Laserfiche WebLink
(5 <br />Z <br />Z <br />L&J <br />�_ L� <br />1F 0 <br />_j <br />z <br />W <br />EQ <br />Z <br />i5 Z <br />35 <br />0 => <br />z m <br />Lj 0: <br />U) 0 <br />0 <br />(L V) <br />0 <br />Q <br />0 -1 <br />LL a- <br />I�L <br />LLI < <br />Z <br />ui Z <br />(f) 0 <br />L_ N <br />od <br />a <br />0 <br />Lj V <br />2 <br />Z <br />zs <br />LLJ m <br />00 <br />LLJ <br />V) <br />Uj <br />z <br />00 <br />z <br />0 <br />LLJ <br />00 <br />09 <br />m <br />CL < <br />W <br />x 0 <br />uj <br />Q <br />W M <br />U) F) <br />L_ Z <br />00 <br />EL <br />U) <br />p Ld <br />z <br />LLJ <br />2 <br />5 <br />LLJ <br />Ld <br />_j <br />_j <br />< <br />LJ V) <br />V) LLJ <br />z 0 <br />Ld <br />x <br />LJ <br />�E <br />0 <br />0 V) <br />_j <br />:j <br />Q 0 <br />60 <br />LLJ 6 <br />m <br />Ld <br />& 00 <br />Ld 0 <br />�3 0 <br />O� Z <br />0 <br />Z <br />LLJ M <br />m _j <br />C5 < <br />08 <br />z _j <br />LAJ <br />m 0 <br />t� <br />0 CD <br />z <br />z <br />CL <br />0 <br />Z <br />Ld L11 <br />0 <br />F_ z <br />uJ _J <br />0 <br />0 <br />Ir <br />uj <br />Ld <br />Ld <br />LJ <br />0 <br />Lj U) <br />> LA_ <br />0 z <br />C) W <br />0 <br />LLJ <br />� z <br />0 Lj <br />LLJ <br />0 LJ <br />z <br />:n IL <br />0 Ll <br />z of <br />LLI 6 <br />Z <br />Lo 0 <br />LL <br />00 <br />0 <br />f2 z <br />1.1 <br />z Ill <br />Lu <br />0 <br />W CL <br />on <br />U) <br />z <br />Ld <br />uj <br />0- < <br />U) <br />cf; z <br />0 < <br />z z <br />1 0 <br />a <br />z <br />a- 0 <br />220V, DEDICATED 20A POWER SUPPLY <br />NOTE: PROVIDE BUCK/BOOST <br />TRANSFORMER AS NEEDED TO <br />MAINTAIN A MINIMUM OF <br />208V TO UNIT. NOMINAL 2"x,3" ELECTRICAL BOX WITH <br />0 <br />B <br />D <br />F <br />OsT <br />D To <br />AIR COMPRESSOR: <br />MIDMARK P22 <br />04 <br />E <br />DISCONNECT SWITCH COVER PLATE WITH HOLE. 4—#18'S <br />SUPPLIED BY CONTRACTOR. (STRAND WIRE) TO CONTROL PANEL, <br />LEAVE 4' TAIL OF WIRES OUT FROM <br />POWER CORD (SUPPLIED BOX. SUPPLIED BY CONTRACTOR <br />W/UNIT) HARD WIRED TO <br />DISCONNECT SWITCH <br />FULL LOAD AMPS: 7A <br />11E (0 <br />n 27"Hx26"Wx24"D w/o SOUND COVER <br />32"Hx26"Wx25"D with SOUND COVER <br />SHIP WEIGHT: 285 LBS. <br />SUPPLIED BY BENCO DENTAL. <br />INSTALLED BY CONTRACTOR. <br />VACUUM UNIT: <br />MIDMARK P3 <br />FULL LOAD AMPS; 11.4 <br />58"Hx 1 9.5"Wx 1 8.5"D <br />SHIP WEIGHT: <br />BASE = 402 LBS. <br />TANK = 68 LBS. <br />SUPPLIED BY BENCO I <br />INSTALLED BY CONTRAC <br />220V, DEDICATED 30A POWER <br />SUPPLY <br />NOTE: PROVIDE BUCK/BOOST <br />TRANSFORMER AS NEEDED TO <br />MAINTAIN A MINIMUM OF <br />208V TO UNIT. <br />NOMINAL 2"x3" ELECTRICAL BOX WITH <br />COVER PLATE WITH Y2" HOLE. 4—#18' <br />(STRAND WIRE) TO CONTROL PANEL, <br />LEAVE 4' TAIL OF WIRES OUT FROM <br />BOX. SUPPLIED BY CONTRACTOR <br />DISCONNECT SWITCH <br />SUPPLIED BY CONTRACTOR. <br />POWER CORD (SUPPLIED <br />W/UNIT) HARD WIRED <br />TO DISCONNECT SWITCH <br />INSTALL 4—#18 WIRES FROM <br />CONTROL VALVE TRANSFORMER TO <br />CONTROL PANEL. NOTE: IF DISTANCE <br />EXCEEDS 100' USE 16 GA WIRE <br />INSTALL TWO #18 WIRES FROM <br />CONTROL VALVE TRANSFORMER TO <br />WATER CONTROL VALVE. <br />WATER CONTROL VALVE <br />TRANSFORMER SUPPLIED BY BENCO <br />DENTAL. MOUNT WITHIN 18" OF <br />WATER CONTROL VALVE MOUNTED <br />BY PLUMBER. <br />115v 20a GFCI OUTLET <br />NOTE: UNIT MAY VARY FROM DESIGN <br />SHOWN, SEE MANUFACTURER'S <br />INSTALLATION GUIDE. <br />u <br />06 UU0 <br />fo .' 600SPOL <br />AN <br />4—#18 LOW VOLTAGE WIRES <br />(TO EAC H U N IT) <br />CONTROL PANEL <br />MIDMARK <br />SUPPLIED BY BENCO DENTAL <br />CONTRACTOR TO SUPPLY <br />APPROPRIATELY SIZED ROUGH —IN <br />BOX FOR CONTROL PANEL. <br />SEE BENCO REPRESENTATIVE FOR <br />EXACT ROUGH —IN BOX SIZING. <br />DETAIL - AIR COMPRESSOR 01 DETAIL -VACUUM PUMP 02 DETAIL- WATER CONTROL VALVE 03 DETAIL - CONTROL PANEL 04 <br />REF.: SOURCE: N.T.S. RER: SOURCE: N.T.S. REF.: SOURCE: N.T.S. REF.: SOURCE: N.T.S. <br />MOUNT EXPOSURE — <br />SWITCH TO 2x4 BOX <br />(SUPPLIED BY <br />CONTRACTOR) <br />OR DIRECTLY TO WALL <br />INSTALL 1"0 CONDUIT — <br />THROUGH CEILING WITH <br />MANUFACTURER'S CABLE <br />SUPPLIED BY BENCO. <br />INSTALL 220V, 20A <br />SEPARATE CIRCUIT <br />UNIT TO BE HARD WIRED <br />INSTALL 4x4 ROUGH —IN - <br />BOX WITH SINGLE MUD <br />RING, BLANK FACE PLATE <br />WITH 3/4" GROMMET <br />NOMINAL 2"x3" ELEC. <br />BOX WITH COVER PLATE <br />FOR DATA CABLES. <br />SUPPLIED BY CONTRACTC <br />SUPPLY CONDUIT AS RE( <br />PANORAMIC X—RAY: <br />INSTRUMENTARIUM OP-2D <br />88.15"Hx37.8"Wx48.8"D <br />FULL LOAD AMPS: 10A <br />INE <br />115v 20a FLEX WIRE WITH 6" <br />PIGTAIL AND QUAD RECEPTACLE. <br />(GFCl RECEPTACLES REQUIRED <br />WITHIN 6' OF A WATER SOURCE) <br />NOTE: SEE MANUFACTURER'S <br />TEMPLATE FOR EXACT <br />ROUGH —IN LOCATION. <br />TREATMENT ROOM 1� <br />CONSOLE <br />11 5v 20a FLEX WIRE WITH 6" <br />PIGTAIL AND QUAD RECEPTACLE. <br />(GFCI RECEPTACLES REQUIRED NOTE: SEE MANUFAC <br />WITHIN 6' OF A WATER SOURCE) TEMPLATE FOR EXAC <br />LOCATIONS, <br />NOTE: 2" CONDUIT FOR CC <br />SEE MANUFACTURER'S TEMPLATE DATA CABLES. <br />FOR EXACT ROUGH —IN LOCATION. UTILITY CENTER BEL( <br />\CHAIR <br />f � FLOOR <br />QC'Al r)0C'KIIKIf'Q A <br />_.� 1 11 L-W L.� <br />DETAIL - PANORAMIC X-RAY WIRING <br />05 <br />DETAIL - DENTAL CHAIR RECEPTACLE <br />06 <br />DETAIL - REAR CABINET RECEPTACLE <br />07 <br />DETAIL - TYP. TREATMENT ROOM CONDUITS <br />08 <br />REF.: SOURCE: <br />N.T.S. <br />RER: SOURCE: <br />N.T.S. <br />REF.: SOURCE: <br />N.T.S. <br />REF.: SOURCE: <br />N.T.S. <br />DETAIL <br />09 <br />DETAIL <br />10 <br />DETAIL <br />11 <br />DETAIL <br />12 <br />REF.: SOURCE: <br />N.T.S. <br />REF.: SOURCE: <br />N.T.S. <br />REF.: SOURCE: <br />N.T.S. <br />REF.: SOURCE: <br />N.T.S. <br />DETAIL <br />13 <br />DETAIL <br />14 <br />DETAIL <br />15 <br />DETAIL <br />16 <br />REF.: SOURCE: <br />N.T.S. <br />REF.: SOURCE: <br />N.T.S. <br />REF.: SOURCE: <br />N.T.S. <br />REF.: SOURCE: <br />N.T.S. <br />IMMASAWAfte PRACTICE <br />U I SOLUTIONS <br />PITTSTON, PA - DALLAS, TX - COSTA MESA, CA <br />1 . 8 0 0 . 4 6 2 . 3 6 2 6 / B E N C 0 . C 0 M <br />0 HermanMiller <br />4-1 <br />C <br />=3 <br />E <br />E <br />7j� <br />N <br />m <br />0 <br />Jc <br />I j <br />m <br />.j <br />U. <br />4_0 <br />cu <br />0 <br />ISSUED: DATE: <br />ZONESTUDY MM/DD/YY <br />DESIGN SCHEMATIC <br />07/07/21 <br />DCD (FOR REVIEW) <br />07/23/21 <br />DCD <br />!MM/DDNY <br />C121070-RL <br />DRAWN BY 71 REVI�BY.- CHECKED BY: <br />OTHERS,RL I TH <br />DRAWING TITLE: <br />DENTAL ELECTRICAL DETAILS <br />SHEET: <br />Q3.2 <br />111 7-1 IF <br />