My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3512 Malachite Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3512 Malachite Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 5:13:14 PM
Creation date
2/19/2025 12:38:37 PM
Metadata
Fields
Template:
Building Plans
Street #
3512
Location
Malachite Dr
Contractor
Paul and Carolyn Sholar- Owner
Building Plans - Permit #
5761
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENGINEER'S NOTES: <br />1, DESIGN WIND SPEED; 140 MPHult / 110 MPHascd , 3 sec gust <br />PER ATC HAZARDS BY L❑CATI❑N <br />2. RISK CATEGORY PER FBC 2020 7TH EDITI❑N Table 1604.5 ; II <br />3, EXPOSURE CATEGORY = 'B' <br />4. INTERNAL PRESSURE C❑EFFICIENT = +/- 0.18 (ENCLOSED BLDG) <br />5, COMPONENTS & CLADDING DESIGN PRESSURES PER ASCE 7-161 <br />FIGURE 30.4-1 WITH LAMDA FACTOR = 0,82 <br />HIP ROOF <br />ROOF ZONE 1 (20)SF: +12/-21 psf <br />ROOF ZONE 2e (10)SFi +13/-32 psf <br />ROOF ZONE 2r (10)SF; +13/-32 psf <br />ROOF ZONE 3 (10)SF: +13/-32 psf <br />WALL ZONE 4 (20)SF; +18/-20 psf <br />WALL ZONE 5 (20)SFi +18/-24 psf <br />6, ROOF LIVE LOAD: 20 psf <br />ROOF DEAL L❑AD; 15 psf <br />3/12 <br />PR (2) 60" X96" <br />WITH WIND❑W <br />0 <br />GENERAL NOTES <br />C❑NSTRUCTI❑N TYPE: 5-B <br />ACI 318-19 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />ACI 530-16, ASCE 5/TMS 402-16 & ACI 530.1-13, ASCE 6/TMS 602-16 <br />SPECIFICATI❑NS FOR MASONRY STRUCTURES. <br />ASTM C270-12a, C90-06b & C91-05 SPECIFICATI❑NS FOR MASONRY STRUCTURES <br />NATI❑NAL DESIGN SPECIFICATI❑NS (NDS) FOR WOOD CONSTRUCTION, 2015 EDITI❑N, AND ALL <br />ACC❑MPANYING SUPPLEMENTS, ASCE 7-16 <br />FLORIDA RESIDENTIAL CODE (FBC-R), FLORIDA BUILDING CODE (FBC) 7th ed, (2020) <br />'MANUAL OF STEEL C❑NSTRUCTI❑N, ALLOWABLE STRESS DESIGN", BY THE AMERICAN <br />INSTITUTE OF STEEL C❑NSTRUCTI❑N, (AISC) 13TH EDITI❑N, <br />"DESIGN SPECIFICATI❑N FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE <br />TRUSS PLATE INSTITUTE TRI1-14, <br />2 <br />SH 24 <br />DESIGN ; <br />ACI 301-16 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />ACI 530-16, ASCE 5/TMS 402-16 & ACI 5301-13, ASCE 6/TMS 602-16 <br />SPECIFICATI❑NS FOR MASONRY. STRUCTURES, <br />ASTM C270-12a, C90-06b & C91-05 SPECIFICATI❑NS FOR MASONRY STRUCTURES <br />NATI❑NAL DESIGN SPECIFICATI❑NS (NDS) FOR WOOD C❑NSTRUCTI❑N, 2015 EDITI❑N, <br />AND ALL ACC❑MPANYING SUPPLEMENTS, <br />PLYWOOD DESIGN SPECIFICATI❑NS (APA) <br />FLORIDA BUILDING CODE (FBC) 7th ed, (2020) AND <br />FLORIDA BUILDING CODE 7th ed. RESIDENTIAL (FBCR) <br />ASCE 7-16 <br />12'-4" <br />SH 24 <br />Ti <br />I <br />3 5' <br />X 3 cnm N ClJ <br />a O M <br />-i O Ga <br />I'D Z = <br />cu <br />_ r <br />ry � <br />d 3 <br />W/D <br />3' P D <br />RECESS iRECESS <br />3068 3068 <br />3' <br />F11010ATT ll_�_,'LIE,'VATION <br />N 0 T E ; <br />STRUCTURAL_ DESIGN REQUIRES <br />ALL DOORS AND WINDOWS TO BE FLORIDA APPROVED AND <br />RATED FOR INDICATED DESIGN PRESSURES AND <br />SPECIFIC BRANDS TO BE DETERMINED <br />BY ❑\A/NER AND C❑NTRACT❑R <br />NOTE; DOOR AND WINDOW MANUFACTURER TO PROVIDE RATING <br />CERTIFICATI❑N FOR THEIR PRODUCTS INDICATING <br />DOORS WILL WITHSTAND THE PRESSURES <br />RESULTING FROM INDICATED WIND SPEED (3 SEC GUST) <br />(NOTE, DOOR AND WINDOW MANUFACTURER TO PROVIDE <br />(INSTALLATION INSTRUCTIDNS FOR THEIR PRODUCT <br />SUCH THAT WHEN INSTALLED PER THEIR <br />INSTRUCTIONS THE RATED PERFORMANCE WILL <br />BE ATTAINED. <br />1 <br />2 <br />2 <br />3/12 <br />12 — <br />SH 24 <br />00 <br />I <br />z <br />LEIFT J�Llv_VATIOAV <br />RUGHT IE'L_ V"-'-,-'VA TIO 1\1 Q F, <br />I L - E A V A T 10 N <br />N ' <br />s:s <br /><1 <br />D.W.SMITH,M.S.,P.E.#53608 <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLAST❑N DRIVE-DADE CITY, FLORIDA 33525 <br />PHONE: ( CELL) 813-469-2289 E-MAIL: dwsftpe@eo.rth(ink.net <br />SCOPE OF WORK 12'X42' SHED: <br />SH 24 <br />7, <br />ALL WORK SHALL. COMPLY WITH PREVAILING <br />CODES FLORIDA BUILDING CODE, <br />NATIONAL. ELECTRIC CODE, <br />AND THE CITY OF ZEPHYRHILLS <br />ORDINANCES <br />REVIEW DATE I MAR 2 2 Z023 <br />ITY OF ZEPHYRHI <br />PLAN EXAMINER <br />PARCEL: 24- 26- 21- 0040- 00000-1320 <br />PAUL A SHOLAR <br />3512 MALACHITE DR <br />ZEPHYRHILLS, FLORIDA <br />ELEVATIONS SHEET OF <br />FLOOR PLAN 1 of 4 <br />NOTE: CONTRACTOR TO INSTALL DOORS AND WINDOWS ACCORDING <br />IT❑ MANUFACTURER'S INSTRUCTI❑NS, <br />I hereby certif y that I have reviewed this plan and f ound it to be in <br />compliance with ASCE 7-16 and the Florida Building Code 2020 7th Edition <br />David W, Smith, P.E. #53608 <br />RICK GOLLHARDT — DRAFTSMAN <br />PHONE:(CELU 813-781-3651 E-MAIL: rgollhardt@tamj <br />SCALE <br />DO NOT SCALE <br />DESIGN/DRAWN <br />rr, corl R. GOLLHARDT <br />DATE <br />26 FEB 2023 <br />CHECKED <br />D.W.S.PE <br />2023-0129 <br />
The URL can be used to link to this page
Your browser does not support the video tag.