Ism* Date <br />c: <br />OD Lf) <br />0 <br />VENTILATION AIR SCHEDULE AHU-1 VENTILATION AIR SCHEDULE AHU-4 <br />Z m_j <br />z CL LL <br />:) E <br />REQUIRED 0 ZONE (D SYSTEM(j) REQUIRED G) REQUIREDC1 PROVIDED REQUIRED (j) ZONE@ SYSTEM@ REQUIRED (a) REQUIREDC PROVIDED (D M (0 <br />SPACE FUNCTION REQUIRED NUMBER AIR DISTRIB. VENT.(Ev) OUTSIDE (Vbz) EXHAUST EXHAUST SPACE FUNCTION REQUIRED (:D NUMBER AIR DISTRIB. VENT.(Ev) OUTSIDE (Vbz) EXHAUST EXHAUST co <br />AREA OUTSIDE AIR AREA OUTSIDE AIR OR EXHAUST _j <br />PEOPLE (Pz) EFFECTIVE. EFFICIENCY AIR (CFM) PEOPLE (Pz) EFFECTIVE. EFFICIENCY AIR (CFM) <br />(SQFT) AIR (CFM) AIR (CFM) (SQFT) AIR (CFM) AIR (CFM) <br />co <br />OFFICES/EXAMS 602 5 CFM CFM -PERSONS) OFFICES/EXAMS 903 5 CFM + 0.06 CFM 4.5 ( 5-PERSONS) 1.0 1.0 77 (D <br />+ 0.06 3 ( 5 1.0 1.0 51 PERSON SQFT 1,000-SQF-T -0 <br />PERSON SQFT 1,000-SQFT 0 <br />CFM RESTROOMS 0 70 CFM 2-T ILETS 140 140 V� ry <br />WAITING LOBBY 345 7.5 CFM + 0.06 10.4 (30-PERSON 1.0 0.9 98 TOILET <br />PERSON SQFT 1,000-SQFT ci��� - - - - , <br />CFM �3 5 1.0 1.0 32 HALLWAYS 310 0.06 CFM 1.0 1.0 340 <br />RECEPTION AREA 152 5 CFM + 0.06 4.6 O-PERSON! SQFT <br />PERSON " 1,OOO-SQFT BREAKROOM 85 7.5 CFM + 0.18 CFM 6 (70-PERSONS) 1.0 0.8 60 -- <br />RESTROOMS 0 70 CFM 2-TOILETS 140 140 PERSON SQFT l'OOO-S0FT <br />TOILET <br />SYSTEM POPULATION, Ps: TOTAL ZONE POPULATION, I Pz 10.5 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou / MIN Ev) (CFM) 174 <br />HALLWAYS 268 0.06 CFM 1.0 1.0 16 <br />SQFT <br />I I I I OUTSIDE AIR INTAKE UNCORRECTED, (Vou) (=DxY-RpPz+Y-RaAz) 139 PROVIDED OUTSIDE AIR INTAKE (CFM) 175 <br />SYSTEM POPULATION, PS: 17 TOTAL ZONE POPULATION, I Pz 17.9 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou / MAX Ev) (CFM) 213 z �l <br />I - OCCUPANT DIVERSITY, D (=Ps/ I Pz) 0.76 TOTAL PRESSURE PROVIDED INT.- PROVIDED EXH. (CFM) <br />OUTSIDE AIR INTAKE UNCORRECTED,(Vou) (=DxY-RpPz+ 92 PROVIDED OUTSIDE AIR INTAKE (CFM) 215 T I <br />1 NOTE : CD REQUIREMENTS IN ACCORDANCE WITH TABLE 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE MECHANICAL. <br />OCCUPANT DIVERSITY, D (=Ps/Y-Pz) 0.95 _FTOTAL PRESSURE PROVIDED INT.- PROVIDED EXH. (CF7M)75 <br />NOTE REQUIREMENTS IN ACCORDANCE WITH TABLE 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE MECHANICAL. <br />VENTILATION AIR SCHEDULE AHU-5 <br />FUNCTION REQUIRED (j) REQUIRED G) ZONE 0 SYSTEM 0 REQUIRED 0 REQUIREDC1 PROVIDED <br />SPACE AREA OUTSIDE AIR OR EXHAUST NUMBER AIR DISTRIB. VENT.(Ev) OUTSIDE (Vbz) EXHAUST EXHAUST <br />VENTILATION AIR SCHEDULE AHU-2 (SOFT) PEOPLE (Pz) EFFECTIVE. EFFICIENCY AIR (CFM) AIR (CFM) AIR (CFM) <br />OFFICES/EXAMS 361 5 CFM + 0.06 CFM 1.8 ( 5-PERSONS) 1.0 1.0 31 <br />FUNCTION REQUIRED REQUIRED @ ZONE T SYSTEM 0 REQUIRED 0 REQUIREDC PROVIDED PERSON SQFT 1,000-SQFT <br />SPACE AREA OUTSIDE AIR OR EXHAUST NUMBER AIR DISTRIB. VENT.(Ev) OUTSIDE (Vbz) EXHAUST EXHAUST RESTROOMS 0 70 CFM 1 -TOILETS 70 70 <br />(SQFT) PEOPLE (Pz) EFFECTIVE. EFFICIENCY AIR (CFM) AIR (CFM) AIR (CFM) TOILET <br />OFFICES/EXAMS 639 5 -��-FM + 0.06 CFM 3.2 ( 5-PERSONS) 1.0 1.0 54 <br />PERSON SQFT HALLWAYS 152 0.06 CFM 1.0 1.0 9 <br />1,000-SQFF SQFT <br />0 CFM CFM <br />RESTROOMS 0 7 1 -TOILETS 70 70 BREAKROOM 100 7.5 CFM + 0.18 7 (70-PERSONS) 1.0 0.9 71 <br />TOILET I PERSON SQFT 1,000-SQFT <br />HALLWAYS 247 0.06 CFM 1.0 1.0 15 <br />SQFT SYSTEM POPULATION, Ps: TOTAL ZONE POPULATION, I Pz 8.8 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou MIN Ev) (CFM) 103 <br />STORAGE 95 0.06 CFM 1.0 1.0 6 <br />SOFT OUTSIDE AIR INTAKE U N CORRECTED, (Vou) (=DxY-RpPz+ 93 PROVIDED OUTSIDE AIR INTAKE (CFM) 105 <br />SYSTEM POPULATION, Ps: 3 TOTAL ZONE POPULATION, Y, Pz 3.2 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou MIN Ev) (CFM) 75 OCCUPANT DIVERSITY, D (=Ps/Y-Pz) 0.68 TOTAL PRESSURE PROVIDED INT.- PROVIDED EXH. (CFM) 35 <br />7� <br />OUTSIDE AIR INTAKE U N CORRECTED, (Vou) (=DxY-RpPz+Y-RaAz) 75 PROVIDED OUTSIDE AIR INTAKE (CFM) 150 NOTE (j) REQUIREMENTS IN ACCORDANCE WITH TABLE 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE MECHANICAL. <br />OCCUPANT DIVERSITY, 1.0 TOTAL PRESSURE = PROVIDED INT.- PROVIDED EXH. (CFM) 8 <br />D (=Ps/ I Pz) -0 <br />NOTE REQUIREMENTS IN ACCORDANCE WITH TABLE 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE MECHANICAL. <br />VENTILATION AIR SCHEDULE AHU-6 <br />REQUIRED ZONE SYSTEM REQUIRED (j) REQUIREDC1 PROVIDED <br />FUNCTION REQUIRED (j) <br />SPACE AREA OUTSIDE AIR NUMBER AIR DISTRIB. VENT.(Ev) OUTSIDE (Vbz) EXHAUST EXHAUST <br />(SQFT) PEOPLE (Pz) EFFECTIVE. EFFICIENCY AIR (CFM) AIR (CFM) AIR (CFM) <br />VENTILATION AIR SCHEDULE AHU-3 <br />ENTRY LOBBY 110 5 CFM + 0.06 CFM 1.1 (10-PERSONS) 1.0 1.0 12 <br />PERSON SQFT 1,000-SQFT <br />FUNCTION REQUIRED REQUIRED ZONE 0 SYSTEM@ REQUIRED 0 REQUIREDC1 PROVIDED <br />SPACE AREA OUTSIDE AIR NUMBER AIR DISTRIB. VENT.(Ev) OUTSIDE (Vbz) EXHAUST EXHAUST OFFICES 460 5 CFM + 0.06 CFM 2.3 5-PERSONS 1.0 1.0 39 <br />PEOPLE (Pz) EFFECTIVE. EFFICIENCY AIR PERS SQFT 1,0 <br />(SQFT) AIR (CFM) AIR (CFM) <br />(CFM) ON 00-SQFF <br />CFM -PERSONS) WAITING LOBBY 144 7.5 CFM + 0.06 CFM 4.3 (30-PERSONS) 1.0 1.0 41 <br />OFFICES/EXAMS 660 5 CFM + 0.06 3.3 5 1.0 1.0 56 PERSON SQFT 1,000-SQFF <br />PERSON SQFT 1,000-SQFT <br />RESTROOMS 0 70 CFM 1 -TOILETS 70 70 <br />WAITING LOBBY 300 7.5 CFM + 0.06 CFM 9 030-PERSONS) 1.0 0.9 86 TOILET <br />PERSON SQFT 1,000-SQFT <br />HALLWAYS 102 0.06 CFM 1.0 1.0 6 <br />RECEPTION AREA 120 5 CFM + 0.06 CEM 3.6 �30-PERSON'�) 1.0 1.0 25 SQFT <br />PERSON " l'0OO-SQFT <br />RESTROOMS 0 70 CFM 1 -TOILETS 70 70 SYSTEM POPULATION, Ps: 7 TOTAL ZONE POPULATION, I Pz 7.7 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou MAX Ev) (CFM) 104 <br />1 TOILET I I I I I I Job NWTibw <br />HALLWAYS 240 0.06 CFM OUTSIDE AIR INTAKE UNCORRECTED, (Vou) (=DxY-RpPz+Y-RaAz) 94 PROVIDED OUTSIDE AIR INTAKE (CFM) 110 <br />14 <br />SQFT 1.0 1.0 OCCUPANT DIVERSITY, D (=Ps/ I Pz) 0.9 -F AL PRESSURE PROVIDED INT.- PROVIDED EXH. (CFM) 40 <br />TOT Revk*xw <br />SYSTEM POPULATION, Ps: 15 TOTAL ZONE POPULATION, I Pz 15.6 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou / MAX Ev) (CFM) 195 NOTE REQUIREMENTS IN ACCORDANCE WITH TABLE 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE MECHANICAL. <br />OUTSIDE AIR INTAKE UNCORRECTED,(Vou) (=DxY-RpPz+Y-RaAz) 1 175 PROVIDED OUTSIDE AIR INTAKE (CFM) 195 <br />OCCUPANT DIVERSITY, D (=Ps/ I Pz) -7 0.95 TOTAL PRESSURE PROVIDED INT.- PROVIDED EXH. (CFM) 125 <br />NOTE REQUIREMENTS IN ACCORDANCE WITH TABLE 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE MECHANICAL. NOTE ON OVERALL BUILDING PRESSURE WITH ADDED FANS: <br />�NS* <br />THERE ARE ADDITIONAL EXHAUST FANS SHOWN BUT NOT <br />REQUIRED BY CODE, AND ONLY FOR ODOR/HEAT CONTRJOL. <br />WITH ALL CONDITIONS OF FANS RUNNING, THE BUILDING WILL <br />MAINTAIN PRESSURE AS FOLLOWS: <br />WITH ALL (8) EF-1 RESTROOM FANS ON = +390-CFM <br />WITH ADDED (1) EF-2 FAN ON +340-CFM <br />WITH ADDED (2) EF-3 FANS ON +240-CFM <br />WITH ADDED (4) EF-4 FANS ON +40-CFM �A�_-\N D <br />G E N <br />No 56189 <br />STATE 0 <br />0 <br />0 R <br />STEPANEK-L <br />'0 JF.r <br />frill% <br />ANDASSOCIA , L­� - I <br />k2257 TWELVE OAKS WAY, SUITE 103 Smt No. <br />WESLEY CHAPEL, FL 33544 <br />PH (813) 991-1248 <br />REGISTRY # 8397 21-143 M3 <br />MATTHEW D. LEWIS, P.E. FL LIC#56189 <br />