My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
37924 Medical Arts Ct
Zephyrhills
>
Building Department
>
Building Plans
>
37924 Medical Arts Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:17:04 PM
Creation date
2/19/2025 12:45:59 PM
Metadata
Fields
Template:
Building Plans
Street #
37924
Location
Medical Arts Ct
Contractor
Ryman Construction
Building Plans - Permit #
3085
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NEW HEAT PUMP CONDENSING UNIT SCHEDULE <br />GENERAL <br />NOMINAL CAPACITY COOLING <br />COMPRESSOR <br />CONDENSER FAN <br />SINGLE PT. POWER <br />MARK <br />TOTAL kBtu/hSENSIBLE <br />kBtu/h <br />POWER V/0 <br />OTY <br />RLA EA. <br />LRA EA. <br />QTY <br />FLA EA. <br />MCA (A) <br />MOCP (A) <br />MFG. <br />MODEL # <br />REFRIGERANT <br />SEER <br />AMBIENT <br />HSPF <br />NOTES <br />HP-5 & HP-6 <br />36 <br />24 <br />208-230/1 <br />1 1 <br />18.5 <br />83.0 <br />1 <br />0.6 <br />23.7 <br />40 <br />1 CARRIER <br />25HCB6-36 <br />R-410A <br />16 <br />95*F <br />8.5 <br />009(�) <br />NOTE: 0 PROVIDE REFRIGERANT LINE SETS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS & SIZING GUIDELINES. <br />(1) PROVIDE WITH TXV, LOW AMBIENT KIT, SIGHT GLASS, FILTER DRIER, & 5-MINUTE ANTI -CYCLE TIMER. <br />DISCONNECT TO BE PROVIDED BY ELECTRICIAN. <br />SECURE UNIT TO EXISTING CONCRETE PADS WITH FL.PROD.APPROVED TIE DOWN CLIPS (SEE DETAIL.) <br />PROVIDE 2-STAGE COMPRESSOR AND HhL GUARD AROUND CONDENSER. <br />NEW AIR HANDLER UNIT SCHEDULE <br />GENERAL <br />FAN <br />COOLING <br />COOLING CAP <br />HP HEATING CAP <br />ELECTRIC HEAT <br />SINGLE POINT POWER <br />MARK <br />SUPPLY <br />CFM <br />OUTSIDE <br />AIR <br />CFM <br />ESP <br />IN. WG. <br />POWER <br />V/0 <br />TONS <br />(NOM.) <br />MOTOR <br />HP <br />ENT AIR <br />TOTAL <br />kBtu/h <br />A <br />SENS. <br />kBtu/h <br />TOTAL <br />kBtu/h <br />kW <br />(@ RATED VOLTS) <br />MCA <br />MOCP <br />A <br />WT <br />LBS <br />FILTER <br />EFFIC. <br />M FG. <br />MODEL <br />NOTES <br />DB WB <br />AHU-5 <br />- - - - - - - - - - - - - <br />1,100 <br />- - - - - - <br />t__105__I__0.8__t208-230 <br />1 /11 <br />- - - - - - - <br />3.0 <br />0.75 <br />76.9 <br />64.2 <br />4.6 <br />22.8 <br />- - <br />- - - I - - - - - - - - <br />3.8/5.0 <br />- - - - - <br />26.0/28AZj-\ <br />30 <br />- - - - - - - - --- <br />172 <br />- - - <br />MERV-7] <br />- - - - - - <br />CARRIER] <br />- - - - - - - <br />FV4CNBOO5 <br />- - - - - - - - - <br />I nl 0 0 <br />L_ �:� <br />AHU-6 <br />1,100 <br />110 <br />1 0.8 <br />1 208-230/]l <br />� 3.0 <br />0.75 <br />77.0 <br />64.3 <br />1 33.1 <br />23.4 <br />13.0/17.1 <br />3.8/5.0 <br />26.0/28.4 <br />30 <br />172 <br />MERV-7 <br />CARRIERTFV4CNB005TT <br />0 9 <br />NOTE: <br />PROVIDE <br />WITH 2-STAGE PROGRAMMABLE HEAT <br />PUMP THERMOSTAT <br />WITH EMERGENCY HEAT MODE. <br />PROVIDE <br />SECONDARY DRAIN PAN UNDER UNIT <br />WITH FLOAT SWITCH <br />WIRED TO SHUT DOWN FAN MOTOR. <br />DISCONNECT TO BE BY ELECTRICIAN. <br />PROVIDE <br />WITH FULLY INSULATED (1" MINIMUM) <br />GALVANIZED STEEL <br />CABINET, WITH PREPAINTED FINISH. <br />PROVIDE <br />WITH EMERGENCY ELECTRICAL HEATER <br />AND SINGLE POINT <br />POWER CONNECTION TO UNIT (AHU & HEATER). <br />EXISTING SPLIT SYSTEM UNIT SCHEDULE <br />GENERAL <br />HEATING <br />COOLING <br />SUPPLY <br />OUTSIDE <br />FILTER <br />E A <br />EAT * F <br />T <br />TONS <br />kW EMERG. <br />HEAT PUMP <br />TOTAL <br />SENS. <br />AMBIENT <br />REFRIG <br />MARK <br />CFM <br />AIR <br />EFFIC <br />b <br />(db/wb) <br />d b W <br />(NOM.) <br />HEATING <br />TOTAL MBH <br />MBH <br />MBH <br />M FG. <br />AHU MODEL <br />HP MODEL <br />AGE <br />RATING 'F <br />TYPE <br />NOTES <br />CFM A <br />AHU-1 HP-1 <br />cl 1�90 0 <br />215 <br />MERV 7 <br />.0 <br />77.5/65.0 <br />5/65 <br />77 ��q <br />F766 <br />5 <br />5-KW ESTIMATED <br />62.0 <br />58.5 <br />41.0 <br />CARRIER <br />2019 <br />95 <br />R-41 OA <br />CH1 4NBO60 <br />AHU-2 HP-2 <br />1,810 <br />150 <br />MERV 7 <br />76.6/63.3 <br />6.3 <br />. / 3 <br />5 <br />5-KW ESTIMATED <br />62.0 <br />56.2 <br />42.0 <br />CARRIER <br />2019 <br />95 <br />R-410A <br />CH14NBO60 <br />AHU-3 HP-3 <br />1,860 <br />195 <br />MERV 7 <br />77.2/64.5 <br />5 <br />5-KW ESTIMATED <br />62.0 <br />57.6 <br />40.5 <br />CARRIER <br />2019 <br />95 <br />R-410A <br />@ <br />CH14NBO60 <br />AHU-4 HP-4 <br />1,800 <br />175 <br />MERV 7 <br />770/64.2 <br />) 5 <br />5-KW ESTIMATE& <br />62.0 <br />55.3 <br />39.5 <br />CARRIER <br />2018 <br />95 <br />R-410A <br />(D 0 0 <br />CH14NBO60 <br />NOTES: Ul PROVIDE WITH NEW PROGRAMMABLE 7-DAY THERMOSTAT <br />AHU ACCESS LIMITED - EMERG HEAT AND AHU NAMEPLATE ESTIMATED AND MUST BE FIELD VERIFIED PRIOR TO ANY WORK. <br />SERVICE UNIT COMPLETELY (SEE NOTES). <br />.SERVICE WORK REQUIRED: <br />CONTRACTOR SHALL SERVICE EXISTING (TO REMAIN) AIR HANDLERS AND HEAT PUMP CONDENSING UNITS COMPLETELY AND REPLACE <br />ANY DEFECTIVE PARTS AS NEEDED. PROVIDE SERVICE REPORT TO PROJECT MANAGER. SERVICE WORK SHALL INCLUDE AT A <br />MINIMUM: LUBRICATE ALL BEARINGS, REPLACE ANY BELTS, RE -CHARGE CIRCUITS OR REPAIR REFRIGERANT LEAKS (RE-CLAIM / <br />RE -CHARGE CIRCUITS IF NEEDED), REPLACE FILTERS, CLEAN EVAP COILS, CLEAN DRAIN PAN, AND CLEAN/REPAIR INSULATION ON <br />INSIDE OF UNITS. CONDENSATE PIPING INSULATION SHALL BE UPDATED TO ENSURE FULLY INSULATED PIPING INSIDE BUILDING. <br />NEW AIR DEVICE SCHEDULE <br />GENERAL <br />CONSTRUCTION <br />MARK <br />TYPE <br />FUNCTION <br />FRAME SIZE <br />PATTERN <br />MATERIAL <br />FINISH <br />M FG. <br />MODEL <br />NOTES <br />CD <br />CEILING DIFFUSER <br />SUPPLY <br />24x24 <br />LOUVERED FACE <br />ALUMINUM <br />WHITE <br />PRICE <br />AMD <br />CD2 <br />CEILING DIFFUSER <br />SUPPLY <br />12X12 <br />LOUVERED FACE <br />ALUMINUM <br />WHITE <br />PRICE <br />AMD <br />0) <br />RGC <br />RETURN GRILLE <br />RETURN <br />24X24 <br />BLADES <br />ALUMINUM <br />WHITE <br />PRICE <br />630DAL <br />G) <br />LSG <br />LVRD SOFFITT GRILL <br />EXHAUST <br />3X10 <br />BLADES <br />ALUMINUM <br />WHITE <br />GREENHECK <br />EL-10X3 <br />@ <br />NOTES: (j) PROVIDE WITH OPPOSED BLADE DAMPER. <br />M <br />NEW FAN SCHEDULE <br />GENERAL <br />CONSTRUCTION <br />MARK <br />CFM <br />SONES <br />ESP (IN-WG) <br />ELEC. <br />MOTOR <br />DRIVE <br />TYPE FAN <br />MANUF. <br />INTERLOCK WITH <br />MODEL <br />WEIGHT (Ibs) <br />NOTES <br />EF-1 <br />70 <br />2.0 <br />0.375 <br />120/1 -PH <br />41 WATTS <br />DIRECT <br />CEILING <br />COOK <br />LIGHTS <br />GC- 148 <br />15 <br />EF-2 <br />r5o <br />2.2 <br />0.375 <br />120/1 -PH <br />41 WATTS <br />DIRECT <br />CEILING <br />COOK <br />THERMOSTAT <br />GC-148 <br />15 <br />G) (2) <br />EF-3 <br />50 <br />2.0 <br />0.375 <br />120/1 -PH <br />41 WATTS <br />DIRECT <br />CEILING <br />COOK <br />LIGHTS <br />GC-148 <br />15 <br />0) <br />EF-4 <br />50 <br />2.2 <br />0.375 <br />120/1 -PH <br />41 WATTS <br />DIRECT <br />CEILING <br />COOK <br />WALL SWITCH <br />GC-148 <br />15 <br />00 <br />NOTES: PROVIDE FAN WITH CEILING GRILLE, FAN SPEED CONTROLLER, GALV.METAL HOUSING, GEMINI ISOLATOR KIT AND BACKDRAFT DAMPER. <br />DISCONNECT BY ELECTRICIAN. INTERLOCK AS SCHEDULED TO BE BY ELECTRICIAN. <br />COOLING ONLY THERMOSTAT FURNISHED BY MECHANICAL AND WIRED BY ELECTRICIAN. <br />STEPANEK-L <br />1% ANDASSOCIATES <br />�IF2257 TWELVE OAKS WAY, SUITE 103 <br />WESLEY CHAPEL. FL 33544 <br />PH (813) 991-1248 <br />REGISTRY # 8397 21-1 43 <br />0 <br />c <br />t "o <br />(D CO Lo <br />to 0 <br />CO 0 <br />CO (0 <br />0 N <br />< U_ <br />Z <br />z cl. U_ <br />0 :D E <br />F- <br />N <br />0 <br />(0 <br />0) <br />0 <br />Job Number <br />f_-V�l D <br />N,� <br />No 56189 % <br />k441 <br />% STATE OR <br />0 <br />A\ <br />0 R <br />`elS/0NA <br />1111tills)l, <br />MATTHEW D. LEWIS, P.E. FL LIC#56189 <br />
The URL can be used to link to this page
Your browser does not support the video tag.