOR, VISUAL INSPECTION <br />OF COMPACTION IS ACCEPTABLE IN LIEU <br />OF THIS REQUIREMENT PROVIDED THAT <br />INSPECTIONS ARE DONE BY CERTIFIED <br />MATERIAL TESTING COMPANY WITH A <br />SIGNED AND SEALED REPORT, PROVIDE 1/2' EXPANSION <br />JOINT (FLOATING SLAB) AT <br />EXTERIOR CMU WALL, TYP. <br />(WHERE OCCURS) <br />SLAB PATCHING DETAIL <br />SCALE: NONE <br />C <br />z <br />7 O <br />Cr. <br />a o SLOPE TO DRAIN <br />FIN GRADE r ° <br />cc <br />CONT. 8"x12" CONc. <br />IHICKENFD SLAB 8" <br />W/2#5 CONI. (TYP. 1 - <br />ALL AROUND) <br />-- <br />7i <br />#4 DOWELS, 12" LONG @ 2'-0' O.C., <br />STAGGERED EACH SIDE, DRILL AND <br />EPDXY 6' INTO EXISTING SLAB, USE <br />HILTI HIT HY-200 EPDXY <br />(DOWELS NOT REQUIRED IF SLAB TRENCH <br />IS LESS THAN 24' WIDE.) <br />NEW CONC, SLAB (3000 PSI) W/WWR 6x6-W1.4xW1.4. <br />MATCH EXISTING SLAB THICKNESS. <br />INCLUDE NEW VAPOR BARRIER AT INTERIOR <br />APPLICATIONS. <br />COOLER WALL <br />REF. FLOOR FINISH NOT SHOWN, <br />6" 6" 6" LUMBING MATCH EXISTING. <br />ui 77 z <br />d wm <br />WIN <br />6"� <br />REPLACEMENT BASE AND TRENCH <br />BACKFILL SHALL BE PLACED IN 6' <br />LIFTS, EACH LIFT COMPACTED TO 98% <br />STANDARD PROCTOR, VISUAL INSPECTIO <br />OF COMPACTION IS ACCEPTABLE IN LIE <br />OF THIS REQUIREMENT PROVIDED THAT <br />INSPECTIONS ARE DONE BY CERTIFIED <br />MATERIAL TESTING COMPANY WITH A <br />SIGNED AND SEALED REPORT. <br />CONC. SLAB <br />c4 #4 DOWELS, 12' LONG @ 2'-0' O.C., <br />a STAGGERED EACH SIDE, DRILL AND <br />EPDXY 6' INTO EXISTING SLAB, USE <br />HILTI HIT HY-200 EPDXY <br />(DOWELS NOT REQUIRED IF SLAB TRENCH <br />IS LESS THAN 24' WIDE.) <br />1'-4" <br />NEW CONC. SLAB (3000 PSI) <br />W/WWR 6x6-W1.4xW1.4. <br />MATCH EXISTING SLAB THICKNESS. <br />INCLUDE NEW VAPOR BARRIER AT INTERIOR <br />APPLICATIONS. <br />REFERENCE PLAN EXISTING <br />NEW CONCRETE SLAB CONC. SLAB <br />(MATCH EXISTING SLAB THICKNESS AND THICKEN AS SHOWN) <br />TRENCH DRAIN DETAIL <br />SCALE: NONE <br />7'-6" 7'-6" 7'-9" 7'-9' CON]. 8"x12" CONC. <br />-- --- -- -- - <br />HI K _N L.AI. <br />j W/2#5 CON T, (TYP. <br />COM P^,TOR SLAB FOUNDATION PLAN <br />MENT SHALL BE 100% VIRGIN POLYPROPYLENE, FIBRILLAIED FIBERS, <br />NUFACTURED FOR USE AS CONCRETE SECONDARY REINFORCEMENT (ASTM C-1116). <br />OF FIBERGLASS ADMIXTURE PER CUBIC YARD OF CONCRETE_ IS <br />LBS). THE TYPICAL FIBER LENGTH IS % TO 'a INCHES. <br />2'-0" - TRENC;H DRAIN 2' 0" _ <br />TRENCH DRAIN <br />TYP. RFCESSFD 1" RECESSED 1" TYP. <br />SLOPE TO DRAIN SLOPE TO DRAIN SLOPE TO DRAIN <br />4 e <br />o <br />SECTION A- A 77r <br />SCALE: NONE <br />TRASH COMPACTOR FOUNDATION PLAN & SECTIONS <br />SCALE: NONE <br />4 0 - --- <br />MIN. RAMP (VERIFY) <br />� FIN. GRADE <br />MIN. 24' BEYOND <br />EXISTING NEW _ <br />CONC. SLAB CONC. SLAB #4 DOWELS, 12' LONG @ 2'-0' O.C., <br />STAGGERED EACH SIDE, DRILL AND <br />EPDXY 6' INTO EXISTING SLAB, USE <br />HILTI HIT HY-200 EPDXY <br />FLOOR FINISH NOT SHOWN. <br />MAT�STING. <br />L6- 1, sn <br />REPLACEMENT BASE AND TRENCH NEW CONC. SLAB (3000 PSI) W/WWR <br />BACKFILL SHALL BE PLACED IN 6' 6x6-W1.4xW1.4, <br />LIFTS, EACH LIFT COMPACTED T 9 MATCH EXISTING SLAB THICKNESS. <br />STANDARD PROCTOR, VISUAL INS INCLUDE NEW VAPOR BARRIER AT INTERIOR <br />OF COMPACTION IS ACCEPT I APPLICATIONS. <br />OF THIS REQUIREMENT PROV <br />INSPECTIONS ARE DONE BY CE FI <br />MATERIAL TESTING COMPANY WI A <br />SIGNED AND SEALED REPORT. PROVIDE 1/2' EXPANSION <br />JOINT (FLOATING SLAB) AT <br />EXTERIOR CMU WALL, TYP. <br />(WHERE OCCURS) <br />SLAB PATCHING DETAIL <br />SCALE: NONE <br />EXISTING _ NEW <br />NC. SLAB CONC. SLAB #4 DOWELS, 12' LONG @ 2'-0' O.C., <br />STAGGERED EACH SIDE, DRILL AND <br />EPDXY 6' INTO EXISTING SLAB, USE <br />HI HY-200 EPDXY <br />( ELS T REQUIRED IF SLAB TRENCH <br />S S AN 24' WIDE.) <br />❑OR NISH NOT SHOWN, REF; ARCH <br />L6- <br />6" <br />REPLACEMENT BASE AND TREN --w <br />BACKFILL SHALL BE PLACED IN <br />LIFTS, EACH LIFT COMPACTED TO 98% <br />STANDARD PROCTOR, VISUAL INSPECTION <br />OF COMPACTION IS ACCEPTABLE IN LIEU <br />OF THIS REQUIREMENT PROVIDED THAT <br />INSPECTIONS ARE DONE BY CERTIFIED <br />MATERIAL TESTING COMPANY WITH A <br />I, III - <br />III <br />NEW 4' CONC, SLAB (3000 PSI) <br />W/WWR 6x6-W1.4xW1.4. INCLUDE NEW VAPOR <br />BARRIER AT INTERIOR APPLICATIONS. <br />SIGNED AND SEALED REPORT. PROVIDE 1/2' EXPANSION <br />JOINT (FLOATING SLAB) AT <br />EXTERIOR CMU WALL, TYP, <br />(WHERE OCCURS) <br />r5� SLAB PATCHING DETAIL <br />SCALE: NONE <br />�o <br />�00 <br />00 <br />N <br />Uw�M <br />01C� <br />i•a 0 <br />a <br />r-t-- <br />v <br />Coe <br />U <br />,-�O <br />arm <br />rn <br />0 <br />C6 <br />M <br />0 <br />m Z H_ <br />N <br />w <br />W <br />v J <br />rn <br />v <br />o (n <br />o <br />U <br />w <br />0 <br />� <br />a <br />U <br />w <br />C <br />Li <br />Q <br />G <br />NN <br />L.�.. <br />Q <br />W <br />a <br />H, <br />M <br />O 00 <br />0 <br />xU <br />ccfi <br />LL <br />w <br />M <br />X <br />5Z <br />wag <br />o <br />Z <br />w <br />n <br />■� <br />cM <br />J <br />U <br />Li <br />N <br />r <br />Z <br />O <br />GC <br />G <br />O <br />U <br />O <br />W <br />ch <br />IV <br />o <br />O <br />J <br />W <br />-J <br />m J <br />-ji = <br />ULU <br />U >' <br />o <br />00 <br />ccf) a <br />a <br />LLI <br />11- N <br />:0Cl <br />__o <br />CO,�LL <br />LUjl <br />rn <br />0 <br />N <br />J <br />N <br />a <br />m <br />W <br />M <br />J <br />W <br />W <br />U) <br />C <br />CD <br />o <br />O) <br />Z <br />� <br />N <br />~ <br />o0 <br />Go <br />N <br />W <br />Z <br />C� <br />a <br />0 <br />0 <br />U <br />S■ REC E® , <br />i <br />8 2019 <br />Hawkins Construction, Inc. <br />