Laserfiche WebLink
I "- 10' <br />1 1 1 1 <br />s_m m m m <br />1 "=2031� 2'1 0 20 40 60 <br />_._ 1 111 It 1 II 1 1 1 1 I i I I .'. 1 I i I <br />45 1 "=30' 30 15 ° 90 1 "=40' so 4� 20 0 40 80 120 <br />I 1 I <br />1 "=50' 75 150 <br />1 0 1 300 <br />1 "=100' <br />48M ELECTRICAL N07M <br />ALL WORK SHALL BE ACCORDING TO THE NEC 2017 <br />2. ALL EQUIPMENT AND SYMBOLS ARE SHOWN <br />DIAGRAMMATICALLY <br />CONTRACTOR IS RESPONSIBLE FOR CONFIRMING EXACT <br />DIMENSIONS PRIOR CONSTRUCTION. <br />3. LIGHT FIXTURES LABELED WITH A CIRCUIT NUMBER <br />SHALL BE CIRCUITED USING 2#12 & 1#12 GROUND IN <br />3/4" CONDUIT UNLESS NOTED OTHERWISE. CONTRACTOR <br />SHALL CONFIRM AND COORDINATE EXACT JUNCTION BOX <br />AND CONDUIT LOCATIONS AND ROUTING IN FIELD. WHIPS <br />TO LIGHTING FIXTURES SHALL BE ALLOWED TO BE MC <br />CABLE. <br />4. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT <br />DIMENSIONED LOCATION OF RECEPTACLES. <br />5. ALL CIRCUITS SHALL BE CIRCUITED USING 2#12 & <br />1#12 GROUND IN 3/4" C FOR ONE OR TWO CIRCUITS <br />NUMBERS INDICATED IE* OR ** O.U.N. 120/208V <br />CIRCUITS RUN OVER 100 FT. SHALL USE 2#10 & 1#10 <br />GROUND 3/4"C. <br />6. CONTRACTOR CAN CONSOLIDATE CONDUIT RUNS <br />ACCORDING TO NEC 2017 CHAPTER 9. <br />7. ALL INFORMATION LEFT BLANK ON A PANEL <br />SCHEDULE IS INDICATED ON THE FLOOR PLANS OR <br />ONE -LINE RISERS. ANY CIRCUIT POSITION ON THE <br />PANEL SCHEDULE LEFT BLANK SHOULD BE CONSIDERED <br />A SPARE. ALL PANELS SHALL BE 22KAlC U.O.N. <br />8. PURSUANT THE REQUIREMENTS OF F.A.C. 61G15-33, <br />THE AVAILABLE FAULT CURRENT CALCULATIONS AND <br />VOLTAGE DROP CALCULATIONS ARE ATTACHED. <br />ELECTRICAL LEGEND <br />® <br />SPECIAL SERVICES OUTLET <br />110 VOLTS DUPLEX OUTLET <br />&h <br />110 VOLTS QUADRUPLE OUTLET <br />,kGFI <br />GROUND FAULT INTERRUPT <br />d0p <br />WATER PROOF w/GROUND FAULT <br />110 VOLTS SPLIT SWITCHED OUTLET <br />220 VOLTS OUTLET <br />TELEPHONE CABLE OUTLET <br />Tv <br />TV/CABLE OUTLET <br />CBL <br />CABLE OUTLET <br />1 <br />ONE WAY SWITCH <br />I2 <br />TWO WAY SWITCH <br />I3 <br />THREE WAY SWITCH <br />OCC <br />OCCUPANCY SENSOR <br />1DM <br />DIMMER SWITCH <br />BATHFAN <br />® <br />CHIMES <br />ICI <br />DISCONNECT SWITCH <br />0 <br />ELECTRICAL PANEL <br />Q <br />DOOR BELL <br />M® <br />ELECTRIC METER <br />PROJECT NAME <br />MEDICAL BUILDING <br />MODIFICATIONS <br />OWNER: <br />ADAA REAL ESTATE LLC <br />2653 BRUCE B DOWNS BLVD. <br />WESLEY CHAPEL , FL 33544 <br />PROJECT ADDRESS <br />38058 ARBOR RIDGE DRIVE. <br />ZEPHYRHILLS, FL 33540 <br />DRAWING BY: <br />DANIEL JALIL <br />Associate AIA <br />M.A. In Architecture & Planning <br />10233 CELTIC ASH DR. <br />Ruskin, FL 33753 <br />Phone (813) 240-3537 <br />THIS DRAWING MEASURING 24"x36" IS THE PROPERTY OF DANIEL <br />JALIL AND MAY NOT BE USED OR REPRODUCED WITHOUT HIS <br />WRITTEN PERMISSION.. <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE <br />DATE IS SIGNED AND SEALED. <br />ENGINEER: <br />I HEREBY CERTIFY THAT I HAVE <br />REVIEWED THE ATTACHED DESIGN AND <br />FOUND IT TO BE IN COMPLIANCE WITH <br />THE 7TH EDITION OF THE FLORIDA <br />BUILDING \\CgDe'Aq?61/ <br />00��,: <br />* . No. 77065 ' <br />DAN EL JAMES COOREY P.E. <br />FL 77065 <br />Phone (813) 507-9166 <br />DATE ISSUED FOR: <br />SHEET TITLE <br />POWER PLAN <br />JOB No. ZPH-0821 <br />SCALE AS NOTED <br />DATE AUG-09-21 <br />DRAW BY DJ <br />CHECKED BY DJ <br />PLOT DATE 08-09-21 <br />DRAWING No <br />El -1 <br />3"-1' 0" 1 1/2"-1' 0" 3/4"=1'-0" 1/4"=1'-0" 1/8"=1'-0" 1/16"=1'-0" <br />0 0 1 1 0 2 2 0 2 4 8 6 0 12 m m IN m m mb 20 bu <br />