Laserfiche WebLink
FASTENING SCHEDULE <br />CONNECTION FASTENER <br />NUMBER OR SPACING <br />BAND JOIST TO SILL OR TOP PLATE, TOE NAIL <br />12d <br />12" O.C. <br />JOIST TO BAND JOIST, FACE NAIL <br />16d <br />3 <br />JOIST TO SILL OR GIRDER, TOE NAIL <br />12d COMMON <br />3 <br />BRIDGING TO JOIST, TOE NAIL EACH END <br />12d COMMON <br />2 <br />LEDGER STRIP <br />16d COMMON <br />3 @ EACH JOIST <br />SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL <br />16d COMMON <br />16" O.C. <br />TOP OR SOLE PLATE TO STUD, END NAIL <br />16d COMMON <br />2 <br />STUD TO SOLE PLATE, TOE NAIL <br />8d COMMON <br />4 <br />DOUBLED STUDS, FACE NAIL <br />1Od COMMON <br />24" O.C. <br />DOUBLED TOP PLATES, FACE NAIL <br />1Od COMMON <br />16" O.C. <br />TOP PLATES, LAP & INTERSECTIONS, FACE NAIL <br />2-16d OR 3-10d COMMON <br />CONTINUOUS HEADER, TWO PIECES <br />16d COMMON <br />16" O.C. ALONG EACH EDGE <br />CLG. JOISTS TO PLATE, TOE NAIL <br />12d COMMON <br />3 <br />CONTINUOUS HEADER TO STUD, TOE NAIL <br />12d COMMON <br />3 <br />CLG. JOISTS, LAPS OVER PARTITIONS, FACE NAIL <br />4-1Od COMMON <br />CLG. JOISTS TO PARALLEL RAFTERS, FACE NAIL <br />3-16d OR 4-1Od COMMON <br />RAFTER TO PLATE, TOE NAIL <br />12d COMMON <br />3 <br />1" BRACE TO EACH STUD & PLATE, FACE NAIL <br />W COMMON <br />2 <br />1 X 8 OR LESS SHTG TO EACH BEARING, FACE NAIL <br />8d COMMON <br />2 <br />OVER 1 X 8 SHTG. TO EACH BEARING, FACE NAIL <br />W COMMON <br />3 <br />BUILT-UP CORNER STUDS <br />16d COMMON <br />16" O.C. <br />BUILT-UP GIRDER & BEAMS, OF THREE MEMBERS <br />20d COMMON <br />(3) ROWS, 12" O.C. STAGGERED <br />STUDS TO SOLE PLATE, END NAIL <br />16d COMMON <br />2 EACH END <br />TOP PLATE TO TRUSS OR FLOOR JOIST (PERPENDICULAR) <br />16d COMMON <br />2 EACH STUD <br />TOP PLATE TO TRUSS OR FLOOR JOIST (PARALLEL) <br />16d COMMON <br />2 EACH STUD <br />2" X 6" SUB FASCIA <br />10d COMMON <br />(3) PER TRUSS TAIL <br />WOOD STRUCTURAL PANEL SUBFLOORING <br />15/32", 1/2", 7/16" <br />8d COMMON <br />6" O.C. EDGES & 12" O.C. INTERMEDIATE <br />19/320, 3/4" <br />8d COMMON <br />6" O.C. EDGES & 12"O.C. INTERMEDIATE <br />10,11180 <br />10d COMMON <br />6" O.C. EDGES & 12" O.C. INTERMEDIATE <br />WOOD STRUCTURAL PANEL ROOF & WALL SHTG. <br />8d COMMON WALLS <br />112" OR LESS <br />8d RINSHANK ROOF <br />V O.C. EDGES & 6" O.C. INTERMEDIATE <br />19/32" - 3/4" <br />10d COMMON WALLS <br />10d RINSHANK ROOF <br />V O.C. EDGES & 6" O.C. INTERMEDIATE <br />HARDBOARD LAP SIDING OVER SHEATHING <br />8d CORROSION RESISTANT <br />8" O.C. AT EDGES & 12" O.C. <br />OR PER PRODUCT APPROVALS <br />W/MIN. SHANK DIAMETER OF <br />0.092" AT INTERMEDIATE <br />AND MIN. HD. DIAMETER OF <br />0.225" <br />SHEATHING TO BE 15/32' OSB OR 1/2' PLY CDX W/8d RING SHANK NAILS <br />@ 3' O.C, BOUNDARIES, 6' O.C. EDGES & 8' O,C, FIELD <br />USE STEEL PLYCLIPS, <br />2"x 4" TOP CORD BLOCKING ® 48" O.C. FOR <br />FIRST FOUR ROWS OF TRUSSES ® EDGES OF <br />SHEATHING TYP.. BACK NAIL AND TOE NAIL <br />ALTERNATE ENDS W/ (2) 16d NAILS. <br />(2) 2X4 DIAL BRACING - <br />SPACED ® 48" O.C.. (4) <br />16d NAILS ® EACH END <br />(TYP) <br />2X4 DIAGONAL ATTACHED <br />WITH (4) 8d X 3 1/2' <br />NAILS INTERSECTING - <br />BLOCKING <br />�6=1 <br />7_ <br />2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />10dx3" 0 4" O.C. <br />SOFFIT AND FASCIA <br />DOWNSET TOPCHORD OF GABLE <br />END TRUSS TO RUN 2"x 4" <br />MAX OUTLOOKERS SPACED ® 24" O.C. <br />(1) SIMPSON H5 ® EACH <br />OUTLOOKER <br />"L" BRACE TO EXTEND AT LEAST <br />90% OF WEB LENGTH (SEE TABLE) <br />GABLE TRUSS <br />1/2" CDX PLYWOOD OR 7/16" OSB <br />SHEATHING ATTACHED W/ 8d <br />RINGSHANK NAILS ® 4" O.C. EDGES <br />AND 8" O.C. FIELD <br />SIMPSON HGA10 0 24" O.C. <br />STUD WALL (SEE TYP. SEC.) <br />SIMPSON SP2 DR SP4 <br />EACH STUD <br />5/8" OR 1/2" CEILING DENSE <br />GYPSUM WALL BOARD FASTENED <br />WITH 8d COOLER NAILS OR 1 1 /4" <br />LONG DRYWALL SCREWS COMPLYING <br />WITH ASTM C1002 FOR FIRST 8'-0" <br />FRAME FROM END WALL @ 4" O.C. TYP. <br />CONNECTOR <br />SCHEDULE <br />MANUFACTUREUPLIFT CAP. <br />FASTENERS <br />FLORIDA APPROVAL <br />TYPE <br />MODEL# <br />A <br />H2.5A <br />SIMPSON <br />545# <br />10 - 8d <br />10456.2 <br />B <br />H5 <br />SIMPSON <br />455# <br />8 -8d <br />10456.2 <br />C <br />H10S <br />SIMPSON <br />1010# <br />16 - 8dX1 1/2" <br />10446.5 <br />D <br />H14 <br />SIMPSON <br />1350# <br />12 - 8dX 1 1/2" <br />10446.5 <br />13-8d <br />E <br />H10A 2 <br />SIMPSON <br />1080# <br />9 - 8dX 1 1/2" <br />10446.5 <br />F <br />LTS <br />SIMPSON <br />745# <br />12-10d <br />10456.7 <br />G <br />MTS <br />SIMPSON <br />1000# <br />14 -10d <br />13872.14 <br />H <br />SP1 <br />SIMPSON <br />585# <br />10-10d <br />10456.10 <br />1 <br />SP2 <br />SIMPSON <br />1065# <br />12 -10d <br />10456.10 <br />J <br />DSP <br />SIMPSON <br />780# <br />8 -10d <br />10456.1 <br />K <br />(1)FGTR <br />SIMPSON <br />5000# <br />18 SDS 1/4" X 3" <br />11473.2 <br />21/2" X 5" TITEN <br />L <br />(2)FGTR <br />SIMPSON <br />9400# <br />36 SDS 1/4" X 3" <br />11473.2 <br />41/2" X 5" TITEN <br />M <br />HETA20 <br />SIMPSON <br />1810# <br />9 -1ODX 1 1/2" <br />11473.3 <br />N <br />HETA24 <br />SIMPSON <br />1810# <br />9 -1ODX 1 1/2" <br />11473.3 <br />NOTES: <br />USP CONNECTORS MAY BE SUBSTITUTED IF THEY <br />MEET OR <br />EXCEED THE UPLIFT VALUES SHOWN. <br />CONNECTOR SCHEDULE TABLE IS <br />BASED ON LATEST SIMPSON <br />CATALOG, FOR SP <br />#2 <br />2 <br />'nMTI I AAIn rf]fT\/\/ LL= Mr T)AM T K I r\/T �TAlr nMKIr Mr cl A <br />cu <br />CU <br />RECESS RECESS <br />'I 3068 3068 , <br />3 <br />2 <br />FOUIV\DATIOI\\[ <br />DRILL AND EPDXY #5 REBAR IN EXISTING CONCRETE SLAB <br />SPACED 48" 0,C, MAX <br />2 <br />F-IROATT <br />2 <br />UPLIFT CONNECTION - SIMPS❑N STR❑NG-TIE <br />FRAME APPLICATIONS <br />MARK <br />CONNECTOR <br />UPLIFT <br />CAPACITY <br />LATERAL <br />CAPACITY <br />FASTENERS <br />FLORIDA <br />APPROVAL # <br />A <br />H2.5A <br />600 <br />10-801 <br />10456.2 <br />H3 <br />455 <br />8-8d <br />10473.9 <br />H10A <br />1340 <br />18-10d X 1-1/2' <br />10456.2 <br />H10A-2 <br />1080 <br />18-10d X 1-1/2' <br />10456.2 <br />VTC2 <br />370 <br />7-10d X 1-1/2 <br />10861.9 <br />NOTE: CONNECTOR CAPICITIES ARE FOR SYP, REFER TO MANUFACTURERS <br />FOR ADDITIONAL INFORMATION <br />LEGEND <br />® H2.5A <br />I hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-16 and the Florida Building Code 2020 7th Edition <br />David W. Smith, P.E. #53608 <br />INSTALLATION INSTRUCTIONS: <br />INSTALL DOWEL PER SIMPSON STR❑NG-TIE <br />INSTRUCTI❑NS FOR EP❑XY-TIE SET, <br />1. DRILL 3/4" DIA X 6" DEEP HOLE <br />2. CLEAN THE HOLE -REMOVE DUST FROM HOLE WITH <br />OIL FREE COMPRESSED AIR, CLEAN WITH NYLON BRUSH <br />AND BLOW OUT REMAINING DUST, <br />3. FILL HOLE HALF TO 2/3 FULL WITH SIMPSON-SET EPDXY <br />STARTING FROM BOTTOM OF HOLE TO PREVENT AIR POCKETS <br />WITHDRAW NOZZLE AS HOLE FILLS UP. <br />4, INSERT DOWEL, TURNING SLOWLY UNTIL DOWEL REACHES BOTTOM OF HOLE <br />5. ALLOW TO CURE 20 HRS FOR MAS, STRENGTH. <br />EPDXY -TIE SET EPDXY IS A TWO -COMPONENT, LOW ODOR, 1:1 RATIO, 100% <br />S❑LIDS EPDXY -BASED ADHESIVE FOR USE AS A HIGH STRENGTH, NON -SHRINK <br />ANCHOR GROUTING MATERIAL. RESIN AND HARDENER ARE DISPENSED AND MIXED <br />SIMULTANEOUSLY THROUGH THE MIXING NOZZLE, SET MEETS THE ASTM C-881 <br />SPECIFICATION FOR TYPE I, 11, IV AND V, GRADE 3, CLASS B AND C <br />APPLICATIONS SURFACES TO RECEIVE EPDXY MUST BE CLEAN. FOR INSTALLATIONS <br />IN OR THROUGH STANDING WATER, SEE ADHESIVE ANCHORS APPLICATION GUIDELINES <br />FOR DETAILS. THE BASE MATERIAL TEMPERTURE MUST BE 40' F OR ABOVE AT THE <br />TIME OF INSTALLATION. FOR BEST RESULTS, MATERIAL SHOULD BE 70' - 80' F AT THE <br />TIME OF APPLICATION, CARTRIDGES SHOULD NOT BE IMMERSED IN WATER TO FACILITATE <br />WARMING. TO WARM COLD MATERIAL, THE CARTRIDGES SHOULD BE STORED IN A WARM, <br />UNIFORMLY HEATED AREA, OR STORAGE CONTAINER FOR A SUFFICIENT TIME TO ALLOW <br />EPDXY TO WARM COMPLETELY, MIXED MATERIAL IN NOZZLE CAN BE HARDEN IN 5-7 MINUTES <br />AT A TEMPERATURE OF 40' F OR ABOVE. <br />#5 OR #6 REBAR MIN EMBEDMENT 6' <br />DOWELS @ ALL WINDOW & DOOR LOCATIONS <br />ALL OTHERS @ MIN 25' <br />BOND DOWEL TO CONCRETE W/ <br />SIMPS❑N SET EPDXY <br />PER SIMPS❑N INSTRUCTIONS <br />RATED 6200# TENSION <br />3/4' DIA HOLE x 6' DEEP FOR <br />INSTALLATION OF DOWEL <br />CLEAN HOLE AFTER DRILLING <br />BLOW OUT DUST W/ OIL FREE <br />PL A 1\1 <br />COMPRESSED AIR <br />lt <br />RAISE EXISTING CONCRETE SLAB 4' <br />4' EXISTING CONCRETE SLAB <br />��il�ulrr <br />F• ��,� <br />0. <br />ENG <br />0111111110 <br />DOWEL INSTALLATION DETAIL <br />1. ROOF WOOD TRUSS SYSTEMS SHALL BE DESIGNED BY THE MANUFACTURER TO <br />SUPPORT THE FOLLOWING LOADS: <br />A. ROOF TRUSS GRAVITY LOADING CASE <br />TOP CHORD LOADING: <br />LIVE LOAD: 20 PSF (ON THE HORIZONTAL PROJECTION) <br />DEAD LOAD: 25 PSF (ON THE SURFACE AREA) FOR ASPHALT SHINGLES <br />35 PSI (ON SURFACE AREA) FOR CEMENT OR CLAY TILE <br />BOTTOM CHORD LOADING: <br />ATTIC LIVE LOAD: 10 PSF <br />ATTIC LIVE LOAD WITH STORAGE: 30 PSF <br />DEAD LOAD (FOR 1/2" CD GYPSUM):5 PSF FOR 1/2" CD GYPSUM <br />B. ROOF TRUSS WIND LOADING CASE <br />TRUSSES ARE TO BE DESIGNED FOR WIND LOADING AS SHOWN ON DESIGN <br />ANALYSIS, UPLIFT SHALL DEDUCT 2/3 OF DEAD LOADS. <br />2. WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE <br />WITH THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE "NDS" NATIONAL <br />DESIGN SPECIFICATION FOR WOOD CONSTRUCTION ANSI/AF&PA AND THE NATIONAL <br />DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION <br />"ANSI/TPI". <br />3. WOOD MATERIALS SHALL BE SOUTHERN PINE, DOUGLAS FIR OR LARCH AND SHALL <br />BE KILN DRIED AND USED AT 19% MAXIMUM MOISTURE CONTENT. PROVIDE GRADE <br />NO.2 OR BETTER REQUIRED TO SATISFY STRESS REQUIREMENTS. <br />4. CONNECTOR PLATES SHALL BE NOT LESS THAN 0.036 INCHES (20 GAUGE) IN <br />COATED THICKNESS, SHALL MEET OR EXCEED ASTM A653 GRADE 33 OR HIGHER AND <br />SHALL BE HOT DIPPED GALVANIZED ACCORDING TO ASTM A-525 (COATING G60). <br />5. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY AND PERMANENT BRACING <br />AS REQUIRED FOR SAFE ERECTION AND PERFORMANCE OF THE TRUSS. THE <br />GUIDELINES SET FORTH BY THE TRUSS PLATE INSTITUTION PUBLICATION "HIB-91, <br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLING AND BRACING <br />METAL PLATE CONNECTED WOOD TRUSSES" SHALL BE A MINIMUM REQUIREMENT. <br />6. TRUSS MEMBERS AND COMPONENTS SHALL NOT BE CUT, NOTCHED, DRILLED NOR <br />OTHERWISE ALTERED IN ANY WAY WITHOUT THE WRITTEN APPROVAL OF THE TRUSS <br />MANUFACTURER'S ENGINEER. <br />7. SUBMIT COMPLETE SHOP DRAWING FOR ALL WOOD TRUSSES SHOWING MEMBER <br />SIZES, SPAN, DIMENSIONS, CHORD PITCH, LOADING AND REACTIONS. SHOP <br />DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER AND SHALL BEAR THE SEAL OF A <br />PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. <br />8. IF THE NET UPLIFT FORCES SHOWN ON THE FINAL ENGINEERED TRUSS <br />CALCULATIONS ARE GREATER THAN THE CAPACITY OF THE SPECIFIED CONNECTORS, <br />THE CONTRACTOR SHALL SUPPLY CONNECTORS TO MEET THOSE UPLIFT FORCES AS <br />A MINIMUM. <br />D.W.SMITH,M.S.IP.E.#53608 PAUL A SHOLAR <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 3512 MALACHITE DR <br />PROJECTS ENGINEERING CONSULTANT ZEPHYRHILLS, FLORIDA <br />NLAON891 DRIVE -DAD FLORIDA a3525 <br />PHOE (CL)83-46922E-MAIL: CITY, <br />l@erhtnk net FOUNDATION SHEET OF <br />TRUSS <br />SCALE <br />DO NOT SCALE <br />DESIGN/DRAWN <br />, rr, core R. GOLLHARDT <br />DATE <br />26 FEB 2023 <br />2 OF 4 <br />JOB NO. <br />RICK GOLLHARDT - DRAFTSMAN <br />PHONE: (CELL) 813-781-3651 E-MAIL: rQollhardt@tars <br />CHECKED <br />D.W.S.PE <br />2023-0129 <br />