My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5350 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
5350 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:00:21 AM
Creation date
2/19/2025 12:37:29 PM
Metadata
Fields
Template:
Building Plans
Street #
5350
Location
Gall Blvd
Contractor
W H Bass Const
Building Plans - Permit #
5878B
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 0804 HARDWARE <br />D. Pair 2'-6"x6'-8" Solid Core Doors At Telephone Cabinet - Hollow <br />Metal Frame <br />1. Hinges: 1-1/2" pair 4-1/2"x4-1/2" NRP Hager 1279 (each <br />leaf) <br />2. Lock Set: Active leaf -Best 83T Dead lock with Deadbolt - <br />Furnished by owner installed by G.C. Inactive leaf to <br />have surface mounted bolt top and bottom, OFCI. <br />E. SPECIALTIES <br />1. Corner Guards: Aluminum 3"x3" x length required x 0.080 <br />thickness with mitered corners. <br />a. Provide along top edge of toilet rooms. <br />b. Provide at outside corner of toilet room <br />c. Provide at both jambs and head of exit doors. <br />d. Vertical member shall be one piece in length. <br />2. Chain Guards At Overhead Door:Aluminum 6" wide <br />x 9'-6" x 0.080 thickness <br />a. Provide on chain side of overhead door <br />b. Cut slot at top of guard to allow sprocket wheel to <br />turn freely. Maximum 1" clearance all sides. <br />c. Cut opening at bottom of guard for alarm junction box. <br />3. Vinyl Numbers: Provide vinyl street numbers of the height <br />required by local authority. Numbers are to be located in <br />the glass panel either above or adjacent to the <br />entrance door. Color to be white. <br />4. Signs: Provide a sign over each glass and aluminum door <br />read as follows "THIS DOOR TO REMAIN UNLOCKED DURING <br />DURING NORMAL BUSINESS HOURS". <br />3.00 Installation <br />A. Install all hardware and specialty items in strict accordance <br />with manufacturers printed instructions, utilizing an <br />appropriate concealed fastening system. <br />SECTION 0901 RESILIENT TILE FLOORING <br />1.00 GENERAL: <br />A. Before commencing work check floor for conformance with <br />specification tolerances for levelness (1/8" per 10' plus <br />or minus non cumulative). <br />B. Level floor to this minimum specification prior to <br />installing Tile. <br />C. If leveling is required use Ardex K-15 in strict accordance <br />with manufactures specification requirements <br />D. Lay resilient tile flooring at 65 degrees F. or above. <br />E. All unused tiles to remain in store along with one unopened <br />box of each the color. <br />2.00 MATERIALS: <br />A. Self Leveling Underlayment <br />1. Primer - Ardex P-51 <br />2. Leveler - Ardex K-15 <br />3. No substitutions for above <br />B. Finish Flooring <br />1. Floor tile shall be Armstrong Imperial #51899, Cool White <br />size to be 12"xl2"xl/8". <br />2. Feature tile shall be Armstrong #56806, Red II size to be <br />12"x 12%1/8". <br />3. Base shall be standard top set cove type, 4" high x 0.08" <br />auge vinyl as manufactured by Armstrong or Flex Co., <br />Color Black). <br />4. Adhesive - Armstrong S.515 clear mastic. <br />SECTION 0901 RESILIENT TILE FLOORING (CONT) <br />3.00 INSTALLATION: <br />A. Self Leveling Underlayment <br />1. All ARDEX products shall be installed in strict <br />accordance with manufacutres printed instructions which <br />the contractor shall obtain and have on site prior to <br />commencement of any work. <br />2. Printed information is available from ARDEX Inc. <br />ARDEX INC., 630 Stoops Ferry Road, Corooplis, PA 15108 <br />Phone (412) 264-4240 Fax (412) 264-1622 <br />B. Finish Flooring <br />1. Remove ridges and bumps from substrate. Fill low spots, <br />cracks, joints, holes and defects with filler recommended <br />by the manufacturer. <br />2. Run grain or pattern in only one direction (side to side.) <br />3. Open enough tile cartons and mix tile to ensure shade <br />variations do not occur within any one space. <br />4. Lay tiles symmetrically about center line of areas with <br />tiles against walls not less thon*6" wide (see drawings <br />for tile layout.) (Note: roll floor with 250 lb. roller) <br />5. Provide -vinyl edging where edge of tiles are exposed and <br />where tiles abut other floor finishes, unless designated <br />otherwise on Drawings. <br />6. Immediately remove excessive adhesive from visible <br />surfaces. <br />7. Wait at least four days after installation before washing <br />floor, to prevent adhesive bonding problems. <br />4.00 FINAL CLEANING AND WAXING: <br />A. Clean floor with a neutral cleaner: Do not use any type of <br />stripper on the floor. Use Buckeye Blue Cleaner or equivalent <br />B. Floor must be thoroughly clean and dry prior to applying wax. <br />Use an untreated dust mop to sweep floor prior to laying wax. <br />C. Waxing Floor <br />1. "Buckeye Casleguard Wax" shall be supplied by owner and <br />received by contractor. <br />2. Owner will furnish four (4), five (5) gallon Action Packs <br />of Buckeye Castleguard Wax. <br />3. Must use "Buckeye Casleguard Wax". (supplied by owner) No <br />substitutions will be accepted unless a written change <br />order is provided by Architect prior to application. <br />4. Contractor to apply a minimum of four (4) coats of wax and <br />will apply additonal coats until all four (4) Action Packs <br />are utilized completely. <br />5. Allow each coat of wax to dry a minimum of forty five (45) <br />minutes before applying the next coat. <br />D. Allow wax to dry overnight prior to buffing. <br />E. Buff the store prior to use. Use a high speed buffer, minimum <br />1500 rpm. <br />F. Provide empty Castleguard Action Pack boxes at final punch. <br />G. Contact Buckeye International if more detailed instructions for <br />application are needed. <br />BUCKEYE INTERNATIONAL, INC. <br />Attn: Brandon Furies <br />2700 Wagner Place <br />Maryland Heights, Missouri 63043-3471 <br />1-800-321-2583 Ext. #187 <br />SECTION 0902 GYPSUM WALL BOARD <br />1.00 <br />MATERIALS: <br />A. <br />Gypsum WolI Board: <br />1. Standard: ASTM C 36. 1/2 inch thick, square cut <br />® <br />rn C) <br />ends, tapered edges, unless otherwise <br />noted on Drawing. <br />2. Water Resistant: ASTM C630, 1/2 " thick, square cut ends <br />tapered edges in restrooms only. <br />o <br />B. <br />Tape: Conform to ASTM C475. <br />W GO <br />C. <br />Joint Compound: Ready mixed conforming to ASTM C475. <br />E <br />D. <br />Wood Supports: Type W, bugle head screws <br />IL v' <br />conforming to ASTM C894. <br />® <br />w <br />E. <br />Metal Supports: Type S, bugle head screws <br />W <br />conforming to ASTM C646. <br />> <br />F. <br />Corner Beads: 1-1/4 x 1-1/4" galvanized steel. <br />W <br />G. <br />Metal Edge Trim: Square nose and "L" type, as <br />.cappropriate. W <br />H. <br />Metal Studs: 3 5/8" metal, 25 gage. <br />I. <br />Control Joint: "V" Shaped, 25 gage. <br />O <br />J. <br />Closure Strips: Flexible closure strip for metal deck, <br />M <br />vulcanized, 1" inch , color black, <br />N o <br />closed cell EDPM synthetic rubber as <br />vi <br />manufactured by "Consolidated Systems <br />Z <br />Inc." Telephone 1-800-624-0925 <br />0 <br />2.00 <br />INSTALLATION: <br />� <br />A. <br />Install metal studs vertically at 16" O.C. <br />(� <br />Q <br />B. <br />Apply gypsum panels "horizontally" at maximum practical length. <br />Q <br />U <br />C. <br />C. <br />Fit ends and edges closely. Position end joints over <br />L <br />n <br />supports and stagger adjacent rows. <br />tj <br />U <br />D. <br />Install water resistant wallboard in toilets. Place factory <br />J J <br />W <br />edges down and treat cut edges and holes with sealant. <br />3 LL <br />1L <br />E. <br />Install metal edge trim where gypsum panels abut a different <br />Jj <br />material and where indicated on drawings. <br />Q <br />F. <br />Install accessories with screws, nails or crimping as <br />J <br />_J = <br />< <br />appropriate. Do not use staples. <br />G. <br />Maintain surface flatness of joint compound, with maximum <br />variation of 1/8" in 10 feet. <br />= <br />U <br />H. <br />Sand joints and areas where joint compound has been applied <br />W <br />to provide a smooth finish suitable to receive paint. <br />C-4 CA W <br />F- <br />I. <br />Install metal studs each side of expansion joints in masonry. <br />s N <br />= <br />J. <br />Install control joints in Gypsum Wallboard where expansion <br />U <br />joints occur in masonry walls. <br />IX <br />Q <br />K. <br />Install closure strips in accordance with manufacturers printed <br />instructions. <br />REVISION <br />SECTION 0903 PAINTING <br />1. 11/20/95 <br />W <br />1.00 <br />GENERAL: <br />2. <br />6 <br />A. <br />This specification and attendant schedule contain all approved <br />3. <br />Z <br />products and colors to be used on AutoZone stores. These <br />products and colors should not be changed without written <br />4. <br />authorization from AutoZone. <br />ARMCT: <br />B. <br />For information regarding availability of material: <br />A <br />AKZO/Chromatic Paint Maximum lead time is 2-5 days. <br />Contact: 1-800-233-2303 <br />CHECKED ff: <br />Sherwin Williams Paint Maximum lecd time is 3-5 days. <br />0/I6/95 <br />Contact: Dove Mahowald at 1-800-321-8194 <br />9� <br />Z� <br />Sto Industries, Atlanta, GA. 2 <br />GA. <br />SPECS <br />Contact: Mary Elzey at <br />Contact: 397 <br />Y <br />Rainguard Products <br />AS 9 <br />Contact: Jeanne Alderson at 1-80 .. 2-4 4 <br />